Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST PROTOCOL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Third-party transfers in WLCG using HTTP

Since its earliest days, the Worldwide LHC Computational Grid (WLCG) has relied on GridFTP to transfer data between sites. The announcement that Globus is dropping support of its open source Globus Toolkit (GT), which forms the basis for several FTP client and servers, has created an opportunity to reevaluate the use of FTP. HTTP-TPC, an extension to HTTP compatible with WebDAV, has arisen as a strong contender for an alternative approach.In this paper, we describe the HTTP-TPC protocol itself, along with the current status of its support in different implementations, and the interoperability testing done within the WLCG DOMA working group’s TPC activity. This protocol also provides the first real use-case for token-based authorisation for this community. We will demonstrate the benefits of such authorisation by showing how it allows HTTP-TPC to support new technologies (such as OAuth, OpenID Connect, Macaroons and SciTokens) without changing the protocol. We will also discuss the next steps for HTTP-TPC and the plans to use the protocol for WLCG transfers.

Bockelman, Brian↗

Flux in a 1D-Reactor Cell by Response Matrix

Legacy computational reactor physics software tools and protocols currently used for support of the Advanced Test Reactor (ATR) core fuel management and safety assurance, and to some extent, experiment management, are inconsistent with the state of modern nuclear engineering practice, and are difficult, if not impossible, to verify and validate (V&V) according to modern standards. Furthermore, the legacy staff knowledge required for effective application of these tools and protocols from the 1960s and 1970s is rapidly being lost due to staff turnover and retirements. Thus in late 2009, the Idaho National Laboratory (INL) initiated a focused effort, the ATR Core Modeling Update Project, to address this situation through the introduction of modern high-fidelity transport theory based computational software and models to replace the legacy methods, with appropriate (V&V) protocols according to applicable national standards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flux in a 1D-Reactor Cell by Response Matrix

Legacy computational reactor physics software tools and protocols currently used in support of the Advanced Test Reactor (ATR) core fuel management and safety assurance, and to some extent, experiment management, are inconsistent with the state of modern nuclear engineering practice. Thus, they are difficult, if not impossible, to verify and validate (V and V) according to modern standards. Furthermore, the legacy staff knowledge required for effective application of their application and protocols from the 1960's and 1970's is rapidly being lost due to staff turnover and retirements. In late 2009, the Idaho National Laboratory (INL) initiated a focused effort, the ATR Core Modeling Update Project, to address this situation through the introduction of modern high-fidelity transport theory based computational software and models to replace the legacy methods, with appropriate (V and V) protocols according to applicable national standards. The new computational tools include: - The 2-dimensional HELIOS deterministic transport code for integrated ATR core fuel and experiment management and Core Safety Analysis Package (CSAP) physics data generation. The MCNP5 3-dimensional stochastic simulation (Monte Carlo) code for verification and validation applications and for specialized ATR core analysis along with its longstanding traditional role in experiment support - The 2-dimensional deterministic NEWT transport code and the 3-dimensional KENO6 stochastic simulation code, with their SCALE-based support infrastructure for use in V and V applications and as supporting modules for sensitivity-uncertainty analysis via the TSUNAMI system. The ATTILA 3-dimensional discrete-ordinates transport code for specialized experiment support and possibly additional applications. Regardless of application, every neutron transport code, new or legacy, requires verification. The aim of this presentation is to provide a neutron transport benchmark for a simple 1D-reactor cell in plane geometry. The benchmark finds use as a standard of comparison for the codes listed above intended for the ATR upgrade. The method developed here is in contrast to the finite Fourier transform solution found in Ref. 1, which is limited to isotropic scattering and particularly difficult to numerically implement unless the total cross section is constant over the cell.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

JLAB LLRF 3.0 Development and Tests

The Jefferson Lab LLRF 3.0 system is being developed to replace legacy LLRF systems in the CEBAF accelerator. The new design builds upon 25 years of design and operational RF control experience, and our recent collaboration in the design of the LCLSII LLRF system. The new cavity control algorithm is a fully functional phase and amplitude locked Self Exciting Loop (SEL). This paper discusses the progress of the LLRF 3.0 hardware design, FPGA firmware development, User Datagram Protocol (UDP) operation, and recent LLRF 3.0 system tests on the CEBAF Booster cryomodule in the Upgrade Injector Test Facility (UITF).

