Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Global Gyrokinetic Simulations of Isotope Effects under Ambipolar Electric Fields and Advances Toward Whole-Volume Modeling

We review global gyrokinetic simulation studies on plasma transport in the Large Helical Device using XGC-S. XGC-S is an extended version of X-point Gyrokinetic Code for stellarators and has been progressively verified throughout the code development process. Verification tests of neoclassical transport successfully demonstrate the generation of an ambipolar electric field due to ripple-trapped particles. We perform quasi-linear analyses of the ion temperature gradient mode under the influence of the ambipolar electric field. The results reveal that the ambipolar electric field and the heavy hydrogen component in mixed isotope plasmas can lead to the favorable isotope effect observed in recent deuterium experiments. We also present recent efforts in code development toward whole-volume simulations, including the helical divertor region. A mesh generation scheme based on field-line tracing and the construction of curved surfaces perpendicular to the magnetic field would be promising for global field calculations in the whole-volume simulations.

Basic Plasma Phenomena and Gas Discharges↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Material Model Parameters Optimization in Liquid Mercury Target Dynamics Simulation With Machine Learning Surrogates

A pulsed spallation target is subjected to very short (∼0.7μs) but intense loads (23.3 kJ) from repeated proton pulses, which knock away neutrons from the mercury atoms’ nuclei for a wide range application in physics, engineering, medicine, petroleum exploration, biology, chemistry, etc. The effect of this pulsed loading on the stainless-steel target module which contains the flowing mercury target material is difficult to predict not only due to its short but intense explosive-like physical reaction, but also the nonlinear material behavior of the liquid mercury in the structure. Injecting small helium bubbles in the mercury has been an efficient method of mitigating the pressure wave at high power level stage. However, prediction of the resultant loading on the target is more difficult when helium gas is intentionally injected into the mercury. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this complex multi-physics dynamics problem by including the bubble dynamics in the liquid mercury. A parameter sensitivity study was firstly employed to understand their impact on the simulation strains. The investigated parameters included E, μ, γ, σ, n, VFgas, and gas cumulative volume curve control parameters a and b. Verification and validation results from sparse polynomial expansions (SPE) method and directional Gaussian smoothing (DGS) optimization show that the surrogate model had training error of ∼7% and validation error of ∼15%, indicating that machine learning methods and surrogate models can help optimize the uncertain parameters in the complex 2-phase material model. This approach is expected to fill the knowledge gap between unknown liquid-gas mixture material model and measured vessel strain responses.

Lin, Lianshan↗

SU-E-T-406: Use of TrueBeam Developer Mode and API to Increase the Efficiency and Accuracy of Commissioning Measurements for the Varian EDGE Stereotactic Linac

Purpose: The Varian EDGE machine is a new stereotactic platform, combining Calypso and VisionRT localization systems with a stereotactic linac. The system includes TrueBeam DeveloperMode, making possible the use of XML-scripting for automation of linac-related tasks. This study details the use of DeveloperMode to automate commissioning tasks for Varian EDGE, thereby improving efficiency and measurement consistency. Methods: XML-scripting was used for various commissioning tasks,including couch model verification,beam-scanning,and isocenter verification. For couch measurements, point measurements were acquired for several field sizes (2×2,4×4,10×10cm{sup 2}) at 42 gantry angles for two couch-models. Measurements were acquired with variations in couch position(rails in/out,couch shifted in each of motion axes) compared to treatment planning system(TPS)-calculated values,which were logged automatically through advanced planning interface(API) scripting functionality. For beam scanning, XML-scripts were used to create custom MLC-apertures. For isocenter verification, XML-scripts were used to automate various Winston-Lutz-type tests. Results: For couch measurements, the time required for each set of angles was approximately 9 minutes. Without scripting, each set required approximately 12 minutes. Automated measurements required only one physicist, while manual measurements required at least two physicists to handle linac positions/beams and data recording. MLC apertures were generated outside of the TPS,and with the .xml file format, double-checking without use of TPS/operator console was possible. Similar time efficiency gains were found for isocenter verification measurements Conclusion: The use of XML scripting in TrueBeam DeveloperMode allows for efficient and accurate data acquisition during commissioning. The efficiency improvement is most pronounced for iterative measurements, exemplified by the time savings for couch modeling measurements(approximately 10 hours). The scripting also allowed for creation of the files in advance without requiring access to TPS. The API scripting functionality enabled efficient creation/mining of TPS data. Finally, automation reduces the potential for human error in entering linac values at the machine console,and the script provides a log of measurements acquired for each session. This research was supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffraction properties of cylindrically bent KAP crystals in energy range of 2.3–7.5 keV using synchrotron radiation

