Search NASA⌕ Search

SEARCH · Search NASA

Results for “coating system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Assessment and Control of Spacecraft Charging Risks on the International Space Station

Electrical interactions between the F2 region ionospheric plasma and the 160V photovoltaic (PV) electrical power system on the International Space Station (ISS) can produce floating potentials (FP) on the ISS conducting structure of greater magnitude than are usually observed on spacecraft in low-Earth orbit. Flight through the geomagnetic field also causes magnetic induction charging of ISS conducting structure. Charging processes resulting from interaction of ISS with auroral electrons may also contribute to charging albeit rarely. The magnitude and frequency of occurrence of possibly hazardous charging events depends on the ISS assembly stage (six more 160V PV arrays will be added to ISS), ISS flight configuration, ISS position (latitude and longitude), and the natural variability in the ionospheric flight environment. At present, ISS is equipped with two plasma contactors designed to control ISS FP to within 40 volts of the ambient F2 plasma. The negative-polarity grounding scheme utilized in the ISS 160V power system leads, naturally, to negative values of ISS FP. A negative ISS structural FP leads to application of electrostatic fields across the dielectrics that separate conducting structure from the ambient F2 plasma, thereby enabling dielectric breakdown and arcing. Degradation of some thermal control coatings and noise in electrical systems can result. Continued review and evaluation of the putative charging hazards, as required by the ISS Program Office, revealed that ISS charging could produce a risk of electric shock to the ISS crew during extra vehicular activity. ISS charging risks are being evaluated in ongoing ISS charging measurements and analysis campaigns. The results of ISS charging measurements are combined with a recently developed detailed model of the ISS charging process and an extensive analysis of historical ionospheric variability data, to assess ISS charging risks using Probabilistic Risk Assessment (PRA) methods. The PRA analysis (estimated frequency of occurrence and severity of the charging hazards) are then used to select the hazard control strategy that provides the best overall safety and mission success environment for ISS and the ISS crew. This paper presents: 1) a summary of ISS spacecraft charging analysis, measurements, observations made to date, 2) plans for future ISS spacecraft charging measurement campaigns, and 3) a detailed discussion of the PRA strategy used to assess ISS spacecraft charging risks and select charging hazard control strategies

Koontz, Steve↗

Resistively Graded Insulation System for Next-Generation Converter-Fed Motors

The objective of this project was to demonstrate the feasibility of a new insulation material system capable of withstanding 10 kV/μs switching voltage ramp rate (dV/dt) with operating frequencies and temperatures targeted at converter-fed motors. If successful, with additional development, this insulation material can enable 5%-10% electric machine energy savings from advanced silicon carbide (SiC) drive implementation. To accomplish these goals, we propose to eliminate partial discharge as a degradation mechanism in high voltage, taped insulation. This can be accomplished through the use of a two-sided coating on a polymer film system that will envelop any residual defects on all sides, effectively creating a Faraday cage around the defect. This project focused on demonstrating the proof of concept for the coating. It was shown that concept of providing a stress grading coating around voids can prevent partial discharge. Simulation and lab scale experiments showed that the design can be implemented in a practical layered structure without causing overheating of the insulation due to conduction. Short term testing and calculations show there is a reasonable likelihood to improved insulation life. A path to full scale production was demonstrated, with gaps in process optimization identified as needing to be closed for full scale implementation. Longer term testing and integration onto a conductor is required to fully quantify life and show benefits at an application level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the effects of neutron irradiation on first-generation corrosion mitigation coatings on SiC for accident-tolerant fuel cladding

