Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions

This article reports on the development and application of a Thomson parabola (TP) equipped with a (90x70) mm{sup 2} microchannel-plate (MCP) for the analysis of laser-accelerated ions, produced by a high-energy, high-intensity laser system. The MCP allows an online measurement of the produced ions in every single laser shot. An electromagnet instead of permanent magnets is used that allows the tuning of the magnetic field to adapt the field strength to the analyzed ion species and energy. We describe recent experiments at the 100 TW laser facility at the Laboratoire d'Utilization des Lasers Intenses (LULI) in Palaiseau, France, where we have observed multiple ion species and charge states with ions accelerated up to 5 MeV/u (O{sup +6}), emitted from the rear surface of a laser-irradiated 50 {mu}m Au foil. Within the experiment the TP was calibrated for protons and for the first time conversion efficiencies of MeV protons (2-13 MeV) to primary electrons (electrons immediately generated by an ion impact onto a surface) in the MCP are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volumetric system calibrates meters for large flow rates

Volumetric system calibrates meters used for large liquid flow rates. The system employs trip probes and equipment to time the flow of liquid from a tare vessel into a calibrated vessel. This calibration system is used in the petroleum and chemical industries.

Source record↗

Detection of melting by X-ray imaging at high pressure

The occurrence of partial melting at elevated pressure and temperature is documented in real time through measurement of volume strain induced by a fixed temperature change. Here we present the methodology for measuring volume strains to one part in 10{sup −4} for mm{sup 3} sized samples in situ as a function of time during a step in temperature. By calibrating the system for sample thermal expansion at temperatures lower than the solidus, the onset of melting can be detected when the melting volume increase is of comparable size to the thermal expansion induced volume change. We illustrate this technique with a peridotite sample at 1.5 GPa during partial melting. The Re capsule is imaged with a CCD camera at 20 frames/s. Temperature steps of 100 K induce volume strains that triple with melting. The analysis relies on image comparison for strain determination and the thermal inertia of the sample is clearly seen in the time history of the volume strain. Coupled with a thermodynamic model of the melting, we infer that we identify melting with 2 vol.% melting.

36 MATERIALS SCIENCE↗

Status of the Shuttle SBUV (SSBUV) calibration of the NOAA SBUV/2 operational ozone sounders and the detection of trends

The Shuttle Solar Backscatter Ultraviolet (SSBUV) experiment has flown four times since October 1989. The purpose of SSBUV is to perform calibration checks of the SBUV ozone sounding instruments on the Nimbus and NOAA satellites in order to remove calibration drift so that ozone trends in the middle stratosphere can be accurately derived. Calibration checks are performed by comparing coincident observations between SSBUV and the satellite instruments. Regular flights of about once per year and maintenance of the SSBUV calibration to 1 percent from flight to flight are the major challenges for SSBUV. To date the required flight frequency has been met and instrument calibration is known to about 1-2 percent for the first three flights. The first comparisons showed 30 percent differences between SSBUV and the original archived Nimbus SBUV data, but considerably smaller differences with the new SBUV 'Version 6' data. Differences between SSBUV and SBUV/2 instruments on NOAA-11 and NOAA-9 were of the order of 5-10 percent respectively. These differences have not been accounted for in the present NOAA data set since they contain initial calibration biases as well as long term instrument drift. With subsequent SSBUV comparisons, the satellite calibration can be corrected, which will then allow an accurate estimate of ozone trends in the upper stratosphere. In this initial study, 1989 Nimbus-7 SBUV data have been corrected using SSBUV observations and then compared to SBUV data for 1980. This comparison then leads to an ozone trend of 7 percent in the upper stratosphere over the tropics for the period 1980 to 1989.

