At least 1,009 records · Page 56

Shock-induced termination of reentrant cardiac arrhythmias: Comparing monophasic and biphasic shock protocols

In this article, we compare quantitatively the efficiency of three different protocols commonly used in commercial defibrillators. These are based on monophasic and both symmetric and asymmetric biphasic shocks. A numerical one–dimensional model of cardiac tissue using the bidomain formulation is used in order to test the different protocols. In particular, we performed a total of 4.8 × 10{sup 6} simulations by varying shock waveform, shock energy, initial conditions, and heterogeneity in internal electrical conductivity. Whenever the shock successfully removed the reentrant dynamics in the tissue, we classified the mechanism. The analysis of the numerical data shows that biphasic shocks are significantly more efficient (by about 25%) than the corresponding monophasic ones. We determine that the increase in efficiency of the biphasic shocks can be explained by the higher proportion of newly excited tissue through the mechanism of direct activation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gravitational waves from a black hole orbiting in a wormhole geometry

Current ground-based gravitational wave detectors are tuned to observe compact object mergers from stellar mass black holes and neutron stars; ~50 such events have been published to date. More exotic compact objects may exist, collisions of which would also generate copious gravitational waves. In this work, we model a stellar mass black hole inspiral into a stable, nonspinning, traversable wormhole, and find a characteristic waveform—an antichirp and/or burst—as the black hole outspirals into our region of the Universe. This is a characteristic signature which can be useful in wormhole searches in gravitational wave data or used to constrain wormhole geometries.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-91: Development of Real Time Abdominal Compression Force (ACF) Monitoring System

Purpose: Hard-plate based abdominal compression is known to be effective, but no explicit method exists to quantify abdominal compression force (ACF) and maintain the proper ACF through the whole procedure. In addition, even with compression, it is necessary to do 4D CT to manage residual motion but, 4D CT is often not possible due to reduced surrogating sensitivity. In this study, we developed and evaluated a system that both monitors ACF in real time and provides surrogating signal even under compression. The system can also provide visual-biofeedback. Methods: The system developed consists of a compression plate, an ACF monitoring unit and a visual-biofeedback device. The ACF monitoring unit contains a thin air balloon in the size of compression plate and a gas pressure sensor. The unit is attached to the bottom of the plate thus, placed between the plate and the patient when compression is applied, and detects compression pressure. For reliability test, 3 volunteers were directed to take several different breathing patterns and the ACF variation was compared with the respiratory flow and external respiratory signal to assure that the system provides corresponding behavior. In addition, guiding waveform were generated based on free breathing, and then applied for evaluating the effectiveness of visual-biofeedback. Results: We could monitor ACF variation in real time and confirmed that the data was correlated with both respiratory flow data and external respiratory signal. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed real time ACF monitoring system was found to be functional as intended and consistent. With the capability of both providing real time surrogating signal under compression and enabling visual-biofeedback, it is considered that the system would improve the quality of respiratory motion management in radiation therapy. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully Autonomous Multiplet Event Detection: Application to Local-Distance Monitoring of Blood Falls Seismicity

We apply a fully autonomous icequake detection methodology to a single day of high-sample rate (200 Hz) seismic network data recorded from the terminus of Taylor Glacier, ANT that temporally coincided with a brine release episode near Blood Falls (May 13, 2014). We demonstrate a statistically validated procedure to assemble waveforms triggered by icequakes into populations of clusters linked by intra-event waveform similarity. Our processing methodology implements a noise-adaptive power detector coupled with a complete-linkage clustering algorithm and noise-adaptive correlation detector. This detector-chain reveals a population of 20 multiplet sequences that includes ~150 icequakes and produces zero false alarms on the concurrent, diurnally variable noise. Our results are very promising for identifying changes in background seismicity associated with the presence or absence of brine release episodes. We thereby suggest that our methodology could be applied to longer time periods to establish a brine-release monitoring program for Blood Falls that is based on icequake detections.