Verification of physics models and computer simulations are heavily reliant upon the accuracy of experimental measurements. Calibration of instrument responses becomes an important step to achieve this goal. This paper presents systematic studies of bent potassium acid phthalate (KAP) crystals using Lawrence Berkeley National Laboratories, Advanced Light Source, beamline 9.3.1 in the energy range of 2.3 to 7.5 keV. A set of KAP crystals, gradually bent from flat up to a 50.8 mm cylindrical curvature. The measured integrated reflectivity for this set of KAP crystals shows good agreement with the X-ray Oriented Program (XOP) calculations when adjusting the Debye–Waller temperature factor and using the multilamellar model in the calculations. Significant differences in rocking curve profiles were observed between experimental measurements and theory. A forward convolution model and software code were developed to include experimental parameters, allowing the investigation of the difference between measurements and calculations. After considering the experimental parameters, good agreements were obtained for the rocking curve profiles for all bending radii with a unique set of parameters. Our results show that XOP can be a useful and reliable tool to predict performance of cylindrically bent KAP crystals in this energy range.

Wu, Ming↗

Numerical modeling of an all vanadium redox flow battery.

We develop a capability to simulate reduction-oxidation (redox) flow batteries in the Sierra Multi-Mechanics code base. Specifically, we focus on all-vanadium redox flow batteries; however, the capability is general in implementation and could be adopted to other chemistries. The electrochemical and porous flow models follow those developed in the recent publication by [28]. We review the model implemented in this work and its assumptions, and we show several verification cases including a binary electrolyte, and a battery half-cell. Then, we compare our model implementation with the experimental results shown in [28], with good agreement seen. Next, a sensitivity study is conducted for the major model parameters, which is beneficial in targeting specific features of the redox flow cell for improvement. Lastly, we simulate a three-dimensional version of the flow cell to determine the impact of plenum channels on the performance of the cell. Such channels are frequently seen in experimental designs where the current collector plates are borrowed from fuel cell designs. These designs use a serpentine channel etched into a solid collector plate.

Clausen, Jonathan R.↗

Critical and Subcritical 0-Power Experiment at Rensselaer (CaSPER)

This report discusses the 0-power experiment at Rensselaer Polytechnic Institute (CaSPER). K eff simulation results, list-mode multiplication results, and related work are included. The aim of the work is subcritical measurements for code and nuclear data validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using the BEopt Automated Residential Simulation Test Suite to Enable Comparative Analysis Between Energy Simulation Engines: Preprint

Verification and validation are crucial software quality control procedures when developing and implementing models. This is particularly important as a variety of stakeholders rely on accurate predictions from building simulation programs. This study uses the BEopt Automated Residential Simulation Test Suite (BARTS) to facilitate comparison of two energy simulation engines across various building components and includes models that isolate the impacts of specific building components on annual energy consumption. As a case study, BARTS has been used to identify important discrepancies between the engines for several components of the building models; these discrepancies are caused by differences in the models used by the engines or coding errors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sci-Thur PM – Colourful Interactions: Highlights 01: Design to delivery of spatially fractionated mini-beam canine radiotherapy

