Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Assessments of Hollow Cathode Wear in the Xenon Ion Propulsion System (XIPs(c)) by Numerical Analyses and Wear Tests

The standard approach presently followed by NASA to qualify electric propulsion for the required mission throughput has been based largely on life tests, which can be costly and time consuming. Revised electric propulsion lifequalification approaches are being formulated that combine analytical and/or computational methods with (shorter-duration) wear tests. As a model case, a wear test is being performed at JPL to assess the lifetime of the discharge hollow cathode in the Xenon Ion Propulsion System (XIPS(c)), a 25-cm ion engine developed by L-3 Communications Electron Technologies, Inc. for commercial applications. Wear and plasma data accumulated throughout this life-assessment program are being used to validate the existing 2-D hollow cathode code OrCa2D. We find that the OrCa2D steady-state solution predicts very well the time-averaged plasma data and the keeper voltage after 5500 hrs of operation in high-power mode. When the wave motion that occurs naturally in these devices is accounted for, based on an estimate of the maximum wave amplitude, the molybdenum-keeper erosion profile observed in the XIPS(c) discharge cathode is also reproduced within a factor of two of the observation. When the same model is applied to predict the erosion of a tantalum keeper we find that erosion is reduced by more than two orders of magnitude compared to the molybdenum keeper due the significantly lower sputtering yield of tantalum. A tantalum keeper would therefore allow keeper lifetimes that greatly exceed the present requirements for deep-space robotic missions considered by NASA. Moreover, such large reduction of the erosion renders the largest uncertainties in the models, which are associated with the wave amplitude estimates and the electron transport model, negligible.

plasma simulations↗

Standards Development Activities at White Sands Test Facility

The development of standards and standard activities at the JSC White Sands Test Facility (WSTF) has been expanded to include the transfer of technology and standards to voluntary consensus organizations in five technical areas of importance to NASA. This effort is in direct response to the National Technology Transfer Act designed to accelerate transfer of technology to industry and promote government-industry partnerships. Technology transfer is especially important for WSTF, whose longterm mission has been to develop and provide vital propellant safety and hazards information to aerospace designers, operations personnel, and safety personnel. Meeting this mission is being accomplished through the preparation of consensus guidelines and standards, propellant hazards analysis protocols, and safety courses for the propellant use of hydrogen, oxygen, and hypergols, as well as the design and inspection of spacecraft pressure vessels and the use of pyrovalves in spacecraft propulsion systems. The overall WSTF technology transfer program is described and the current status of technology transfer activities are summarized.

Baker, D. L.↗

Characterization Testing of Lockheed Martin Standard Micro Pulse Tube Cryocooler

This paper describes the thermal performance, exported vibration, and magnetics testing and results of a Lockheed Martin standard micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 150 and 300 K. The cooler was driven with Thales XPCDE4865 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 84 and 98 Hz. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the exported forces and torques of the cooler were measured with the cooler driven by Thales CDE7232 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 88 and 96 Hz. The exported forces were dependent on both input power and drive frequency. Moreover, the automatic vibration reduction function of the drive electronics was able to decrease the force in the compressor axis to below 10 mN 0-peak. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

McKinley, I. M.↗

PMK 1000 cone-socket ventilator fittings force testing to ISO 5356-1:2015 Standard

This memo summarizes the results of verification tests on a cone-socket fitting to the ISO 5356-1:2015 standard, annexes B and F. The components were found to meet requirements holding 50N tensile force and more than 35 N-cm of torque for 10 seconds without separating at 35°C with a fresh socket. Humidity control was unavailable; consequently, humidity was significantly lower than the values in the ISO standard. Several repeat tests of the fitting with force, torque, and time excursions give us confidence that the fittings perform suitably to the ISO standard. Force overload tests suggest that the samples will disengage under tension at around 69 N, while torque overload tests under a force of 50 N will fail at 79 N-cm of torque. If repeated tests are performed on the same component, the socket can deform and lead to the connection failing the standard requirements. However, such failures only occur with repeated testing, and the gripping of such units can be modified so that they pass the standard. This observation demonstrates that socket gripping is responsible for those failures and would not be a problem in application.