Plawski, T. E.↗

Testing nonlocality over 12.4 km of underground fiber with universal time-bin qubit analyzers

We experimentally demonstrate that the nonlocal nature of time-bin entangled photonic qubits persists when one or two qubits of the pair are converted to polarization qubits. This is possible by implementing a universal time-bin qubit analyzer (UTBA), which allows the analysis of time-bin qubits in any basis. We reveal the nonlocal nature of the emitted light by violating the Clauser-Horne-Shimony-Holt inequality with measurement bases exploring all the dimensions of the Bloch sphere. Moreover, we conduct experiments where one qubit is transmitted over a 12.4 km underground fiber link and demonstrate the suitability of our scheme for use in a real-world setting. The resulting entanglement can also be interpreted as hybrid entanglement between different types of degrees of freedom of two physical systems, which could prove useful in large-scale, heterogeneous quantum networks. This work opens possibilities for testing nonlocality and for implementing new quantum communication protocols with time-bin entanglement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metalized Polymer Current Collector for High-Energy Lithium-Ion Batteries with Extreme Fast-Charging Capability

Electric vehicles are pivotal in the global shift toward decarbonizing road transport, with lithium-ion batteries at the heart of this technological evolution. However, the pursuit of batteries capable of extremely fast charging that also satisfy high energy and safety criteria, poses a significant challenge to current lithium-ion batteries technologies. Additionally, the increasing demand for aluminum (Al) and copper (Cu) in electrification, solar energy technologies, and vehicle light-eighting is driving these metals toward near-critical status in the medium term. This study introduces metalized polythylene terephthalate (mPET) polymer films by depositing an Al or Cu thin layer onto two sides of a polyethylene terephthalate film—named mPET/Al and mPET/Cu, as lightweight, cost-effective alternatives to traditional metal current collectors in lithium-ion batteries. We have fabricated current collectors that significantly reduce weight (by 73%), thickness (by 33%), and cost (by 85%) compared with traditional metal foil counterparts. These advancements have the potential to enhance energy density to 280 Wh kg -1 at the electrode level under 10-min charging at 6 C. Through testing, including a novel extremely fast charging protocol across various C-rates and long-term cycling (up to 1000 cycles) in different cell configurations, the superior performance of these metalized polymer films has been demonstrated. Notably, mPET/Cu and mPET/Al films exhibited comparable capacities to conventional cells under extremely fast charging, with the mPET cells showing a 27% improvement in energy density at 6 C and maintaining significant energy density after 1000 cycles. This study underscores the potential of mPET films to revolutionize the roll-to-roll battery manufacturing process and significantly advance the performance metrics of lithium-ion batteries in electric vehicles applications.

