Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Reevaluation of Three Cold War-Era Buildings at Technical Area 22

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (Field Office) reevaluated three magazines (buildings 7, 8, and 10) at Technical Area (TA) 22, Los Alamos National Laboratory (LANL or the Laboratory) (Map 1). This reevaluation was conducted because the magazines have been identified as candidates for preservation due to their association with the almost 40 years of Cold War-era detonator research conducted at adjacent building TA-22-1 (Maps 2–4), a property that is eligible for inclusion in the Manhattan Project National Historical Park (MAPR) for its role in the assembly of the wartime Fat Man bomb. Cold War-era magazines, TA-22-7, -8, and -10, were originally determined not eligible for listing in the National Register of Historic Places (Register) in DX Division’s Facility Strategic Plan: Consolidation and Revitalization at Technical Areas 6, 8, 9, 14, 15, 22, 36, 39, 40, 60, and 69 (McGehee et al. 2005) in consultation with the State Historic Preservation Officer on April 18, 2006. Many of the magazines at TA-22 are of identical construction, and at the time of the initial evaluation, other magazines were selected as the best examples of type for the purpose of architectural documentation. The reevaluation is being conducted because the status of TA-22-1 and its immediate area have changed since the MAPR was authorized in December 2014. The three magazines, along with a magazine that was previously determined eligible in 2006 (TA-22- 9), are within one of the proposed boundaries for the MAPR at LANL and are also now considered candidates for preservation. These magazines were constructed in 1949 to support detonator research, development, and testing, and have served as reinforced storage facilities for high explosives since their construction.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Life cycle cost analysis comparing redesigned CCHP to existing heat pump systems for cities in cold climates

This report indicates that the project progress has met the Go criterion, i.e. demonstrating favorable results of life cycle cost assessment for the redesigned CCHPs. Considering the market price of a baseline heat pump, and required improvements in heat exchangers, fans and an electronic expansion valve of the CCHPs, we estimated that the CCHP using a 3-stage scroll compressor will incur with a cost increment of $\$386$ per rated cooling tonnage, and the CCHP using tandem compressors will increase by $\$770$. Based on the energy savings of the CCHPs, simulated by EnergyPlus, the two CCHPs achieve payback periods less than 4 years among all the cold climate cities. Within a typical heat pump life cycle of 20 years, the CCHPs can achieve cost savings around $\$2000$ per rated cooling tonnage, and the savings are even higher for the extremely cold cities like Duluth and Fairbanks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of the ThermoLift Natural Gas Fired Air Conditioner and Cold-Climate Heat Pump

ThermoLift is currently developing its Thermal Compression Heat Pump (TCHP™), a natural-gas driven air conditioner and cold-climate heat pump, which can provide space heating, water heating, and air conditioning simultaneously in a single device. The system has broad application as a combined heating, ventilation, and air-conditioning (HVAC) solution with the benefit of substantial energy, cost, and greenhouse gas (GHG) reductions. Unlike traditional vapor compression heat-pumps, the TCHP™ uses helium as a working fluid in place of high global warming potential (GWP) refrigerants. The development effort has produced three iterations or generations of prototypes with advancement of the technology readiness level (TRL) from TRL-1 (TCHP™ Gen 1.0) to TRL-5 (TCHP™ Gen 3.0). In August of 2013, the US DOE solicited the submission of proposals through funding opportunity announcement DE-FOA-0000823, Building Technologies Innovations Program. The Office of Energy Efficiency and Renewable Energy (EERE) subsequently accepted ThermoLift’s proposal to develop a heat pump system based on the Hofbauer cycle, a new cycle that supplants the Vuilleumier cycle and provided funding for prototype evaluation at Oak Ridge National Laboratory (ORNL). ORNL is a widely known research center for developing and evaluating building technologies. Through its Building Technologies Research and Integration Center, ORNL has unique capabilities which allows them to collaborate with industry and academia to advance building component technologies. The TCHP™ Gen 3.0 prototype was shipped to ORNL on July 23, 2018. After installation and integration of the heat pump into ORNL’s test facility and performing instrumentation validation and calibration, extended operation of the heat pump was achieved during continuous operation on August 6, 2018, and includes various heating and cooling temperature ranges and performance analysis. The Gen 3.0 prototype was evaluated at four “ambient” temperatures: −25°C, −8.33°C, 8.33°C, and 20°C, (−13°F, 17°F, 47°F, and 68°F) denoted as test points 1-4, respectively. For heating, cycle coefficients of performance (COP) at the four “ambient” temperatures were found to be 1.30, 1.46, 1.52, and 1.61, respectively. Furthermore, there is no capacity reduction as the inlet temperature to the cold heat exchanger (HX) decreases. The heating capacity delivered by the TCHP was found to be 12 kW at -25°C. Finally, this final report identifies measures for obtaining further efficiency improvements.

