Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

On estimating scale invariance in stratocumulus cloud fields

Examination of cloud radiance fields derived from satellite observations sometimes indicates the existence of a range of scales over which the statistics of the field are scale invariant. Many methods were developed to quantify this scaling behavior in geophysics. The usefulness of such techniques depends both on the physics of the process being robust over a wide range of scales and on the availability of high resolution, low noise observations over these scales. These techniques (area perimeter relation, distribution of areas, estimation of the capacity, d0, through box counting, correlation exponent) are applied to the high resolution satellite data taken during the FIRE experiment and provides initial estimates of the quality of data required by analyzing simple sets. The results of the observed fields are contrasted with those of images of objects with known characteristics (e.g., dimension) where the details of the constructed image simulate current observational limits. Throughout when cloud elements and cloud boundaries are mentioned; it should be clearly understood that by this structures in the radiance field are meant: all the boundaries considered are defined by simple threshold arguments.

Seze, Genevieve↗

A Balloon-Borne Cloud Condensation Nuclei Counter

A balloon-borne instrument was constructed for observations of vertical profiles of cloud condensation nucleus (CCN) concentrations, active at 1% supersaturation. Droplet concentration in the static thermal-gradient diffusion chamber is deduced from the amount of scattered laser light detected by a photodetector. The photodetector is calibrated using a video camera and computer system to count the number of droplets produced from NaCl aerosol. Preliminary data are available from nine early morning profiles obtained at Laramie, Wyoming, between June 1995 and January 1997. To complement the CCN measurements, instruments that measure condensation nuclei (CN) and aerosols with diameter greater than 0.30 micrometers (D(sub 0.3) were also included on the balloon package. CCN concentrations exhibited a general decrease from the surface to the top of the boundary layers, were generally uniform through well-mixed layers, and show variability above well-mixed layers. In general, the structure of the CCN profile appears to be closely related to the structure in the CN and D(sub 0.3) profiles. Summer profiles generally have CCN concentration greater than 200/cu cm up to 500 mbar, whereas winter profiles are less than 200/cu cm at all levels.

Delene, David J.↗

Petaflops Computing: The Key Algorithmic Challenges

The prospect of petaflops-class computers brings to the fore some important algorithmic issues that have been considered in the high performance computing community for several years. Key among them are (1) concurrency (whether the fundamental concurrency of an algorithm is sufficient to keep thousands of processors productively busy); (2) data locality; (3) latency tolerance; and (4) memory and operation count scaling. This introductory presentation will give an overview of these issues.

Bailey, David H.↗

The X-ray Spectrum of the North Polar Spur

An analysis is presented of the soft X-ray background spectrum measured by the EPIC MOS cameras on XMM-Newton in three observations targeted on the North Polar Spur (NPS). Three distinct Galactic plasma components are identified, a cool Local Hot Bubble (LHB) component, T(sub lo) approx. 0.1 keV, a cool Galactic Halo component at a similar temperature and a hotter component, T(sub hi) approx. 0.26 keV, associated with the NPS itself. Using the new data in combination with the Rosat All-Sky Survey count rates measured in the 0.1-0.4 keV band, we estimate the emission measure of the LHB material to be 0.0040-0.0052 cm(exp -6) pc, which implies an electron density of 0.008-0.011 cm(exp -3) and pressure of approx. 22000 cm(exp -3) K. The halo and NPS components lie behind at least 50% of the line-of-sight cold gas for which the total Galactic column density is in the range (2 - 8) x 10(exp 20) cm(exp -2). Modelling the X-ray emitting superbubble as a sphere at distance 210 pc, radius 140 pc and center l(sub II) = 352 deg, b(sub II) = 15 deg, the implied electron density in the NPS is approx. 0.03 cm(exp -3) with pressure approx. 150000 cm(exp -3) K. The observed spectral line complexes from OVII, OVIII, FeXVII, NeIX, NeX and MgXI provide constraints on the composition of the plasma. The hot component in the NPS is depleted in oxygen, neon and, to some extent, magnesium and iron. Assuming the effective line of sight across the halo emission is 1 kpc, the electron density in the halo is 0.007-0.011 cm(exp -3) and the pressure is approx. 16500 cm(exp -3) K, conditions very similar to those in the LHB.

