Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

METHODS FOR RECONSTRUCTION OF RADIONUCLIDE COMPOSITION AND ACTIVITY OF FISSION PRODUCTS ACCUMULATED IN THE IRRADIATED URANIUM AT THE MOMENT OF ITS RADIOCHEMICAL REPROCESSING AT PLANT “B”, “MAYAK” PA IN THE EARLY 1950s

The article describes calculation procedure for reconstruction of radionuclide composition and activity of fission fragments accumulated in the irridated uranium from “Mayak” PA graphite-uranium reactors at the moment, when irradiation is completed, and at the moment, when the uranium is transferred to radiochemical processing (plant B) in the early 1950s. The procedure includes a reactor model and a cooling pool model. It is based on archive data on monthly uranium unloading and loading in the reactor and in the cooling pool of each reactor. The objects of reconstruction include: order of reloading of uranium versus its location radius in the reactor core; duration of irradiation and radionuclide composition of fission fragments for each radius; order of uranium removal from the cooling pool; effective time of uranium storage in the pool; radionuclide composition and activity of fission fragments in the irradiated uranium delivered to radiochemical reprocessing daily and on average for each month. The model is intended for use in reconstruction of parameters of radionuclide release source into the atmosphere and the source of liquid radioactive waste generation at the “Mayak” PA radiochemical plant.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of regolith/megaregolith insulation on the cooling histories of differentiated asteroids

The cooling histories of differentiated asteroids are calculated employing a variety of thermal-conductivity structures to simulate the potential insulating effects of regolith and megaregolith layers on the cooling rate. It was found that a combination of relatively thick megaregolith and regolith can potentially reduce the core cooling rate by more than a factor of 10 below the rate predicted by models with conventional thermal conductivity structure. Thus, differences in cratering (regolith production) histories may have resulted in radically different cooling rates for asteroids of similar radius, or in similar cooling rates from asteroids of different radius.

Haack, Henning↗

Surface film effects on drop tube undercooling studies

The effects of various gaseous atmospheric constituents on drop-tube solidified samples of elemental metals were examined from a microstructural standpoint. All specimens were prepared from the purest available elements, so effects of impurities should not account for the observed effects. The drop-tube gas has a definite effect on the sample microstructure. Most dramatically, the sample cooling rate is effected. Some samples receive sufficient cooling to solidify in free fall while others do not, splating at the end of the drop tube in the sample catcher. Gases are selectively absorbed into the sample. Upon solidification gas can become less soluble and as a result forms voids within the sample. The general oxidation/reduction characteristics of the gas also affect sample microstructures. In general, under the more favorable experimental conditions including reducing atmospheric conditions and superheatings, examination of sample microstructures indicates that nucleation has been suppressed. This is indicated by underlying uniform dendrite spacings throughout the sample and with a single dendrite orientation through most of the sample. The samples were annealed yielding a few large grains and single or bi-crystal samples were commonly formed. This was especially true of samples that were inadvertently greatly superheated. This is in contrast with results from a previous study in which surface oxides were stable and contained numerous sites of nucleation. The number of nucleation events depends upon the surface state of the specimen as determined by the atmosphere and is consistent with theoretical expectations based upon the thermodynamic stability of surface oxide films. Oxide-free specimens are characterized by shiny surfaces, with no observable features under the scanning electron microscope at 5000X.

Ethridge, E. C.↗

Non-isothermal laminar flow of gases through cooled tubes.

Numerical solutions of the laminar-flow equations in differential form are presented for gas flows through cooled tubes. For nearly isothermal flow there is good agreement with available experimental data, as is also found for the case of a large amount of wall cooling. This correspondence along with a check on the satisfaction of the global momentum and energy constraints allowed an appraisal of the effect of wall cooling on flow through tubes. In general, the effect of wall cooling was to decrease the wall friction and the change in pressure along tubes, but the average heat-transfer coefficient did not vary much.

