Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

High-gradient two-beam electron accelerator

The main goal for this project was to design, build, and evaluate a detuned-cavity, collinear, two-beam accelerator structure. Testing was to be at the Yale University Beam Physics Laboratory, under terms of a sub-grant from Omega-P to Yale. Facilities available at Yale for this project include a 6-MeV S-band RF gun and associated beam line for forming and transporting a ~1 A drive beam , a 300 kV beam source for use as a test beam, and a full panoply of laboratory infrastructure and test equipment. During the first year of this project, availability and functionality of the 6-MeV drive beam and 300 kV test beam were confirmed, and the beam line was restored to a layout to be used with the two-beam accelerator project. Major efforts during the first year were also focused on computational design and simulation of the accelerator structure itself, on beam dynamics, and on beam transport. Effort during the second year was focussed on building and preparing to test the structure, including extensive cold testing. Detailed results from work under this project have been published in twelve archival journal articles, listed in Section IV of the technical report.

43 PARTICLE ACCELERATORS↗

Experimental parameters for plasma wakefield acceleration in a narrow plasma column

Recent theoretical advancements propose multiple positron acceleration schemes in plasma wakefield acceleration (PWFA). One of the most promising ideas involves the creation of an electron-driven blowout wake within a finite-radius pre-ionized plasma column. This leads to the formation of an elongated region of sheath electrons at the closing of the first wake period capable of accelerating positrons while simultaneously providing a transverse focusing force. Additionally, the proposed scheme has shown to be a potential means of suppressing instabilities. We present an experimental opportunity to explore the narrow column PWFA at the Facility for Advanced Accelerator Experimental Tests II (FACET-II): the E333 experiment. As a pivotal first step towards achieving positron acceleration in PWFA, we have planned a precursor experiment utilizing the currently available single-bunch electron beam to study the physics of the narrow plasma PWFA scheme. We outline the feasible experimental parameters, including beam and ionization laser parameters, along with the required laser optics for the experiment. The primary observable signatures for this stage of the experiment are the final energy spectrum and transverse position of the electron bunch, anticipating reduced energy loss and enhanced beam guidance in the narrow plasma column compared to the nominal PWFA. Comprehensive simulations are used to detail our experimental plan.

Lee, Valentina [University of Colorado, Boulder, C↗

EVALUATION OF REQUIREMENTS FOR THE DWPF HIGHER CAPACITY CANISTER

The Defense Waste Processing Facility (DWPF) is considering the option to increase canister glass capacity by reducing the wall thickness of the current production canister. This design has been designated as the DWPF Higher Capacity Canister (HCC). A significant decrease in the number of canisters processed during the life of the facility would be achieved if the HCC were implemented leading to a reduced overall reduction in life cycle costs. Prior to implementation of the change, Savannah River National Laboratory (SRNL) was requested to conduct an evaluation of the potential impacts. The specific areas of interest included loading and deformation of the canister during the filling process. Additionally, the effect of the reduced wall thickness on corrosion and material compatibility needed to be addressed. Finally the integrity of the canister during decontamination and other handling steps needed to be determined. The initial request regarding canister fabrication was later addressed in an alternate study. A preliminary review of canister requirements and previous testing was conducted prior to determining the testing approach. Thermal and stress models were developed to predict the forces on the canister during the pouring and cooling process. The thermal model shows the HCC increasing and decreasing in temperature at a slightly faster rate than the original. The HCC is shown to have a 3°F ΔT between the internal and outer surfaces versus a 5°F ΔT for the original design. The stress model indicates strain values ranging from 1.9% to 2.9% for the standard canister and 2.5% to 3.1% for the HCC. These values are dependent on the glass level relative to the thickness transition between the top head and the canister wall. This information, along with field readings, was used to set up environmental test conditions for corrosion studies. Small 304-L canisters were filled with glass and subjected to accelerated environmental testing for 3 months. No evidence of stress corrosion cracking was indicated on either the canisters or U-bend coupons. Calculations and finite element modeling were used to determine forces over a range of handling conditions along with possible forces during decontamination. While expected reductions in some physical characteristics were found in the HCC, none were found to be significant when compared to the required values necessary to perform its intended function. Based on this study and a review of successful testing of thinner canisters at West Valley Demonstration Project (WVDP), the mechanical properties obtained with the thinner wall do not significantly undermine the ability of the canister to perform its intended function.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Libera Brilliance Test with Beam Signal

The purpose of the tests described below was to estimate performance of Libera Brilliance with real circulating beam signal in the accelerator environment. Tests were performed at CESR and APS. Comprehensive test of the Libera Brilliance with real beam was performed. The obtained results are in accordance with previously obtained on the stand. Single pass capabilities of the Libera Brilliance were studied and found corresponding to the requirements. There is excellent agreement between observations of beam motion with a Libera Brilliance and APS FPGA-based receiver, with the Libera Brilliance unit having less noise in the high-frequency part of spectrum. For fill pattern dependence Libera Brilliance outperformed both the APS FPGA-based unit and the Bergoz BPM receiver.

