Search NASA⌕ Search

SEARCH · Search NASA

Results for “conditionally specified models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Human Perceptions of Colour Rendition at Different Chromaticities

An experiment was conducted to evaluate how subjective impressions of a light source’s color quality depend upon color rendition and chromaticity. Thirty-three participants each evaluated 50 lighting scenes in a 3.7 m by 5.5 m room filled with objects selected to cover a range of hue, saturation, and lightness. The lighting scenes included five chromaticity groups, specified here using correlated color temperature (CCT) and Duv¬: 2700 K, 0.000; 2700 K, -0.007; 3500 K, 0.000; 4300 K, 0.000; 4300 K, -0.007. Within each group were the same 10 systematically-varied color rendition conditions. The Illuminating Engineering Society (IES) TM-30-15 Fidelity Index (Rf) values ranged from 60 to 93, IES TM-30 Gamut Index (Rg) values from 88 to 124, and IES TM-30 Hue Angle Bin 1 Chroma Shift (Rcs,h1) values from -15% to 28%. All lighting scenes had the same nominal illuminance. Participants were asked to rate each scene on eight point scales for saturated-dull, normal-shifted, and like-dislike, as well as choosing whether they found the scenes to be acceptable or unacceptable. The findings suggest that color rendition preferences can vary with chromaticity, but do not support absolute preferences for negative Duv values. At 4300 K, there was no difference in rated preference, saturation, normalness, or acceptability between the two groups with different Duv values. However, at 2700 K, there was a significant difference for all four perceptions, with the negative Duv sources being rated more liked (on average)—and for nine of the ten individual color rendition conditions. Further, across all levels of red chroma shift—according to TM-30 values Rcs,h1, Rcs,h15, and Rcs,h16—the room was rated as more saturated at 2700 K than at 3500 K or 4300 K (regardless of Duv); in turn, increases in red saturation were less preferred and less acceptable at 2700 K than the other CCTs. The differences in ratings between the chromaticity groups were substantially smaller than the range in ratings for the 10 color rendition conditions in each group, and on average the best fit model uses a combination of Rf, Rcs,h16, and potentially Rg. Despite the differences in ratings for chromaticity groups, a set of criteria identified in previous research for preferred color rendition in this generic application could be used for all groups. Those criteria are Rf = 74, -1% = Rcs,h1 = 15%, and Rg = 100.

Royer, Michael P.↗

A Methodology for defining intermediate level waste package characteristics that ensure criticality safety in a geological disposal facility - 14599

Radioactive Waste Management (RWM) is responsible for implementing geological disposal of the UK's higher activity radioactive wastes. These wastes include fissile nuclides and, therefore, demonstration of the criticality safety of the wastes under disposal conditions forms an important component of RWM's disposal system safety case. The basis for ensuring criticality safety of intermediate level waste (ILW) packages is to specify controls on the fissile material content of individual packages through the application of deterministic criticality safety assessments (CSAs). The approach is defined and controlled through RWM's Disposability Assessment process, which aims to ensure that: criticality is prevented during waste package transport to a GDF; the risk of criticality is tolerable and as low as reasonably practicable (ALARP) during GDF operations; and the likelihood and consequences of criticality arising from the evolution of waste packages after GDF closure are low. The most restrictive phase determines the package fissile material limit and, until now, in many cases the GDF post-closure phase has provided the most restrictive limit. Currently, the GDF post-closure limits are derived deterministically using highly stylised and conservative assumptions about fissile material accumulations occurring on very long timescales into the future. RWM, waste producers and regulators do not currently consider this approach to be yielding an appropriate balance of risk. Therefore, RWM is modifying the process for setting fissile material limits on ILW packages by making use of the outcomes of its recent research projects to establish the likelihood of post-closure criticality in a GDF and the consequences of hypothetical post-closure criticality events (presented in companion papers). This paper presents the revised methodology, which is based on the requirement that criticality in a GDF can be demonstrated to be of low and tolerable consequences with regard the performance of a GDF. A probabilistic 'low-likelihood package envelope' is proposed that establishes the packaging and disposal facility conditions under which post-closure criticality is considered to be of low likelihood and low consequence. The bounding conditions for establishing the extent of the package envelope have been evaluated through application of the methodologies and models developed in RWM's Likelihood of Criticality research project. It is expected that the vast majority of ILW packages would meet the package envelope requirements. The methodology also allows the use of other options, such as deterministic CSAs, for waste packages that fall outside the low-likelihood package envelope. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local Radiation Shielding Design Methodology

