Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systems Engineering, Sensor Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Model year 2010 (Gen 3) Toyota Prius level 1 testing report.

As a part of the US Department of Energy's Advanced Vehicle Testing Activity (AVTA), a model year 2010 Toyota Prius (Generation 3) was procured by eTec (Phoenix, AZ) and sent to ANL's Advanced Powertrain Research Facility for the purposes of 'Level 1' testing in support of the Advanced Vehicle Testing Activity (AVTA). Data was acquired during testing using non-intrusive sensors, vehicle network connection, and facilities equipment (emissions and dynamometer data). Standard drive cycles, performance cycles, steady-state cycles and A/C usage cycles were conducted. Much of this data is openly available for download in ANL's Downloadable Dynamometer Database (D{sup 3}). The major results are shown here in this report. Given the preliminary nature of this assessment, the majority of the testing was done over standard regulatory cycles and seeks to obtain a general overview of how the vehicle performs. These cycles include the US FTP cycle (Urban) and Highway Fuel Economy Test cycle as well as the US06, a more aggressive supplemental regulatory cycle. Data collection for this testing was kept at a fairly high level and includes emissions and fuel measurements from the exhaust emissions bench, high-voltage and accessory current and voltage from a DC power analyzer, and minimal CAN bus data such as engine speed and pedal position. The following sections will seek to explain some of the basic operating characteristics of the MY2010 Prius over standard regulatory cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Adaptive Circuit Learning for Quantum Metrology

Quantum sensing is an important application of emerging quantum technologies. We explore whether a hybrid system of quantum sensors and quantum circuits can surpass the classical limit of sensing. In particular, we use optimization techniques to search for encoder and decoder circuits that scalably improve sensitivity under given application and noise characteristics. Furthermore, our approach uses a variational algorithm that can learn a quantum sensing circuit based on platform-specific control capacity, noise, and signal distribution. The quantum circuit is composed of an encoder which prepares the optimal sensing state and a decoder which gives an output distribution containing information of the signal. We optimize the full circuit to maximize the Signal-to-Noise Ratio (SNR). Furthermore, this learning algorithm can be run on real hardware scalably by using the "parameter-shift" rule which enables gradient evaluation on noisy quantum circuits, avoiding the exponential cost of quantum system simulation. We demonstrate up to 13.12x SNR improvement over existing fixed protocol (GHZ), and 3.19x Classical Fisher Information (CFI) improvement over the classical limit on 15 qubits using IBM quantum computer. More notably, our algorithm overcomes the decreasing performance of existing entanglement-based protocols with increased system sizes.

42 ENGINEERING↗

Flow Rate Measurement Using {sup 99m}Tc Radiotracer Method in a Pipe Installation

Flow rate is a significant parameter for managing processes in chemical processing plants and water processing facility. Accurate measurement of the flow rate allows engineers to monitor the delivery of process material, which in turn impacts a plant's capacity to produce their products. One of the available methods for determining the flow rate of a process material is by introducing a radiotracer to the system that mimics the material's flow pattern. In this study, a low activity Technetium-99m radioisotope was injected into a water piping setup and the 2'' x 2'' NaI (Tl) detectors were calibrated to detect spectrum peaks at specific points of the pipe installation. Using pulse velocity method, water flow rate was determined to be 11.3 litres per minute. For the sampling method, at different pump capacity, the flow rate was 15.0 litres per minute.

07 ISOTOPE AND RADIATION SOURCES↗

Design and Characterization of a MEMS Probe Scanner for On-chip Atomic Force Microscopy

This paper presents the design and characterization of a microelectromechanical systems (MEMS)-based probe scanner proposed to function as an on-chip atomic force microscope (AFM). The device comprises an in-plane stage with electrostatic actuators and electrothermal displacement sensors. The stage is able to precisely position an AFM probe over a sample to perform tapping-mode AFM imaging. For implementation, a standard silicon-on-insulator (SOI) microfabrication process is used. In a previously reported design, the embedded AFM probe featured only one piezoelectric transducer for simultaneous actuation and sensing, making its use in imaging problematic. To address this issue, the new design features separate actuation and sensing AlN piezoelectric transducers. An extra electrode is also incorporated on the probe that enables canceling the electrical feedthrough from the actuation to sensing. To accommodate the extra signal routing paths, mechanical design of the probe scanner is modified. Device characterization reveals an in-plane displacement range of 8 µm×7 µm with a bandwidth of up to 2.7 kHz. The frequencydomain behavior of the AFM probe is also studied and feedthrough cancellation is performed at the resonant frequency of 127.35 kHz.