Willingale, Richard↗

Detecting the Sun in 2-Gyr Old Open Clusters

The aim of this observation was to take advantage of the large collecting area and sensitivity of the European Space Agency's XMM-Newton telescope to survey the X ray brightness of solar-mass stars in the 2 Gyr old NGC 752 cluster in order to chart out the dependence of coronal X ray emission of Sun like stars as a function of age. Dr. Simon's stated role as one of the co-investigators in the project was limited to assisting the project's European Principal Investigator with the analysis and interpretation of the X ray measurements, and to assist in summarizing the results for publication. The observation was executed successfully, and approximately 130 X ray sources were detected in the XMM field of view and subsequently measured to obtain X ray count rates. To date neither the measurements nor the raw data have been distributed by the European P.I. to the co-investigators, It is expected that the measurements will be distributed to the co-investigators by the end of 2004, and once that is done, the scientific analysis by Dr. Simon can then begin. At present, since the data and measurements have not been shared with the co-investigators, there are no results to report.

Simon, Theodore↗

"Fly-by-Wireless": A Revolution in Aerospace Vehicle Architecture for Instrumentation and Control

Aerospace vehicle programs have always counted on the cables and connectors to provide power, grounding, data and time synchronization throughout a vehicle's life-cycle. Even with numerous improvements, wiring and connector problems and sensors continue to be key failure points, causing many hours of troubleshooting and replacement. Costly flight delays have been precipitated by the need to troubleshoot cables/connections, and/or repair a sensor. Wiring continues to be too expensive to remove once it is installed, even with the weight penalties. Miles of test instrumentation and low flight sensor wires still plague the aerospace industry. New technology options for data connectivity, processing and micro/nano manufacturing are making it possible to retrofit existing vehicles, like the Space Shuttle. New vehicles can now develop architectures that provide for and take advantage of alternatives to wired connectivity. This project motivates the aerospace industry and technology providers to establish: (1) A new emphasis for system engineering approaches to reduce cables and connectors. (2) Provisions for modularity and accessibility in the vehicle architecture. (3) A set of technologies that support alternatives to wired connectivity.

Studor, George↗

Analysis of the Variation of Energetic Electron Flux with Respect to Longitude and Distance Normal to the Magnetic Equatorial Plane for Galileo Energetic Particle Detector Data

In this study we examine ten-minute omni-directional averages of energetic electron data measured by the Galileo spacecraft Energetic Particle Detector (EPD). Count rates from electron channels B1, DC2, and DC3 are evaluated using a power law model to yield estimates of the differential electron fluxes from 1 MeV to 11 MeV at distances between 8 and 51 Jupiter radii. Whereas the orbit of the Galileo spacecraft remained close to the rotational equatorial plane of Jupiter, the approximately 11 degree tilt of the magnetic axis of Jupiter relative to its rotational axis allowed the EPD instrument to sample high energy electrons at limited distances normal to the magnetic equatorial plane. We present a Fourier analysis of the semi-diurnal variation of electron fluxes with longitude.

synchrotron radiation↗

Processing circuitry for single channel radiation detector

Processing circuitry is provided for a high voltage operated radiation detector. An event detector utilizes a comparator configured to produce an event signal based on a leading edge threshold value. A preferred event detector does not produce another event signal until a trailing edge threshold value is satisfied. The event signal can be utilized for counting the number of particle hits and also for controlling data collection operation for a peak detect circuit and timer. The leading edge threshold value is programmable such that it can be reprogrammed by a remote computer. A digital high voltage control is preferably operable to monitor and adjust high voltage for the detector.

Holland, Samuel D.↗

Predicting Lifetime of a Thermomechanically Loaded Component

NASALIFE is a computer program for predicting the lifetime, as affected by low cycle fatigue (LCF) and creep rupture, of a structural component subject to temporally varying, multiaxial thermomechanical loads. The component could be, for example, part of an aircraft turbine engine. Empirical data from LCF tests, creep rupture tests, and static tensile tests are used as references for predicting the number of missions the component can withstand under a given thermomechanical loading condition. The user prepares an input file containing the creep-rupture and cyclic-fatigue information, temperature-dependent material properties, and mission loading and control flags. The creep rupture information can be entered in tabular form as stress versus life or by means of parameters of the Larson-Miller equation. The program uses the Walker mean-stress model to adjust predicted life for ranges of the ratio between the maximum and minimum stresses. Data representing complex load cycles are reduced by the rainflow counting method. Miner's rule is utilized to combine the damage at different load levels. Finally, the program determines the total damage due to creep and combines it with the fatigue damage due to the cyclic loading and predicts the approximate number of missions a component can endure before failing.

