FAST RADIO BURSTS AND RADIO TRANSIENTS FROM BLACK HOLE BATTERIES

Most black holes (BHs) will absorb a neutron star (NS) companion fully intact without tidal disruption, suggesting the pair will remain dark to telescopes. Even without tidal disruption, electromagnetic (EM) luminosity is generated from the battery phase of the binary when the BH interacts with the NS magnetic field. Originally, the luminosity was expected to be in high-energy X-rays or gamma-rays, however, we conjecture that some of the battery power is emitted in the radio bandwidth. While the luminosity and timescale are suggestive of fast radio bursts (FRBs; millisecond-scale radio transients) NS–BH coalescence rates are too low to make these a primary FRB source. Instead, we propose that the transients form a FRB sub-population, distinguishable by a double peak with a precursor. The rapid ramp-up in luminosity manifests as a precursor to the burst which is 20%–80% as luminous given 0.5 ms timing resolution. The main burst arises from the peak luminosity before the merger. The post-merger burst follows from the NS magnetic field migration to the BH, causing a shock. NS–BH pairs are especially desirable for ground-based gravitational wave (GW) observatories since the pair might not otherwise be detected, with EM counterparts greatly augmenting the scientific leverage beyond the GW signal. The EM signal’s ability to break degeneracies in the parameters encoded in the GW and probe the NS magnetic field strength is quite valuable, yielding insights into open problems in NS magnetic field decay.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio transients and variables in the tenth Deeper, Wider, Faster observing run

The Deeper, Wider, Faster (DWF) program coordinates observations with telescopes across the electromagnetic spectrum, searching for transients on time-scales of milliseconds to days. The tenth DWF observing run was carried out in near real-time during September 2021, and consisted of six consecutive days of observations of the NGC 6744 galaxy group and a field containing the repeating fast radio burst FRB 190711 with the Australian Square Kilometre Array Pathfinder, the Dark Energy Camera, the Hard X-ray Modulation Telescope, and the Parkes 64-m ‘Murriyang’ radio telescope. Here, in this work, we present the results of an image-domain search for transient, variable, and circularly polarized sources carried out with ASKAP, using data from the observing run along with test observations prior to the run and follow-up observations carried out during and after the run. We identified eight variable radio sources, consisting of one pulsar, six stellar systems (five of which exhibit circularly polarized emission), and one previously uncatalogued source. Of particular interest is the detection of pulses from the ultra-cool dwarf SCR J1845–6357 with a period of 14.2 ± 0.3 h in good agreement with the known optical rotation period, making this the slowest rotating radio-loud ultra-cool dwarf discovered.

79 ASTRONOMY AND ASTROPHYSICS↗

Swift /UVOT discovery of Swift J221951−484240: a UV luminous ambiguous nuclear transient

We report the discovery of Swift J221951−484240 (hereafter: J221951), a luminous slow-evolving blue transient that was detected by the Neil Gehrels Swift Observatory Ultraviolet/Optical Telescope (Swift/UVOT) during the follow-up of gravitational wave alert S190930t, to which it is unrelated. Swift/UVOT photometry shows the UV spectral energy distribution of the transient to be well modelled by a slowly shrinking blackbody with an approximately constant temperature of T ∼ 2.5 × 10 4 K. At a redshift z = 0.5205, J221951 had a peak absolute magnitude of M u,AB = −23 mag, peak bolometric luminosity Lmax = 1.1 x 10 45 ergs -1 and a total radiated energy of E > 2.6 × 10 52 erg. The archival Wide-field Infrared Survey Explorer IR photometry shows a slow rise prior to a peak near the discovery date. Spectroscopic UV observations display broad absorption lines in N V and O VI, pointing towards an outflow at coronal temperatures. The lack of emission in the higher H α lines, N I and other neutral lines is consistent with a viewing angle close to the plane of the accretion or debris disc. The origin of J221951 cannot be determined with certainty but has properties consistent with a tidal disruption event and the turn-on of an active galactic nucleus.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct extraction of intense-field-induced polarization in the continuum on the attosecond time scale from transient absorption

Here, a procedure is suggested for using transient absorption spectroscopy above the ionization threshold to measure the polarization of the continuum induced by an intense optical pulse. In this way transient absorption measurement can be used to probe subfemtosecond intense field dynamics in atoms and molecules. The method is based on an approximation to the dependence of these spectra on time delay between an attosecond XUV probe pulse and an intense pump pulse that is tested over a wide range of intensities and time delays by all-electrons-active calculations using the multiconfiguration time-dependent Hartree-Fock method in the case of neon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization-resolved core exciton dynamics in LiF using attosecond transient absorption spectroscopy