Back, L. H.↗

Radiative forcing of climate by changes in the vertical distribution of ozone

Results from a one-dimensional radiative-convective equilibrium model (similar to that of Lacis et al., 1981) of surface-temperature changes induced by changes in the vertical distribution of O3 in the atmosphere are parameterized and applied to measurement data for the northern midlatitudes during the 1970s. The construction of the model is outlined, and the results are presented in tables and graphs and discussed in detail. It is found that decreases in O3 in the lower stratosphere in the 1970s caused atmospheric cooling greater than that due to CO2 (thus possibly obscuring the CO2 greenhouse effect) and surface cooling which outweighed the warming effect of increased O3 in the troposphere. The net surface cooling is shown to be equal to about half of the estimated CO2 warming effect for the period.

Lacis, Andrew A.↗

Similarity constraints in testing of cooled engine parts

A study is made of the effect of testing cooled parts of current and advanced gas turbine engines at the reduced temperature and pressure conditions which maintain similarity with the engine environment. Some of the problems facing the experimentalist in evaluating heat transfer and aerodynamic performance when hardware is tested at conditions other than the actual engine environment are considered. Low temperature and pressure test environments can simulate the performance of actual size prototype engine hardware within the tolerance of experimental accuracy if appropriate similarity conditions are satisfied. Failure to adhere to these similarity constraints because of test facility limitations or other reasons, can result in a number of serious errors in projecting the performance of test hardware to engine conditions.

Colladay, R. S.↗

Performance study of the cross-flow Maisotsenko cycle in humid climate conditions

This paper presents a first numerical analysis of the cross-flow Maisotsenko cycle (M-Cycle) below dew-point evaporative cooler for humid climates with model including the water vapor condensation phenomenon. Proposed solution allows to cool ambient air below its dew-point temperature, by utilizing cooling energy in air extracted from the building, due to that it can be used as effective pre-cooling solution for traditional systems. Proposed unit has significant advantage over traditional counter and cross-flow units operating in heat recovery mode, hence it is almost insensitive on temperature of exhaust air. This is caused by effective pre-cooling of the exhaust air in its initial part. Operation in humid climates using cold extracted air results in condensation occurrence in the primary air channels, and hence partial dehumidification of the primary airflow (which allows to cool the air before its dew- point temperature). The Maisotsenko cycle exchanger used to recover heat in the air-conditioning system is compared with Maisotsenko exchanger that operates only on the ambient airflow and does not allow to recover heat from the exhaust airflow from a conditioned space. Achieved results showed that M-Cycle below dew-point air cooler can operate more effectively in humid climates than traditional cross-flow Maisotsenko cycle exchanger.

Condensation↗

Simulation of shot noise effects in the EIC strong hadron cooling accelerator using real number of electrons

In the electron ion collider design, in order to achieve the peak luminosity 10 34 /cm 2 /s with a reasonable lifetime, an efficient coherent electron cooling scheme was proposed to reduce the hadron beam emittance growth. Such a cooling scheme requires a good electron beam quality with a small energy spread. However, the shot noise in the electron beam through the accelerator might be amplified due to the microbunching instability and degrades the electron beam quality in the modulator section of the strong hadron cooling channel and correspondingly cooling rate. In this study, we report on self-consistent simulations of these effects using a real number of electrons to capture the details of shot noise and analysis of the shot noise growth through the accelerator.

Qiang, Ji↗

Effects of spin-orbit coupling on laser cooling of BeI and MgI

We present the ab initio study of spin-orbit coupling effects on laser cooling of BeI and MgI molecules. Potential energy curves for the X{sup 2}Σ{sup +}{sub 1/2}, A{sup 2}Π{sub 1/2,3/2}, and 2{sup 2}Π{sub 3/2,1/2} states are calculated using multi-reference configuration interaction method plus Davidson corrections. Spectroscopic parameters of BeI and MgI are in excellent agreement with available experimental and theoretical values. The A{sup 2}Π{sub 3/2} state of MgI is a repulsive state. It is an unsuitable scheme for the A{sup 2}Π{sub 3/2}(υ′)← X{sup 2}Σ{sup +}{sub 1/2} (υ″) transition for laser cooling of MgI. Highly diagonally distributed Franck-Condon factors f{sub 00} for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) ← X{sup 2}Σ{sup +}{sub 1/2} (υ″ = 0) transitions and suitable radiative lifetimes τ for the A{sup 2}Π{sub 1/2,3/2} (υ′ = 0) of BeI and MgI are obtained. Three laser wavelength drives are required for the A{sup 2}Π{sub 1/2,3/2}(υ′)←X{sup 2}Σ{sup +}{sub 1/2} (υ″) transitions of BeI and MgI. The proposed cooling wavelengths of BeI and MgI are both in the violet region. The results imply the feasibility of laser cooling of BeI and MgI, and that laser cooling of BeI is more possible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation magnetohydrodynamic simulations of protostellar collapse: Low-metallicity environments