42 ENGINEERING↗

Effects of knock intensity measurement technique and fuel chemical composition on the research octane number (RON) of FACE gasolines: Part 1 – Lambda and knock characterization

The Research and Motor Octane Number (RON and MON) rate the knock propensity of gasoline in the Cooperative Fuel Research (CFR) engine by comparing the knock intensity of sample fuels relative to that of primary reference fuels (PRF), a binary blend of iso-octane and n-heptane. Important differences exist between standard octane testing and automotive spark ignition (SI) engine knock testing including speed, load, air-to-fuel equivalence ratio (lambda), and knock characterization, which lead to a discrepancy between a fuel’s RON rating and its knock resistance characterized on an automotive SI engine based on knock-limited spark advance. This publication is the first of a set of three publications which modify operating parameters of the RON test method (ASTM D2699) to investigate the effects of these differences with automotive SI engine knock-limited spark advance testing. A fuel’s standard RON is evaluated at the lambda of the highest knock intensity, whereas automotive SI engines typically operate at stoichiometry. Here, we analyze the effects of a stoichiometric RON rating methodology. Additionally, the knock intensity response from the standard CFR knockmeter system is compared to a cylinder pressure oscillation-based knock intensity at several lambda settings. All experiments were performed with a set of seven Coordinating Research Council (CRC) Fuels for Advanced Combustion Engines (FACE) gasolines with approximately 95 RON. The fuel chemical composition impacted the lambda of the highest knock intensity, which resulted in fuel-specific offsets between the standard and stoichiometric RON ratings. The knock system comparison showed significant offsets between cylinder pressure-based and knockmeter-based knock intensity levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid polystyrene and deuterated polystyrene light output response to fast neutrons

The Neutron Imaging System has proven to be an important diagnostic in studying DT implosion characteristics at the National Ignition Facility. Here, the current system depends on a polystyrene scintillating fiber array, which detects fusion neutrons born in the DT hotspot as well as neutrons that have scattered to lower energies in the surrounding cold fuel. Increasing neutron yields at NIF, as well as a desire to resolve three-dimensional information about the fuel assembly, have provided the impetus to build and install two additional next-generation neutron imaging systems. We are currently investigating a novel neutron imaging system that will utilize a deuterated polystyrene (CD) fiber array instead of standard hydrogen-based polystyrene (CH). Studies of deuterated xylene or deuterated benzene liquid scintillator show an improvement in imaging resolution by a factor of two, but also a reduction in light output as compared to standard plastic. Tests of the relative light output of deuterated polystyrene and standard polystyrene were completed using 14 MeV fusion neutrons generated through implosions of deuterium-tritium filled capsules at the OMEGA laser facility. In addition, we collected data of the relative response of these two scintillators to a wide energy range of neutrons (1-800 MeV) at the Weapons Neutrons Research Facility. Results of these measurements are presented.

47 OTHER INSTRUMENTATION↗

Effects of Muscle Atrophy on Motor Control: Cage-size Effects

Two populations of male Sprague-Dawley rats were raised either in conventional minimum-specification cages or in a larger cage. When the animals were mature (125 to 150 d), the physiological status of the soleus (SOL) and extensor digitorum longus (EDL) muscles of the small- and large-cage animals were compared. Analysis of whole-muscle properties including the performance of the test muscle during a standardized fatigue test in which the nerve to the test muscle was subjected to supramaximal intermittent stimulation shows: (1) the amplitude, area, mean amplitude, and peak-to-peak rate of the compound muscle action potential decreased per the course of the fatigue test; (2) cage size did not affect the profile of changes for any of the action-potential measurements; (3) changes exhibited in the compound muscle action potential by SOL and EDL were substantially different; and (4) except for SOL of the large-cage rats, there was a high correlation between all four measures of the compound muscle action potential and the peak tetanic force during the fatigue test; i.e., either the electrical activity largely etermines the force profile during the fatigue test or else contractile-related activity substantially affects the compound muscle action potential.

