Search NASA⌕ Search

SEARCH · Search NASA

Results for “clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Consistency relations and conservation of ζ in holographic inflation

It is well known that, in single clock inflation, the curvature perturbation ζ is constant in time on superhorizon scales. In the standard bulk description this follows quite simply from the local conservation of the energy momentum tensor in the bulk. On the other hand, in a holographic description, the constancy of the curvature perturbation must be related to the properties of the RG flow in the boundary theory. Here, we show that, in single clock holographic inflation, the time independence of correlators of ζ follows from the absence of the anomolous dimension of the energy momentum tensor in the boundary theory, and from the so-called consistency relations for vertex functions with a soft leg.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

A sub-picosecond digitally-controlled phase delay

The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.

Instruments & Instrumentation↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Half-life of 67 Cu

The half-life of 67 Cu was determined through serial gamma-ray spectrometry measurements of the dominant gamma emission (E γ : 184.6 keV; branching ratio: 48.7%) produced following β- decay. Data were collected consecutively for 1000 s per measurement, with a total of 3063 measurements over the duration of 36 days. The incidence rate for the 184.6 keV gamma-ray was determined from the spectral peak area and duration of each measurement. This rate was then corrected to account for detector dead-time, radioactive decay during each acquisition and drift in the computer clock in comparison to NIST nuclear clock. Least-squares regression analysis was performed to determine the half-life of 67 Cu. The result was 61.761 ± 0.004 h, which is the highest precision measurement to date, and marks a 24-fold precision improvement over the current Nuclear Data Sheets value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ECHO: an application for detection and analysis of oscillators identifies metabolic regulation on genome-wide circadian output

Abstract Motivation Time courses utilizing genome scale data are a common approach to identifying the biological pathways that are controlled by the circadian clock, an important regulator of organismal fitness. However, the methods used to detect circadian oscillations in these datasets are not able to accommodate changes in the amplitude of the oscillations over time, leading to an underestimation of the impact of the clock on biological systems. Results We have created a program to efficaciously identify oscillations in large-scale datasets, called the Extended Circadian Harmonic Oscillator application, or ECHO. ECHO utilizes an extended solution of the fixed amplitude oscillator that incorporates the amplitude change coefficient. Employing synthetic datasets, we determined that ECHO outperforms existing methods in detecting rhythms with decreasing oscillation amplitudes and in recovering phase shift. Rhythms with changing amplitudes identified from published biological datasets revealed distinct functions from those oscillations that were harmonic, suggesting purposeful biologic regulation to create this subtype of circadian rhythms. Availability and implementation ECHO’s full interface is available at https://github.com/delosh653/ECHO. An R package for this functionality, echo.find, can be downloaded at https://CRAN.R-project.org/package=echo.find. Supplementary information Supplementary data are available at Bioinformatics online.

De los Santos, Hannah↗

A universal and constant rate of gene content change traces pangenome flux to LUCA

Abstract Prokaryotic genomes constantly undergo gene flux via lateral gene transfer, generating a pangenome structure consisting of a conserved core genome surrounded by a more variable accessory genome shell. Over time, flux generates change in genome content. Here, we measure and compare the rate of genome flux for 5655 prokaryotic genomes as a function of amino acid sequence divergence in 36 universally distributed proteins of the informational core (IC). We find a clock of gene content change. The long-term average rate of gene content flux is remarkably constant across all higher prokaryotic taxa sampled, whereby the size of the accessory genome—the proportion of the genome harboring gene content difference for genome pairs—varies across taxa. The proportion of species-level accessory genes per genome, varies from 0% (Chlamydia) to 30%–33% (Alphaproteobacteria, Gammaproteobacteria, and Clostridia). A clock-like rate of gene content change across all prokaryotic taxa sampled suggest that pangenome structure is a general feature of prokaryotic genomes and that it has been in existence since the divergence of bacteria and archaea.

Microbiology↗

Light quality modulates metabolic synchronization over the diel phases of crassulacean acid metabolism

Temporal compartmentation of carboxylation processes is a defining feature of crassulacean acid metabolism and involves circadian control of key metabolic and transport steps that regulate the supply and demand for carbon over a 24h cycle. Recent insights on the molecular workings of the circadian clock and its connection with environmental inputs raise new questions on the importance of light quality and, by analogy, certain photoreceptors for synchronizing the metabolic components of CAM. The present work tested the hypothesis that optimal coupling of stomatal conductance, net CO2 uptake, and the reciprocal turnover of carbohydrates and organic acids over the diel CAM cycle requires both blue and red light input signals. Contrasting monochromatic wavelengths of blue, green, and red light (i.e. 475, 530, 630nm) with low fluence rates (10 μmol m–2 s–1) were administered for 16 hours each diel cycle for a total treatment time of 48 hours to the obligate CAM bromeliad, Aechmea ‘Maya’. Of the light treatments imposed, low-fluence blue light was a key determinant in regulating stomatal responses, organic acid mobilization from the vacuole, and daytime decarboxylation. However, the reciprocal relationship between starch and organic acid turnover that is typical for CAM was uncoupled under low-fluence blue light. Under low-fluence red or green light, the diel turnover of storage carbohydrates was orchestrated in line with the requirements of CAM, but a consistent delay in acid consumption at dawn compared with plants under white or low-fluence blue light was noted. Consistent with the acknowledged influences of both red and blue light as input signals for the circadian clock, the data stress the importance of both red and blue-light signalling pathways for synchronizing the metabolic and physiological components of CAM over the day/night cycle.