Hilsenrath, Ernest↗

Measurements of Picosecond Energy Equilibration in Isochorically Heated Materials

In this Final Report we present the results of our DOE/FES-sponsored research on rapidly heated materials. The research focused on the details of picosecond energy equilibration and material response to isochoric heating by relativistic (or “hot”) electrons. The major goal was to improve the understanding of these processes by making time-resolved extreme ultraviolet (XUV) measurements of ultrafast energy deposition and blast-wave formation for testing impulsive-heating models in extreme thermodynamic conditions. Major achievements of the project include the design, fabrication, deployment, and use of two XUV spectrometers on the Multi-Terawatt (MTW) Laser System at the University of Rochester’s Laboratory for Laser Energetics. One of the spectrometers is coupled to an x-ray charge-coupled device (CCD) for time-integrated measurements; the other is coupled to an ultrafast x-ray streak camera for time-resolved measurements. Working together, these instruments provide absolutely calibrated data on the emitted XUV spectrum from an isochoric heated target. The new diagnostic system was used to measure and infer the time-resolved rear-surface temperature and density for different target materials and different target-interaction conditions. Experiments with laser-heated metal foils measured the ultrafast dynamics and energy deposition from hot electrons into plasma heating and blast-wave formation. The blast wave was observed emerging from the rear surface of the laser-irradiated target. The time between the prompt emission (electron-driven x-ray emission) and the blast-wave arrival was used to estimate the energy deposition into the wave. The data are consistent with a Sedov–Taylor blast wave, with energy transfer from the laser to the blast of up to 20 mJ. The data represent the first quantitative assessment of the blast-wave energy in a metal following heating by a short burst of high-intensity laser-generated hot electrons. The funding from this grant provided significant opportunities for training and professional development. The grant supported or partially supported a graduate student, a postdoctoral research associate, and a senior staff scientist. This support included bringing together a dedicated group of individuals with a niche set of experimental and theoretical skills for studying advanced material properties experiments and ultrafast radiation conditions. The team dynamic fostered training and knowledge transfer across the whole spectrum of research activities through shared experiences in advanced laboratory techniques, data analysis, modeling, and the development of new ideas, techniques, presentations, and publications. The results of this work, which significantly improve the understanding of rapid energy deposition in solid matter, have been widely disseminated to communities of interest through invited talks, contributed talks, and peer-reviewed journals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2016 NIST ( 133 Xe) and Transfer ( 131m Xe, 133m Xe, 135 Xe) Calibration Report

A significantly improved calibration of the High Purity Germanium detectors used by the Idaho National Laboratory Noble Gas Laboratory was performed during the annual NIST calibration. New sample spacers provide reproducible and secure support of samples at distances of 4, 12, 24, 50 and 100 cm. Bean, 15mL and 50mL Schlenk tube geometries were calibrated. Also included in this year’s calibration was a correlation of detector dead-time with sample activity that can be used to predict the schedule of counting the samples at each distance for each geometry. This schedule prediction will help staff members set calendar reminders so that collection of calibration data at each geometry will not be missed. This report also correlates the counting efficiencies between detectors, so that if the counting efficiency on one detector is not known, it can be estimated from the same geometry on another detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lunar microcraters and interplanetary dust fluxes

Conflicting depth/diameter ratios reported for lunar microcrater pits, microcrater pit morphology and size distribution, the composition and structure of pit glasses, and various alternative 'clocks' for estimating exposure time of microcrater pits are examined. Surface exposure time 'clocks' discussed include: galactic cosmic ray tracks, cosmogenic nuclides (involving changes in host rock isotopic composition induced by nuclear reactions), tracks produced in lunar top surfaces by nuclei accelerated during solar flares, and solar wind sputtering. 'Calibration' of the disparate types of surface exposure time 'clocks' with one another is discussed. The sensitive relationship between determinations of meteoroid flux and surface exposure time is examined.

