Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Measurement of low energy neutrino cross sections with the PEANUT experiment

The PEANUT experiment was designed to study neutrino interactions in the few GeV range using the NuMi beam at Fermilab. The detector uses a hybrid technique, being made of nuclear emulsions and scintillator trackers. Emulsion films act as a tracking device and they are interleaved with lead plates used as neutrino target. The detector is designed to reconstruct the topology of neutrino interactions at the single particle level. We present here the full reconstruction and analysis of a sample of 147 neutrino interactions occurred in the PEANUT detector and the measurement of the quasi-elastic, resonance and deep-inelastic contributions to the total charged current cross-section. This technique could be applied for the beam monitoring for future neutrino facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperNEMO status

The SuperNEMO experiment aims to reach a sensitivity up to 10{sup 26} years on the half-life of neutrinoless double beta decay. The SuperNEMO project strongly inherits from the previous Nemo3 experiment. It will consist of a ''tracko-calo'' modular detector with at least 100 kg of betabeta isotope. The current status of the main R and D tasks will be presented: enrichment and production of source foils, radiopurity control, tracker and calorimeter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e, a coherent μ → e conversion experiment at Fermilab

We describe a proposed experiment to search for Charged Lepton Flavor Violation (CLFV) using stopped muons at Fermilab. A primary Proton beam will strike a gold target, producing pions which decay to muons. Low-momentum negative muons will be collected, selected, and transported by a custom arrangement of solenoidal magnets and collimators. Muons will stop in thin foil targets, creating muonic atoms with significant nuclear overlap. Mu2e will search for the coherent conversion of nuclear bound muons to electrons, with an experimental signature of a single mono-energetic electron. Conversion electrons will be detected and measured in a low-mass straw tracker and a crystal calorimeter. Mu2e will have a sensitivity four orders of magnitude better than the most sensitive published result for μ → e conversion, and will have complementary physics reach to LHC experiments and μ → eγ decay experiments such as MEG.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging a nuclear reactor using cosmic ray muons

The passage of muons through matter is dominated by the Coulomb interaction with electrons and nuclei. The muon interaction with electrons leads to continuous energy loss and stopping of the muons. The muon interaction with nuclei leads to angular diffusion. We present experimental images of a nuclear reactor, the AGN-201M reactor at the University of New Mexico, using data measured with a particle tracker built from a set of sealed drift tubes. The data are compared with a geant4 model. In both the data and simulation, we identify specific regions corresponding to elements of the reactor structure, including its core, moderator, and shield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of muon radiography of the Toshiba nuclear critical assembly reactor

A 1.2 × 1.2 m{sup 2} muon tracker was moved from Los Alamos to the Toshiba facility at Kawasaki, Japan, where it was used to take ∼4 weeks of data radiographing the Toshiba Critical Assembly Reactor with cosmic ray muons. In this paper, we describe the analysis procedure, show results of this experiment, and compare the results to Monte Carlo predictions. The results validate the concept of using cosmic rays to image the damaged cores of the Fukushima Daiichi reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-peripheral heavy-ion collisions with CMS

Ultra-peripheral collisions (UPCs) of heavy ions involve long range electromagnetic interactions at impact parameters larger than twice the nuclear radius. At TeV energies, the strong electromagnetic field due to the coherent action of the Z = 82 proton charges generates a large flux of photons, which can be used for high-energy photoproduction studies. Heavy vector mesons produced in electromagnetic interactions provide direct information on the parton distribution functions in the nucleus at very low values of Bjorken-x. These events are characterized by a very low hadron multiplicity. The wide pseudo-rapidity coverage of the CMS detectors is used to separate such events from very peripheral nuclear interactions. The CMS experiment has excellent capabilities for the measurement of the heavy vector mesons in the dimuon decay channel using the tracker and the muon chambers. This analysis demonstrates CMS’s capabilities for measuring J/ψ and the two-photon process in ultra-peripheral collisions, using the 2011 PbPb and 2013 pPb data. The prospects for future measurements using the data to be collected in the 2015 PbPb run will be described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The T2K CCQE selection and prospects for CCQE, NCE cross-section measurements

A better understanding of the charge current quasi-elastic (CCQE) interaction channel will lead to a more precise ν{sub e} appearance and ν{sub μ} disappearance measurement at T2K. Measurements looking at the CCQE interaction using the near detector complex (ND280) help constrain cross-section uncertainties as well as the flux prediction at the far detector, Super-Kamiokande. The presented CCQE analysis is derived from a CC-inclusive selection using the tracking portion of ND280. The inclusive sample is broken into a CCQE-enhanced and CC non-QE like sample and each sample is used to constrain various parameters used for the far detector prediction. Future CCQE analyses using the tracker will either use the current selection or investigate newer selections for 2 track topologies. The neutral current equivalent to CCQE, neutral current elastic scattering (NCE), is being investigated using the pi-zero detector (POD). The NCE analysis selects a contained single track sample using muon/proton particle identification.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radon emanation based material measurement and selection for the SuperNEMO double beta experiment

