Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Wire, hybrid, and laser-cut X-pinches as Talbot–Lau backlighters for electron density diagnostics

Talbot–Lau x-ray deflectometry (TXD) enables refraction-based imaging for high-energy-density physics experiments, and thus, it has been studied and developed with the goal of diagnosing plasmas relevant to inertial confinement and magnetic liner inertial fusion. X-pinches, known for reliably generating fast (~1 ns), small (~1 µm) x-ray sources, were driven on the compact current driver generator for ablation structure and implosion studies (~200 kA, 150 ns) as a potential backlighter source for TXD. Considering that different X-pinch configurations have characteristic advantages and drawbacks as x-ray generating loads, three distinct copper X-pinch configurations were studied: the wire X-pinch, the hybrid X-pinch, and the laser-cut X-pinch. Furthermore, the Cu K-shell emission from each configuration was characterized and analyzed regarding the specific backlighter requirements for an 8 keV TXD system: spatial and temporal resolution, number of sources, time of emission, spectrum, and reproducibility. Recommendations for future experimental improvements and applications are presented. The electron density of static objects was retrieved from Moiré images obtained through TXD. This allowed to calculate the mass density of static samples within 4% of the expected value for laser-cut X-pinches, which were found to be the optimal X-pinch configuration for TXD due to their high reproducibility, small source size (≤5 µm), short duration (~1 ns), and up to 106 W peak power near 8 keV photon energy. Plasma loads were imaged through TXD for the first-time using laser-cut X-pinch backlighting. Experimental images were compared with simulations from the x-ray wave-front propagation code, demonstrating that TXD can be a powerful x-ray refraction-based diagnostic for dense Z-pinch loads. Future plans for Talbot–Lau interferometry diagnostics in the pulsed-power environment are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic x-ray source using electrons produced by a 100 J-class picosecond laser

Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f/#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.

backlighter↗

A reduced model for the ICF gamma-ray reaction history diagnostic

An analytic model for the gamma reaction history (GRH) diagnostic to be fielded on the National Ignition Facility is described. The application of the GRH diagnostic for the measurement of capsule rho-R during burn using 4.4 MeV carbon gamma rays is demonstrated by simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The He/Ne beam diagnostic for line-ratio spectroscopy in the island divertor of Wendelstein 7-X

a versatile gas injection system and an absolute calibrated spectroscopic observation system with more than 200 lines-of-sight have been installed in two divertor locations in the Wendelstein 7-X stellarator. This powerful setup enables among other measurements to infer T e and n e in the divertor region by means of line-ratio spectroscopy on thermal helium. This is a robust and routinely used diagnostic at W7-X and this work describes its main characteristics and shows some examples of T e and n e profiles. In particular it is shown that the inclusion of high Rydberg states in the helium collisional-radiative model is necessary to obtain a realistic estimate of T e . The applicability of the diagnostic is currently being extended towards the low T e and high n e conditions occurring during detachment by means of line-ratio spectroscopy on neon. Initial T e , n e profiles obtained with a neon-beam are here presented.

47 OTHER INSTRUMENTATION↗

The Wendelstein 7-X phase contrast imaging diagnostic

We report a phase contrast imaging (PCI) diagnostic has been developed for the Wendelstein 7-X (W7-X) stellarator. The PCI diagnostic provides a line-integrated measurement of turbulent electron density fluctuations, which is essential for understanding high performance scenarios that can lead to improved confinement at fusion-relevant temperatures and densities. The PCI system is also sensitive to coherent fluctuations, which arise from Alfvén eigenmodes or other MHD activity. This paper provides an overview of the hardware and the optical system and presents an example PCI measurement from the W7-X OP1.2b experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated assessment model diagnostics: key indicators and model evolution

Integrated assessment models (IAMs) form a prime tool in informing climate mitigation strategies. Diagnostic indicators that allow to compare these models can help to describe and explain differences in model projections. This also increases transparency and comparability. Earlier, the IAM community has developed an approach to diagnose models (Kriegler et al., 2015). Here we build on this, by proposing a selected set of well-defined indicators as a community standard, similar to metrics used for other modeling communities such as climate models. These indicators are the relative abatement index (RAI), emission reduction type index (ERT), inertia timescale (IT), fossil fuel reduction (FFR), transformation index (TI) and cost per abatement value (CAV). We apply the approach to 17 IAMs, including both older version as well as their latest versions, as applied in the IPCC 6th Assessment Report (AR6). The study shows that the approach can be easily applied and allows for comparison of model versions in time. The indicators and their trends can often be explained in terms of model characteristics and changes. We show that together, the set of six indicators can provide an useful indication of the main traits of the model and can roughly indicate the general model behavior. The results also show that there is often a considerable spread across the models. Interestingly, the diagnostic values often change for different model versions, but there does not seem to be a distinct trend across the different models.