Murthy, Pappu L. N.↗

I/O Performance Characterization of Lustre and NASA Applications on Pleiades

In this paper we study the performance of the Lustre file system using five scientific and engineering applications representative of NASA workload on large-scale supercomputing systems such as NASA s Pleiades. In order to facilitate the collection of Lustre performance metrics, we have developed a software tool that exports a wide variety of client and server-side metrics using SGI's Performance Co-Pilot (PCP), and generates a human readable report on key metrics at the end of a batch job. These performance metrics are (a) amount of data read and written, (b) number of files opened and closed, and (c) remote procedure call (RPC) size distribution (4 KB to 1024 KB, in powers of 2) for I/O operations. RPC size distribution measures the efficiency of the Lustre client and can pinpoint problems such as small write sizes, disk fragmentation, etc. These extracted statistics are useful in determining the I/O pattern of the application and can assist in identifying possible improvements for users applications. Information on the number of file operations enables a scientist to optimize the I/O performance of their applications. Amount of I/O data helps users choose the optimal stripe size and stripe count to enhance I/O performance. In this paper, we demonstrate the usefulness of this tool on Pleiades for five production quality NASA scientific and engineering applications. We compare the latency of read and write operations under Lustre to that with NFS by tracing system calls and signals. We also investigate the read and write policies and study the effect of page cache size on I/O operations. We examine the performance impact of Lustre stripe size and stripe count along with performance evaluation of file per process and single shared file accessed by all the processes for NASA workload using parameterized IOR benchmark.

Saini, Subhash↗

Studying the effects of overlapping objects in dark energy

Observing the clustering of galaxies allows us to calculate cosmological parameters necessary for understanding dark energy. However, as the density of observed objects increases, the probability of these objects blending likewise increases, causing multiple galaxies to be observed as one. This affects the inferred values of parameters such as the galaxy bias (b) and the matter energy density (ΩM). To see whether the bias from incorrectly inferring the galaxy count is significant, we compare the correlation functions in simulated data for “true” and “observed” data sets with one-to-one and multiple-to-one correspondences, respectively. For each data set, we create two correlation functions: one “measured” function directly relying on the galaxies’ positions using the TreeCorr python library, and one “model” derived mathematically from the galaxies’ power spectrum using the Cosmological Core Library (CCL). By minimizing the residual between these two functions, we compute the ideal values for b and ΩM across the various possible redshifts that position the galaxies in three dimensional space. This minimization is done with an Markov chain Monte Carlo (MCMC) estimate that finds one value of ΩM and ten values for b corresponding to the ten redshift bins ranging from z = 0.2 to z = 1.2. We find that neither b nor ΩM is particularly affected by inclusion of blended galaxies. Though there is room for improvement, the data suggests that the fluctuations we found are a result of noise or limitations on the modeling rather than blending explicitly.

79 ASTRONOMY AND ASTROPHYSICS↗

A 32-channel photon counting module with embedded auto/cross-correlators for real-time parallel fluorescence correlation spectroscopy

Fluorescence correlation spectroscopy (FCS) is a well-established technique to study binding interactions or the diffusion of fluorescently labeled biomolecules in vitro and in vivo. Fast FCS experiments require parallel data acquisition and analysis which can be achieved by exploiting a multi-channel Single Photon Avalanche Diode (SPAD) array and a corresponding multi-input correlator. This paper reports a 32-channel FPGA based correlator able to perform 32 auto/cross-correlations simultaneously over a lag-time ranging from 10 ns up to 150 ms. The correlator is included in a 32 × 1 SPAD array module, providing a compact and flexible instrument for high throughput FCS experiments. However, some inherent features of SPAD arrays, namely afterpulsing and optical crosstalk effects, may introduce distortions in the measurement of auto- and cross-correlation functions. We investigated these limitations to assess their impact on the module and evaluate possible workarounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of the influence of the data acquisition system sampling rate on the accuracy of measured acceleration loads for transport aircraft

A research effort was initiated at National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC), to describe the relationship between the sampling rate and the accuracy of acceleration loads obtained from the data acquisition system of a transport aircraft. An accelerometer was sampled and digitized at a rate of 100 samples per second onboard a NASA Boeing 737 (B-737) flight research aircraft. Numerical techniques were used to reconstruct 2.5 hours of flight data into its original input waveform and then re-sample the waveform into rates of 4, 8, 16, and 32 samples per second. Peak-between-means counting technique and power spectral analysis were used to evaluate each sampling rate using the 32 samples per second data as the comparison. This paper presents the results from these methods and includes in appendix A, the peak-between-means counting results used in a general fatigue analysis for each of the sampling rates.

Whitehead, Julia H.↗

MOLA II Laser Transmitter Calibration and Performance

The goal of the document is to explain the algorithm for determining the laser output energy from the telemetry data within the return packets from MOLA II. A simple algorithm is developed to convert the raw start detector data into laser energy, measured in millijoules. This conversion is dependent on three variables, start detector counts, array heat sink temperature and start detector temperature. All these values are contained within the return packets. The conversion is applied to the GSFC Thermal Vacuum data as well as the in-space data to date and shows good correlation.