43 PARTICLE ACCELERATORS↗

Libera Brilliance Test with Beam Signal

The purpose of the tests described below was to estimate performance of Libera Brilliance with real circulating beam signal in the accelerator environment. Tests were performed at CESR and APS.

36 MATERIALS SCIENCE↗

Essay: Robert H. Siemann As Leader of the Advanced Accelerator Research Department

Robert H. Siemann originally conceived of the Advanced Accelerator Research Department (AARD) as an academic, experimental group dedicated to probing the technical limitations of accelerators while providing excellent educational opportunities for young scientists. The early years of the Accelerator Research Department B, as it was then known, were dedicated to a wealth of mostly student-led experiments to examine the promise of advanced accelerator techniques. High-gradient techniques including millimeter-wave rf acceleration, beam-driven plasma acceleration, and direct laser acceleration were pursued, including tests of materials under rf pulsed heating and short-pulse laser radiation, to establish the ultimate limitations on gradient. As the department and program grew, so did the motivation to found an accelerator research center that brought experimentalists together in a test facility environment to conduct a broad range of experiments. The Final Focus Test Beam and later the Next Linear Collider Test Accelerator provided unique experimental facilities for AARD staff and collaborators to carry out advanced accelerator experiments. Throughout the evolution of this dynamic program, Bob maintained a department atmosphere and culture more reminiscent of a university research group than a national laboratory department. His exceptional ability to balance multiple roles as scientist, professor, and administrator enabled the creation and preservation of an environment that fostered technical innovation and scholarship.

43 PARTICLE ACCELERATORS↗

Cosmic acceleration without dark energy: background tests and thermodynamic analysis

A cosmic scenario with gravitationally induced particle creation is proposed. In this model the Universe evolves from an early to a late time de Sitter era, with the recent accelerating phase driven only by the negative creation pressure associated with the cold dark matter component. The model can be interpreted as an attempt to reduce the so-called cosmic sector (dark matter plus dark energy) and relate the two cosmic accelerating phases (early and late time de Sitter expansions). A detailed thermodynamic analysis including possible quantum corrections is also carried out. For a very wide range of the free parameters, it is found that the model presents the expected behavior of an ordinary macroscopic system in the sense that it approaches thermodynamic equilibrium in the long run (i.e., as it nears the second de Sitter phase). Moreover, an upper bound is found for the Gibbons–Hawking temperature of the primordial de Sitter phase. Finally, when confronted with the recent observational data, the current 'quasi'-de Sitter era, as predicted by the model, is seen to pass very comfortably the cosmic background tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel Lightweight, Low-Cost Heliostat for Concentrating Solar Power (SBIR Phase I Final Report)

The overall goal of this Department of Energy (DOE) SBIR Phase I project was to demonstrate the feasibility of the L.Garde, Inc. heliostat mirror facet for use in concentrated solar power applications. Prior to this Phase I project, L.Garde, Inc. developed a design for a lightweight and low cost mirror facet and successfully fabricated small scale (0.667 m 2 ) with a mirror surface flatness of 0.7 mrad. Therefore, the focus of the Phase I effort was to (1) demonstrate scalability by fabricating larger size mirrors while retaining the same mirror surface flatness, (2) demonstrate the design can withstand operating environment conditions through field testing, and (3) perform cost analysis to show the heliostat mirror facet design can meet DoE goals of < 12 kg/m2 and <$30/m 2 . During the Phase I project, L.Garde successfully fabricated large area (1.395 m 2 ) heliostat mirror facets, with a mass per unit area of 8 kg/m 2 and a cost of $29.80/m 2 . Surface flatness measurements (using contact probe technique) were performed on the mirror surface and results showed a flatness of 0.68 mrad, which were in agreement with previously fabricated small scale mirror facets. Slope error measurements was also performed on the mirror surface and results showed a slope error of 0.77 mrad which also was in agreement with previously fabricated small scale mirror facets. One large area mirror facet was subjected to a three (3) month field test. Surface flatness and slope error measurements were performed on the mirror surface after the field test and results were 0.663 mrad and 0.58 mrad respectively. The large scale heliostat mirror facets were also subjected to accelerated aging. However, during this exposure we observed failure due to the breaking of the mirror facets. Further investigation into the source of the failure showed that the mirror component alone showed signs of degradation during the same accelerated aging test. We believe that moisture ingress is occurring when subjected to high humidity, leading to buildup of water with the layers of protective paints and resulting in mirror breakage when water expands in freezing conditions. In order to mitigate or eliminate this issue, a new weatherproofing strategy may be implemented or a new mirror component may be used that is able to survive accelerated aging conditions.