54 ENVIRONMENTAL SCIENCES↗

Floquet operator dynamics and orthogonal polynomials on the unit circle

Operator spreading under stroboscopic time evolution under a unitary is studied. An operator Krylov space is constructed and mapped to orthogonal polynomials on a unit circle (OPUC), as well as to the Krylov space of the edge operator of the Floquet transverse field Ising model with inhomogeneous couplings (ITFIM). The Verblunsky coefficients in the OPUC representation are related to the Krylov angles parametrizing the ITFIM. The relations between the OPUC and spectral functions are summarized and several applications are presented. These include derivation of analytic expressions for the OPUC under persistent m-periodic dynamics, and the numerical construction of the OPUC for autocorrelations of the homogeneous Floquet-Ising model as well as the Z 3 clock model. The numerically obtained Krylov angles of the Z 3 clock model with long-lived period tripled autocorrelations show a spatial periodicity of six, and this observation is used to develop an analytically solvable model for the ITFIM that mimics this behavior.

Floquet systems↗

YbH + formation in an ytterbium ion trap

The trapped 171 Yb + ion is a promising candidate for portable atomic clock applications. However, with buffer-gas cooled ytterbium ions, the ions can be pumped into a low-lying 2 F 7 / 2 state or form YbH + molecules. These dark states reduce the fluorescence signal from the ions and can degrade the clock stability. In this work, we study the dynamics of the populations of the 2 F 7 / 2 state and YbH + molecules under different operating conditions of our 171 Yb + ion system. Our study indicates that 2 F 7 / 2 -state ions can form YbH + molecules through interactions with hydrogen gas. As observed previously, dissociation of YbH + is observed at wavelengths around 369 nm. We also demonstrate YbH+ dissociation using 405 nm light. Moreover, we show that the population in the dark states can be limited by using a single repump laser at 935 nm. Our study provides insights into the molecular formation in a trapped ion system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Search for variation of fundamental constants and violations of fundamental symmetries using isotope comparisons

Atomic microwave clocks based on hyperfine transitions, such as the caesium standard, tick with a frequency that is proportional to the magnetic moment of the nucleus. This magnetic moment varies strongly between isotopes of the same atom, while all atomic electron parameters remain the same. Therefore the comparison of two microwave clocks based on different isotopes of the same atom can be used to constrain variation of fundamental constants. In this paper, we calculate the neutron and proton contributions to the nuclear magnetic moments, as well as their sensitivity to any potential quark-mass variation, in a number of isotopes of experimental interest including {sup 201,199}Hg and {sup 87,85}Rb, where experiments are underway. We also include a brief treatment of the dependence of the hyperfine transitions to variation in nuclear radius, which in turn is proportional to any change in quark mass. Our calculations of expectation values of proton and neutron spin in nuclei are also needed to interpret measurements of violations of fundamental symmetries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Classification of electronic nematicity in three-dimensional crystals and quasicrystals

Electronic nematic order has been reported in a rich landscape of materials, encompassing not only a range of intertwined correlated and topological phenomena but also different underlying lattice symmetries. Motivated by these findings, we investigate the behavior of electronic nematicity as the spherical symmetry of three-dimensional (3D) space is systematically lowered by the lattice environment. Here, we consider all 32 crystallographic point groups as well as four major classes of quasicrystalline point groups, given the recent observations of electronic phases of interest in quasicrystalline materials and artificial twisted quasicrystals. Valuable insights are gained by establishing a mapping between the five-component charge-quadrupolar nematic order parameter of the electronic fluid and the 3D tensorial order parameter of nematic liquid crystals. We find that a uniaxial nematic state is only generically realized in polyhedral point groups (icosahedral and cubic), with the nematic director pointing along different sets of rotational symmetry axes. Interestingly, icosahedral point groups are the only ones in which the five nematic order parameter components transform as the same irreducible representation, making them the closest analog of 3D isotropic nematics. In axial point groups, one of the nematic components is always condensed, whereas the other four components decompose into an in-plane and an out-of-plane nematic doublet, resulting in biaxial nematic ground states. Because these two nematic doublets behave as Z q clock order parameters, this allows us to identify the types of crystals and quasicrystals that can host interesting electronic nematic phenomena enabled by the critical properties of the q ≥ 4 clock model, such as emergent continuous nematic fluctuations in 3D, critical phases with quasi-long-range nematic order in two dimensions (2D), and Ashkin-Teller nematicity in 2D.