The ability to control absorption by modifying the polarization of light presents an exciting opportunity to experimentally determine the orbital alignment of absorption features. Here, attosecond extreme ultraviolet (XUV) transient absorption spectroscopy is used to investigate the polarization dependence of core exciton dynamics in LiF thin films at the Li + K edge. XUV pulses excite electrons from the Li 1s core level into the conduction band, allowing for the formation of a p-orbital-like core exciton, aligned along the XUV light polarization axis. A sub-5 fs near-infrared (NIR) probe pulse then arrives at variable time delays, perturbing the XUV-excited states and allowing the coherence decay of the core exciton to be mapped. The coherence lifetimes are found to be ≈ 2.4 ± 0.4 fs, which is attributed to a phonon-mediated dephasing mechanism as in previous core exciton studies. The differential absorption features are also shown to be sensitive to the relative polarization of the XUV and NIR fields. The parallel NIR probe induces couplings between the initial XUV-excited p-like bright exciton and s-like dark excitons. When crossed pump and probe polarizations are used, the coupling between the bright and dark states is no longer dipole-allowed, and the transient absorption signal associated with the coupling is suppressed by approximately 90%. This interpretation is supported by simulations of a few-level model system, as well as analysis of the calculated band structure. Here, the results indicate that laser polarization can serve as a powerful experimental tool for exploring the orbital alignment of core excitonic states in solid-state materials.

Attosecond laser spectroscopy↗

Joint tests at INL and CEA of a transient hot wire needle probe for in-pile thermal conductivity measurement

Thermal conductivity is a key property that must be known for proper design, testing, and deployment of new fuels and structural materials in nuclear reactors. Thermal conductivity is highly dependent on the physical structure, chemical composition, and the state of the material. Typically, thermal conductivity changes that occur during irradiation are currently measured out-of-pile using a 'cook and look' approach. But repeatedly removing samples from a test reactor to make measurements is expensive, has the potential to disturb phenomena of interest, and only provides understanding of the sample's end state when each measurement is made. There are also limited thermo-physical property data available for advanced fuels; and such data are needed for simulation codes, the development of next generation reactors, and advanced fuels for existing nuclear plants. Being able to quickly characterize fuel thermal conductivity during irradiation can improve the fidelity of data, reduce costs of post-irradiation examinations, increase understanding of how fuels behave under irradiation, and confirm or improve existing thermal conductivity measurement techniques. This paper discusses efforts to develop and evaluate an innovative in-pile thermal conductivity sensor based on the transient hot wire thermal conductivity method (THWM), using a single needle probe (NP) containing a line heat source and thermocouple embedded in the fuel. The sensor that has been designed and manufactured by the Idaho National Laboratory (INL) includes a unique combination of materials, geometry, and fabrication techniques that make the hot wire method suitable for in-pile applications. In particular, efforts were made to minimize the influence of the sensor and maximize fuel hot-wire heating. The probe has a thermocouple-like construction with high temperature resistant materials that remain ductile while resisting transmutation and materials interactions. THWM-NP prototypes were fabricated for both room temperature proof-of-concept evaluations and high temperature testing. Evaluations have been performed jointly by the INL and the French Alternative Energies and Atomic Energy Commission (CEA), both in Idaho Falls (USA) and in Cadarache (France), in the framework of a collaborative program for instrumentation of Material Testing Reactors. Initial tests were conducted on samples with a large range of thermal conductivities and temperatures ranging from 20 deg. C to 600 deg. C. Particularly, tests were recently performed on a sample having thermal conductivity and dimensions similar to UO{sub 2} and MOX nuclear fuels, in order to validate the ability of this sensor to operate for in-pile characterization of Light Water Reactors fuels. The results of the tests already completed at INL and CEA indicate that the Transient Hot Wire Needle Probe offers an enhanced method for in-pile detection of thermal conductivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Modeling of Grid-Forming Inverters for Transient Stability Simulations of an all Inverter-based Distribution System

Existing models of grid-forming inverters are typically three-phase electromagnetic models and positive sequence electromechanical models. Both of them are not suitable for dynamic simulations of large scale three-phase unbalanced distribution systems. In order to investigate grid-forming inverters’ impact on the transient stability of large scale three-phase unbalanced distribution systems, a dynamic model of a grid-forming inverter is developed and implemented in an open-source GridLAB-D simulation environment. The advantage of this method is that it can be extended to full-size three-phase unbalanced distribution systems. Simulation results of an all grid-forming inverter-based modified version of IEEE 123-node distribution system verify the capability of grid-forming inverters to maintain the transient stability of a resilient distribution system.