42 ENGINEERING↗

Satellite altimetry

The present status of the instrumentation and applications of satellite altimetry are reviewed. The earth-orbiting altimeters launched thus far are all basically conventional monostatic tracking radars which make three fundamental measurements: (1) time of arrival (altitude), (2) shape (waveform sample gates), and (3) amplitude (automatic gain control). A comparison of the fundamental characteristics of the present altimeter systems is given, along with evaluation of the preliminary results of altimeter data collected by Seasat-1. The application results described are mainly from the analysis of approximately 1/3 of the 2000 hours of altimeter data obtained from GEOS-3 through October 1978.

Stanley, H. R.↗

Unsteady blade pressure measurements for the SR-7A propeller at cruise conditions

The unsteady blade surface pressures were measured on the SR-7A propeller. The freestream Mach no., inflow angle, and advance ratio were varied while measurements were made at nine blade stations. At a freestream Mach no. of 0.8, the data in terms of unsteady pressure coefficient vs. azimuth angle are compared to an unsteady 3-D Euler solution, yielding very encouraging results. The code predicts the shape (phase) of the waveform very well, while the magnitude is over-predicted in many cases. At tunnel Mach nos. below 0.6, an unusually large response on the suction surface at 0.15 chord and 0.88 radius was observed. The behavior of this response suggests the presence of a leading edge vortex. The midchord measuring stations on the suction surface exhibit a response that leads the forcing function while most other locations show a phase lag.

Heidelberg, L. J.↗

Geometric adjustments to account for eye eccentricity in processing horizontal and vertical eye and head movement data

Neglecting the eccentric position of the eyes in the head can lead to erroneous interpretation of ocular motor data, particularly for near targets. We discuss the geometric effects that eye eccentricity has on the processing of target-directed eye and head movement data, and we highlight two approaches to processing and interpreting such data. The first approach involves determining the true position of the target with respect to the location of the eyes in space for evaluating the efficacy of gaze, and it allows calculation of retinal error directly from measured eye, head, and target data. The second approach effectively eliminates eye eccentricity effects by adjusting measured eye movement data to yield equivalent responses relative to a specified reference location (such as the center of head rotation). This latter technique can be used to standardize measured eye movement signals, enabling waveforms collected under different experimental conditions to be directly compared, both with the measured target signals and with each other. Mathematical relationships describing these approaches are presented for horizontal and vertical rotations, for both tangential and circumferential display screens, and efforts are made to describe the sensitivity of parameter variations on the calculated results.

NASA Discipline Neuroscience↗

Link Analysis of High Throughput Spacecraft Communication Systems for Future Science Missions

NASA's plan to launch several spacecraft into low Earth Orbit (LEO) to support science missions in the next ten years and beyond requires down link throughput on the order of several terabits per day. The ability to handle such a large volume of data far exceeds the capabilities of current systems. This paper proposes two solutions, first, a high data rate link between the LEO spacecraft and ground via relay satellites in geostationary orbit (GEO). Second, a high data rate direct to ground link from LEO. Next, the paper presents results from computer simulations carried out for both types of links taking into consideration spacecraft transmitter frequency, EIRP, and waveform; elevation angle dependent path loss through Earths atmosphere, and ground station receiver GT.

Antennas↗

Link Analysis of High Throughput Spacecraft Communication Systems for Future Science Missions

NASA's plan to launch several spacecrafts into low Earth Orbit (LEO) to support science missions in the next ten years and beyond requires down link throughput on the order of several terabits per day. The ability to handle such a large volume of data far exceeds the capabilities of current systems. This paper proposes two solutions, first, a high data rate link between the LEO spacecraft and ground via relay satellites in geostationary orbit (GEO). Second, a high data rate direct to ground link from LEO. Next, the paper presents results from computer simulations carried out for both types of links taking into consideration spacecraft transmitter frequency, EIRP, and waveform; elevation angle dependent path loss through Earths atmosphere, and ground station receiver GT.