In this work, high purity SiC and SiC/SiC composites coated with commercial TiN, Cr, CrN, or CrN/Cr multilayer coatings were irradiated in Ar or flowing PWR water in the Massachusetts Institute of Technology Nuclear Reactor Laboratory (MITR). Irradiation in Ar was performed in the core. In the water environment, identical samples were placed in one of three different locations: in-core, providing exposure to neutron damage and radiolysis-affected water; above-core, where samples were exposed to radiolysis-affected water but not neutron damage, or outside of the core, where samples were exposed to the coolant water without the effects of radiation. Radiation in Ar revealed significant cracking of all but the TiN coatings, attributed to differential swelling between the coating and substrate. Lattice swelling was not observed in any of the coatings, but 0.2% void swelling was observed in the Cr coating. All of the coatings failed during water exposures in the core. Likewise, CrN/Cr spalled in each condition. Cr was protective, except under radiation damage as a result of cracking, and TiN severely degraded in the core with no coating was found following exposure. A SiC/coating ATF cladding system is anticipated to perform adequately following improvements in coating ductility and purity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Acoustic emission evaluation of plasma-sprayed thermal barrier coatings

Acoustic emission techniques have recently been used in a number of studies to investigate the performance and failure behavior of plasma-sprayed thermal barrier coatings. Failure of the coating is a complex phenomena, especially when the composite nature of the coating is considered in the light of possible failure mechanisms. Thus it can be expected that both the metal and ceramic components (i.e., the bond coat and ceramic overlay) of a composite thermal protection system influence the macroscopic behavior and performance of the coating. The aim of the present work is to summarize the 'state-of-the-art' in terms of this initial work and indicate where future progress may be made.

Berndt, C. C.↗

NASA's Orbital Debris Optical Program: ES-MCAT Updated and Upgraded

The 1.3m ES-MCAT telescope (or MCAT for short) now has a proven capability for observing objects from Low- Earth Orbit (LEO) out to Geosynchronous (GEO) orbit, and the ability to run all systems autonomously. A GEO survey, the initial focus for MCAT, will commence in late 2019 to map out the current state of the GEO population as input for the ORbital Debris Engineering Model (ORDEM 4.x). This survey will statistically sample the GEO belt (0 to ~15 deg orbital inclinations) to detect both known and unknown targets. If a break-up occurs, additional surveys of the break-up field can be followed for discovery and investigations of daughter debris fragments from the parent satellite. Discovery can be accomplished by tracking orbits near to and including the parent object’s orbit. Targeted observations of debris can be taken with a suite of broadband filters for characterizing individual objects by ratetracking their known or calculated orbital elements (Two-Line Element sets, TLEs). Several modifications and upgrades have been made to the instrumentation and systems originally installed in 2015 and are reported here. In 2018, MCAT’s primary mirror was recoated with a high-end protected, enhanced silver by the ZeCoat Corporation. The CCD chip was replaced in the Spectral Instruments camera with a broad-band antireflective coated chip. The automated weather systems have been modified from the original system, removing some weather sensors and installing replacements that are better suited to Ascension’s weather and environment. A new 2.5-m ObservaDome replaced the Astrohaven dome on the nearby tower platform that will house an auxiliary 0.4-meter telescope. Finally, in 2019, the Observatory Control System was upgraded to 2.0 which includes additional flexibility for automating data collection and reduction. With these updates completed, MCAT is now well on track to reach Full Operational Capability (FOC) in 2019 for its survey, rate-track, and TLE tracking capabilities.

Lederer, S. M.↗

Performance Assessment of a Photonic Radiative Cooling System for Office Buildings

Spectrally selective materials show high technical potential for use as radiative cooling heat exchangers for buildings. Recent work by Stanford University has applied a photonic approach to tailor the optical properties of a coating material. In a prototype test, a radiative cooler based on that photonic material has demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. This paper presents the simulation and parametric analysis of photonic radiative cooling system that integrates the use of the photonic radiative cooler and radiant floor cooling via the whole energy simulation program EnergyPlus. The simulation was made for a medium office building with three floors and a total floor area of 5,000 m2. Three key design parameters including the storage tank size, the radiator area, and the number of floors are expected to have a large impact on system performance were investigated in this paper. The results show that the percentage of cooling electricity savings from the photonic radiative cooling system relative to a reference variable-air-volume system has a linear relationship with the radiator area, and a quadratic correlation with both tank size and the number of floors. The findings from this parametric analysis are valuable to understand how component sizing affects system performance.