14 SOLAR ENERGY↗

Chapter 13: A Simple Estimation of UV Irradiance Under Clear-Sky Conditions

Accelerated aging tests are designed to estimate the useful life of products in their end-use environment. There is currently no simple way to answer the age-old question: “How long should I run my weathering test to reproduce 1 year of outdoor aging?” At the very least, there is need to (1) evaluate the acceleration rate associated with each stress factor and (2) estimate the intensity of the stress factors that the products under scrutiny are exposed to in natural aging. In this chapter, a model is introduced to calculate the ratio between ultraviolet (UV) irradiance and global horizontal irradiance (GHI). This method was empirically derived from measured or simulated irradiance data and validated against outdoor observations. This ratio provides a simple way to estimate the UV dose that samples are exposed to at any outdoor location.

ENERGY PLANNING, POLICY, AND ECONOMY,OTHER INSTRUM↗

High Performance non-PGM Transition Metal Oxide ORR Catalysts of PEMFCs

This project was designed to develop acid-stable PGM-free transition metal oxide oxygen reduction reaction (ORR) electrocatalysts to meet or exceed the performance and durability of the DOE 2020 Technical Targets for platinum-group metal (PGM) free electrocatalysts from first-principles to incorporation into membrane-electrode assemblies (MEAs) for polymer electrolyte membrane (PEM) fuel cells. The planned project was to accomplish this goal with a multi-step approach: 1) materials modeling and experimental screening to identify acid-stable oxides with high ORR activity, 2) optimization of catalyst particle size and catalyst/carbon/ionomer catalyst layer composition, 3) fabrication of MEAs for performance and durability testing. During the course of this project: 1) acid-stability descriptors were developed for manganese oxides; 2) a family of acid-stable multicomponent oxides based on antimony were developed; 3) a flexible synthesis for the formation of nanocrystalline nonstoichiometric oxides was developed; 4) limited ORR activity but modest and improving oxygen evolution reaction (OER) activity was measured for multicomponent antimony oxides. The project was programmed into five technical tasks: The development of acid-stable ORR electrocatalytic oxides through 1) identification and optimization of acid-stable oxide compositions, and 2) electrochemical characterization; 3) optimization of catalyst layer composition for MEAs using identified ORR electrocatalysts; 4) MEA fabrication and performance testing to result in performance of 44 mA-cm-2 at 0.9 V vs. RHE; and 5) accelerated-stress testing of optimized MEAs. Because no acid-stable oxide was identified with the requisite activity for ORR (4.4 µA-cm-2oxide intrinsic activity at 0.9 V vs. RHE) within the time and budget allotted in Tasks 1 and 2, the project was halted at the end of phase 1, with no activity in Tasks 3-5. The research output, while not succeeding in developing ORR electrocatalysts, advanced the development of acid-stable oxide materials, showing potential for further improvement as OER electrocatalysts.

08 HYDROGEN↗

EDS Analysis of FCCI in AFC-FAST Fuel Pins

The Advanced Fuel Campaign’s Fission Accelerated Steady-state Testing (FAST) program uses metallic fuel pins with small diameters to reach a desired burnup more quickly. This enables accelerated testing of advanced fuel designs and decreases the time between idea conception and commercial usage. Post-irradiation examination is critical in this process, especially with respect to the fuel-cladding chemical interactions (FCCI). In this work, energy dispersive X-ray spectroscopy (EDS) is used to track how elements from the fuel and fission products have diffused through the cladding. Elemental redistribution along the fuel-cladding interface is mapped and FCCI region thicknesses are measured. The correlations between geometry, temperature, burnup, and FCCI thickness are presented.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Definition of Capabilities Needed for a Single Event Effects Test Facility