Among many physical processes involved in star formation, radiation transfer is one of the key processes because it dominantly controls the thermodynamics. Because metallicities control opacities, they are one of the important environmental parameters that affect star formation processes. In this work, I investigate protostellar collapse in solar-metallicity and low-metallicity (Z = 0.1 Z {sub ☉}) environments using three-dimensional radiation hydrodynamic and magnetohydrodynamic simulations. Because radiation cooling in high-density gas is more effective in low-metallicity environments, first cores are colder and have lower entropies. As a result, first cores are smaller, less massive, and have shorter lifetimes in low-metallicity clouds. Therefore, first cores would be less likely to be found in low-metallicity star forming clouds. This also implies that first cores tend to be more gravitationally unstable and susceptible to fragmentation. The evolution and structure of protostellar cores formed after the second collapse weakly depend on metallicities in the spherical and magnetized models, despite the large difference in the metallicities. Because this is due to the change of the heat capacity by dissociation and ionization of hydrogen, it is a general consequence of the second collapse as long as the effects of radiation cooling are not very large during the second collapse. On the other hand, the effects of different metallicities are more significant in the rotating models without magnetic fields, because they evolve slower than other models and therefore are more affected by radiation cooling.

79 ASTRONOMY AND ASTROPHYSICS↗

On the stabilization of three-dimensional boundary layers by suction and cooling

A significant reduction in the drag of transonic aircraft can be achieved by using an active method of boundary-layer control to maintain laminar flow on the aerodynamic surfaces. The stabilizing influence of suction for both favorable and adverse pressure gradients is demonstrated by means of the self-similar incompressible three-dimensional boundary layers on yawed wedges. Profile instability is measured by the maximum amplification rate of fixed-frequency disturbances computed according to linearized, locally parallel, spatial stability theory. Suction is found to be more effective in controlling Tollmien-Schlichting instability than stationary cross-flow disturbances. The effectiveness of surface cooling as a method of stabilization is compared with suction for the boundary layers on a transonic 35 deg swept wing of infinite span. It is found from compressible stability theory that when the surface is cooled to a uniform temperature such that the maximum cross-flow velocity is reduced by the same amount as with a uniform suction distribution, the stabilizing effect of cooling on cross-flow disturbances is less than with suction.