The NSLS-II accelerators are housed within a radiation enclosure of normal concrete (and in some places high density concrete) that has been designed to reduce the radiation generated from an assumed operational beam loss or bulk shielding current (BCS) from each accelerator. The beam loss model used to estimate the thickness of this bulk shielding, assumed a beam energy at the expected operating energy and a current loss based on reasonable assumptions for the fraction of the expected operating current. The thickness of the shield was determined to be the amount required to reduce the radiation outside the shield to a maximum dose rate of <0.5mrem/hr. for occupied areas for these normal operational losses. These assumed beam losses and the bulk shielding thicknesses required are given in reference [1]. Abnormal operating conditions generating higher than normal beam losses must also be considered, and additional engineering controls will be required depending on the magnitude of the radiation levels generated during the abnormal condition. Additional local shielding subject to configuration control may be utilized to reduce radiation levels associated with these abnormal loss conditions. Interlocked area radiation monitors are another means to prevent continued operation with higher than an acceptable level. The NSLS-II Shielding Policy requires that an engineered system be utilized to mitigate an abnormal condition producing radiation levels greater than 100 mR/h, and that two systems are required if the projected radiation levels during a fault condition are > 2000 mR/h. It is intended that shielding limits the dose rate to < 0.5 mR/h in occupied areas for normal operational losses, and the combination of administrative and engineered controls for abnormal losses will maintain radiation exposure to trained personnel working at the NSLS-II facility to as low as reasonably achievable. It is anticipated that all individual exposures will be well within the planned administrative control level of 100mrem/year. This technical note presents the method used to identify these potential high beam loss locations, evaluate the potential radiation risk these losses create outside the enclosure shield and the design process that specifies the required local radiation shielding needed to reduce this risk below the maximum dose rate of the bulk shield design, listed above. If shielding can’t be adequately provided or if other fault initiated losses could occur, then the necessary engineering controls will be indicated that will limit the energy, current or duration of the beam transport that constitute this high beam loss risk.

36 MATERIALS SCIENCE↗

New Adsorption Cycles for Carbon Dioxide Capture and Concentration

The objective of this three-year project was to study new pressure swing adsorption (PSA) cycles for CO{sub 2} capture and concentration at high temperature. The heavy reflux (HR) PSA concept and the use of a hydrotalcite like (HTlc) adsorbent that captures CO{sub 2} reversibly at high temperatures simply by changing the pressure were two key features of these new PSA cycles. Through the completion or initiation of nine tasks, a bench-scale experimental and theoretical program has been carried out to complement and extend the process simulation study that was carried out during Phase I (DE-FG26-03NT41799). This final report covers the entire project from August 1, 2005 to July 31, 2008. This program included the study of PSA cycles for CO{sub 2} capture by both rigorous numerical simulation and equilibrium theory analysis. The insight gained from these studies was invaluable toward the applicability of PSA for CO{sub 2} capture, whether done at ambient or high temperature. The rigorous numerical simulation studies showed that it is indeed possible to capture and concentrate CO{sub 2} by PSA. Over a wide range of conditions it was possible to achieve greater than 90% CO{sub 2} purity and/or greater than 90% CO{sub 2} recovery, depending on the particular heavy reflux (HR) PSA cycle under consideration. Three HR PSA cycles were identified as viable candidates for further study experimentally. The equilibrium theory analysis, which represents the upper thermodynamic limit of the performance of PSA process, further validated the use of certain HR PSA cycles for CO{sub 2} capture and concentration. A new graphical approach for complex PSA cycle scheduling was also developed during the course of this program. This new methodology involves a priori specifying the cycle steps, their sequence, and the number of beds, and then following a systematic procedure that requires filling in a 2-D grid based on a few simple rules, some heuristics and some experience. It has been tested successfully against several cycle schedules taken from the literature, including a 2-bed 4-step Skarstrom cycle, a 4-bed 9-step process with 2 equalization steps, a 9-bed 11-step process with 3 equalization steps, and a 6-bed 13-step process with 4 equalization steps and 4 idle steps. With respect to CO{sub 2} capture and concentration by PSA, this new approach is now providing a very straightforward way to determine all the viable 3-bed, 4-bed, 5-bed, n-bed, etc. HR PSA cycle schedules to explore using both simulation and experimentation. This program also touted the use of K-promoted HTlc as a high temperature, reversible adsorbent for CO{sub 2} capture by PSA. This program not only showed how to use this material in HR PSA cycles, but it also proposed a new CO{sub 2} interaction mechanism in conjunction with a non-equilibrium kinetic model that adequately describes the uptake and release of CO{sub 2} in this material, and some preliminary fixed bed adsorption breakthrough and desorption elution experiments were carried out to demonstrate complete reversibility on a larger scale. This information was essentially missing from the literature and deemed invaluable toward promoting the use of K-promoted HTlc as a high temperature, reversible adsorbent for CO{sub 2} capture by PSA. Overall, the objectives of this project were met. It showed the feasibility of using K-promoted hydrotalcite (HTlc) as a high temperature, reversible adsorbent for CO{sub 2} capture by PSA. It discovered some novel HR PSA cycles that might be useful for this purpose. Finally, it revealed a mechanistic understanding of the interaction of CO{sub 2} with K-promoted HTlc.