42 ENGINEERING↗

Design and Analysis of Embedded I&C for a Fully Submerged Magnetically Suspended Impeller Pump

Improving nuclear reactor power system designs and fuel-processing technologies for safer and more efficient operation requires the development of new component designs. In particular, many of the advanced reactor designs such as the molten salt reactors and high-temperature gas-cooled reactors have operating environments beyond the capability of most currently available commercial components. To address this gap, new cross-cutting technologies need to be developed that will enable design, fabrication, and reliable operation of new classes of reactor components. The Advanced Sensor Initiative of the Nuclear Energy Enabling Technologies initiative is investigating advanced sensor and control designs that are capable of operating in these extreme environments. Under this initiative, Oak Ridge National Laboratory (ORNL) has been developing embedded instrumentation and control (I&C) for extreme environments. To develop, test, and validate these new sensing and control techniques, ORNL is building a pump test bed that utilizes submerged magnetic bearings to levitate the shaft. The eventual goal is to apply these techniques to a high-temperature (700°C) canned rotor pump that utilizes active magnetic bearings to eliminate the need for mechanical bearings and seals. The technologies will benefit the Next Generation Power Plant, Advanced Reactor Concepts, and Small Modular Reactor programs. In this paper, we will detail the design and analysis of the embedded I&C test bed with submerged magnetic bearings, focusing on the interplay between the different major systems. Then we will analyze the forces on the shaft and their role in the magnetic bearing design. Next, we will develop the radial and thrust bearing geometries needed to meet the operational requirements of the test bed. In conclusion, we will present some initial system identification results to validate the theoretical models of the test bed dynamics.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LaserSnake2: An Innovative Approach to Nuclear Decommissioning - 17080

Nuclear decommissioning challenges exist the world over and require innovative approaches to ensure safe and cost effective dismantling of high hazard nuclear facilities. LaserSnake technology makes use of the flexibility and dexterity of snake arm robots to deploy high-powered laser cutting, lifting and manipulation tools. This paper describes the development and use of the system to achieve the successful size reduction and removal of a substantial stainless steel vessel within the First Generation Reprocessing Plant (FGRP) at Sellafield in the UK. Due to the environment, nuclear decommissioning is an extremely challenging activity. High ambient radiation levels often preclude entry to the areas involved, and as industry tries to minimise dose uptake, even moderate radiation levels now require remote solutions. 'In-situ' size reduction of process plant, including vessels and pipework, will allow the removal of the nuclear inventory from a building prior to further decontamination and demolition. The term 'in situ' is in this case used to mean work done on plant items within their existing cells as opposed to moving items from their original location to a dedicated size reduction facility. Traditional size reduction cutting methods, such as reciprocating saws or grinders, pose a significant challenge for remote deployment platforms. This includes the loss of haptic feedback and the length of time taken to perform the task, and difficulty dealing with the reaction forces. Although remote engineered solutions for these tools are possible, they are are typically complicated, unreliable and expensive. Robot deployed laser cutting is widely used in non-nuclear industrial sectors, and offers a simpler method for size reduction. LaserSnake2 is a UK collaborative project, co-funded by the Nuclear Decommissioning Authority, Innovate UK and the Department of Energy and Climate Change. The project combined the skills of robotic experts and laser and optic specialists, to develop a remote handling technology suited for deployment within active nuclear environments. As well as meeting strict safety case requirements, the system provides a safe and cost effective method for decommissioning of complex nuclear spaces. An overview of the system development and deployment is presented in this paper. In July 2016, a successful decommissioning campaign was conducted in the FGRP at Sellafield. The LaserSnake2 system was used to size reduce a double-skinned dissolver vessel within a radiologically active nuclear cell. Planning of the size reduction method and processes, as well as results of the campaign itself are described in this paper. The containment procedures and radiological considerations for the system are presented along with the effects of operations on the cell and ventilation systems. LaserSnake, developed as a modular arm system with up to 4.5 m of articulation, carries an integrated tool comprising a high power, decommissioning specific, laser cutting head, high definition cameras and high powered illumination LEDs. It is designed for precise dismantling work within confined and hazardous environments. The tool can be interchanged, allowing the snake-arm robot also to carry grippers, environmental mapping sensors and other tools which may prove advantageous during a decommissioning campaign. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors [Dissertation]

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal’s intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-GHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (μm-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor’s architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perót displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

Engineering(42)↗

Liquid-phase turbulence measurements in air-water two-phase flows using particle image velocimetry