Amplifier↗

The Joint ESA/NASA Galileo/GPS Receiver Onboard the ISS – the GARISS Project

ESA and NASA conducted a joint Galileo/GPS space receiver experiment on-board the International Space Station (ISS). The objectives (Enderle 2017) of the joint project were to demonstrate the robustness of a combined Galileo/GPS waveform uploaded to NASA hardware already operating in the challenging space environment - the SCaN (Space Communications and Navigation) software defined radio (SDR) testbed (FPGA) - on-board the ISS. These activities data included the analysis of the Galileo/GPS signal and on-board Position/Velocity/Time (PVT) performance, processing of the Galileo/GPS raw data (code- and carrier phase) for Precise Orbit Determination (POD), and validate the added value of a space-borne dual GNSS receiver compared to a single-system GNSS receiver operating under the same conditions. This paper will provide a general overview of the Galileo/GPS experiment – called GARISS - on-board the ISS, describe design, test and validation and also the operations of the experiment. Further, the various analysis conducted in the con is joint project and also the results obtained will be presented with a focus on the (Precise) Orbit Determination results.

Enderle, Werner↗

Implementation of a High-Speed Multichannel Data Acquisition System for Magnetic Diagnostics and Plasma Centroid Position Control in ISTTOK

In tokamak and other fusion devices, magnetic control is the main tool that allows to regulate the plasma current, position and shape; it is in charge of actuating the desired plasma current waveform, steering the plasma position to a given set point and maintain the plasma shape close to a prescribed plasma equilibrium. This work describes the application of several physics concepts and computational tools in order to obtain a novel optimal controller for the plasma centroid position, which has been implemented and tested in the real-time plasma control system at the ISTTOK tokamak. A key point for the development of the new control system was the installation of a recently upgraded hardware, that numerically integrates in real-time the magnetic probes signals.

poloidal field coils↗

Waveform Modeling and Simulation for Crustal Phases [Slides]

Goals for this project are to: numerically simulate wave propagation in layered crustal models with laterally-varying structure; Investigate seismic phases Pg and Pn; help understand the variability and complexity of these phases in recorded seismic data; and Use wavefield movies and "wavepaths" to suggest improvements for SALSA3D crustal tomography. In this presentation I will outline progress that has been made to date in an effort to modify a community research modeling code ("simulator")into a tool which can be used by GNDD researchers to study the effect of varying crustal velocity on wavefield propagation.

58 GEOSCIENCES↗

Performance of the GLAS Space Lidar Receiver Through Its Seven-Year Space Mission

NASA s Ice, Cloud, and land Elevation Satellite (ICESat) mission [1,2] carrying the Geoscience Laser Altimeter System (GLAS) Instrument, was launched on January 12, 2003. The three lasers on ICESat have made a total of 1.98 billion laser shot measurements of the Earth s surface and atmosphere during its 17 science data collection campaigns over its seven year operating lifetime. ICESat completed its science mission after the last laser stopped operating in October 2009. The spacecraft was de-orbited on August 30, 2010. The GLAS instrument carried 3 diode-pumped Q-switched Nd:YAG lasers, which emitted 6-nsec wide pulses at 1064 and 532 nm at a 40-Hz rate. There are three lidar receiver channels, a 1064 nm surface altimetry channel, a 1064 nm cloud backscattering lidar channel, and a 532 nm cloud and aerosol backscattering lidar channel. The altimetry and cloud backscatter channels used Si avalanche photodiode (APD) operated in analog mode as in the Mars Global Surveyor s Mars Orbital Laser Altimeter [3,4]. GLAS also utilized a number of new technologies and techniques for space lidar, including passively Q-switched diode-pumped Nd:YAG lasers, a 1-m diameter telescope, a temperature tuned etalon optical bandpass filter, Si APD single photon counting detectors, 1 Gsample/sec waveform digitizers, ultra stable clock oscillators, and digital signal processing and detection algorithms [5]. A global position system (GPS) receiver was used to provide the spacecraft position and epoch times. The ICESat mission provided a unique opportunity to monitor the lidar component performance in the space environment over a multi-year time period. We performed a number of engineering tests periodically to monitor the lidar receiver performance, including receiver sensitivity, timing precision, detector dark noise, etc. A series of engineering tests were also performed after the end of the science mission to evaluate the performance of the spare detector, oscillator, waveform digitizer, and GPS receiver. An experiment was conducted which pointed GLAS to Venus to test the receiver sensitivity to star light and to verify GLAS bore sight with respect to the spacecraft coordinate system. These tests provided unique data to assess the degradation and the rate of change of these key lidar components due to space radiation and aging. They also helped to validate new techniques to operate and calibrate future space lidars.