Wang, Weimin↗

Computation Modeling and Assessment of Nanocoatings for Ultra Supercritical Boilers (Final Report)

Forced outages and boiler unavailability of coal-fired fossil plants is most often caused by fire-side corrosion of boiler waterwalls and tubing. Reliable coatings are required for Ultrasupercritical (USC) application to mitigate corrosion since these boilers will operate at a much higher temperatures and pressures than in supercritical (565° C @ 24 MPa) boilers. Computational modeling efforts have been undertaken to design and assess potential Fe-Cr-Ni-Al systems to produce stable nanocrystalline coatings that form a protective, continuous scale of either Al 2 O 3 or Cr 2 O 3 . The computational modeling results identified a new series of Fe-25Cr-40Ni with or without 10 wt.% Al nanocrystalline coatings that maintain long-term stability by forming a diffusion barrier layer at the coating/substrate interface. The computational modeling predictions of microstructure, formation of continuous Al 2 O 3 scale, inward Al diffusion, grain growth, and sintering behavior were validated with experimental results. Advanced coatings, such as MCrAl (where M is Fe, Ni, or Co) nanocrystalline coatings, have been processed using different magnetron sputtering deposition techniques. Several coating trials were performed and among the processing methods evaluated, the DC pulsed magnetron sputtering technique produced the best quality coating with a minimum number of shallow defects and the results of multiple deposition trials showed that the process is repeatable. The cyclic oxidation test results revealed that the nanocrystalline coatings offer better oxidation resistance, in terms of weight loss, localized oxidation, and formation of mixed oxides in the Al 2 O 3 scale, than widely used MCrAlY coatings. However, the ultra-fine grain structure in these coatings, consistent with the computational model predictions, resulted in accelerated Al diffusion from the coating into the substrate. An effective diffusion barrier interlayer coating was developed to prevent inward Al diffusion. The fire-side corrosion test results showed that the nanocrystalline coatings with a minimum number of defects have a great potential in providing corrosion protection. The coating tested in the most aggressive environment showed no evidence of coating spallation and/or corrosion attack after 1050 hours exposure. In contrast, evidence of coating spallation in isolated areas and corrosion attack of the base metal in the spalled areas were observed after 500 hours. These contrasting results after 500 and 1050 hours exposure suggest that the premature coating spallation in isolated areas may be related to the variation of defects in the coating between the samples. It is suspected that the cauliflower-type defects in the coating were presumably responsible for coating spallation in isolated areas. Thus, a defect free good quality coating is the key for the long-term durability of nanocrystalline coatings in corrosive environments. Thus, additional process optimization work is required to produce defect-free coatings prior to development of a coating application method for production parts.

01 COAL, LIGNITE, AND PEAT↗

Preliminary experimental results for a cryogenic brush seal configuration

Preliminary fluid nitrogen flow data are reported for a five-brush, ceramic-coated-rub-runner brush seal system, where the brushes and the rub runner were placed at each end of a centrally pressurized multifunction tester ('back-to-back' set of brushes) and tested at rotor speeds of 0, 10, 18, and 22.5 krpm. After testing, both the brushes and the ceramic-coated rub runner appeared pristine. The coating withstood both the thermomechanical and dynamic loadings with minor wear track scarring. The bristle tips showed some indication of material shearing (smearing) wear. The Ergun porous flow equation was applied to the brush seal data. The Ergun relation, which required heuristic information to characterize the coefficients, fit the gaseous data but was in poor agreement with the fluid results. The brush seal exit conditions were two phase. Two-phase, choked-flow design charts were applied but required one data point at each rotor speed to define the (C(sub f)A x Constant) flow and area coefficients. Reasonable agreement between prediction and data was found, as expected, but such methods are not to be construed as two-phase-flow brush seal analyses.