01 COAL, LIGNITE, AND PEAT↗

TMAP7 User Manual

The TMAP Code was written at the Idaho National Engineering and Environmental Laboratory by Brad Merrill and James Jones in the late 1980s as a tool for safety analysis of systems involving tritium. Since then it was upgraded to TMAP4 and has been used in numerous applications including experiments supporting fusion safety, predictions for advanced systems such as the International Thermonuclear Experimental Reactor (ITER), and estimates involving tritium production technologies. Its further upgrade to TMAP2000 and now to TMAP7 was accomplished in response to several needs. TMAP and TMAP4 had the capacity to deal with only a single trap for diffusing gaseous species in solid structures. TMAP7 includes up to three separate traps and up to 10 diffusing species. The original code had difficulty dealing with heteronuclear molecule formation such as HD and DT under solution-law dependent diffusion boundary conditions. That difficulty has been overcome. TMAP7 automatically generates heteronuclear molecular partial pressures when solubilities and partial pressures of the homonuclear molecular species are provided for law-dependent diffusion boundary conditions. A further sophistication is the addition of non-diffusing surface species. Atoms such as oxygen or nitrogen or formation and decay or combination of hydroxyl radicals on metal surfaces are sometimes important in reactions with diffusing hydrogen isotopes but do not themselves diffuse appreciably in the material. TMAP7 will accommodate up to 30 such surface species, allowing the user to specify relationships between those surface concentrations and partial pressures of gaseous species above the surfaces or to form them dynamically by combining diffusion species or other surface species. Additionally, TMAP7 allows the user to include a surface binding energy and an adsorption barrier energy. The code includes asymmetrical diffusion between the surface sites and regular diffusion sites in the bulk. All of the previously existing features for heat transfer, flows between enclosures, and chemical reactions within the enclosures have been retained, but the allowed problem size and complexity have been increased to take advantage of the greater memory and speed available on modern computers. One additional feature unique to TMAP7 is the addition of radioactive decay for both trapped and mobile species. Whereas earlier versions required a separate FORTRAN compiler to operate, TMAP7 is based on a publiclicense compiler, distributed with the code.

08 HYDROGEN↗

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Report

Many gearboxes in wind turbines have not been achieving their expected design life [1]; they do, however, commonly meet or exceed the design criteria specified in current standards in the gear, bearing, and wind turbine industry as well as third-party certification criteria. The cost of gearbox replacements and rebuilds, as well as the downtime associated with these failures, has elevated the cost of wind energy. In 2006, the U.S. Department of Energy established the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC). Its key goal is to understand the root causes of premature gearbox failures and improve their reliability [2]. The GRC is examining a hypothesis that the gap between design-estimated and actual wind turbine gearbox reliability is caused by underestimation of loads, inaccurate design tools, the absence of critical elements in the design process, or insufficient testing. This test report describes the recent tests of GRC gearbox (GB) 2 in the National Wind Technology Center (NWTC) dynamometer and documents any modifications to the original test plan [3]. In this manner, it serves as a guide for interpreting the publicly released data sets with brief analyses to illustrate the data. Specific objectives of the test were to assess the effect of dynamic nontorque load (NTL) on the planetary section, generator misalignment on the highspeed shaft (HSS), and field representative conditions on the gearbox in general. Detailed analysis of those test objectives will be presented in subsequent publications.