25 ENERGY STORAGE↗

Total Recoverable Aluminum: Not Totally Relevant for Water Quality Standards

Abstract A large water quality data set, representing more than 100 surface-water locations sampled from 2007 to 2017 in the Los Alamos area of New Mexico, USA's Pajarito Plateau, was assembled to evaluate Al concentrations in unfiltered and filtered samples. Aluminum concentrations often exceeded United States Environmental Protection Agency (USEPA) and New Mexico ambient water quality criteria (AWQC), regardless of filter size and sample location. However, AWQC are based on laboratory toxicity studies using soluble Al salts and do not reflect natural conditions in Pajarito Plateau surface waters. The plateau is predominately covered by glassy and recrystallized volcanic ashes (e.g., Bandelier Tuff) containing colloidal to sand-sized aluminosilicates. Samples from natural background drainages and areas downstream of developed regions exhibited similar Al concentrations, suggesting that AWQC exceedances are caused by naturally elevated Al concentrations. Solubility calculations indicated that most samples were oversaturated with respect to amorphous Al(OH)3(s). Therefore, AWQC exceedances are likely artifacts of the “total recoverable” sample preparation, which includes acidification and partial digestion, thereby liberating nonbioavailable Al from aluminosilicates. Accordingly, Al concentrations were strongly associated with suspended sediment concentrations (SSCs), implying that aluminosilicates in suspended sediment contributed to AWQC exceedances and Al oversaturation. Solid-phase particle characterization, using X-ray diffraction (XRD) and scanning electron microscopy with electron dispersive spectroscopy (SEM/EDS) did not identify potentially bioavailable amorphous Al(OH)3(s) in any sample tested. Thus, current sample collection and analysis protocols should not be used to evaluate attainment of Al AWQC on the Pajarito Plateau or locations where aluminosilicates are substantial contributors to total recoverable Al. A sample preparation method (e.g., pH 4 extraction) capable of differentiating nonbioavailable and bioavailable forms of Al is recommended. Otherwise, current New Mexico and USEPA sample preparation approaches will continue to generate artifactual AWQC exceedances in surface waters that contain aluminosilicates. Integr Environ Assess Manag 2019;00:1–14. © 2019 SETAC

Ryan, Adam C.↗

A metabolic modeling platform for the computation of microbial ecosystems in time and space (COMETS)

Genome-scale stoichiometric modeling of metabolism has become a standard systems biology tool for modeling cellular physiology and growth. Extensions of this approach are emerging as a valuable avenue for predicting, understanding and designing microbial communities. Computation of microbial ecosystems in time and space (COMETS) extends dynamic flux balance analysis to generate simulations of multiple microbial species in molecularly complex and spatially structured environments. Here we describe how to best use and apply the most recent version of COMETS, which incorporates a more accurate biophysical model of microbial biomass expansion upon growth, evolutionary dynamics and extracellular enzyme activity modules. In addition to a command-line option, COMETS includes user-friendly Python and MATLAB interfaces compatible with the well-established COBRA models and methods, as well as comprehensive documentation and tutorials. Overall, this protocol provides a detailed guideline for installing, testing and applying COMETS to different scenarios, generating simulations that take from a few minutes to several days to run, with broad applicability to microbial communities across biomes and scales.

59 BASIC BIOLOGICAL SCIENCES↗

CR mammography: Design and implementation of a quality control program

Despite the recent acquisition of significant quantities of computed radiography CR equipment for mammography, Mexican regulations do not specify the performance requirements for digital systems such as those of CR type. The design of a quality control program QCP specific for CR mammography systems was thus considered relevant. International protocols were taken as reference to define tests, procedures and acceptance criteria. The designed QCP was applied in three CR mammography facilities. Important deficiencies in spatial resolution, noise, image receptor homogeneity, artifacts and breast thickness compensation were detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose

Purpose: X-ray scatter is a major detriment to image quality in cone-beam CT (CBCT). Existing geometries exhibit strong differences in scatter susceptibility with more compact geometries, e.g., dental or musculoskeletal, benefiting from antiscatter grids, whereas in more extended geometries, e.g., IGRT, grid use carries tradeoffs in image quality per unit dose. This work assesses the tradeoffs in dose and image quality for grids applied in the context of low-dose CBCT on a mobile C-arm for image-guided surgery. Methods: Studies were performed on a mobile C-arm equipped with a flat-panel detector for high-quality CBCT. Antiscatter grids of grid ratio (GR) 6:1-12:1, 40 lp/cm, were tested in ''body'' surgery, i.e., spine, using protocols for bone and soft-tissue visibility in the thoracic and abdominal spine. Studies focused on grid orientation, CT number accuracy, image noise, and contrast-to-noise ratio (CNR) in quantitative phantoms at constant dose. Results: There was no effect of grid orientation on possible gridline artifacts, given accurate angle-dependent gain calibration. Incorrect calibration was found to result in gridline shadows in the projection data that imparted high-frequency artifacts in 3D reconstructions. Increasing GR reduced errors in CT number from 31%, thorax, and 37%, abdomen, for gridless operation to 2% and 10%, respectively, with a 12:1 grid, while image noise increased by up to 70%. The CNR of high-contrast objects was largely unaffected by grids, but low-contrast soft-tissues suffered reduction in CNR, 2%-65%, across the investigated GR at constant dose. Conclusions: While grids improved CT number accuracy, soft-tissue CNR was reduced due to attenuation of primary radiation. CNR could be restored by increasing dose by factors of {approx}1.6-2.5 depending on GR, e.g., increase from 4.6 mGy for the thorax and 12.5 mGy for the abdomen without antiscatter grids to approximately 12 mGy and 30 mGy, respectively, with a high-GR grid. However, increasing the dose poses a significant impediment to repeat intraoperative CBCT and can cause the cumulative intraoperative dose to exceed that of a single diagnostic CT scan. This places the mobile C-arm in the category of extended CBCT geometries with sufficient air gap for which the tradeoffs between CNR and dose typically do not favor incorporation of an antiscatter grid.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Significant Improvements to Si Calendar Lifetime Using Rapid Electrolyte Screening via Potentiostatic Holds

Silicon-based lithium-ion batteries exhibit severe time-based degradation resulting in poor calendar lives. This has been identified as the major impediment towards commercialization with cycle life considered a solved issue through nanosizing and protective coatings allowing over 1000 cycles of life to be achieved. In this work, rapid screening of sixteen electrolytes for calendar life extension of Si-rich systems (70 wt% Si) is performed using the voltage hold (V-hold) protocol. V-hold significantly shortens the testing duration over the traditional open circuit voltage reference performance test allowing us to screen electrolytes within a span of two months. We find a novel ethylene carbonate (EC) free electrolyte formulation containing lithium hexafluorophosphate (LiPF 6 ) salt, and binary solvent mix of fluoroethylene carbonate (FEC), ethyl methyl carbonate (EMC) that extends calendar life of Si cells as compared to conventional EC based electrolyte. Our coupled experimental-theoretical analysis framework provides a decoupling of the parasitic currents during V-hold, allowing us to extrapolate the capacity loss to predict semiquantitative calendar lifetimes. Subsequently, cycle aging and oxidative stability tests of the EC free system also show enhanced performance over baseline electrolyte.

25 ENERGY STORAGE↗

Time-lapse Fluorescence Imaging of Arabidopsis Root Growth with Rapid Manipulation of The Root Environment Using The RootChip

The root functions as the physical anchor of the plant and is the organ responsible for uptake of water and mineral nutrients such as nitrogen, phosphorus, sulfate and trace elements that plants acquire from the soil. If we want to develop sustainable approaches to producing high crop yield, we need to better understand how the root develops, takes up a wide spectrum of nutrients, and interacts with symbiotic and pathogenic organisms. To accomplish these goals, we need to be able to explore roots in microscopic detail over time periods ranging from minutes to days. We developed the RootChip, a polydimethylsiloxane (PDMS)- based microfluidic device, which allows us to grow and image roots from Arabidopsis seedlings while avoiding any physical stress to roots during preparation for imaging1 (Figure 1). The device contains a bifurcated channel structure featuring micromechanical valves to guide the fluid flow from solution inlets to each of the eight observation chambers2 . This perfusion system allows the root microenvironment to be controlled and modified with precision and speed. The volume of the chambers is approximately 400 nl, thus requiring only minimal amounts of test solution. Here we provide a detailed protocol for studying root biology on the RootChip using imaging-based approaches with real time resolution. Roots can be analyzed over several days using time lapse microscopy. Roots can be perfused with nutrient solutions or inhibitors, and up to eight seedlings can be analyzed in parallel. This system has the potential for a wide range of applications, including analysis of root growth in the presence or absence of chemicals, fluorescence-based analysis of gene expression, and the analysis of biosensors, e.g. FRET nanosensors3.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of storage and extraction methods on peat soil microbiomes