The Federal Aviation Administration (FAA) is contemplating new regulations mandating testing of the vulnerability of flight-critical avionics to single event effects (SEE). A limited number of high-energy neutron test facilities currently serve the SEE industrial and institutional research community. The FAA recognizes that existing facilities have insufficient test capacity to meet new demand from such mandates; it desires more flexible irradiation capabilities to test complete, large systems and would like capabilities to address greater concerns for thermal neutrons. For this reason, the FAA funded this study by Spallation Neutron Source (SNS) staff with the ultimate aim of developing options for SEE test facilities using high-energy neutrons at the SNS complex. After an investigation of current SEE test practices and assessment of future testing requirements, three concepts were identified covering a range of test functionality, neutron flux levels, and fidelity to the atmospheric neutron spectrum. The costs and times required to complete each facility were also estimated. SEE testing is generally performed by accelerating the event rate to a point where the effects are still dominated by single events and double event causes of failures are negligible. In practice, acceleration factors of as high as 10 6 are applicable for component testing, whereas for systems testing acceleration factors of 10 4 seem to be the upper limit. It is strongly desirable that the irradiation facility be tunable over a large range of high-energy neutron fluxes of 10 2 - 10 4 n/cm²/s for systems testing and from 10 4 - 10 7 n/cm²/s for components testing. The most capable, most flexible, and highest-test-capacity option is a new stand-alone target station named the High-Energy neutron Test Station (HETS). It is also the most expensive option, with a cost to complete of approximately $100 million. Dual test enclosures would allow for simultaneous testing activity effectively doubling overall test capacity per HETS operating hour. Using about 1 kilowatt (kW) of proton power extracted from the accelerator before injection in the accumulator ring, its operation would be unnoticeable by neutron scattering users at the SNS target station. The H beam laser stripping technique would allow for control of beam power on the HETS target independent from power delivered to the SNS. Large systems with frontal areas of up to 1 x 2 m² could be accommodated with integral high-energy flux values (above 10 megaelectron-volt, or MeV) to at most 10 4 n/cm²/s; components could also be tested with flux levels to at most 10 7 n/cm²/s on beam sizes of up to 0.2 x 0.2 m². Selectable moderating material and neutron filters would allow tailoring of the neutron spectrum to user demands; charged particle deflectors could be switched to allow or deflect protons, pions, and muons. It is estimated that HETS would take 5 years to complete after award of contract, including engineering design and construction. Commissioning would take at least another 6 months. Interference with SNS principal operations was not considered in the construction time estimate; connection of the proton transport line and tunnel from the accelerator high energy beam transport (HEBT) and construction around existing site utilities would require careful planning and coordination with beam operations at the SNS. A high-energy (HE) neutron test facility using an available beam line on the SNS target station is a technically and financially attractive option. Inspired by the new ChipIR instrument on the ISIS TS 2 spallation source in the UK, a similar facility could be placed on an unused beam line in the SNS instrument hall [e.g., on beam line 8 (both A and B channels would be needed) or on beam line 10]. The performance would approach that of an HETS (~80%), but it would be operationally more limited, with only a single user at a time. Space is more limited, so the maximum system size would be about half of that in an HETS. Flexibility to tailor the spectrum would be somewhat more limited. While this concept was not as fully developed and characterized, preliminary work indicates very high HE flux levels should be possible, with ample thermal neutrons as well. Flux control would be more difficult than at HETS because proton power on target be whatever the SNS was operating at for neutron scattering. Neutron attenuation devices would have to be employed with as-yet undetermined control resolution. However, no new buildings would be needed, and the necessary utilities are already present in the SNS Experiment Hall. The estimated cost for a beam line option is around $15 million; the time to complete would be 3 years after award of contract, plus at least 6 months for commissioning. Interference of construction activities with SNS operations should be negligible. This option would require negotiation with the Department of Energy Basic Energy Sciences (BES) office -- the primary stakeholder of SNS -- for an application outside the usual scope of neutron scattering sciences. Furthermore, these presently open beam lines are highly desirable locations for proposed neutron scattering instruments and obtaining one of them for an SEE test facility will come only with persuasive and timely arguments to SNS leadership and the DOE BES. The third option is a tunnel extension/target cave facility providing the most basic system-level irradiation capability with minimal flexibility. Again not as well developed a concept as HETS, it would use a laser-stripping technique like an HETS, redirecting protons to a tunnel similar to the initial HETS proton transport tunnel. Indeed, this concept is intended to be upgradable to a full HETS facility. Only a small fraction of a watt of proton power would be used in this basic configuration, though. An uncooled target and primitive shielding arrangement would provide beam on modestly sized systems that must be placed in close proximity to the target. The neutron fluence would be less uniform over the system than with the HETS or the beam line option. A data acquisition room and support area would be located on the ground level; access to the target cave would be via elevator and/or stairway. As a result of the required excavation, new tunnel construction, shielding, data acquisition building, utilities, and other items, the estimated cost is $30 million. The time to complete is expected be more than 3 years; here again construction interference with SNS operations has not been accounted for, but it could have a significant impact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Long Term Creep Using Strain Rate Matching From the Stepped Isostress Method