Stuart, D. G.↗

Coupled Aerodynamic-Thermal-Structural (CATS) Analysis

Coupled Aerodynamic-Thermal-Structural (CATS) Analysis is a focused effort within the Numerical Propulsion System Simulation (NPSS) program to streamline multidisciplinary analysis of aeropropulsion components and assemblies. Multidisciplinary analysis of axial-flow compressor performance has been selected for the initial focus of this project. CATS will permit more accurate compressor system analysis by enabling users to include thermal and mechanical effects as an integral part of the aerodynamic analysis of the compressor primary flowpath. Thus, critical details, such as the variation of blade tip clearances and the deformation of the flowpath geometry, can be more accurately modeled and included in the aerodynamic analyses. The benefits of this coupled analysis capability are (1) performance and stall line predictions are improved by the inclusion of tip clearances and hot geometries, (2) design alternatives can be readily analyzed, and (3) higher fidelity analysis by researchers in various disciplines is possible. The goals for this project are a 10-percent improvement in stall margin predictions and a 2:1 speed-up in multidisciplinary analysis times. Working cooperatively with Pratt & Whitney, the Lewis CATS team defined the engineering processes and identified the software products necessary for streamlining these processes. The basic approach is to integrate the aerodynamic, thermal, and structural computational analyses by using data management and Non-Uniform Rational B-Splines (NURBS) based data mapping. Five software products have been defined for this task: (1) a primary flowpath data mapper, (2) a two-dimensional data mapper, (3) a database interface, (4) a blade structural pre- and post-processor, and (5) a computational fluid dynamics code for aerothermal analysis of the drum rotor. Thus far (1) a cooperative agreement has been established with Pratt & Whitney, (2) a Primary Flowpath Data Mapper has been prototyped and delivered to General Electric Aircraft Engines and Pratt & Whitney for evaluation, (3) a collaborative effort has been initiated with the National Institute of Standards and Testing to develop a Standard Data Access Interface, and (4) a blade tip clearance capability has been implemented into the Structural Airfoil Blade Engineering Routine (SABER) program. We plan to continue to develop the data mappers and data management tools. As progress is made, additional efforts will be made to apply these tools to propulsion system applications.

Source record↗

Coupled Facility/Payload Vibration Modeling Improvements

A major phase of aerospace hardware verification is vibration testing. The standard approach for such testing is to use a shaker to induce loads into the payload. In preparation for vibration testing at NASA/GSFC there is an analysis to assess the responses of the payload. A new method of modeling the test is presented that takes into account dynamic interactions between the facility and the payload. This dynamic interaction has affected testing in the past, but been ignored or adjusted for during testing. By modeling the combination of the facility and test article (payload) it is possible to improve the prediction of hardware responses. Many aerospace test facilities work in similar way to those at NASA Goddard Space Flight Center. Lessons learned here should be applicable to other test facilities with similar setups.

Finite Element Analysis↗

Coupled Facility-Payload Vibration Modeling Improvements

A major phase of aerospace hardware verification is vibration testing. The standard approach for such testing is to use a shaker to induce loads into the payload. In preparation for vibration testing at National Aeronautics and Space Administration/Goddard Space Flight Center an analysis is performed to assess the responses of the payload. A new method of modeling the test is presented that takes into account dynamic interactions between the facility and the payload. This dynamic interaction has affected testing in the past, but been ignored or adjusted for during testing. By modeling the combined dynamics of the facility and test article (payload) it is possible to improve the prediction of hardware responses. Many aerospace test facilities work in similar way to those at NASA/Goddard Space Flight Center. Lessons learned here should be applicable to other test facilities with similar setups.

Finite Element Analysis↗

Field Testing Research at the NWTC (Fact Sheet)

The National Wind Technology Center (NWTC) at the National Renewable Laboratory (NREL) has extensive field testing capabilities that have been used in collaboration with the wind industry to accelerate wind technology development and deployment for more than 30 years.

17 WIND ENERGY↗

Proceedings of the Advisory Committee on Standardization of Carbon-Phenolic Test Methods and Specifications

Proceedings of the Advisory Committee on Standardization of carbon-phenolic test methods and specifications are compiled. The following subject areas are covered: ashing procedures and alkali metal content of carbon fiber and fabrics; SPIP product identification code; SPIP initiative to adopt a water-soluble rayon yarn lubricant/size for weaving; fabric oxidation mass loss test; shelf life limit for prepregs, industry standard; silicon contamination update; resin, filler, and fabric content in prepreg; carbon assay testing calibration; thiokol rayon specifications; and SPIP low conductivity PAN program.

Hall, William B.↗

Enabling reliability assessments of pre-commercial perovskite photovoltaics with lessons learned from industrial standards [Enabling reliability of pre-commercial perovskite photovoltaics with lessons learned from industrial standards]

Here, photovoltaic modules are expected to operate in the field for more than 25 years, so reliability assessment is critical for the commercialization of new photovoltaic technologies. In early development stages, understanding and addressing the device degradation mechanisms are the priorities. However, any technology targeting large-scale deployment must eventually pass industry-standard qualification tests and undergo reliability testing to validate the module lifetime. In this Perspective, we review the methodologies used to assess the reliability of established photovoltaics technologies and to develop standardized qualification tests. We present the stress factors and stress levels for degradation mechanisms currently identified in pre-commercial perovskite devices, along with engineering concepts for mitigation of those degradation modes. Recommendations for complete and transparent reporting of stability tests are given, to facilitate future inter-laboratory comparisons and to further the understanding of field-relevant degradation mechanisms, which will benefit the development of accelerated stress tests.