Recovered microbial community structure is known to be influenced by sample storage conditions and nucleic acid extraction methods, and the impact varies by sample type. Peat soils store a large portion of soil carbon and their microbiomes mediate climate feedbacks. Here, we tested three storage conditions and five extraction protocols on peat soils from three physicochemically distinct habitats in Stordalen Mire, Sweden, revealing significant methodological impacts on microbial (here, meaning bacteria and archaea) community structure. Initial preservation method impacted alpha but not beta diversity, with in-field storage in LifeGuard buffer yielding roughly two-thirds the richness of in-field flash-freezing or transport from the field on ice (all samples were stored at −80 °C after return from the field). Nucleic acid extraction method impacted both alpha and beta diversity; one method (the PowerSoil Total RNA Isolation kit with DNA Elution Accessory kit) diverged from the others (PowerMax Soil DNA Isolation kit-High Humic Acid Protocol, and three variations of a modifiedPowerMax Soil DNA/RNA isolation kit), capturing more diverse microbial taxa, with divergent community structures. Although habitat and sample depth still consistently dominated community variation, method-based biases in microbiome recovery for these climatologically-relevant soils are significant, and underscore the importance of methodological consistency for accurate inter-study comparisons, long-term monitoring, and consistent ecological interpretations.

Science & Technology - Other Topics↗

Exercise response

The bicycle ergometer and a graded stress protocol were used to conduct exercise stress tests for the Apollo project. The graded exercise tests permitted a progressive evaluation of physiological control system response and provided a better understanding of safe stress limits; heart rate was used for determining stress levels. During each test, workload, heart rate, blood pressure, and respiratory gas exchange (oxygen consumption, carbon dioxide production, and minute volume) measurements were made. The results are presented and discussed.

J.A. Rummel↗

Measurement of cardiopulmonary performance during acute exposure to a 2440-m equivalent atmosphere

Each of 20 subjects (ranging in age from 18 to 38 years, 15 being male, five female) was given two Bruce Protocol symptom-limited maximum treadmill stress tests, breathing sea-level compressed air (20.9% O2) for one test and a 2440-m equivalent (15.5% O2) for the other. A significant difference was found to exist between measured VO2 max (p less than 0.0002) and exercise time (p less than 0.0004) for the two conditions. No significant differences were observed in heart rate or the recovery time to a respiratory quotient of less than 1. Hemoglobin saturation, as measured by an ear oximeter, averaged 95% for sea-level and 91% for the 2440-m equivalent gases. These results support a 2440-m equivalent contingency atmosphere in the Space Shuttle prior to donning a low-pressure suit for the purpose reducing nitrogen washout times.

Levitan, B. M.↗

Work, exercise, and space flight. 3: Exercise devices and protocols

Preservation of locomotor capacity by earth equivalent, exercise in space is the crucial component of inflight exercise. At this time the treadmill appears to be the only way possible to do this. Work is underway on appropriate hardware but this and a proposed protocol to reduce exercise time must be tested. Such exercise will preserve muscle, bone Ca(++) and cardiovascular-respiratory capacity. In addition, reasonable upper body exercise can be supplied by a new force generator/measurement system-optional exercise might include a rowing machine and bicycle ergometer. A subject centered monitoring-evaluation program will allow real time adjustments as required. Absolute protection for any astronaut will not be possible and those with hypertrophied capacities such as marathoners or weight lifters will suffer significant loss. However, the program described should return the crew to earth with adequate capacity of typical activity on earth including immediate ambulation and minimal recovery time and without permanent change. An understanding of the practical mechanics and biomechanics involved is essential to a solution of the problem.

Thornton, William↗