Creep testing is an ongoing need, particularly with the development of new candidate alloy systems for advanced energy systems. The conventional creep test (CT) is regarded as a proven method to gather creep data however, the test is impractical due to being real-time: lasting up to 105 hours to characterize the service of long-lived turbomachinery components. Accelerated methods to gather the long-term creep properties of materials are needed to reduce the time to qualification of new materials. The time-temperature-stress-superposition principle (TTSSP) and the derivative time-temperature superposition principle (TTSP), time-stress superposition principle (TSSP), stepped isothermal method (SIM), and stepped isostress method (SSM) are accelerated creep tests (ACT) commonly used to predict the long-term creep behaviors of polymers and composites. The TTSP and TSSP tests require multiple specimen tested at various temperatures/stresses whereas the SIM and SSM tests employ a single specimen where temperature/stress are periodically step increased until rupture. The stepped creep deformation curve can then be time and strain shifted to produce a master creep curve. While these ACTs are useful tools to predict long-term creep, the drawback is the lack of mathematical laws to determine the virtual start time and time shift factors, especially for different materials. In this paper, a new self-calibration approach is developed and compared to existing SSM data for Kevlar 49. This new approach focuses on matching the creep strain rates between stress steps and fitting the data to a master curve using a modified theta projection model. This is performed using a MATLAB code consisting of five subroutines. The first subroutine takes the stress, time, and creep strain from SSM/SIM tests, and segregates the data intro arrays corresponding to each stress level. The second subroutine finds the constants for the modified theta projection model for each stress level. The third subroutine performs a time shift adjustment using creep strain rate matching. The fourth subroutine calculates the accelerated time of rupture. The last subroutine generates accelerated creep versus time plots. Kevlar 49 SSM data is gathered from literature and run through the MATLAB code. The master curves generated from the MATLAB are compared to the conventional creep curve of Kevlar 49 as well as the master curve gathered from literature in order to validate the feasibility of this new approach. The goal of this project is to vet if the self-calibration approach can produce results similar to the reference calibration approach.

36 MATERIALS SCIENCE↗

DIELECTRIC WALL ACCELERATOR TECHNOLOGY

The dielectric wall accelerator (DWA) is a compact pulsed power device where the pulse forming lines, switching, and vacuum wall are integrated into a single compact geometry. For this effort, we initiated a extensive compact pulsed power development program and have pursued the study of switching (gas, oil, laser induced surface flashover and photoconductive), dielectrics (ceramics and nanoparticle composites), pulse forming line topologies (asymmetric and symmetric Blumleins and zero integral pulse forming lines), and multilayered vacuum insulator (HGI) technology. Finally, we fabricated an accelerator cell for test on ETAII (a 5.5 MeV, 2 kA, 70 ns pulsewidth electron beam accelerator). We review our past results and report on the progress of accelerator cell testing.

43 PARTICLE ACCELERATORS↗

Representative Modules for Accelerated Thermal Cycling and Static Load Testing

In this work, we explore the influence of module size on the rate of interconnect solder bond thermomechanical fatigue (TMF) damage and the probability of cell fracture. For the solder bond TMF damage evaluation, structural mechanics models of crystalline silicon PV models are created to solve with the Finite Element Method. For the probability of cell fracture evaluation, Weibull analysis and weakest link theory are employed to resolve the probability of crystalline silicon PV cell fracture when measured as bare cells and when stressed in reduced- and full-sized modules. Results conclusively demonstrate that the rate of solder bond TMF damage is independent of module size, interconnect location across the cell and cell location across the module and that smaller, representative, modules must be loaded to a much higher level than their parent full-sized modules to achieve an equivalent driving force for cell fracture.

accelerated testing↗

Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

14 SOLAR ENERGY↗