Grid-forming, Inverter, Distribution System, Trans↗

Explainable Bayesian Neural Network for Probabilistic Transient Stability Analysis Considering Wind Energy

While several data-driven models have been developed for transient stability assessment, how to consider the uncertainties from load and renewable generations and provide interpretation of data-driven assessment results are still open. This paper proposes an explainable Bayesian Neural Network (BNN) for probabilistic transient stability assessment (TSA). By extracting the uncertainties from loads and wind farms, the BNN model can make a reliable prediction and quantify the prediction uncertainties. We also develop the Gradient Shap algorithm to make the global and local explanations for the probabilistic TSA model, a significant advantage over existing black-box data-driven methods. Numerical results on the modified IEEE 39-bus system show that the proposed method outperforms the existing methods in terms of prediction accuracy and uncertainty quantification capabilities. The explainability of the proposed method allows system operators to design preventive controls for enhancing system stability.

Bayesian Neural Network↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Simulation of Fast-Rise Transients in a Large-Power Transformer Winding

A high-altitude electromagnetic pulse (HEMP) may pose a significant threat to the electrical power grid. In this context, the present study considers here the potential impact of the HEMP early-time component (E1) on the winding of a typical transmission power line transformer. A time-domain, fully electromagnetic, three-dimensional, finite-element model was used to simulate the propagation of an E1-induced voltage surge into the transformer winding. The analysis is focused on the first few turns of the winding, the ones that are impacted by the largest electric field resulting from the applied pulse. The model follows the transient dynamics, while the pulse is traveling along the conductor, and the electric field is established across the insulation gaps through capacitive coupling. The simulations also considered the effect of an electrically floating, “shield” winding conductor. This is used as a countermeasure to improve the voltage uniformity across the winding during fast-rise transients. In this case, the propagation of the E1-induced pulse is compared with that from a slower rising, lightning standard waveform. The simulation results show that the presence of the shield conductor can effectively reduce the peak electric field between winding turns, in the presence of either E1 or lightning waveforms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part II: Long Term Faults

Here, this paper addresses the transient stability (also called large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability, and frequency response for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted system' components present and is applicable to the study of both short term and long term faults. Part I of this research discussed the short term faults whereas as Part II, the present paper, discusses long term faults. This research considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000 MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

The Effect of the Gate-Connected Field Plate on Single-Event Transients in AlGaN/GaN Schottky-Gate HEMTs

A focused pulsed X-ray beam is used to determine how the redistribution of the electric field by the gate-connected field plate affects single-event transient (SET) susceptibility of an AlGaN/GaN Schottky-gate HEMT on SiC. SETs generated by scanning the X-ray beam across the HEMT depend strongly on the presence of the field plate, radiation strike location, bias conditions, and X-ray photon energy. Furthermore, for the particular HEMT we tested, the gate-connected field plate reduces the electric-field strength near the edge of the gate by a factor of approximately 2, which results in faster decaying transients and less collected charge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis and Experimental Evaluation of Middle-Point Inductance's Effect on Switching Transients for Multiple-Chip Power Module Package

Middle-point inductance L middle can be introduced in multiple-chip power module package designs. In this paper, the effect of middle-point inductance on switching transients is analyzed first using a frequency-domain analysis. Then a dedicated multiple-chip power module is fabricated with the capability of varying L middle , and extensive switching tests are conducted to evaluate the middle-point inductance's impact. Experiment result shows that the active MOSFET's turn-on loss decreases at higher values of L middle , while its turn-off loss increases. Detailed analysis of this loss variation is presented. In addition to the switching loss variation, it is also observed that different peak voltage stresses are imposed on the active switch and antiparallel diode during the switching transients. Specifically, in the case of lower MOSFET's turn-off, the maximum voltage of the lower MOSFET increases as L middle goes up; however, the peak voltage of the antiparallel diode decreases significantly. Furthermore, the induced voltage spikes during upper MOSFET turn-on process is also evaluated, and an opposite trend is observed experimentally. Analysis of the voltage overshoot variation is discussed. Based on the experimental evaluation and analysis, a multiple-chip power module package design guideline is summarized considering the middle-point inductance's effect.

42 ENGINEERING↗

Distributed Control of Inverter-Interfaced Microgrids Based on Consensus Algorithm with Improved Transient Performance

Conventional control solutions of the inverter-interfaced microgrids are usually designed based on models with fully decoupled subsystems. The negligence of the strong coupling due to power lines impedance leads to large transient line currents, which might trigger false protection. Besides, the droop-based control methods unnecessarily introduce system frequency and voltage deviations. To overcome these issues, a novel distributed control scheme is proposed for the inverter-interfaced microgrids in this study. The objective of the primary control is to regulate the bus voltages and frequency while suppressing the transient line currents. The objective of secondary control is to maintain fair load sharing. Both primary control and secondary control are distributed and subsystems or control agents only require measurements from local and neighboring subsystems. The detailed control problem formulation, control design and stability analysis are presented in the paper. Finally, the effectiveness of the proposed control solution is evaluated through extensive simulations based on both simplified and detailed models.

24 POWER TRANSMISSION AND DISTRIBUTION↗