17 WIND ENERGY↗

Adaptive Sampling for In Situ Cloud Probe (Final Report)

Clouds play a leading role in the Earth's global energy and solar radiation balance and hydrological cycle. Improving cloud models requires detailed information on the cloud microphysical properties, such as droplet size distribution and number density, liquid water content and cloud composition (droplets, ice particles), which can only be provided by aerial in situ measurements. However, for many atmospheric measurement instruments, the lack of flexibility in selecting the operational mode during operation can lead to uncertainties in sampling and measurement characteristics under continuously varying atmospheric conditions. This SBIR project is developing an advanced, compact optical imaging technology for in situ characterization of cloud hydrometeors. The development involves a deep modification of the existing Mesa Photonics’ Cloud Droplet Measurement System (CDMS) in order to implement real-time automatic adaptive sampling based on the acquired in situ data and environmental parameters. The new system, CDMS-2, implements two measurement modes: side-scatter imaging for smaller hydrometeors and direct bright-field-illumination imaging for larger hydrometeors in a significantly larger sample volume. The system measures the droplet size distribution (DSD) and number density with an added capability of discriminating between liquid water and ice hydrometeors (based on polarization-resolved side-scatter imaging). The instrument will implement automatic switching or alternating between the regular side-scatter imaging mode and sparse/large hydrometeor mode (based on the acquired data). Other adaptive sampling capabilities include variable sample volume and dynamic range (based on the measured DSD). The preferred deployment platforms are uncrewed aircraft systems (UAS) and tethered balloon/kite systems (TBS). The Phase I project achieved (or exceeded) the goals listed in the Work Plan. A CDMS-2 laboratory prototype implementing the polarization-resolved side-scatter imaging mode and direct bright-field-illumination imaging mode was designed and built. Additional capabilities included the variable illumination pulse energy and sample volume. The smallest detectable droplet diameter was improved to 3–4 μm (from the nominal 10 μm value specified for the original CDMS). Discrimination between water droplets and ice particles was experimentally demonstrated. The Phase I prototype was extensively tested and calibrated in the laboratory and also tested in the Pi Cloud Chamber at Michigan Technological University (MTU). The two intensive experimental campaigns at MTU provided unique opportunities of testing the CDMS-2 laboratory prototype under realistic warm and mixed-phase cloud conditions (stable for long periods of time), testing different sampling modes and intercomparing the CDMS-2 prototype to other co-located cloud characterization instruments. The Phase I project successfully demonstrated the feasibility of the proposed technology and identified the engineering challenges of designing a field deployable prototype instrument in Phase II. The Phase I study provides a solid basis for development, characterization and field-testing of the proposed advanced cloud probe with adaptive sampling in Phase II followed by commercialization of the technology in Phase III.

47 OTHER INSTRUMENTATION↗

Financial Analysis of the High Flow Experiment conducted at the Glen Canyon Dam during Water Year 2023

The Glen Canyon Dam (GCD) is a Colorado River Storage Project (CRSP) power resource that is a component of the Salt Lake City Area Integrated Projects (SLCA/IP). The 2016 record of decision (ROD) for the GCD long-term experimental and management plan (LTEMP) final Environmental Impact Statement (EIS) specified criteria for GCD monthly water releases, daily and hourly operating limits, and experimental releases. This report examines the financial implications of the high flow experiment (HFE) conducted at GCD during the spring of Water Year (WY) 2023 as required by the LTEMP HFE Protocol. This report is part of a series of reports that describe the financial costs of LTEMP experimental releases since the 2016 ROD was adopted in January 2017. Previous reports analyzed the impact of several past HFEs and Bug Flow Experiments. This report focuses on the HFE conducted in April 2023. For this experimental release, financial costs of approximately $1.33 million were incurred because the HFE required sustained water releases exceeding the power plant’s maximum turbine flow rate. In addition, during the experiment, operators were not allowed to shape GCD power production, either to follow Firm Electric Service (FES) customer day-ahead energy deliveries or to respond to market prices. This study identifies the main factors contributing to the HFE costs and examines the interdependencies among these factors. It applies an integrated set of tools to estimate Western Area Power Administration (WAPA) financial impacts by simulating GCD under two types of cases; namely, (1) a “With Experiment” case that mimics the operations that actually occurred and (2) a “Without Experiment” case that simulates operations under the assumption that the HFE did not occur. The “With Experiment” case mimics operations during the HFE and the entire month the HFE occurred. It complies with LTEMP hourly and daily operating criteria. The “Without Experiment” case assumes that the HFE did not occur. The monthly water release volume is assumed to be identical under both cases. The Colorado River Storage Project Python-based model (CRiSPPy) model was the main modeling tool used to simulate the dispatch of the GCD hydropower plant and associated water releases from Lake Powell. In the modeling process, the research team used extensive data sets and historical information on SLCA/IP power plant characteristics, hydrologic conditions, and WAPA’s power purchases and sales prices. In addition to estimating the financial impact of the HFE, the team used the CRiSPPy model to gain insights into the interplay among ROD operating criteria, exceptions made to criteria to accommodate the HFE, and WAPA operating practices.