Spatial fractionation of radiation using arrays of narrow parallel micro-planar beams (less than 1 mm), is a relatively new concept with many unknowns specifically within the underlying biology of cell death. A tungsten collimator has been designed to produce mini-beams with a Varian linear accelerator for translational animal research into the effectiveness of spatial fractionation mini-beam radiotherapy (MBRT). This work presents the treatment planning process and workflow for the application of MBRT treatments within a clinical study. For patient dose calculations, the MBRT collimator was incorporated into a Monte Carlo based treatment planning system called MMCTP. Treatment planning was split between Eclipse and MMCTP, as the field apertures were determined within Eclipse prior to being sent to MMCTP for dose calculations. The calculated plan was transferred back into Aria with updated MUs per field for patient treatment. Patients were positioned within a vac-lock bag lying prone with a bite block and a thermoplastic mask to immobilize the head. Prior to treatment, a delivery verification plan was created within MMCTP. DQA output measurements of the treatment fields agreed with the calculated dose to within 1.5%. We have presented a workflow for MBRT treatments that include the planning technique, dose calculation method, DQA process and data integration into a record and verify system. The clinical study following this workflow represent the first series of linac based MBRT patients and depending on the clinical outcome of the study, our technique could be applied to human MBRT treatments.

60 APPLIED LIFE SCIENCES↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

SU-E-T-349: Verification of a Monte Carlo Simulation Tool as a Second Check for TomoTherapy Treatment Planning

Purpose: To verify a virtual source model used in Monte Carlo (MC) TomoTherapy simulations and to provide a tool for the dose distribution second check for TomoTherapy treatment planning. Methods: Published studies adopted the full MC model to simulate helical TomoTherapy which use phase space files (PSFs) at different scoring planes to facilitate patient dose calculations. We have developed a simple virtual source model (VSM) based on the commissioning data of helical TomoTherapy unit which can be exported from the treatment planning station (TPS). To calculate the patient dose distribution, TPS-generated sinograms are extracted from archived patient XML files and fluence maps are created by incorporating the openclose leaf time with leaf filter, jaw penumbra, and leaf latency. The VSM has been validated for various geometrical set-ups including open fields, heterogeneous media and clinical DQA cases. Results: Good agreement was obtained between our VSM and a published full MC model for the test case of heterogeneous media. For the complex clinical head and neck (HN) case, the MC simulation of the DQA plan agreed with the film measurement with 98% of planar dose pixels passing the 2%/2 mm gamma value test. For the patient treatment plan itself, the MC simulation showed comparable DVHs for the planning target volumes (PTVs) and organs-at-risk (OARs). Deviations observed were consistent with literature. Conclusion: The proposed VSM can be used in the MC method to accurately simulate the patient dose distributions for helical TomoTherapy.

60 APPLIED LIFE SCIENCES↗

Building America Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York (Fact Sheet)

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient by itself. In addition, the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of CARB's multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in 3 multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions

Purpose: Gantry-mounted megavoltage electronic portal imaging devices (EPIDs) have become ubiquitous on linear accelerators. WatchDog is a novel application of EPIDs, in which the image frames acquired during treatment are used to monitor treatment delivery in real time. We report on the preliminary use of WatchDog in a prospective study of cancer patients undergoing intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) and identify the challenges of clinical adoption. Methods and Materials: At the time of submission, 28 cancer patients (head and neck, pelvis, and prostate) undergoing fractionated external beam radiation therapy (24 IMRT, 4 VMAT) had ≥1 treatment fraction verified in real time (131 fractions or 881 fields). EPID images acquired continuously during treatment were synchronized and compared with model-generated transit EPID images within a frame time (∼0.1 s). A χ comparison was performed to cumulative frames to gauge the overall delivery quality, and the resulting pass rates were reported graphically during treatment delivery. Every frame acquired (500-1500 per fraction) was saved for postprocessing and analysis. Results: The system reported the mean ± standard deviation in real time χ 91.1% ± 11.5% (83.6% ± 13.2%) for cumulative frame χ analysis with 4%, 4 mm (3%, 3 mm) criteria, global over the integrated image. Conclusions: A real-time EPID-based radiation delivery verification system for IMRT and VMAT has been demonstrated that aims to prevent major mistreatments in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SHARP User Manual

SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification of a Multiphysics Code with Method of Manufactured Solutions