Liquid-phase turbulence plays a vital role in determining various gas-liquid two-phase flow parameters, such as void fraction distribution, bubble morphology, bubble-bubble interactions, and interfacial area concentration. In this study, a two-phase flow database including both the gas- and liquid-phases measurements was developed focusing on three bubbly flow conditions in an air-water two-phase flow loop with a vertical one-inch diameter circular pipe test section. A particle image velocimetry (PIV) system integrating an optical phase separation method, i.e., the planar laser-induced fluorescence (PLIF) technique using fluorescent particles and optical filtration, was applied to measure the liquid-phase turbulence information, including the time-averaged velocity, Reynolds stress, and turbulent kinetic energy for the liquid phase. The PIV measurements were taken at three ports along the test section at 14.5, 51.5, and 88.5 pipe inner diameters downstream of a bubble injector. In addition, a double-sensor conductivity probe was used to measure radial distributions of the local time-averaged void fraction and gas velocity. The measured liquid-phase turbulence was used to benchmark Sato's turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. Lastly, in the two bubbly flows tested that have low void fractions being less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction.

42 ENGINEERING↗

Uncertainty quantification for Multiphase-CFD simulations of bubbly flows: a machine learning-based Bayesian approach supported by high-resolution experiments

In this paper, we developed a machine learning-based Bayesian approach to inversely quantify and reduce the uncertainties of multiphase computational fluid dynamics (MCFD) simulations for bubbly flows. The proposed approach is supported by high-resolution two-phase flow measurements, including those by double-sensor conductivity probes, high-speed imaging, and particle image velocimetry. Local distributions of key physical quantities of interest (QoIs), including the void fraction and phasic velocities, are obtained to support the Bayesian inference. In the process, the epistemic uncertainties of the closure relations are inversely quantified while the aleatory uncertainties from stochastic fluctuations of the system are evaluated based on experimental uncertainty analysis. The combined uncertainties are then propagated through the MCFD solver to obtain uncertainties of the QoIs, based on which probability-boxes are constructed for validation. The proposed approach relies on three machine learning methods: feedforward neural networks and principal component analysis for surrogate modeling, and Gaussian processes for model form uncertainty modeling. The whole process is implemented within the framework of an open-source deep learning library PyTorch with graphics processing unit (GPU) acceleration, thus ensuring the efficiency of the computation. The results demonstrate that with the support of high-resolution data, the uncertainties of MCFD simulations can be significantly reduced. The proposed approach has the potential for other applications that involve numerical models with empirical parameters.

42 ENGINEERING↗

Monitoring the propagation of mechanical discontinuity using data-driven causal discovery and supervised learning

Mechanical wave transmission through a material is influenced by the mechanical discontinuity in the material. The propagation of embedded discontinuities can be monitored by analyzing the wave-transmission measurements recorded by a multipoint sensor system placed on the surface of the material. The proposed workflow monitors the propagation of mechanical discontinuity through three stages, namely initial, intermediate, and final stages, by using supervised learning followed by data-driven causal discovery. To the end, the workflow processes the multipoint waveform measurements resulting from a single impulse source, while considering the effects of wave attenuation, dispersion and multiple wave-propagation modes due to the discontinuity and material boundaries. Among various feature reduction techniques ranging from decomposition methods to manifold approximation methods, the features derived based on statistical parameterizations of the measured waveforms lead to reliable monitoring that is robust to changes in precision, resolution, and signal-to-noise ratio of the multipoint sensor measurements. The numbers of zero-crossing, negative-turning, and positive turning in the waveforms are the strongest causal signatures of the propagation of mechanical discontinuity. Higher order moments of the waveforms, such as variance, skewness and kurtosis, are also strong causal signatures of the propagation. Finally, the newly discovered causal signatures confirm that the statistical correlations and conventional feature rankings are not always statistically significant indicators of causality.

42 ENGINEERING↗

Modeling and Validation of Performance Limitations for the Optimal Design of Interferometric and Intensity-Modulated Fiber Optic Displacement Sensors

