Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

The performance of a multistep proportional counter for use in X-ray astronomy

The addition of a parallel field preamplification region has been shown to dramatically improve the performance of a standard multiwire proportional counter, permitting high overall gas gains to be achieved, a prerequisite for good spatial resolution, without in any way compromising energy resolution. The resulting device, known as a multistep detector, has been tested over a wide range of operating conditions and fill gas mixtures. Results are presented here detailing the performance available with argon and xenon as the principal gases, these being of particular relevance to X-ray astronomy.

Ramsey, B. D.↗

Disk-resolved spectral reflectance properties of Phobos from 0.3-3.2 micron: Preliminary integrated results from Phobos 2

The Phobos 2 mission provided multispectral observations of Phobos over a large wavelength range and with relatively high spectral resolution. Here, researchers integrate results from three multispectral detectors by determining the ultraviolet-visible near infrared spectral properties of color and brightness features recognized in VSK TV images. Researchers present evidence that there are two fundamental spectral units within the region of overlapping coverage by the detectors. They describe the units' spectral and reflectance properties and discuss the implications of these results for the composition of Phobos.

Murchie, Scott L.↗

Shifts of the Al-26 line due to Galactic rotation

The shape of the Al-26 line is evaluated using a Galactic disk rotation curve and assuming various galactic distributions of radioactive aluminum. The line shape depends on galactic longitude, detector opening angle, and the assumed aluminum distribution. For a detector of 20 deg aperture and 2.5 keV resolution, the shift of the line peak can be as large as 0.4 keV. Such a shift could be detected with the proposed nuclear astrophysics explorer.

Skibo, Jeff↗

Determination of (C-12)/(C-13) in the interstellar medium toward Zeta Ophiuchi and Xi Persei

The Lick Observatory Reticon (LOR) data presented in Hawkins et al. (1985) are reanalyzed in order to determine the cause of the significant discrepancy in (C-12)/(C-13) isotope ratios determined on the basis of observations of this isotope in the interstellar medium toward Zeta Ophiuchi and Xi Persei. A new set of Lick Observatory observations toward Zeta Oph are obtained using a CCD detector. The KPNO coude feed echelle spectrograph and a CCD detector are used to carry out high-resolution, high SNR ratio observations toward Zeta Oph and Xi Per. The LOR results for Zeta Oph are uncertain, ranging to 40 to 60, owing to the error in continuum placement. The KPNO results toward Zeta Oph are (C-12)H/(C-13)H(+)(0, 0) = 63 +/- 8, (C-12)H(+)/(C-13)H(+)(1, 0) = 67 +/- 19, and (C-12)N/(C-13)N = 100 + 88/- 33. Toward Xi Per, the KPNO measurements yield (C-12)H(+)/(C-13)H(+) = 49 +/- 15 from the 4232-A band, and a lower limit of 45 from the 3957-A observations.

Hawkins, Isabel↗

The Scientific Impact of the GHRS on our Understanding of the Local Interstellar Medium

A high-resolution echelle grating and low-noise Digicon detectors make the GHRS an excellent instrument for studying ultraviolet absorption lines formed in the local interstellar medium (LISM). The GHRS has observed interstellar gas absorption along several dozen fines of sight toward stars; many of these stars are located within 100 pc of the Sun and thus sample the LISM properties quite well. We will summarize how the analysis of these beautiful echelle spectra permit us to study four important but closely interrelated topics about the LISM: (1) the dynamics and structure of the warm interstellar clouds, (2) the temperature, density, and other physical properties of the gas, (3) the chemical composition and chemical depletions in the gas phase, and (4) the interaction of the interstellar gas with the ionized hot winds of the Sun and other stars.

Linsky, Jeffrey L.↗

Initial Performance of the Aspect System on the Chandra Observatory: Post-Facto Aspect Reconstruction

The aspect system of the Chandra Observatory plays a key role in realizing the full potential of Chandra's x-ray optics and detectors. To achieve the highest spatial and spectral resolution (for grating observations), an accurate post-facto time history of the spacecraft attitude and internal alignment is needed. The CXC has developed a suite of tools which process sensor data from the aspect camera assembly and gyroscopes, and produce the spacecraft aspect solution. In this poster, the design of the aspect pipeline software is briefly described, followed by details of aspect system performance during the first eight months of flight. The two key metrics of aspect performance are: image reconstruction accuracy, which measures the x-ray image blurring introduced by aspect; and celestial location, which is the accuracy of detected source positions in absolute sky coordinates.