42 ENGINEERING↗

EMPIRE-PIC Code Verification of a Cold Diode

This report presents the code verification of EMPIRE-PIC to the analytic solution to a cold diode which was first derived by Jaffe. The cold diode was simulated using EMPIRE-PIC and the error norms were computed based on the Jaffe solution. The diode geometry is one-dimensional and uses the EMPIRE electrostatic field solver. After a transient start-up phase as the electrons first cross the anode-cathode gap, the simulations reach an equilibrium where the electric potential and electric field are approximately steady. The expected spatial order of convergence for potential, electric field and particle velocity are observed.

42 ENGINEERING↗

Cold Sintered Ceramics and Cements for Part Encapsulation

In this project, ceramic encapsulation materials were studied for high temperature (>~°500 C) applications where typical polymer encapsulants are unstable. A new low temperature (<~°200 C) method of processing ceramics, the cold sintering process was examined. Additionally, commercially available high temperature ceramic cements were investigated. In both cases, the mechanical strengths of available materials are less than desired (i.e., desired strengths similar to Si 3 N 4 ), limiting applicability. Composite designs to increase mechanical strength are suggested. Additionally, non-uniformities in stresses and densification while embedding alumina sheets in encapsulants via cold sintering using uni-axial pressing led to fracture of sheets, and an alternative iso-static based approach is recommended for future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of the MST-16 crimp process on cold 304L stainless steel

The purpose of this report is to assess the quality of the MST-16 crimp process through a series of cold experiments and metallographic analyses. Common practice in MST-16 uses a mechanical crimp on 304L stainless steel tubes to prevent radioactive contamination from escaping the tube interior for a variety of experiments. The crimped tubes must pass a leak check to demonstrate their radiological safety. Cold (i.e. non-radioactive samples) 304L tube samples were tested using two different approved crimping devices to assess the quality of the crimps. Each crimp was leak checked, followed by destructive metallographic analysis to determine the quality of both the crimp equipment and procedures used by MST-16 personnel.

42 ENGINEERING↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 10 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4-15.201- 2.1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strategies and Approaches for Developing Hands-On Training for Cold Climate Heat Pumps

The International Center for Appropriate and Sustainable Technology (ICAST) is in the process of implementing a program funded by the US Department of Energy (DOE) in which they are providing cold climate heat pump (CCHP) curriculum and training to HVAC workers, ranging from entry to experienced levels. They have coordinated with Santa Fe Community College (SFCC) to develop online curricula, and through their involvement with the DOE Better Buildings Workforce Accelerator, they requested technical assistance from the National Renewable Energy Laboratory (NREL) to help them develop programs that incorporate hands-on and on-the-job skills training and job placement services in coordination with local employers. This report offers a step-by step-overview of the process for developing a new workforce development and hands-on training program in a new region, outlining practices to help understand the market, and to effectively recruit, train, and connect people to HVAC jobs installing cold climate heat pumps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Heat Pump Evaluation

The use of heat pumps in cold and very cold climates increased by 63% between 2009 and 2015 [1, 2]. This can be attributed to development of heat pumps with higher heating capacity at lower temperatures and increased efficiency. A primary technology driving this trend is the use of variable-speed compressors, which come with an increase in the level of controls in the equipment. Most units with variable-speed compressors also include electronic expansion valves and variable-speed indoor (ID) and outdoor (OD) fans. With the increased complexity of these systems, developing a test procedure that is representative of typical performance and not too burdensome on manufacturers presents a difficult challenge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preheating of Cold, High Moisture Particulate Biomaterials to Reduce Drying Time

Forest Concepts led a two-year project to reduce fossil fuel consumption and improve the energy efficiency of dryers through the application of radio frequency (RF) energy impartation to preheat cold-wet bulk particulate biomass materials. A comprehensive biomass heating and drying mathematical model was developed that enables simulation of drying systems for biomass as well as most other bulk porous particulate materials. Experimental and modeling results conclude that energy consumption for both RF preheating and hot-air preheating are essentially equal for cold, high-moisture feedstocks that are above fiber saturation and therefore not economically beneficial for those conditions. Further results suggest that RF heating may have a direct energy consumption benefit in the late stages of drying and in case of preheating biomass that has a moisture content below fiber saturation. This work was funded in part by the US Department of Energy under contact DE-EE0009130.