Optical fiber sensors offer advantages over traditional electromechanical sensors, making them particularly well-suited for certain measurement applications. Generally speaking, optical fiber sensors respond to a desired measurand through modulation of an optical signal's intensity, phase, or wavelength. Practically, non-contacting fiber optic displacement sensors are limited to intensity-modulated and interferometric (or phase-modulated) methodologies. Intensity-modulated fiber optic displacement sensors relate target displacement to a power measurement. The simplest intensity-modulated sensor architectures are not robust to environmental and hardware fluctuations, since such variability may cause changes in the measured power level that falsely indicate target displacement. Differential intensity-modulated sensors have been implemented, offering robustness to such intensity fluctuations, and the speed of these sensors is limited only by the combined speed of the photodetection hardware and the data acquisition system (kHz-MHz). The primary disadvantages of intensity-modulated sensing are the relatively low accuracy (?m-mm for low-power sensors) and the lack of robustness, which consequently must be designed, often with great difficulty, into the sensor's architecture. White light interferometric displacement sensors, on the other hand, offer increased accuracy and robustness. Unlike their monochromatic-interferometer counterparts, white light interferometric sensors offer absolute, unambiguous displacement measurements over large displacement ranges (cm for low-power, 5 mW, sources), necessitating no initial calibration, and requiring no environmental or feedback control. The primary disadvantage of white light interferometric displacement sensors is that their utility in dynamic testing scenarios is limited, both by hardware bandwidth and by their inherent high-sensitivity to Doppler-effects. The decision of whether to use either an intensity-modulated interferometric sensor depends on an appropriate performance function (e.g., desired displacement range, accuracy, robustness, etc.). In this dissertation, the performance limitations of a bundled differential intensity-modulated displacement sensor are analyzed, where the bundling configuration has been designed to optimize performance. The performance limitations of a white light Fabry-Perot displacement sensor are also analyzed. Both these sensors are non-contacting, but they have access to different regions of the performance-space. Further, both these sensors have different degrees of sensitivity to experimental uncertainty. Made in conjunction with careful analysis, the decision of which sensor to deploy need not be an uninformed one.

42 ENGINEERING↗

On-board Radiation Sensor and Low-Altitude Contour Mapping of Radiation Fields using UAS Swarm - 18239

This paper addresses the design of light weight radiation sensors for the small-scale unmanned aerial system (UAS), and its implementation for low-altitude radiation source localization and contour mapping. The compact, high-resolution gamma-ray CZT sensors were integrated to UAS platforms as plug-and-play components using Robot Operation System (ROS). In this work, the UAS swarm consists of three platforms positioned in circular formation. The onboard data analysis provides time and position stamped intensities of gamma-ray peaks for each UAS-based sensor that are used as the input data for the swarm flight control algorithm. Each UAS measures radiation simultaneously for estimating gradient of radiation to compute a bulk heading angle of the swarm for contour mapping, which can provide relatively precise boundary of the safe area for potential human exploration. The UAS radiation sensors allow measurements from just few meters up to hundreds of meters thus filling the gap between land- and helicopter- based platforms. The swarm of UAS has advantages over a single agent based approach in detecting radiative sources and effectively mapping the area. The proposed method can locate sources of radiation as well as mapping the contaminated area for enhancing situation awareness capabilities for first responders. Computer simulation is presented for UAS swarm based source localization and contour mapping in the simulated radiation fields created by the MCNP code. Selected key gradient estimation and contour mapping algorithms are validated experimentally with small scale multicopter UAS in the indoor flight test bed. (authors)

42 ENGINEERING↗

Measuring Transverse Displacements Using Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV): Development and Field Validation

Measurement of bridge displacements is important for ensuring the safe operation of railway bridges. Traditionally, contact sensors such as Linear Variable Displacement Transducers (LVDT) and accelerometers have been used to measure the displacement of the railway bridges. However, these sensors need significant effort in installation and maintenance. Therefore, railroad management agencies are interested in new means to measure bridge displacements. This research focuses on mounting Laser Doppler Vibrometer (LDV) on an Unmanned Aerial System (UAS) to enable contact-free transverse dynamic displacement of railroad bridges. Researchers conducted three field tests by flying the Unmanned Aerial Systems Laser Doppler Vibrometer (UAS-LDV) 1.5 m away from the ground and measured the displacement of a moving target at various distances. The accuracy of the UAS-LDV measurements was compared to the Linear Variable Differential Transducer (LVDT) measurements. The results of the three field tests showed that the proposed system could measure non-contact, reference-free dynamic displacement with an average peak and root mean square (RMS) error for the three experiments of 10% and 8% compared to LVDT, respectively. Such errors are acceptable for field measurements in railroads, as the interest prior to bridge monitoring implementation of a new approach is to demonstrate similar success for different flights, as reported in the three results. This study also identified barriers for industrial adoption of this technology and proposed operational development practices for both technical and cost-effective implementation.