3-dimensional systems↗

Entropic Energy-Time Uncertainty Relation

We report that energy-time uncertainty plays an important role in quantum foundations and technologies, and it was even discussed by the founders of quantum mechanics. However, standard approaches (e.g., Robertson’s uncertainty relation) do not apply to energy-time uncertainty because, in general, there is no Hermitian operator associated with time. Following previous approaches, we quantify time uncertainty by how well one can read off the time from a quantum clock. We then use entropy to quantify the information-theoretic distinguishability of the various time states of the clock. Our main result is an entropic energy-time uncertainty relation for general time-independent Hamiltonians, stated for both the discrete-time and continuous-time cases. Additionally, our uncertainty relation is strong, in the sense that it allows for a quantum memory to help reduce the uncertainty, and this formulation leads us to reinterpret it as a bound on the relative entropy of asymmetry. Because of the operational relevance of entropy, we anticipate that our uncertainty relation will have information-processing applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systematic Construction of Scarred Many-Body Dynamics in 1D Lattice Models

In this paper, we introduce a family of nonintegrable 1D lattice models that feature robust periodic revivals under a global quench from certain initial product states, thus generalizing the phenomenon of many-body scarring recently observed in Rydberg atom quantum simulators. Our construction is based on a systematic embedding of the single-site unitary dynamics into a kinetically constrained many-body system. We numerically demonstrate that this construction yields new families of models with robust wave-function revivals, and it includes kinetically constrained quantum clock models as a special case. We show that scarring dynamics in these models can be decomposed into a period of nearly free clock precession and an interacting bottleneck, shedding light on their anomalously slow thermalization when quenched from special initial states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dipole-Dipole Frequency Shifts in Multilevel Atoms

Dipole-dipole interactions lead to frequency shifts that are expected to limit the performance of next-generation atomic clocks. In this work, we compute dipolar frequency shifts accounting for the intrinsic atomic multilevel structure in standard Ramsey spectroscopy. When interrogating the transitions featuring the smallest Clebsch-Gordan coefficients, we find that a simplified two-level treatment becomes inappropriate, even in the presence of large Zeeman shifts. Further, for these cases, we show a net suppression of dipolar frequency shifts and the emergence of dominant nonclassical effects for experimentally relevant parameters. Our findings are pertinent to current generations of optical lattice and optical tweezer clocks, opening a way to further increase their current accuracy, and thus their potential to probe fundamental and many-body physics.

74 ATOMIC AND MOLECULAR PHYSICS↗

An Open-Access Repository of Synchrophasor Data Quality Examples: Curation and Example Applications

Synchrophasor measurements are critical in providing wide-area situational awareness to power system operators. However, data artifacts may be introduced due to various issues such as loss of communication, loss of GPS signal, internal clock error, and vendor-specific implementation of phasor estimation algorithms. Tools designed to provide actionable insights from synchrophasor data, hence, must be designed to be robust to these data quality issues. In this work, two years of synchrophasor data sourced from multiple electric utilities in the United States were analyzed to identify examples of data quality problems. These examples were then labeled and published in the Grid Event Signature Library, a publicly available repository of power system measurements hosted by the Oak Ridge National Laboratory. This paper describes the data curation process, and illustrates two application use cases where the dataset can be valuable to the research community. In the first use case, a random forest classifier is trained to distinguish power system disturbance signatures from data anomalies introduced in synchrophasor measurements due to clock errors. The second use case studies the impact of data quality issues on an example synchrophasor application (specifically, event start time determination). The choice of data quality problems investigated is informed by the examples in the repository curated in this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An on-line acoustic fluorocarbon coolant mixture analyzer for the ATLAS silicon tracker

The ATLAS silicon tracker community foresees an upgrade from the present octafluoro-propane (C{sub 3}F{sub 8}) evaporative cooling fluid - to a composite fluid with a probable 10-20% admixture of hexafluoro-ethane (C{sub 2}F{sub 6}). Such a fluid will allow a lower evaporation temperature and will afford the tracker silicon substrates a better safety margin against leakage current-induced thermal runaway caused by cumulative radiation damage as the luminosity profile at the CERN Large Hadron Collider increases. Central to the use of this new fluid is a new custom-developed speed-of-sound instrument for continuous real-time measurement of the C{sub 3}F{sub 8}/C{sub 2}F{sub 6} mixture ratio and flow. An acoustic vapour mixture analyzer/flow meter with new custom electronics allowing ultrasonic frequency transmission through gas mixtures has been developed for this application. Synchronous with the emission of an ultrasound 'chirp' from an acoustic transmitter, a fast readout clock (40 MHz) is started. The clock is stopped on receipt of an above threshold sound pulse at the receiver. Sound is alternately transmitted parallel and anti-parallel with the vapour flow for volume flow measurement from transducers that can serve as acoustic transmitters or receivers. In the development version, continuous real-time measurement of C{sub 3}F{sub 8}/C{sub 2}F{sub 6} flow and calculation of the mixture ratio is performed within a graphical user interface developed in PVSS-II, the Supervisory, Control and Data Acquisition standard chosen for LHC and its experiments at CERN. The described instrument has numerous potential applications - including refrigerant leak detection, the analysis of hydrocarbons, vapour mixtures for semiconductor manufacture and anesthetic gas mixtures. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