13 HYDRO ENERGY↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

FY2014 FES (Fusion Energy Sciences) Theory & Simulation Performance Target, Final Report

We report here the work done for the FY14 OFES Theory Performance Target as given below: "Understanding alpha particle confinement in ITER, the world's first burning plasma experiment, is a key priority for the fusion program. In FY 2014, determine linear instability trends and thresholds of energetic particle-driven shear Alfven eigenmodes in ITER for a range of parameters and profiles using a set of complementary simulation models (gyrokinetic, hybrid, and gyrofluid). Carry out initial nonlinear simulations to assess the effects of the unstable modes on energetic particle transport". In the past year (FY14), a systematic study of the alpha-driven Alfven modes in ITER has been carried out jointly by researchers from six institutions involving seven codes including the transport simulation code TRANSP (R. Budny and F. Poli, PPPL), three gyrokinetic codes: GEM (Y. Chen, Univ. of Colorado), GTC (J. McClenaghan, Z. Lin, UCI), and GYRO (E. Bass, R. Waltz, UCSD/GA), the hybrid code M3D-K (G.Y. Fu, PPPL), the gyro-fluid code TAEFL (D. Spong, ORNL), and the linear kinetic stability code NOVA-K (N. Gorelenkov, PPPL). A range of ITER parameters and profiles are specified by TRANSP simulation of a hybrid scenario case and a steady-state scenario case. Based on the specified ITER equilibria linear stability calculations are done to determine the stability boundary of alpha-driven high-n TAEs using the five initial value codes (GEM, GTC, GYRO, M3D-K, and TAEFL) and the kinetic stability code (NOVA-K). Both the effects of alpha particles and beam ions have been considered. Finally, the effects of the unstable modes on energetic particle transport have been explored using GEM and M3D-K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Generalized Fluid System Simulation Program (GFSSP) for Teaching and Performing Senior Design Projects at the Educational Institutions