Carlile, J. A.↗

Preliminary experimental results for a cryogenic brush seal configuration

Preliminary fluid nitrogen flow data are reported for a five-brush, ceramic-coated-rub-runner brush seal system, where the brushes and the rub runner were placed at each end of a centrally pressurized multifunction tester ('back-to-back' set of brushes) and tested at rotor speeds of 0, 10, 18, and 22.5 krpm. After testing, both the brushes and the ceramic-coated rub runner appeared pristine. The coating withstood both the thermomechanical and dynamic loadings with minor wear track scarring. The bristle tips showed some indication of material shearing (smearing) wear. The Ergun (1952) porous flow equation was applied to the brush seal data. The Ergun relation fit the gaseous data but was in poor agreement with the fluid results. The brush seal exit conditions were two phase. Two-phase, choked-flow design charts were applied but required one data point at each rotor speed to define the flow and area coefficients. Reasonable agreement between prediction and data was found, but such methods are not to be construed as two-phase-flow brush seal analyses.

Carlile, J. A.↗

Machine Protection System for the Stepper Motor Actuated SyLMAND Mirrors

SyLMAND, the Synchrotron Laboratory for Micro and Nano Devices at the Canadian Light Source, consists of a dedicated X-ray lithography beamline on a bend magnet port, and process support laboratories in a clean room environment. The beamline includes a double mirror system with flat, chromium-coated silicon mirrors operated at varying grazing angles of incidence (4 mrad to 45 mrad) for spectral adjustment by high energy cut-off. Each mirror can be independently moved by two stepper motors to precisely control the pitch and vertical position. We present in this paper the machine protection system implemented in the double mirror system to allow for safe operation of the two mirrors and to avoid consequences of potential stepper motor malfunction.

43 PARTICLE ACCELERATORS↗

Polarization sensitivity analysis of an earth remote sensing instrument - The MODIS-N phase B study

Polarization analysis software that employs Jones matrix formalism to calculate the polarization sensitivity of an instrument design was developed at Hughes Danbury Optical Systems. The code is capable of analyzing the full ray bundle at its angles of incidence for each optical surface. Input is based on the system ray trace and the thin film coating design at each surface. The MODIS-N (Moderate Resolution Imaging Spectrometer) system is used to demonstrate that it is possible to meet stringent requirements on polarization insensitivity associated with planned remote sensing instruments. Analysis indicates that a polarization sensitivity less than or equal to 2 percent was achieved in all desired spectral bands at all pointing angles, per specification. Polarization sensitivities were as high as 10 percent in similar remote sensing instruments.

Waluschka, E.↗

Development of Nanocomposite Coatings for Future Large-Scale Time Projection Chambers

In the context of this award we tested the performance of thin high-resistivity coatings for their potential usage as field shaping systems in future large scale xenon Time Projection Chambers (TPC). A successful implementation of such thin coatings would likely simplify the design of potential future detectors, allowing to overcome some of the challenges observed with traditional systems constituted by massive discrete electrodes. We studied a wide range of materials and characterized their optical and electrical performances as functions of temperature and wavelength. The measurement campaign indicated that uniform coatings covering the full PTFE substrate (usually used as reflector in LXe TPCs) impact too severely on the light collection performance of such detectors when used with deep UV light. Despite tuning the composition and thicknesses of nanocomposite coatings, we were not able to identify a single coating, properly working at LXe temperature, that would simultaneously fulfill the resistance and optical requirements. Following the risk mitigation strategy identified in the proposal we moved the focus of the R&D to identify proper materials that, when coated with grid-like patterns on PTFE, would not alter meaningfully its optical properties (with respect to bare PTFE panels) but would still serve as effective field shaping systems, properly containing the drift field in TPC detectors. Among the various materials we identified germanium as the most promising one, providing a good adhesion to PTFE and the proper range of sheet resistivity. The Ge-patterned coating tested within a small scale LXe TPC showed good performance as a field shape system and, as desired, did not reduce the detector light yield. These results are encouraging and such technology should further be investigated as a potential alternative to more traditional field shaping electrodes. Incidentally, in the context of this R&D, we stumbled upon an unexpected behavior suggesting that some of the treatments performed on the PTFE panels, in preparation of the coatings, meaningfully boosted the PTFE reflectivity. The most probable candidate is the O2 plasma cleaning procedure. This hypothesis will be tested in the near future by operating the small scale TPC at UChicago first with regular PTFE panels and then with panels bombarded with O2 plasma (but no coatings). This finding, if confirmed, might open up the possibility of further boosting UV light collection in future large detectors by performing such a treatment on the PTFE surfaces.