Afzal, Robert S.↗

SAIL-Net CloudPuck CCN Data

SAIL-Net is a DOE funded project in the East River Watershed near Crested Butte, Colorado with the goal of advancing our understanding of aerosol-cloud interactions in complex, mountainous regions. Through the deployment of a network of six low cost microphysics nodes in Fall 2021 in the same domain at the SAIL campaign, SAIL-Net provides data on aerosol size distributions, cloud condensation nuclei (CCN), and ice nucleations particles (INP). This network enables the investigation of small-scale variations in complex terrain. This specific dataset provides the cleaned data recorded from the CloudPuck, an in house instrument made by Handix Scientific that counts CCN concentrations. The CloudPuck was deployed at the sites for the summer/fall of 2022 before winter conditions were too harsh to maintain the instrument. For more information on the the CloudPuck or how the raw data are processed, see the read me.

54 ENVIRONMENTAL SCIENCES↗

Scene correction (precision techniques) of ERTS sensor data using digital image processing techniques

Techniques have been developed, implemented, and evaluated to process ERTS Return Beam Vidicon (RBV) and Multispectral Scanner (MSS) sensor data using digital image processing techniques. The RBV radiometry has been corrected to remove shading effects, and the MSS geometry and radiometry have been corrected to remove internal and external radiometric and geometric errors. The results achieved show that geometric mapping accuracy of about one picture element RMS and two picture elements (maximum) can be achieved by the use of nine ground control points. Radiometric correction of MSS and RBV sensor data has been performed to eliminate striping and shading effects to about one count accuracy. Image processing times on general purpose computers of the IBM 370/145 to 168 class are in the range of 29 to 3.2 minutes per MSS scene (4 bands). Photographic images of the fully corrected and annotated scenes have been generated from the processed data and have demonstrated excellent quality and information extraction potential.

Bernstein, R.↗

Coupling Secretomics with Enzyme Activities To Compare the Temporal Processes of Wood Metabolism among White and Brown Rot Fungi

Wood-degrading fungi use a sequence of oxidative and hydrolytic mechanisms to loosen lignocellulose and then release and metabolize embedded sugars. These temporal sequences have recently been mapped at high resolution using directional growth on wood wafers, revealing previously obscured dynamics as fungi progressively colonize wood. Here, we applied secretomics in the same wafer design to track temporal trends on aspen decayed by fungi with distinct nutritional modes: two brown rot-type (BR) fungi (Postia placenta, Gloeophyllum trabeum) and two white rot (WR) (Stereum hirsutum, Trametes versicolor). We matched secretomic data from three zones of decay (early, middle, late) with enzyme activities in these zones, and we included measures of total protein and ergosterol as benchmarks. In line with previous transcriptomics data, all of fungi tested showed an initial investment in pectinases and a delayed investment in other glycoside hydrolases (GHs). Brown rot fungi also staggered abundance of some oxidoreductases ahead of GHs to produce a familiar two-step mechanism. White rot fungi, however, showed late-stage investment in pectinases as well, unlike brown rot fungi. Lignolytic enzyme activities and abundances were also different between the two white rot fungi. Specifically, S. hirsutum lignolytic activity was delayed, explained almost entirely by the activity and abundance of five ‘atypical’ type manganese peroxidases, unlike more varied peroxidases and laccases in T. versicolor. These secretomic analyses support brown rot patterns generated via transcriptomics, they reveal distinct patterns among and within rot types, and they link spectral counts with activities to help functionalize these multi-strain secretomic data.

fungi, secretome, Proteomics, Lignin↗

Defining blood hematology reference values in female pig-tailed macaques ( Macaca nemestrina ) using the Isolation Forest algorithm

Background: Pig-tailed macaques (PTMs) are commonly used as preclinical models to assess antiretroviral drugs for HIV prevention research. Drug toxicities and disease pathologies are often preceded by changes in blood hematology. To better assess the safety profile of pharmaceuticals, we defined normal ranges of hematological values in PTMs using an Isolation Forest (iForest) algorithm. Methods: Eighteen female PTMs were evaluated. Blood was collected 1–24 times per animal for a total of 159 samples. Complete blood counts were performed, and iForest was used to analyze the hematology data to detect outliers. Results: Median, IQR, and ranges were calculated for 13 hematology parameters. From all samples, 22 outliers were detected. These outliers were excluded from the reference index. Conclusions: Using iForest, we defined a normal range for hematology parameters in female PTMs. This reference index can be a valuable tool for future studies evaluating drug toxicities in PTMs.

59 BASIC BIOLOGICAL SCIENCES↗