This paper describes the experience of the authors in using the Generalized Fluid System Simulation Program (GFSSP) in teaching Design of Thermal Systems class at University of Alabama in Huntsville. GFSSP is a finite volume based thermo-fluid system network analysis code, developed at NASA/Marshall Space Flight Center, and is extensively used in NASA, Department of Defense, and aerospace industries for propulsion system design, analysis, and performance evaluation. The educational version of GFSSP is freely available to all US higher education institutions. The main purpose of the paper is to illustrate the utilization of this user-friendly code for the thermal systems design and fluid engineering courses and to encourage the instructors to utilize the code for the class assignments as well as senior design projects. The need for a generalized computer program for thermofluid analysis in a flow network has been felt for a long time in aerospace industries. Designers of thermofluid systems often need to know pressures, temperatures, flow rates, concentrations, and heat transfer rates at different parts of a flow circuit for steady state or transient conditions. Such applications occur in propulsion systems for tank pressurization, internal flow analysis of rocket engine turbopumps, chilldown of cryogenic tanks and transfer lines, and many other applications of gas-liquid systems involving fluid transients and conjugate heat and mass transfer. Computer resource requirements to perform time-dependent, three-dimensional Navier-Stokes computational fluid dynamic (CFD) analysis of such systems are prohibitive and therefore are not practical. Available commercial codes are generally suitable for steady state, single-phase incompressible flow. Because of the proprietary nature of such codes, it is not possible to extend their capability to satisfy the above-mentioned needs. Therefore, the Generalized Fluid System Simulation Program (GFSSP1) has been developed at NASA Marshall Space Flight Center (MSFC) as a general fluid flow system solver capable of handling phase changes, compressibility, mixture thermodynamics and transient operations. It also includes the capability to model external body forces such as gravity and centrifugal effects in a complex flow network. The objectives of GFSSP development are: a) to develop a robust and efficient numerical algorithm to solve a system of equations describing a flow network containing phase changes, mixing, and rotation; and b) to implement the algorithm in a structured, easy-to-use computer program. The analysis of thermofluid dynamics in a complex network requires resolution of the system into fluid nodes and branches, and solid nodes and conductors as shown in Figure 1. Figure 1 shows a schematic and GFSSP flow circuit of a counter-flow heat exchanger. Hot nitrogen gas is flowing through a pipe, colder nitrogen is flowing counter to the hot stream in the annulus pipe and heat transfer occurs through metal tubes. The problem considered is to calculate flowrates and temperature distributions in both streams. GFSSP has a unique data structure, as shown in Figure 2, that allows constructing all possible arrangements of a flow network with no limit on the number of elements. The elements of a flow network are boundary nodes where pressure and temperature are specified, internal nodes where pressure and temperature are calculated, and branches where flowrates are calculated. For conjugate heat transfer problems, there are three additional elements: solid node, ambient node, and conductor. The solid and fluid nodes are connected with solid-fluid conductors. GFSSP solves the conservation equations of mass and energy, and equation of state in internal nodes to calculate pressure, temperature and resident mass. The momentum conservation equation is solved in branches to calculate flowrate. It also solves for energy conservation equations to calculate temperatures of solid nodes. The equations are coupled and nonlinear; therefore, they are solved by an iterative numerical scheme. GFSSP employs a unique numerical scheme known as simultaneous adjustment with successive substitution (SASS), which is a combination of Newton-Raphson and successive substitution methods. The mass and momentum conservation equations and the equation of state are solved by the Newton-Raphson method while the conservation of energy and species are solved by the successive substitution method. GFSSP is linked with two thermodynamic property programs, GASP2 and WASP3 and GASPAK4, that provide thermodynamic and thermophysical properties of selected fluids. Both programs cover a range of pressure and temperature that allows fluid properties to be evaluated for liquid, liquid-vapor (saturation), and vapor region. GASP and WASP provide properties of 12 fluids. GASPAK includes a library of 36 fluids. GFSSP has three major parts. The first part is the graphical user interface (GUI), visual thermofluid analyzer of systems and components (VTASC). VTASC allows users to create a flow circuit by a 'point and click' paradigm. It creates the GFSSP input file after the completion of the model building process. GFSSP's GUI provides the users a platform to build and run their models. It also allows post-processing of results. The network flow circuit is first built using three basic elements: boundary node, internal node, and branch.

Majumdar, A. K.↗

Experiments and Modeling of Proppant Embedment and Fracture Conductivity for the Caney Shale, Oklahoma, USA