Mack, L. M.↗

Experimental Investigation of Turbine Vane Heat Transfer for Alternative Fuels

The focus of this program was to experimentally investigate advanced gas turbine cooling schemes and the effects of and factors that contribute to surface deposition from particulate matter found in coal syngas exhaust flows on turbine airfoil heat transfer and film cooling, as well as to characterize surface roughness and determine the effects of surface deposition on turbine components. The program was a comprehensive, multi-disciplinary collaborative effort between aero-thermal and materials faculty researchers and the Department of Energy, National Energy Technology Laboratory (NETL). The primary technical objectives of the program were to evaluate the effects of combustion of syngas fuels on heat transfer to turbine vanes and blades in land-based power generation gas turbine engines. The primary questions to be answered by this investigation were; What are the factors that contribute to particulate deposition on film cooled gas turbine components? An experimental program was performed in a high-temperature and pressure combustion rig at the DOE NETL; What is the effect of coal syngas combustion and surface deposition on turbine airfoil film cooling? Deposition of particulate matter from the combustion gases can block film cooling holes, decreasing the flow of the film coolant and the film cooling effectiveness; How does surface deposition from coal syngas combustion affect turbine surface roughness? Increased surface roughness can increase aerodynamic losses and result in decreased turbine hot section efficiency, increasing engine fuel consumption to maintain desired power output. Convective heat transfer is also greatly affected by the surface roughness of the airfoil surface; Is there any significant effect of surface deposition or erosion on integrity of turbine airfoil thermal barrier coatings (TBC) and do surface deposits react with the TBC in any way to decrease its thermal insulating capability? Spallation and erosion of TBC is a persistent problem in modern turbine engines; and What advancements in film cooling hole geometry and design can increase effectiveness of film cooling in turbines burning high-hydrogen coal syngas due to the higher heat loads and mass flow rates of the core flow? Experimental and numerical investigations of advanced cooling geometries that can improve resistance to surface deposition were performed. The answers to these questions were investigated through experimental measurements of turbine blade surface temperature and coolant coverage (via infrared camera images and thermocouples) and time-varying surface roughness in the NETL high-pressure combustion rig with accelerated, simulated surface deposition and advanced cooling hole concepts, coupled with detailed materials analysis and characterization using conventional methods of Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD), 3-D Surface Topography (using a 3-D stylus profilometer). Detailed surface temperatures and cooling effectiveness could not be measured due to issues with the NETL infrared camera system. In collaboration with faculty startup funding from the principal investigator, experimental and numerical investigations were performed of an advanced film cooling hole geometry, the anti-vortex hole (AVH), focusing on improving cooling effectiveness and decreasing the counter-rotating vortex of conventional cooling holes which can entrain mainstream particulate matter to the surface. The potential benefit of this program is in gaining a fundamental understanding of how the use of alternative fuels will effect the operation of modern gas turbine engines, providing valuable data for more effective cooling designs for future turbine systems utilizing alternative fuels.

10 SYNTHETIC FUELS↗

Shock/shock interference on a transpiration cooled hemispherical model

Experimental results are presented which show the effectiveness of transpiration cooling in reducing the peak heat flux caused by an impinging shock on a bow shock of a hemispherical model. The 12-inch diameter hemispherical transpiration model with helium coolant was tested in the Calspan 48-inch Hypersonic Shock Tunnel at nominal Mach 12.1 and freestream unit Reynolds number of 0.33 x 10 to the 6th/ft. An incident shock wave, generated by a blunt flat-plate shock generator inclined at 10 deg to the freestream, intersected the bow shock of the model to produce shock/shock interference. The stagnation heat flux without coolant or shock/shock interference was about 1.6 times a smooth surface laminar prediction due to effective roughness of the coolant ejection slots. A coolant mass flux 31 percent of the freestream mass flux reduced the stagnation heat flux to zero without shock/shock interference. However, for the same coolant mass flux and with shock/shock interference the peak heat flux was only reduced 8.3 percent, even though the total integrated heat load was reduced.

Nowak, Robert J.↗

Effects of Hot Streak and Phantom Cooling on Heat Transfer in a Cooled Turbine Stage Including Particulate Deposition

The objective of this research effort was to develop a validated computational modeling capability for the characterization of the effects of hot streaks and particulate deposition on the heat load of modern gas turbines. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. A 1-year no cost extension request was approved for this effort, so the total duration was 4 years. The research effort succeeded in its ultimate objective by leveraging extensive experimental deposition studies complemented by computational modeling. Experiments were conducted with hot streaks, vane cooling, and combinations of hot streaks with vane cooling. These studies contributed to a significant body of corporate knowledge of deposition, in combination with particle rebound and deposition studies funded by other agencies, to provide suitable conditions for the development of a new model. The model includes the following physical phenomena: elastic deformation, plastic deformation, adhesion, and shear removal. It also incorporates material property sensitivity to temperature and tangential-normal velocity rebound cross-dependencies observed in experiments. The model is well-suited for incorporation in CFD simulations of complex gas turbine flows due to its algebraic (explicit) formulation. This report contains model predictions compared to coefficient of restitution data available in the open literature as well as deposition results from two different high temperature turbine deposition facilities. While the model comparisons with experiments are in many cases promising, several key aspects of particle deposition remain elusive. The simple phenomenological nature of the model allows for parametric dependencies to be evaluated in a straightforward manner. This effort also included the first-ever full turbine stage deposition model published in the open literature. The simulations included hot streaks and simulated vane cooling. The new deposition model was implemented into the CFD model as a wall boundary condition, with various particle sizes investigated in the simulation. Simulations utilizing a steady mixing plane formulation and an unsteady sliding mesh were conducted and the flow solution of each was validated against experimental data. Results from each of these simulations, including impact and capture distributions and efficiencies, were compared and potential reasons for differences discussed in detail. The inclusion of a large range of particle sizes allowed investigation of trends with particle size, such as increased radial migration and reduced sticking efficiency at the larger particle sizes. The unsteady simulation predicted lower sticking efficiencies on the rotor blades than the mixing plane simulation for the majority of particle sizes. This is postulated to be due to the preservation of the hot streak and cool vane wake through the vane-rotor interface (which are smeared out circumferentially in the mixing-plane simulation). The results reported here represent the successful implementation of a novel deposition model into validated vane-rotor flow solutions that include a non-uniform inlet temperature profile and simulated vane cooling.