14 SOLAR ENERGY↗

An International Round-Robin Study on Thermoelectric Module Testing and Development of Standard Power Generation Modules

An international round-robin study on thermoelectric power generation modules was conducted with nine participating laboratories. Two types of commercially available bismuth telluride modules, 30 mm × 30 mm and 40 mm × 40 mm, were used. A test protocol was followed with five temperature set points from 50°C to 150°C. Graphite sheets were used as thermal interface materials with test pressure at 100 psi (0.69 MPa). The results showed large lab-to-lab variations and the key source of uncertainty for module efficiency was identified as the heat flux measurement. In the meantime, significant uncertainty was also found in maximum electrical power (P max ) measurements. As a result of the round-robin, a “standard module” with 4 × 4 legs on a 20 mm × 20 mm platform was suggested. A skutterudite module and a half-Heusler module were produced with identical geometry and 4 mm × 4 mm × 8 mm legs. All transport properties to calculate the figure-of-merit, zT, were measured from ambient temperature to 500°C. Module performance was measured by two laboratories. Two finite-element-analysis (FEA)-based models were developed independently to simulate and predict the module performance. In conclusion, the standard modules eliminated significant test uncertainties and are aimed at assisting device design and achieving more accurate performance predictions.

Round-robin↗

Comparison tests and experimental compliance calibration of the proposed standard round compact plane strain fracture toughness specimen

Standard round specimen fracture test results compared satisfactorily with results from standard rectangular compact specimens machined from the same material. The location of the loading pin holes was found to provide adequate strength in the load bearing region for plane strain fracture toughness testing. Excellent agreement was found between the stress intensity coefficient values obtained from compliance measurements and the analytic solution proposed for inclusion in the standard test method. Load displacement measurements were made using long armed displacement gages and hollow loading cylinders. Gage points registered on the loading hole surfaces through small holes in the walls of the loading cylinders.

Fisher, D. M.↗

POTATO: A Unified Assessment System for HL-LHC Outer Tracker Module Productions

The CMS detector s silicon tracker will be replaced in preparation for the upcoming High-Luminosity LHC (HL LHC) upgrade. The inner tracker will include a new pixel detector while the outer tracker (OT) will feature 5,592 pixel strip (PS) and 7,608 strip strip (2S) sensor modules with production distributed across 7 sites worldwide, requiring standardized grading and testing. One testing apparatus the burn-in box replicates the temperature cycling conditions that successful modules must withstand. The Phase-II Outer Tracker Analyzer of Test Outputs (POTATO) standardizes module evaluation and grading among testing sites. Given burn-in box test output, POTATO analyzes the results and assigns a letter grade to a module and its sub-components. POTATO's grading process must adapt to evolving standards for module evaluation; hence, we detail work on POTATO's database and grading functionality that will facilitate the unified assessment of Phase-II OT module assembly and testing worldwide. Once completed, POTATO will allow technicians to interact with a database of all graded modules and efficiently assess the global module assembly effort.

Clark, Olivia J. [U. Tennessee, Knoxville]↗

A proposed standard round compact specimen for plane strain fracture toughness testing

A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

Underwood, J. H.↗

ASTM Committee C28: International Standards for Properties and Performance of Advanced Ceramics-Three Decades of High-Quality, Technically-Rigorous Normalization

Physical and mechanical properties and performance of advanced ceramics and glasses are difficult to measure correctly without the proper techniques. For over three decades, ASTM Committee C28 on Advanced Ceramics, has developed high-quality, technically-rigorous, full-consensus standards (e.g., test methods, practices, guides, terminology) to measure properties and performance of monolithic and composite ceramics that may be applied to glasses in some cases. These standards contain testing particulars for many mechanical, physical, thermal, properties and performance of these materials. As a result these standards are used to generate accurate, reliable, repeatable and complete data. Within Committee C28, users, producers, researchers, designers, academicians, etc. have written, continually updated, and validated through round-robin test programs, 50 standards since the Committee's founding in 1986. This paper provides a detailed retrospective of the 30 years of ASTM Committee C28 including a graphical pictogram listing of C28 standards along with examples of the tangible benefits of standards for advanced ceramics to demonstrate their practical applications.

properties↗