36 MATERIALS SCIENCE↗

Some Physical Properties of the New Intermetallic Compound NbCd{sub 2}

Solid solutions of cadmium in niobium and NbCd{sub 2} phase are formed by magnetron sputtering and coprecipitation on substrates moving relative to the flow of Nb and Cd particles. The NbCd{sub 2} phase can be described by a tetragonal unit cell with the parameters a = 0.84357 nm, c = 0.54514 nm, and c/a = 0.6426. A very high hole concentration in NbCd{sub 2} is established by studying the coating absorption and transmission spectra corresponding to the intermetallic-compound composition near the fundamental absorption edge, determining the band gap, and measuring the carrier mobility. Such a concentration is characteristic of a strongly degenerate semiconductor or metal. The band gap is determined to be 1.26 eV. The variation in the concentration of carriers and their mobility depending on the cadmium concentration in coatings of the Nb–Cd system confirms the occurrence of the NbCd{sub 2} phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metal Whiskers: Failure Modes and Mitigation Strategies

Metal coatings especially tin, zinc and cadmium are unpredictably susceptible to the formation of electrically conductive, crystalline filaments referred to as metal whiskers. The use of such coatings in and around electrical systems presents a risk of electrical shorting. Examples of metal whisker formation are shown with emphasis on optical inspection techniques to improve probability of detection. The failure modes (i.e., electrical shorting behavior) associated with metal whiskers are described. Based on an almost 9- year long study, the benefits of polyurethane conformal coat (namely, Arathane 5750) to protect electrical conductors from whisker-induced short circuit anomalies is discussed.

Brusse, Jay A.↗

First Results From Nb3Sn Coatings of 2.6 GHz Nb SRF Cavities Using DC Cylindrical Magnetron Sputtering System

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950 °C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb- Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 μm thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of 3.2 × 108 at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to 1.1 × 109, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of 17.9 – 18 K. Here we present the commissioning experience, s ystem optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarization aberrations in the solar activity measurements experiments (SAMEX) solar vector magnetograph

An optical design and polarization analysis of the Air Force/NASA Solar Activity Measurements Experiments solar vector magnetograph optical system is performed. Polarization aberration theory demonstrates that conventional telescope coating designs introduce unacceptably high levels of polarization aberrations into the optical system. Several ultralow polarization mirror and lens coatings designs for this instrument are discussed. Balancing of polarization aberrations at different surfaces is demonstrated.

Mcguire, James P., Jr.↗

High performance discharges in the Lithium Tokamak eXperiment with liquid lithium walls

The first-ever successful operation of a tokamak with a large area (40% of the total plasma surface area) liquid lithium wall has been achieved in the Lithium Tokamak eXperiment (LTX). These results were obtained with a new, electron beam-based lithium evaporation system, which can deposit a lithium coating on the limiting wall of LTX in a five-minute period. Preliminary analyses of diamagnetic and other data for discharges operated with a liquid lithium wall indicate that confinement times increased by 10× compared to discharges with helium-dispersed solid lithium coatings. Ohmic energy confinement times with fresh lithium walls, solid and liquid, exceed several relevant empirical scaling expressions. Spectroscopic analysis of the discharges indicates that oxygen levels in the discharges limited on liquid lithium walls were significantly reduced compared to discharges limited on solid lithium walls. Tokamak operations with a full liquid lithium wall (85% of the total plasma surface area) have recently started.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