42 ENGINEERING↗

The Dark Energy Spectrographic Instrument (DESI) Guide-Focus Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with the The Institut de Física d’Altes Energies (IFAE) in Barcelona (Spain) involved both research planning for eventual observing on the DESI telescope; and in providing hardware jointly designed by LBNL and IFAE; ten guide and focus sensor systems (GFAs) that either provide feedback to the Mayall telescope tracking system or provide focus position information to the DESI corrector hexapod. The key major goals of this CRADA were achieved.For survey planning, Drs. Fernandez, Fosalba, Garcia-Bellido, and Gaztañaga were all important contributors to the working groups to which they were assigned. Their application of redshift techniques, development of simulations to support target selection, exploration of the use of alternative observables to extract cosmological information like AP and void statistics, and the use of PAU data to assist in the optimization of targeting selections have been vital in the early planning for targets during commissioning. The major role in the project involved Drs. Castander, Miquel, Padilla, and Sànchez. They were all directly involved with the development of the Guide-Focus Assembly (GFA) hardware, software and filter validation. In order to accomplish the goals of the DESI Project, the Mayall telescope must track DESI targeted galaxies for up to 15 minutes and the DESI corrector must be repositioned on its hexapod system for different telescope orientations. The guide and focus assemblies (GFA) provide in this information. There are ten GFA modules on the focal plane, six providing tracking information and four providing focus information. A common GFA design supports both functions by a simple switching of its operating mode. IFAE designed, fabricated, tested and delivered twelve GFAs. Once received at LBNL, the GFAs were integrated with the focal plane. This was an iterative process as the GFA’s were delivered as they were made. Our working relationship with the IFAE scientists and engineers was remarkable given the distance and time zone issues. The GFAs have performed extremely well during the commissioning phase of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Parametric and Sensitivity Analysis of a Steam Generator Model Using Python and Machine-Learning Tools

For this study, we used Python and machine-learning tools to perform a comprehensive parametric and sensitivity analysis on a steam generator (SG) model. (The Python model was based on a previously completed MATLAB framework for the Holtec SMR-160 SG.) We investigated the influence of various input parameters (e.g., heat transfer coefficient [HTC], Nusselt number, and heat exchanger effectiveness) on the system’s output. With machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN), which was developed at Idaho National Laboratory, we were then able to perform an automated analysis of the SG inputs’ effect on the HTC. The analysis results give valuable insights into the performance and optimization of SG systems. We found the inlet mass flow rate (MFR) to have the greatest impact on the HTC, followed closely by the inlet temperature, and then pressure. Shifting of the input parameters causes the location of the maximum HTC along the SG length to change incrementally. The cold leg (CL) MFR was also found to impact the HTC magnitude as well as the location of the maximum HTC. At between 0.4–0.9 of the total SG length, the input parameters experience maximum impact on the HTC, leading us to suggest that sensors be efficiently placed on the SG so as to closely and effectively monitor thermal-hydraulic properties during reactor operation. We also found that the sensitivity data calculated manually agrees with the RAVEN – based data, confirming the same range of maximum sensitivity. However, the RAVEN-based analysis showed that cold leg pressure and hot leg temperature have a greater impact on the heat transfer coefficient than the mass flow rate, implying that a manual sensitivity study taking only two samples is not accurate.

20 FOSSIL-FUELED POWER PLANTS↗

EPA and Idaho National Laboratory create first of its scale

Advancing the science and engineering of decontaminating water distribution systems and safely disposing of high-volumes of contaminated water are high priorities for the EPA. To help address these science gaps, EPA homeland security researchers have developed the first-of-its-scale Water Security Test Bed (WSTB). Water is an important component of everyday life. We rely on safe, clean water for our health and the health of the environment. Protecting this vital resource is critical to living safely and securely. The U.S. Environmental Protection Agency is responsible for working with water utilities to protect water systems from contamination and to clean up systems that become contaminated. Purposeful or inadvertent distribution system contamination can result in large amounts of infrastructure and water that must be cleaned. Water distribution systems contamination can be caused by, for example, natural disasters such as Superstorm Sandy or by individuals hoping to cause harm. The WSTB, constructed at the Department of Energy’s (DOE) Idaho National Laboratory, replicates a section of a typical municipal drinking water system including a piping system with roughly 445 feet of pipe and two fire hydrants laid out in an “L” shape using 40-year-old, eight-inch cement mortar lined, ductile iron pipes, excavated after twenty years of use for water conveyance. Researchers built the WSTB above ground for easy access during experiments, and to facilitate fast leak detection. Over the next several years, EPA and partner researchers will conduct experiments using simulants of various biological, chemical, and radioactive materials that simulate high toxic versions of these agents. At this “full” sized system, researchers will demonstrate approaches to contamination detection, sensor and model testing, infrastructure decontamination, water treatment and cyber testing developed at lab and pilot scale. Researchers are also able to verify if laboratory results that were effective in controlled conditions are as effective in full-scale testing. Having the ability to conduct bench scale studies in a real world setting can help address specific research gaps, and help water researchers understand conditions in which real world drinking water systems operate.

54 ENVIRONMENTAL SCIENCES↗