54 ENVIRONMENTAL SCIENCES↗

A NEW DIAGNOSTIC OF THE RADIAL DENSITY STRUCTURE OF Be DISKS

We analyze the intrinsic polarization of two classical Be stars in the process of losing their circumstellar disks via a Be to normal B star transition originally reported by Wisniewski et al. During each of five polarimetric outbursts which interrupt these disk-loss events, we find that the ratio of the polarization across the Balmer jump (BJ+/BJ-) versus the V-band polarization traces a distinct loop structure as a function of time. Since the polarization change across the Balmer jump is a tracer of the innermost disk density whereas the V-band polarization is a tracer of the total scattering mass of the disk, we suggest that such correlated loop structures in Balmer jump-V-band polarization diagrams (BJV diagrams) provide a unique diagnostic of the radial distribution of mass within Be disks. We use the three-dimensional Monte Carlo radiation transfer code HDUST to reproduce the observed clockwise loops simply by turning 'on/off' the mass decretion from the disk. We speculate that counterclockwise loop structures we observe in BJV diagrams might be caused by the mass decretion rate changing between subsequent 'on/off' sequences. Applying this new diagnostic to a larger sample of Be disk systems will provide insight into the time-dependent nature of each system's stellar decretion rate.

79 ASTRONOMY AND ASTROPHYSICS↗

SOLAR TRANSITION REGION LINES OBSERVED BY THE INTERFACE REGION IMAGING SPECTROGRAPH: DIAGNOSTICS FOR THE O IV AND Si IV LINES

The formation of the transition region O IV and Si IV lines observable by the Interface Region Imaging Spectrograph (IRIS) is investigated for both Maxwellian and non-Maxwellian conditions characterized by a κ-distribution exhibiting a high-energy tail. The Si IV lines are formed at lower temperatures than the O IV lines for all κ. In non-Maxwellian situations with lower κ, the contribution functions are shifted to lower temperatures. Combined with the slope of the differential emission measure, it is possible for the Si IV lines to be formed at very different regions of the solar transition region than the O IV lines; possibly close to the solar chromosphere. Such situations might be discernible by IRIS. It is found that photoexcitation can be important for the Si IV lines, but is negligible for the O IV lines. The usefulness of the O IV ratios for density diagnostics independently of κ is investigated and it is found that the O IV 1404.78 Å/1399.77 Å ratio provides a good density diagnostics except for very low T combined with extreme non-Maxwellian situations.

79 ASTRONOMY AND ASTROPHYSICS↗

SPITZER IRAC COLOR DIAGNOSTICS FOR EXTENDED EMISSION IN STAR-FORMING REGIONS

The infrared data from the Spitzer Space Telescope are an invaluable tool for identifying physical processes in star formation. In this study, we calculate the Infrared Array Camera (IRAC) color space of UV fluorescent H{sub 2} and polycyclic aromatic hydrocarbon (PAH) emission in photodissociation regions (PDRs) using the Cloudy code with PAH opacities from Draine and Li. We create a set of color diagnostics that can be applied to study the structure of PDRs and to distinguish between FUV-excited and shock-excited H{sub 2} emission. To test this method, we apply these diagnostics to Spitzer IRAC data of NGC 2316. Our analysis of the structure of the PDR is consistent with previous studies of the region. In addition to UV excited emission, we identify shocked gas that may be part of an outflow originating from the cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Line identification of boron and nitrogen emissions in EUV and VUV wavelength ranges in the impurity powder dropping experiments of LHD and its application to spectroscopic diagnostics

An impurity powder dropper was installed in the 21st campaign of the Large Helical Device experiment (Oct. 2019–Feb. 2020) under a collaboration between the National Institute for Fusion Science and the Princeton Plasma Physics Laboratory for the purposes of real-time wall conditioning and edge plasma control. In order to assess the effective injection of the impurity powders, spectroscopic diagnostics were applied to observe line emission from the injected impurity. Therefore, extreme-ultraviolet (EUV) and vacuum-ultraviolet (VUV) emission spectra were analyzed to summarize observable impurity lines with B and BN powder injection. Emission lines released from B and N ions were identified in the EUV wavelength range of 5–300 Å measured using two grazing incidence flat-field EUV spectrometers and in the VUV wavelength range of 300–2400 Å measured using three normal incidence 20 cm VUV spectrometers. BI–BV and NIII–NVII emission lines were identified in the discharges with the B and BN powder injection, respectively. Useful B and N emission lines which have large intensities and are isolated from other lines were successfully identified as follows: BI (1825.89, 1826.40) Å (blended), BII 1362.46 Å, BIII (677.00, 677.14, 677.16) Å (blended), BIV 60.31 Å, BV 48.59 Å, NIII (989.79, 991.51, 991.58) Å (blended), NIV 765.15 Å, NV (209.27, 209.31) Å (blended), NVI 1896.80 Å, and NVII 24.78 Å. Applications of the line identifications to the advanced spectroscopic diagnostics were demonstrated, such as the vertical profile measurements for the BV and NVII lines using a space-resolved EUV spectrometer and the ion temperature measurement for the BII line using a normal incidence 3 m VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microscale and Nanoscale Electrophotonic Diagnostic Devices