ABSTRACT: The ultimate aim of hydraulic fracturing is to have a long and conductive flow path that extends from the wellbore into the formation. The effective fracture length is part of a hydraulically propped fracture which contributes to production. The difficulty in achieving economical production targets from shale reservoirs is at the forefront in many exploration companies. Fracture conductivity loss is related to; proppant embedment under depletion, proppant crushing, damage as a result of fracturing fluid, fines migration and proppant-pack permeability-damage are some of the factors that contribute to production decline after hydraulic fracturing in shale reservoirs. The Caney Shale is a calcareous organic-rich mudrock. Various studies have investigated the effect that clay on shale well productivity, however, there is currently no literature on the Caney shale in relation to horizontal wells; all available literature exists in vertical wells as well as on formations of the Caney that are shallow in comparison to an emerging play which is twice the depth. In this paper we investigate stress-dependent fracture conductivity of proppant-filled fractures and proppant embedment in Caney shale through laboratory and modeling studies. API fracture conductivity tests were conducted using 2% KCl on five locations within the Caney shale that consisted of selecting three brittle(reservoir) zones and two ductile zones. Confining pressures range from 1,000 psi to 12,000 psi at 210°F. Conductivity, permeability as well as embedment were measured during the test. Our experimental results have confirmed that improved fracture conductivity is attributed to; proppant size, the increase in porosity of the proppant pack, closure pressure changes and the reduction in fracture conductivity are a function of many factors such as fracture closure stress. The findings from this study could help the stimulation design by providing new insights into the critical factors that are to be determined to facilitate the choice of proppants as well as fracturing fluids for long term production and recovery from shale reservoirs. 1 INTRODUCTION The development of low permeability formations, like shales, has been aided by hydraulic fracturing of horizontal wells (Radonjic et al., 2020). Hydraulic fracturing fluid is injected at a high pressure to induce tensile fractures that can link to and stimulate natural fractures (Katende et al., 2021a,b). Preserving adequate conductivity in hydraulic fractures over the life of the wells is required for economic production; nevertheless, conserving such conductivity can be difficult in some circumstances, particularly in soft, clay-rich formations (Wang et al., 2021). Proppant particles help to keep the fractures open when the pumping stops and the fracturing fluid returns to the wellbore, producing one or more propped hydraulic fractures of varying length, breadth, and height (Katende et al., 2021a). The proppant pack within the hydraulic fracture boosts well output by providing a greater permeability flowpath for hydrocarbons (Duenckel et al., 2016). Proppant in the fracture is under complicated stress conditions, and the interplay between the rock formation and the proppant pack has a significant impact on proppant-pack permeability (Karazincir et al., 2019). Proppant may be embedded (Katende et al., 2021a) in the rock or crushed into small pieces if the proppant size and strength characteristics are not specified appropriately, resulting in a loss in proppant-pack permeability and fracture aperture, and consequently a fall in well output.

Katende, A.↗

Energy Saving Melting and Revert Reduction Technology (E-SMARRT): Mechanical Performance of Dies

As a net shape process, die casting is intrinsically efficient and improvements in energy efficiency are strongly dependent on design and process improvements that reduce scrap rates so that more of the total consumed energy goes into acceptable, usable castings. A casting that is distorted and fails to meet specified dimensional requirements is typically remelted but this still results in a decrease in process yield, lost productivity, and increased energy consumption. This work focuses on developing, and expanding the use of, computer modeling methods that can be used to improve the dimensional accuracy of die castings and produce die designs and machine/die setups that reduce rejection rates due to dimensional issues. A major factor contributing to the dimensional inaccuracy of the casting is the elastic deformations of the die cavity caused by the thermo mechanical loads the dies are subjected to during normal operation. Although thermal and die cavity filling simulation are widely used in the industry, structural modeling of the die, particularly for managing part distortion, is not yet widely practiced. This may be due in part to the need to have a thorough understanding of the physical phenomenon involved in die distortion and the mathematical theory employed in the numerical models to efficiently model the die distortion phenomenon. Therefore, two of the goals of this work are to assist in efforts to expand the use of structural modeling and related technologies in the die casting industry by 1) providing a detailed modeling guideline and tutorial for those interested in developing the necessary skills and capability and 2) by developing simple meta-models that capture the results and experience gained from several years of die distortion research and can be used to predict key distortion phenomena of relevance to a die caster with a minimum of background and without the need for simulations. These objectives were met. A detailed modeling tutorial was provided to NADCA for distribution to the industry. Power law based meta-models for predicting machine tie bar loading and for predicting maximum parting surface separation were successfully developed and tested against simulation results for a wide range of machines and experimental data. The models proved to be remarkably accurate, certainly well within the requirements for practical application. In addition to making die structural modeling more accessible, the work advanced the state-of-the-art by developing improved modeling of cavity pressure effects, which is typically modeled as a hydrostatic boundary condition, and performing a systematic analysis of the influence of ejector die design variables on die deflection and parting plane separation. This cavity pressure modeling objective met with less than complete success due to the limits of current finite element based fluid structure interaction analysis methods, but an improved representation of the casting/die interface was accomplished using a combination of solid and shell elements in the finite element model. This approximation enabled good prediction of final part distortion verified with a comprehensive evaluation of the dimensions of test castings produced with a design experiment. An extra deliverable of the experimental work was development of high temperature mechanical properties for the A380 die casting alloy. The ejector side design objective was met and the results were incorporated into the metamodels described above. This new technology was predicted to result in an average energy savings of 2.03 trillion BTU's/year over a 10 year period. Current (2011) annual energy saving estimates over a ten year period, based on commercial introduction in 2009, a market penetration of 70% by 2014 is 4.26 trillion BTU's/year by 2019. Along with these energy savings, reduction of scrap and improvement in casting yield will result in a reduction of the environmental emissions associated with the melting and pouring of the metal which will be saved as a result of this technology. The average annual estimate of CO2 reduction per year through 2020 is 0.085 Million Metric Tons of Carbon Equivalent (MM TCE).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD 2030 Grand Challenge: CFD-in-the-Loop Monte Carlo Flight Simulation for Space Vehicle Design