Aldcroft, T.↗

Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

Degnan, John J.↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗

Impacts of Cross-Platform Vicarious Calibration on the Deep Blue Aerosol Retrievals for Moderate Resolution Imaging Spectroradiometer Aboard Terra

The retrieval of aerosol properties from spaceborne sensors requires highly accurate and precise radiometric measurements, thus placing stringent requirements on sensor calibration and characterization. For the Terra/Moderate Resolution Imaging Spedroradiometer (MODIS), the characteristics of the detectors of certain bands, particularly band 8 [(B8); 412 nm], have changed significantly over time, leading to increased calibration uncertainty. In this paper, we explore a possibility of utilizing a cross-calibration method developed for characterizing the Terral MODIS detectors in the ocean bands by the National Aeronautics and Space Administration Ocean Biology Processing Group to improve aerosol retrieval over bright land surfaces. We found that the Terra/MODIS B8 reflectance corrected using the cross calibration method resulted in significant improvements for the retrieved aerosol optical thickness when compared with that from the Multi-angle Imaging Spectroradiometer, Aqua/MODIS, and the Aerosol Robotic Network. The method reported in this paper is implemented for the operational processing of the Terra/MODIS Deep Blue aerosol products.

Jeong, Myeong-Jae↗

Modeling Methods for 3D Lightning Mapping from Space

Global lightning detection has advanced greatly over the past few decades both on ground and from orbit. Ground-based systems like the Lightning Mapping Array (LMA) excel at high-precision 3D reconstruction of local flashes, while spaceborne lightning sensors have much larger potential coverage but are limited by coarser resolution and often rely on data from other instruments to determine 3D flash locations. CubeSpark is a new mission concept focused on combining these two methods in the form of six small satellites in low-Earth orbit. CubeSpark will combine RF and bispectral optical measurements of lightning in order to map the 3D structure of both individual flashes and their parent thunderstorms at 1-2 km spatial resolution on a global scale, enabling a host of new atmospheric, climate, and space electricity studies. The goal of this study is to assess the feasibility and expected resolution of lightning mapping via indivudal VHF sources using different methods and detector combinations. Flashes were simulated beneath orbital configurations consisting of 1-6 satellites, taking into account the complicated interactions with Earth's ionosphere. In the multi-satellite (>5) approach, RF detectors on each satellite measure the arrival times of impulsive VHF sources to collectively pinpoint their locations in 3D and reconstruct flashes with higher resolution than has been achieved from space. The same can process can be performed with 3-4 satellites by constraining sources' horizontal locations with onboard optical imagers. A 1-2 station approach follows the established method of determining the height of an RF source using the arrival time difference between direct RF waves and their reflections off the Earth's surface. Here we present preliminary results of the expected accuracy of these methods to inform potential satellite missions like CubeSpark.

Lightning↗

2023 Astrophotonics Roadmap: Pathways to Realizing Multi-Functional Integrated Astrophotonic Instruments

Photonic technologies offer numerous functionalities that can be used to realize astrophotonic instruments. The most spectacular example to date is the ESO Gravity instrument at the Very Large Telescope in Chile that combines the light-gathering power of four 8 m telescopes through a complex photonic interferometer. Fully integrated astrophotonic devices stand to offer critical advantages for instrument development, including extreme miniaturization when operating at the diffraction-limit, as well as integration, superior thermal and mechanical stabilization owing to the small footprint, and high replicability offering significant cost savings. Numerous astrophotonic technologies have been developed to address shortcomings of conventional instruments to date, including for example the development of photonic lanterns to convert from multimode inputs to single mode outputs, complex aperiodic fiber Bragg gratings to filter OH emission from the atmosphere, complex beam combiners to enable long baseline interferometry with for example, ESO Gravity, and laser frequency combs for high precision spectral calibration of spectrometers. Despite these successes, the facility implementation of photonic solutions in astronomical instrumentation is currently limited because of (1) low throughputs from coupling to fibers, coupling fibers to chips, propagation and bend losses, device losses, etc, (2) difficulties with scaling to large channel count devices needed for large bandwidths and high resolutions, and (3) efficient integration of photonics with detectors, to name a few. In this roadmap, we identify 24 key areas that need further development. We outline the challenges and advances needed across those areas covering design tools, simulation capabilities, fabrication processes, the need for entirely new components, integration and hybridization and the characterization of devices. To realize these advances the astrophotonics community will have to work cooperatively with industrial partners who have more advanced manufacturing capabilities. With the advances described herein, multi-functional integrated instruments will be realized leading to novel observing capabilities for both ground and space based platforms, enabling new scientific studies and discoveries.