Hartung, J. B.↗

Long Duration Exposure Facility (LDEF) attitude measurements of the interplanetary dust experiment

The Long Duration Exposure Facility (LDEF) Interplanetary Dust Experiment (IDE) was unique in providing a time history of impacts of micron-sized particles on six orthogonal faces of LDEF during the first year in orbit. The value of this time resolved data depended on and was enhanced by the proper operation of some basic LDEF systems. Thus, the value of the data is greatly enhanced when the location and orientation of LDEF is known for each time of impact. The location and velocity of LDEF as a function of time can be calculated from the 'two-line elements' published by GSFC during the first year of the LDEF mission. The attitude of LDEF was passively stabilized in a gravity-gradient mode and a magnetically anchored viscous damper was used to dissipate roll, pitch, and yaw motions. Finally, the IDE used a standard LDEF Experiment Power and Data System (EPDS) to collect and store data and also to provide a crystal derived clock pulse (1 count every 13.1072 seconds) for all IDE time measurements. All that remained for the IDE was to provide a system to calibrate the clock, eliminating accumulative errors, and also verify the attitude of LDEF. The IDE used solar cells on six orthogonal faces to observe the LDEF sunrise and provide data about the LDEF attitude. The data was recorded by the EPDS about 10 times per day for the first 345 days of the LDEF mission. This data consist of the number of IDE counts since the last LDEF sunrise and the status of the six solar cells (light or dark) at the time of the last IDE count. The EPDS determined the time that data was recorded and includes, with each record, the master EPDS clock counter (1 count every 1.6384 seconds) that provided the range and resolution for time measurements. The IDE solar cells provided data for an excellent clock calibration, meeting their primary purpose, and the time resolved LDEF attitude measurements that can be gleaned from this data are presented.

Kassel, Philip C., Jr.↗

Ecosystem biogeochemistry model parameterization: Do more flux data result in a better model in predicting carbon flux?

Reliability of terrestrial ecosystem models highly depends on the quantity and quality of thedata that have been used to calibrate the models. Nowadays, in situ observations of carbon fluxes areabundant. However, the knowledge of how much data (data length) and which subset of the time seriesdata (data period) should be used to effectively calibrate the model is still lacking. This study uses theAmeriFlux carbon flux data to parameterize the Terrestrial Ecosystem Model (TEM) with an adjoint-baseddata assimilation technique for various ecosystem types. Parameterization experiments are thus conductedto explore the impact of both data length and data period on the uncertainty reduction of the posteriormodel parameters and the quantification of site and regional carbon dynamics. We find that: the modelis better constrained when it uses two-year data comparing to using one-year data. Further, two-year datais sufficient in calibrating TEM’s carbon dynamics, since using three-year data could only marginallyimprove the model performance at our study sites; the model is better constrained with the data thathave a higher‘‘climate variability’’than that having a lower one. The climate variability is used to measurethe overall possibility of the ecosystem to experience all climatic conditions including drought and extremeair temperatures and radiation; the U.S. regional simulations indicate that the effect of calibration datalength on carbon dynamics is amplified at regional and temporal scales, leading to large discrepanciesamong different parameterization experiments, especially in July and August. Our findings areconditioned on the specific model we used and the calibration sites we selected. The optimal calibrationdata length may not be suitable for other models. However, this study demonstrates that there may exist athreshold for calibration data length and simply using more data would not guarantee a better modelparameterization and prediction. More importantly, climate variability might be an effective indicator ofinformation within the data, which could help data selection for model parameterization. As a result, we believe ourfindings will benefit the ecosystem modeling community in using multiple-year data to improve modelpredictability.

59 BASIC BIOLOGICAL SCIENCES↗

The 1994 international transatlantic two-way satellite time and frequency transfer experiment: Preliminary results

The international transatlantic time and frequency transfer experiment was designed by participating laboratories and has been implemented during 1994 to test the international communications path involving a large number of transmitting stations. This paper will present empirically determined clock and time scale differences, time and frequency domain instabilities, and a representative power spectral density analysis. The experiments by the method of co-location which will allow absolute calibration of the participating laboratories have been performed. Absolute time differences and accuracy levels of this experiment will be assessed in the near future.