To push the modeling and simulation to a new level in simulating realistic problems, a common practice is to couple different single-physics codes together to simulate problems involving multiple physics. Although the method of manufactured solutions (MMS) has been shown to be a powerful tool in code verification, there has been little work on applying MMS to a multi-physics code system. Additionally, due to the scarcity of multi-physics validation data, the significance of code verification becomes more prominent as an important part in software quality assurance. With this, the application of MMS to a coupled code system, e.g. VERA-CS, has become a crucial step, which helps identify bugs affecting the order of accuracy, thus increasing the credibility and reliability of the code. In this work, we investigate the application of MMS to verify a multi-physics code system and establish a framework for this application, and we demonstrate this with a neutronics code coupled with a thermal hydraulics (TH) code. The convection module is not yet added to this work, so by TH, only conduction is considered.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

Analysis of Phenix end-of-life natural convection test with the MARS-LMR code

The end-of-life test of Phenix reactor performed by the CEA provided an opportunity to have reliable and valuable test data for the validation and verification of a SFR system analysis code. KAERI joined this international program for the analysis of Phenix end-of-life natural circulation test coordinated by the IAEA from 2008. The main objectives of this study were to evaluate the capability of existing SFR system analysis code MARS-LMR and to identify any limitation of the code. The analysis was performed in three stages: pre-test analysis, blind posttest analysis, and final post-test analysis. In the pre-test analysis, the design conditions provided by the CEA were used to obtain a prediction of the test. The blind post-test analysis was based on the test conditions measured during the tests but the test results were not provided from the CEA. The final post-test analysis was performed to predict the test results as accurate as possible by improving the previous modeling of the test. Based on the pre-test analysis and blind test analysis, the modeling for heat structures in the hot pool and cold pool, steel structures in the core, heat loss from roof and vessel, and the flow path at core outlet were reinforced in the final analysis. The results of the final post-test analysis could be characterized into three different phases. In the early phase, the MARS-LMR simulated the heat-up process correctly due to the enhanced heat structure modeling. In the mid phase before the opening of SG casing, the code reproduced the decrease of core outlet temperature successfully. Finally, in the later phase the increase of heat removal by the opening of the SG opening was well predicted with the MARS-LMR code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-J-129: Verification of Geometric and Dosimetric Accuracy of Respiratory Management Systems Using Homemade Phantom

Purpose: Different placements of Infrared Cameras (IRC) in CT and treatment rooms can cause gating window level (GWL) variations leading to differences between GWL used for planning and treatments. Although, Varian Clinac DHX-OBI sytem and CT are equipped with the same kind of IRC, Truebeam STx (TB) has a different type of IRC known as banana type. In this study; geometric and dosimetric accuracy of respiratory management system (RPM) for different machines were investigated with a special homemade phantom. Methods: Special phantom was placed on the respiratory simulator machine and a CT data set was obtained at the end of the expirium phase (EOE). Conformal and IMRT plans were generated on the EOE CT image series for both DHX-OBI and TB LINACs while a VMAT plan was generated only for TB.The acquired respiratory graphs in the CT were directly sent to DHX-OBI system, and they were converted with software before sending to TB. EBT3 films were placed inside the phantom and were irradiated using RPM system with two machines for different plans. Planar dose distributions were compared with gamma analysis (GA) method (3mm, %3) to evaluate planned-measured dose differences. In addition, radio-opac marker was placed in the center of the phantom to evaluate the geometric accuracy of treatment field with gated flouroscopy (GF). Results: There were no shifts detected between planning and treeatment GWL for both DHX-OBI and TB. Difference on the GF image between digital graticule and radio-opac marker was <1mm for TB and 1mm for DHX-OBI. Although, GA agreement was 97% for conformal and IMRT techniques in TB, it was 96% for VMAT technique. While GA agreement was 98% for conformal technique in DHX-OBI, IMRT was 95%.ConclusionThis study showed that RPM can be used accurately in spite of different IRC placements or different types of ICR used.

60 APPLIED LIFE SCIENCES↗