Detecting and identifying infectious agents and potential pathogens in complex environments and characterizing their mode of action is a critical need. Traditional diagnostics have targeted a single characteristic, e.g. spectral response, surface receptor, mass, intrinsic conductivity, etc. However, advances in detection technologies have identified emerging approaches in which multiple modes of action are combined to obtain enhanced performance characteristics. Particularly appealing in this regard, electrophotonic devices capable of coupling light to electron translocation have experienced rapid recent growth and offer significant advantages for diagnostics. In this chapter, we explore three specific promising approaches that combine electronics and photonics: (a) assays based on closed bipolar electrochemistry coupling electron transfer to color or fluorescence (b) sensors based on localized surface plasmon resonances, and (c) emerging nanophotonics approaches, such as those based on zero-mode waveguides and metamaterials.

60 APPLIED LIFE SCIENCES↗

Demonstration of x-ray fluorescence spectroscopy as a sensitive temperature diagnostic for high-energy-density physics experiments

We present the use of x-ray fluorescence spectroscopy (XFS) to a sensitive temperature diagnostic in shocked foams at temperatures of 30–75 eV. Cobalt-doped foams were shock compressed using a planar drive at the OMEGA laser facility and photo-pumped with a Zn He⁢𝛼 x-ray source. Analysis of the resulting cobalt 𝐾⁢𝛽 x-ray fluorescence spectra using collisional radiative codes allows the temperature to be determined in the shocked foams. Furthermore, this method provides a sensitive and robust technique to determine temperatures in high-energy-density physics experiments in the tens of electronvolts temperature range. In these experiments, we find that radiation hydrodynamic simulations predict a lower temperature in the shocked foams compared to analysis of the XFS data using collisional radiative models. Although additional experiments with an independent temperature diagnostic to absolutely calibrate XFS spectra for these conditions will be required to resolve this discrepancy, these results demonstrate the excellent temperature sensitivity of XFS spectra for high-energy-density physics experiments.

Atomic spectra↗

Dirac $R$-matrix calculations for the electron-impact excitation of neutral tungsten providing noninvasive diagnostics for magnetic confinement fusion

Neutral tungsten is the primary candidate as a wall material in the divertor region of the International Thermonuclear Experimental Reactor (ITER). The efficient operation of ITER depends heavily on precise atomic physics calculations for the determination of reliable erosion diagnostics, helping to characterize the influx of tungsten impurities into the core plasma. The following paper presents detailed calculations of the atomic structure of neutral tungsten using the multiconfigurational Dirac-Fock method, drawing comparisons with experimental measurements where available, and includes a critical assessment of existing atomic structure data. We investigate the electron-impact excitation of neutral tungsten using the Dirac R-matrix method, and by employing collisional-radiative models, we benchmark our results with recent Compact Toroidal Hybrid measurements. The resulting comparisons highlight alternative diagnostic lines to the widely used 400.88-nm line.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray diagnostics for the cavity-based x-ray free-electron laser project

The success of x-ray free-electron lasers (XFELs) in recent years has greatly advanced many scientific fields. However, most of these XFELs suffer from a low longitudinal coherence and instabilities due to the stochastic start-up process. A cavity-based x-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent and stable x-ray sources. One of the challenges of a CBXFEL is the requirement for the μ⁢m−sized electron bunches to fully overlap in three dimensions with the circulating μ⁢m−sized x-ray pulses in an x-ray cavity tens or hundreds of meters long. We present here the development of an x-ray diagnostics system for accurate alignment of x-ray beams in the CBXFEL cavity. The system was developed within the framework of a CBXFEL research and development collaboration among Argonne National Laboratory, SLAC National Accelerator Laboratory, and Spring-8. All the designed diagnostic components have been fully characterized at the Advanced Photon Source to demonstrate a capability for sub-μ⁢rad angular and μ⁢m spatial alignment of the CBXFEL cavity.