Sun, Xiaoli↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Elastic Stochastic Full Waveform Inversion (eSFWI)

This collaboration between Lawrence Livermore National Security, LLC (LLNS) as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Chevron USA Inc., acting through its Chevron Technical Center division, aimed at developing next-generation computational methods for the Elastic Stochastic Full Waveform Inversion (eSFWI). Seismic imaging is heavily used in the oil and gas industry for identifying and operating subsurface reservoirs. Improved seismic imaging methods can improve productivity, lower costs, and improve operational and environmental safety. This CRADA demonstrated that new high-performance computing (HPC) architectures being rolled out over the next five years can enable unprecedented seismic imaging resolution when using eSFWI techniques to process active seismic data. An open-source computational mini-application was developed, capable of demonstrating near-peak performance for eSFWI algorithms on CPU and GPU enabled HPC platforms. Performance was demonstrated on LLNL HPC systems such as Lassen, as well as on Chevron systems. This project benefited Chevron USA Inc. by demonstrating the potential computational efficiency of their full waveform inversion capabilities used to characterize oil/gas reservoirs, which in turn benefits the public through potential increases in capabilities to perform analysis of leasing sites.

04 OIL SHALES AND TAR SANDS↗

Estimation of cerebral blood flow velocity during breath-hold challenge using artificial neural networks

The effect of untreated Obstructive Sleep Apnoea (OSA) on cerebral haemodynamics and CA impairment is an active field of research interest. A breath-hold challenge is usually used in clinical and research settings to simulate cardiovascular and cerebrovascular changes that mimic OSA events. This work utilises temporal arterial oxygen saturation (SpO 2 ) and photoplethysmography (PPG) signals to estimate the temporal cerebral blood flow velocity (CBFv) waveform. Measurements of CBFv, SpO 2 , and PPG, were acquired concurrently from volunteers performing two different protocols of breath-hold challenge in the supine position. Past values of the SpO 2 and PPG signals were used to estimate the current values of CBFv using different permutations and topologies of supervised learning with shallow artificial neural networks (ANNs). Measurements from one protocol were used to train the ANNs and find the optimum topologies, which in turn were tested using the other protocol. Data collected from 10 normotensive, healthy subjects (four females, age 28.5 ± 6.1 years, Body Mass Index (BMI) 24.0 ± 4.7 kg/m 2 ) were used in this study. The results show that different subjects have different optimum topologies for ANNs, thus indicating the effects of inter-subject variability on ANNs. Successfully reconstructed blind waveforms for the same subject group in the second protocol showed a reasonable accuracy of 60–80% estimation compared to the measured waveforms.

59 BASIC BIOLOGICAL SCIENCES↗

Linear diffraction grating interferometer with high alignment tolerance and high accuracy

We present an innovative structure of a linear diffraction grating interferometer as a long stroke and nanometer resolution displacement sensor for any linear stage. The principle of this diffractive interferometer is based on the phase information encoded by the {+-}1st order beams diffracted by a holographic grating. Properly interfering these two beams leads to modulation similar to a Doppler frequency shift that can be translated to displacement measurements via phase decoding. A self-compensation structure is developed to improve the alignment tolerance. LightTool analysis shows that this new structure is completely immune to alignment errors of offset, standoff, yaw, and roll. The tolerance of the pitch is also acceptable for most installation conditions. In order to compact the structure and improve the signal quality, a new optical bonding technology by mechanical fixture is presented so that the miniature optics can be permanently bonded together without an air gap in between. For the output waveform signals, a software module is developed for fast real-time pulse counting and phase subdivision. A laser interferometer HP5529A is employed to test the repeatability of the whole system. Experimental data show that within 15 mm travel length, the repeatability is within 15 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