The SuperNEMO Demonstrator experiment aims to study the neutrinoless double beta decay of 7 kg of {sup 82}Se in order to reach a limit on the light Majorana neutrino mass mechanism T{sub 1/2} (ββ0ν) > 6.5 10{sup 24} years (90%CL) equivalent to a mass sensitivity mβ{sub β} < 0.20 - 0.40 eV (90%CL) in two years of data taking. The detector construction started in 2014 and its installation in the Laboratoire Souterrain de Modane (LSM) is expected during the course of 2015. The remaining level of {sup 226}Ra ({sup 238}U chain) in the detector components can lead to the emanation of {sup 222}Rn gas. This isotope should be controlled and reduced down to the level of a 150 µBq/m{sup 3} in the tracker chamber of the detector to achieve the physics goals. Besides the HPGe selection of the detector materials for their radiopurity, the most critical materials have been tested and selected in a dedicated setup facility able to measure their {sup 222}Rn emanation level. The operating principle relies on a large emanation tank (0.7m{sup 3}) that allows measuring large material surfaces or large number of construction pieces. The emanation tank is coupled to an electrostatic detector equipped with a silicon diode to perform the alpha spectroscopy of the gas it contains and extract the {sup 222}Rn daughters. The transfer efficiency and the detector efficiency have been carefully calibrated through different methods. The intrinsic background of the system allows one to measure 222Rn activities down to 3 mBq, leading to a typical emanation sensitivity of 20 µBq/m{sup 2}/day for a 30 m{sup 2} surface sample. Several construction materials have been measured and selected, such as nylon and aluminized Mylar films, photomultipliers and tracking of the SuperNEMO Demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-low level radon assays in gases

The SuperNEMO experiment aims to search for the neutrinoless double beta decay (0νβ β) to T{sub 1{sub /{sub 2}}}(0ν) > 10{sup 26} years, this corresponds to an effective neutrino mass of 50-100 meV. The extremely rare event rate means the minimisation of background is of critical concern. The stringent strategy instigated to ensure detector radiopurity is outlined here for all construction materials. In particular the large R&D programme undertaken to reach the challengingly low level of radon, < 0.15 mBq/m{sup 3}, required inside the SuperNEMO gaseous tracker will be detailed. This includes an experiment designed to measure radon diffusion through various materials. A “Radon Concentration Line” (RnCL) was developed to be used in conjunction with a state-of-the-art radon detector in order to achieve world leading sensitivity to {sup 222}Rn content in large gas volumes at the level of a few µBq/m{sup 3}. A radon purification system was developed and installed which has demonstrated radon suppression by several orders of magnitude depending on the carrier gas. This apparatus has now been commissioned and measurements of cylindered gas have been made to confirm radon suppression by a factor 20 when using nitrogen as the carrier gas. The results from measurements of radon content in various gases, used inside SuperNEMO, using the RnCL will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combined heat and power generation with a HCPV system at 2000 suns

This work shows the development of an innovative solar CHP system for the combined production of heat and power based upon HCPV modules working at the high concentration level of 2000 suns. The solar radiation is concentrated on commercial InGaP/InGaAs/Ge triple-junction solar cells designed for intensive work. The primary optics is a rectangular off-axis parabolic mirror while a secondary optic at the focus of the parabolic mirror is glued in optical contact with the cell. Each module consist of 2 axis tracker (Alt-Alt type) with 20 multijunction cells each one integrated with an active heat sink. The cell is connected to an active heat transfer system that allows to keep the cell at a high level of electrical efficiency (ηel > 30 %), bringing the heat transfer fluid (water and glycol) up to an output temperature of 90°C. Accordingly with the experimental data collected from the first 1 kWe prototype, the total amount of extracted thermal energy is above the 50% of the harvested solar radiation. That, in addition the electrical efficiency of the system contributes to reach an overall CHP efficiency of more than the 80%.

14 SOLAR ENERGY↗

Image computing techniques to extrapolate data for dust tracking in case of an experimental accident simulation in a nuclear fusion plant

In this paper, a preliminary shadowgraph-based analysis of dust particles re-suspension due to loss of vacuum accident (LOVA) in ITER-like nuclear fusion reactors has been presented. Dust particles are produced through different mechanisms in nuclear fusion devices, one of the main issues is that dust particles are capable of being re-suspended in case of events such as LOVA. Shadowgraph is based on an expanded collimated beam of light emitted by a laser or a lamp that emits light transversely compared to the flow field direction. In the STARDUST facility, the dust moves in the flow, and it causes variations of refractive index that can be detected by using a CCD camera. The STARDUST fast camera setup allows to detect and to track dust particles moving in the vessel and then to obtain information about the velocity field of dust mobilized. In particular, the acquired images are processed such that per each frame the moving dust particles are detected by applying a background subtraction technique based on the mixture of Gaussian algorithm. The obtained foreground masks are eventually filtered with morphological operations. Finally, a multi-object tracking algorithm is used to track the detected particles along the experiment. For each particle, a Kalman filter-based tracker is applied; the particles dynamic is described by taking into account position, velocity, and acceleration as state variable. The results demonstrate that it is possible to obtain dust particles’ velocity field during LOVA by automatically processing the data obtained with the shadowgraph approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations and measurements of hot-electron generation driven by the multibeam two-plasmon-decay instability