Flight qualification of space vehicles is markedly different from those typically employed for aircraft. The concept of an extensive flight test campaign for a space vehicle does not exist, and vehicle designers must look to alternative techniques for demonstrating robust and reliable performance of their vehicles prior to operational flight. A space vehicle may undergo only a handful of flight tests in its development cycle, with each flight representing a drastically different flight phase or flight configuration. For instance, NASA’s Space Launch System (SLS) launch vehicle and Orion spacecraft will only see a total of four flight demonstrations before flying a crew on its first operational mission, and each flight demonstrates a unique vehicle configuration and/or set of flight conditions. The SLS will be flown only one time before it becomes operational (Artemis 1). The Orion spacecraft Crew Module (CM) will have been tested twice, once on a Delta IV launch vehicle (Exploration Flight Test 1) and once as a fully integrated system with the SLS launch vehicle (Artemis 1). The Orion Launch abort system will have been tested twice, once in a pad abort scenario (Pad Abort 1) and once in an inflight abort scenario (Ascent Abort 2) on a modified Peacekeeper booster. Both of these latter tests involve only a boiler plate CM, not a functional Orion spacecraft. Thus, unlike aircraft, there is very little opportunity for engineers to assess and evaluate their preflight predictions. Instead, space vehicle designers rely on Monte Carlo flight simulations with detailed dispersions of predicted nominal flight behavior to determine how robust their design is to errors and uncertainties in the flight conditions their vehicle may encounter. These Monte Carlo analyses entail thousands of trajectory simulations to demonstrate that the vehicle can meet design requirements at a specified level of reliability. From an aerodynamics and aerothermodynamics perspective, these trajectory simulations are fueled by an extensive aerodynamic database that covers the complete range of expected flight conditions, vehicle configurations, and flight attitudes expected in a given mission. Today, these databases amount to a table of engineering parameters that can be quickly interrogated by the trajectory simulator. The aerodynamic and aerothermodynamic databases are assembled via a series of ground tests, empirical and analytical analysis, physics-based computational analysis, applicable past flight performance data, and in some cases, engineering judgment. These databases generally take years to assemble for a new space vehicle system and in the case of SLS/Orion, over a decade of test and analysis have been expended to develop the extensive databases required to cover the myriad of configurations and potential flight conditions required for the system. Recently, it has been proposed that Computational Fluid Dynamic (CFD) and computing capability may be reaching a point where it is foreseeable that CFD could be integrated directly into the production trajectory simulation tools used to design NASA’s space vehicles. To demonstrate this, NASA has embarked on two demonstrations of this type of capability, one where six degree of freedom flight trajectory simulation equations are embedded in an existing CFD solver and another where a production CFD solver is loosely coupled with a production trajectory simulation tool. These efforts represent an initial demonstration of a future approach to flight trajectory simulation, but they are a far cry from the capability required to perform a full-up CFD-in-the-loop Monte Carlo trajectory simulation. Therefore, this represents a viable grand challenge for computational methods addressing space vehicle design and development. The final paper/presentation will discuss the many hurdles, beyond simply raw computational power, to realizing this grand challenge and how they map directly to the CFD Vision 2030 ojectives. Among these are the wide range of flight conditions, including accelerating/decelerating flight, encountered by a space vehicle during launch and/or entry. The vehicle can also encounter numerous configuration changes, some of which can be quite drastic, during the course of its flight, so robust, automated geometry modeling, grid generation, and adaptation will play a huge role in reaching this goal. Multiply this by 1000’s of trajectory simulations occurring simultaneously in a given Monte Carlo analysis, and the problem readily scales to absorb virtually any size of supercomputer envisioned today. The concept of CFD-in-the-loop Monte Carlo trajectory simulation poses a formidable challenge for emerging and future computing systems, and it has the potential to shave years off the development cycle for aerodynamic and aerothermodynamic performance predictions as compared to today’s space vehicle design approach.

CFD 2030↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