09 BIOMASS FUELS↗

Electromagnetic Waves in Cold Plasmas

A collisionless fluid model of a plasma is presented and solved to first order in the cold, high frequency limit. From this model, a homogeneous system of linear equations is obtained for a harmonic electric field perturbation from which the Appleton-Hartree equation is derived. Moreover, the polarization states of electromagnetic waves in cold, collisionless plasmas are examined. Complete sets of equations governing the reflection and transmission of electromagnetic waves in both non magnetized and magnetized plasmas are obtained. In solving the boundary problem, the Booker quartic is derived and the nature of its roots discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAGNETIC FLUX EXPULSION IN SUPERCONDUCTING RADIO-FREQUENCY NIOBIUM CAVITIES MADE FROM COLD WORKED NIOBIUM

Trapped residual magnetic field during the cool down of superconducting radio frequency (SRF) cavities is one of the primary sources of RF residual losses leading to lower quality factor. Historically, SRF cavities have been fabricated from high purity fine grain niobium with grain size ~50 to 100 µm as well as large grain with grain size of the order of few centimeters. Non-uniform recrystallization of fine-grain Nb cavities after the post fabrication heat treatment leads to higher flux trapping during the cool down, and hence the lower quality factor. We fabricated two 1.3 GHz single cell cavities from cold-worked niobium from different vendors and processed along with cavities made from SRF grade Nb. The flux expulsion and flux trapping sensitivity were measured after successive heat treatments in the range 800 to 1000°C. The flux expulsion from cold-worked fine-grain Nb cavities improves after 800°C/3h heat treatments and it becomes similar to that of standard fine-grain Nb cavities when the heat treatment temperature is higher than 900°C.

Khanal, B. D.↗

Machine Learning Enabled Atomistic Study of the Micro-Cold Spray Process [Poster]

Micro-cold spray is typically conducted by impacting 200-2000 nm particles at velocities of ~500 m/s. Molecular dynamics simulations have been used to study micro cold spray, but the particles that can be simulated using conventional potentials are much smaller than those used experimentally. The viewgraphs taken from molecular dynamics simulations and shown below are cross-sections of a 50 nm Ta particle with a 3 nm oxide layer impacting at 500 m/s using a machine learning enabled DeePMD potential. Using more expensive reactive interatomic potentials, the previous largest particle size for a metal/oxide impact simulation was 12 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monitoring the corrosion resistance of cold-spray coatings with membrane-based sensors

In this presentation, the MBES shows the ability to detect the change in exposed environment even with cold-spray coatings. Corrosion rates from the cold-spray coating were comparable to a 316 stainless steel sample. Defects in the coating did not impact sensor performance in terms of corrosion rate or water content detection. Energy dispersive X-ray spectroscopy was used to document ion migration into the membrane.

Rendon, Arnaldo↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Plasma IC Report

This past year we completed the simulation campaign in support of our magnetospheric cold plasma research project. This project aimed to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere.

58 GEOSCIENCES↗

Cold Spray Field Deployment Evaluation for Double-Shell Tank 241-AN-105

This report highlights the documentation that supported Cold Spray field deployment in double-shell tank (DST) 241-AN-105 (AN-105) in July of 2025. This work was a collaborative effort between VRC Metal Systems (VRC), Robotic Technologies of Tennessee (RTT), the Hanford Tank Waste Operation and Closure (H2C) Chief Technology Office, H2C Tank Farm Projects Engineering, H2C Tank and Pipeline Integrity (TAPI) and H2C Ultrasonic Testing (UT) Operations & Support. Since 2019, the Chief Technology Office has been developing Cold Spray technology for refurbishing Hanford’s DSTs (RPP-RPT-65015). This technology is particularly relevant for addressing localized corrosion within the annulus of the DSTs by propelling metal powder particles at supersonic speeds to targeted areas. This process results in high-quality coatings characterized by high bond strength and low porosity result.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

99 GENERAL AND MISCELLANEOUS↗