We report that multiple-beam experiments relevant to direct-drive inertial confinement fusion show the importance of nonlinear saturation mechanisms in the common-wave two-plasmon-decay (TPD) instability. Planar target experiments on the OMEGA laser used hard-x-ray measurements to study the influence of the linear common-wave growth rate on TPD driven hot-electron production in two drive beam configurations and over a range of overlapped laser intensities from 3.6 to 15.2 x 10 14 W/cm 2 . The beam configuration with the larger linear common-wave growth rate had a lower intensity threshold for the onset of hot-electron production, but the linear growth rate did not have a significant impact on hot-electron production at high intensities. The experiments were modeled in 3-D using a hybrid code (LPSE) that combines a wave solver with a particle tracker to self-consistently calculate the electron velocity distribution and evolve electron Landau damping. Finally, good quantitative agreement was obtained between the simulated and measured hotel-electron distributions using a novel technique to account for macroscopic spatial and temporal variations that are present in the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microparticle cloud imaging and tracking for data-driven plasma science

Oceans of image and particle track data encountered in plasma interactions with microparticle clouds motivate development and applications of machine-learning (ML) algorithms. A local-constant-velocity tracker, a Kohonen neural network or self-organizing map, the feature tracking kit, and U-Net are described and compared with each other for microparticle cloud datasets generated from exploding wires, dusty plasmas, and atmospheric plasmas. Particle density and the signal-to-noise ratio have been identified as two important factors that affect the tracking accuracy. Fast Fourier transform is used to reveal how U-Net, a deep convolutional neural network developed for non-plasma applications, achieves the improvements for noisy scenes. Viscous effects are revealed in the ballistic motions of the particles from the exploding wires and atmospheric plasmas. Subdiffusion of microparticles satisfying Δr 2 ∝t k (k=0.84±0.02) is obtained from the dusty plasma datasets. Microparticle cloud imaging and tracking, when enhanced with data and ML models, present new possibilities for plasma physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shock initiation of the HMX-based explosive PBX 9012: Experiments, uncertainty analysis, and unreacted equation-of-state

In this study, shock initiation experiments have been carried out on the polymer-bonded explosive PBX 9012 [nominally 90% octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), 10% vinylidene–hexafluoropropylene copolymer (Viton A) by weight] in order to provide calibration data for the explosive’s unreacted equation-of-state (EOS) and shock-to-detonation transition for reactive burn rate calibration. The input pressures covered the range of 1.86–4.43 GPa. This provided run-to-detonation depths ranging from > 22.3 mm for the lowest pressure shot to 4.91 mm at the highest pressure. The relative shock sensitivity of PBX 9012 is compared to other HMX-explosives in terms of the Pop-plot, showing that the studied explosive is more sensitive than other similar HMX-based counterparts (with notable exceptions). The uncertainty in the shock velocity determinations from the shock tracker measurements are also investigated, yielding new uncertainty measures in the generated Hugoniot data and run-to-detonation coordinates. Finally, the unreacted equation-of-state is determined using a linear U s – u p Mie–Grüneisen relation and the Davis reactants EOS analytical form, the latter being more suited for reactive burn modeling.

36 MATERIALS SCIENCE↗

Experimental and modelling study of the effect of pre-shock duration on the double shock initiation response of PBX 9501

Here, a series of double shock initiation gas-gun experiments have been performed on PBX 9501 (95% weight HMX, 5% binder) in which the input conditions were nominally the same, but the time delay between the two shocks was explicitly varied. The impact conditions generated pre- and main shock pressures of 2.9 and 6.2 GPa respectively, with time delays between them ranging from 0.56 to 1.10 µs. This resulted in different levels of reaction behind the pre-shock prior to the main shock traversing the explosive samples, with the growth of reaction monitored using embedded particle velocity and shock tracker gauges. Simulated results from three reactive burn models (CREST, AWSD and SURF) are compared with the measured data to assess their ability to predict the response of PBX 9501 under such double shock conditions. The described experiments add to the body of evidence to help improve our understanding of the double shock initiation response of explosives, and the data obtained provide an excellent test for reactive burn models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OBSERVATION OF DIFFUSE COSMIC AND ATMOSPHERIC GAMMA RAYS AT BALLOON ALTITUDES WITH AN ELECTRON-TRACKING COMPTON CAMERA

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronautical Science/Japan Aerospace Exploration Agency on 2006 September 1, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 deg. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm{sup -2} we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be 10 times better than that of other experiments at around 1 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