42 ENGINEERING↗

Instability of compressible boundary layers along curved walls with suction or cooling

This paper investigates the effect of suction of the boundary layer and wall cooling on the growth and development of three-dimensional longitudinal vortices over concave walls. The study is carried out for compressible flows for a range of Mach numbers from 0 to 5. Despite indications that small suction or small cooling rates locally reduce the critical Goertler number (destabilize the boundary layer), the overall effect of suction or cooling is to stabilize the boundary layer by reducing the amplitude ratio of the vortices. In case of suction, this becomes more difficult with increasing Mach number unless high suction rates are used. On the other hand, stabilizing the boundary layer with respect to Goertler vortices can hardly be achieved by cooling even when high cooling rates are used.

El-Hady, N. M.↗

Transient Three-Dimensional Startup Side Load Analysis of a Regeneratively Cooled Nozzle

The objective of this effort is to develop a computational methodology to capture the startup side load physics and to anchor the computed aerodynamic side loads with the available data from a regeneratively cooled, high-aspect-ratio nozzle, hot-fired at sea level. The computational methodology is based on an unstructured-grid, pressure-based, reacting flow computational fluid dynamics and heat transfer formulation, a transient 5 s inlet history based on an engine system simulation, and a wall temperature distribution to reflect the effect of regenerative cooling. To understand the effect of regenerative wall cooling, two transient computations were performed using the boundary conditions of adiabatic and cooled walls, respectively. The results show that three types of shock evolution are responsible for side loads: generation of combustion wave; transitions among free-shock separation, restricted-shock separation, and simultaneous free-shock and restricted shock separations; along with the pulsation of shocks across the lip, although the combustion wave is commonly eliminated with the sparklers during actual test. The test measured two side load events: a secondary and lower side load, followed by a primary and peak side load. Results from both wall boundary conditions captured the free-shock separation to restricted-shock separation transition with computed side loads matching the measured secondary side load. For the primary side load, the cooled wall transient produced restricted-shock pulsation across the nozzle lip with peak side load matching that of the test, while the adiabatic wall transient captured shock transitions and free-shock pulsation across the lip with computed peak side load 50% lower than that of the measurement. The computed dominant pulsation frequency of the cooled wall nozzle agrees with that of a separate test, while that of the adiabatic wall nozzle is more than 50% lower than that of the measurement. The computed teepee-like formation and the tangential motion of the shocks during lip pulsation also qualitatively agree with those of test observations. Moreover, a third transient computation was performed with a proportionately shortened 1 s sequence, and lower side loads were obtained with the higher ramp rate.

Wang, Ten-See↗

Two-dimensional cold-air cascade study of a film-cooled turbine stator blade. 1: Experimental results of pressure-surface film cooling tests

The effect of film coolant ejection from the pressure side of a stator blade was determined in a two-dimensional cascade. Stator exit surveys were made for each of six rows of coolant holes. Successive multirow tests were made with two, three, four, five, and six rows of coolant holes open. The results of the multirow tests are compared with the predicted multirow performance obtained by adding the single-row data. Results are presented in terms of stator primary-air efficiency as a function of coolant fraction.

Moffitt, T. P.↗