Free-electron lasers↗

Instrumentation with Hall sensors for JET magnetic diagnostics. The results of the recent deuterium campaign at JET in 2009

Magnetic diagnostics is one of the main diagnostics in thermonuclear reactors, and thus enhancing the accuracy of the magnetic field measurement is a relevant task. The paper discusses the principles of construction for magnetic measuring instrumentation based upon the application of steady-state radiation-resistant semiconductor sensors, and the results of its implementation for magnetic field measurement in one of the largest operating reactors JET (Joint European Torus) during the recent deuterium campaign. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics, Control and Performance Parameters for the BELLA High Repetition Rate Petawatt Class Laser

A laser system producing controllable and stable pulses with high power and ultrashort duration at high repetition rate is a key component of a high energy laser-plasma accelerator (LPA). Precise characterization and control of laser properties are essential to understanding laser-plasma interactions required to build a 10-GeV class LPA. This study discusses the diagnostics, control and performance parameters of a 1 Hz, 1 petawatt (PW) class laser at the Berkeley Lab Laser Accelerator (BELLA) facility. The BELLA PW laser provided up to 46 J on target with a 1% level energy fluctuation and 1.3-μrad pointing stability. The spatial profile was measured and optimized by using a camera, wavefront sensor, and deformable mirror (ILAO system). The focus waist was measured to be r 0 = 53 μm and the fraction of energy within the circular area defined by the first minimum of the diffraction pattern (r = 67 μm) was 0.75. The temporal profile was controlled via the angle of incidence on a stretcher and a compressor, as well as an acousto-optic programmable dispersive. The temporal pulse shape was measured to be about 33 fs in full width at half maximum (WIZZLER and GRENOUILLE diagnostics). In order to accurately evaluate peak intensity, the energy-normalized peak fluence, and energy-normalized peak power were analyzed for the measured spatial and temporal mode profiles, and were found to be 15 kJ/(cm 2 J) with 6% fluctuation (standard deviation) and 25 TW/J with 5% fluctuation for 46-J on-target energy, respectively. This yielded a peak power of 1.2 PW and a peak intensity of 17×10 18 W/cm 2 with 8% fluctuation. A method to model the pulse shape for arbitrary compressor grating distance with high accuracy was developed. The pulse contrast above the amplified spontaneous emission pedestal was measured by SEQUOIA and found to be better than 10 9 . The first order spatiotemporal couplings (STCs) were measured with GRENOUILLE, and a simulation of the pulse's evolution at the vicinity of the target was presented. A maximum pulse front tilt angle of less than 7 mrad was achieved. The reduction of the peak power caused by the first order STCs was estimated to be less than 1%. Finally, the capabilities described in this paper are essential for generation of high quality electron beams.

47 OTHER INSTRUMENTATION↗

PANDA-FES: Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science

Nuclear fusion is a potential source of carbon-free electricity with many concepts in development. The Portable and Adaptable Neutron Diagnostics for Advancing Fusion Energy Science (PANDA-FES) suite has been deployed since 2021 to measure neutron yield, energy, and spatiotemporal source location at two different Z-pinch fusion devices. This diagnostic can be used at a variety of facilities pursuing fusion in the magnetic, inertial, and magneto-inertial regimes. These different regimes have a wide range of time scales from less than 100 ns to a few μ s, neutron yields from 10 6 to 10 11 , and noise environments. Neutron yield is measured through activation of 79 Br and 89 Y with calibrated detectors. Temporal, spatial, and energy dependence of neutrons is measured with scintillators coupled to photomultiplier tubes (PMTs). Experimental setups and data analysis methods have been developed for these conditions. Finally, neutron yield, neutron energy anisotropy, and spatiotemporal evolution of the source have been measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pleural homocysteine for malignant pleural effusion: A prospective and double‐blind diagnostic test accuracy study

Abstract Objective To assess the accuracy of pleural fluid homocysteine for discriminating malignant pleural effusion (MPE) and benign pleural effusion (BPE). Methods A total of 194 patients from two cohorts (Hohhot and Changshu) with undiagnosed pleural effusion were prospectively enrolled. Their pleural homocysteine was measured, and its diagnostic accuracy and net benefit for MPE were analyzed by receiver operating characteristic (ROC) curve analysis and decision curve analysis, respectively. Results In the Hohhot cohort ( n = 136) and the Changshu cohort ( n = 58), MPE patients had significantly higher homocysteine levels than BPE patients. The areas under the ROC curves of homocysteine for the diagnosis of MPE were 0.61 ( p = 0.027) and 0.59 ( p = 0.247), respectively. The decision curves of homocysteine were close to the reference line in both the Hohhot cohort and the Changshu cohort. Conclusion The diagnostic accuracy of pleural fluid homocysteine for MPE was low.

Cao, Xi‐Shan↗