astrophotonics↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summer 2025 SULI: Nucleus ID, TinyTPC, and Scientific Communication

This paper summarizes my work during the Summer 2025 SULI internship, which focused on two main projects and broader scientific development. The first project involved improving the particle identification (PID) of protons, deuterons, and tritons using PIDA distributions and template fitting, with the goal of modeling nuclear final-state interactions (FSI) and testing the robustness of the method against systematic uncertainties. These techniques pave the way for future application to LArTPC data from the ICARUS detector. The second project centered on the optimization and data-taking of the TinyTPC detector, a compact LArTPC used for high-resolution low-energy measurements. I adjusted gain and threshold parameters, performed hardware validation tests, and developed analysis strategies to extract meaningful physics from collected data. Throughout the summer, I also enhanced my scientific communication and mentorship skills through presentations, collaborative analysis, and peer guidance.

McCright, Hannah [Maryland U.]↗

Long Term Performance Stability of TES Detectors

We are developing superconducting transition-edge sensor (TES) microcalorimeter arrays for a variety of applications such as ground-based laboratory astrophysics experiments and next generation space-based X-ray missions. These detectors can provide X-ray spectral information with an unprecedent resolution of ~2 eV at 6 keV and have been selected for the X-ray Integral Field Unit (X-IFU) instrument of ESA’s large flagship mission Athena. To maintain detector performance over the lifetime of the mission, it is important to understand whether environmental conditions that the detector may be exposed to will affect its properties over time. This “aging” begins right after the array leaves the fabrication environment, with potential exposure to humidity, oxygen, or elevated temperatures which may affect the detector performance. In a few prior arrays we have observed increased fall times in the pulse shape and/or the introduction of anomalous low energy tails on the X-ray spectrum. This is thought to be an indication of “aging” on chips exposed to such conditions, causing e.g. changes in the absorber properties. In this contribution, we report on a systematic characterization of TES properties, before and after exposing the chip to various controlled temperature and humidity levels and assess the changes in the measured transition and pulse shapes, energy resolution, and spectral redistribution.

S Beaumont↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Infrared astronomy after IRAS

The development of infrared astronomy in the wake of IRAS is discussed. Attention is given to an overview of next generation infrared telescope technology, with emphasis on the Space Infrared Telescope Facility (SIRTF) which has been built to replace IRAS in the 1990s. Among the instruments to be included on SIRTF are: a wide-field high-resolution camera covering the infrared range 3-30 microns with large arrays of detectors; an imaging photometer operating in the range 3-700 microns; and a spectrograph covering the range 2.5-200 microns with resolutions of 2 and 0.1 percent. Observational missions for the SIRTF are proposed in connection with: planetary formation; star formation; cosmic energy sources; active galactic nuclei; and quasars.

Rieke, G. H.↗

Record Low NEP in the Hot-Electron Titanium Nanobolometers

We are developing hot-electron superconducting transition-edge sensors (TES) capable of counting THz photons and operating at T = 0.3K. We fabricated superconducting Ti nanosensors with Nb contacts with a volume of approx. 3x10(exp -3) cu microns on planar Si substrate and have measured the thermal conductance due to the weak electron-phonon coupling in the material G = 4x10(exp -14) W/K at 0.3 K. The corresponding phonon-noise NEP = 3x10(exp -19) W/Hz(sup 1/2). Detection of single optical photons (1550nm and 670nm wavelength) has been demonstrated for larger devices and yielded the thermal time constants of 30 microsec at 145 mK and of 25 microsec at 190 mK. This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with (nu) > 1 THz where NEP approx. 3x10(exp -20) W/Hz(sup 1/2) is needed for spectroscopy in space.

transition edge sensors↗