Deyoung, James A.↗

Global Warming Estimation from MSU: Correction for Drift and Calibration Errors

Microwave Sounding Unit (MSU) radiometer observations in Ch 2 (53.74 GHz), made in the nadir direction from sequential, sun-synchronous, polar-orbiting NOAA morning satellites (NOAA 6, 10 and 12 that have about 7am/7pm orbital geometry) and afternoon satellites (NOAA 7, 9, 11 and 14 that have about 2am/2pm orbital geometry) are analyzed in this study to derive global temperature trend from 1980 to 1998. In order to remove the discontinuities between the data of the successive satellites and to get a continuous time series, first we have used shortest possible time record of each satellite. In this way we get a preliminary estimate of the global temperature trend of 0.21 K/decade. However, this estimate is affected by systematic time-dependent errors. One such error is the instrument calibration error. This error can be inferred whenever there are overlapping measurements made by two satellites over an extended period of time. From the available successive satellite data we have taken the longest possible time record of each satellite to form the time series during the period 1980 to 1998 to this error. We find we can decrease the global temperature trend by about 0.07 K/decade. In addition there are systematic time dependent errors present in the data that are introduced by the drift in the satellite orbital geometry arises from the diurnal cycle in temperature which is the drift related change in the calibration of the MSU. In order to analyze the nature of these drift related errors the multi-satellite Ch 2 data set is partitioned into am and pm subsets to create two independent time series. The error can be assessed in the am and pm data of Ch 2 on land and can be eliminated. Observations made in the MSU Ch 1 (50.3 GHz) support this approach. The error is obvious only in the difference between the pm and am observations of Ch 2 over the ocean. We have followed two different paths to assess the impact of the errors on the global temperature trend. In one path the entire error is placed in the am data while in the other it is placed in the pm data. Global temperature trend is increased or decreased by about 0.03 K/decade depending upon this placement. Taking into account all random errors and systematic errors our analysis of MSU observations leads us to conclude that a conservative estimate of the global warming is 0. 11 (+-) 0.04 K/decade during 1980 to 1998.

Prabhakara, C.↗

Making inertial confinement fusion models more predictive

Computer models of inertial confinement fusion (ICF) implosions play an essential role in experimental design and interpretation as well as our understanding of fundamental physics under the most extreme conditions that can be reached in the laboratory. Building truly predictive models is a significant challenge, with the potential to greatly accelerate progress to high yield and ignition. One path to more predictive models is to use experimental data to update the underlying physics in a way that can be extrapolated to new experiments and regimes. We describe a statistical framework for the calibration of ICF simulations using data collected at the National Ignition Facility (NIF). We perform Bayesian inferences for a series of laser shots using an approach that is designed to respect the physics simulation as much as possible and then build a second model that links the individual-shot inferences together. We show that this approach is able to match multiple X-ray and neutron diagnostics for a whole series of NIF “BigFoot” shots. Within the context of 2D radiation hydrodynamic simulations, our inference strongly favors a significant reduction in fuel compression over other known degradation mechanisms (namely, hohlraum issues and engineering perturbations). This analysis is expanded using a multifidelity technique to pick fuel-ablator mix from several candidate causes of the degraded fuel compression (including X-ray preheat and shock timing errors). Finally, we use our globally calibrated model to investigate the extra laser drive energy that would be required to overcome the inferred fuel compression issues in NIF BigFoot implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ADVANCED WAVEFORM SIMULATION FOR SEISMIC MONITORING EVENTS

Abstract We conduct a detailed test of a recently developed technique, CAPloc, in recovering source parameters from a few stations against results from a large broadband network in Southern California. The method uses a library of 1D Green’s functions which are broken into segments and matched to waveform observations with adjustable timing shifts. These shifts can be established by calibration against a distribution of well-located earthquakes and assembled in tomographic images for predicting various phase-delays. Synthetics generated from 2D cross-sections through these models indicates that 1D synthetic waveforms are sufficient in modeling but simply shifted in time for most hard-rock sites. This simplification allows the source inversion for both mechanism and location to easily obtain by grid search. We test one-station mechanisms for 160 events against the array for both PAS and GSC which have data since 1960. While individual solutions work well (about 90%), joint solutions produce more reliable and defensible results. Inverting for both mechanism and location also works well except for certain complex paths across deep basins and along mountain ridges.

58 GEOSCIENCES↗

Science Operations with the James Webb Space Telescope

The James Webb Space Telescope (JWST) will be a powerful space observatory whose four science instruments will deliver rich imaging and multiplexed spectroscopic datasets to the astronomical and planetary science communities. The ground segment for JWST, now being designed and built, will carry out JWST's science operations. The ground segment includes: (1) software that the scientific community will use to propose and specify new observations; (2) software that will schedule both science and calibration observations in a way that optimizes observing efficiency while managing the accumulation of momentum; (3) the infrastructure to regularly measure and maintain the telescope's wavefront; (4) orbit determination, ranging, and tracking; (5) communication via the Deep Space Network to command the observatory and retrieve scientific data; (6) onboard scripts that execute each observing program in an event-driven fashion, with occasional interruptions for targets of opportunity or time-critical observations; and (7) a system that processes and calibrates the data into science ready products, automatically recalibrates when calibrations improve, and archives the data for timely access by the principal investigator and later worldwide access by the scientific community. This ground system builds on experience from operating the Hubble Space Telescope, while solving challenges that are unique to the James Webb Space Telescope. In this paper, we describe the elements of the JWST ground system, how it will work operationally from the perspective of the observatory itself, and how a typical user will interact with the system to turn his/her idea into scientific discovery.

Rigby, Jane↗

Portable zero-delay assembly

Instrument is calibrated using back-to-back method. In comparison standard, S-X isolators are opposite from device being tested to permit signal flow in reverse direction. After calibration portable zero-delay assembly (PZDA) is used to set time delays of deep-space network ground-station ranging systems. Approach is also used to calibrate microwave links in other communications systems.

Franco, M. M.↗

A Demonstration of Precise Calibration of Tropospheric Delay Fluctuations with Water Vapor Radiometers

The ability of water vapor radiometers (WVRs) to calibrate changes in tropospheric delay was demonstrated during very long baseline radio interferometer (VLBI) observations at Goldstone, California. WVR measurements reduced the observed VLBI delay variations over a 13 hr period by a factor of approx. = 2.5. When applied to shorter time scales, a approx. = 50% reduction in 100-700 s delay variations was achieved during conditions of high tropospheric activity. Thermal WVR noise precluded calibration of short time scale delay fluctuations during quiet tropospheric conditions.

Teitelbaum, L. P.↗

Improving underwater localization accuracy with machine learning

Machine learning classification and regression algorithms were applied to calibrate the localization errors of a time-difference-of-arrival (TDOA)-based acoustic sensor array used for tracking salmon passage through a hydroelectric dam on the Snake River, Washington, USA. The locations of stationary and mobile acoustic tags were first tracked using the approximate maximum likelihood algorithm. Next, ensembles of classification trees successfully identified and filtered data points with large localization errors. This prefiltering step allowed the creation of a machine-learned regression model function, which decreased the median distance error by 50% for the stationary tracks and by 34% for the mobile tracks. It also extended the previous range of sub-meter localization accuracy from 100 m to 250 m horizontal distance from the dam face (the receivers). Median distance errors in the depth direction were especially decreased, falling from 0.49 m to 0.04 m in the stationary tracks and from 0.38 m to 0.07 m in the mobile tracks. These methods would have application to the calibration of error in any TDOA-based sensor network with a steady environment and array configuration.

47 OTHER INSTRUMENTATION↗