Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Materials Science↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel deuterium–tritium (DT) neutron activation diagnostics for increased neutron yield operations at Sandia’s Z-facility (invited)

As inertial confinement fusion experiments at Sandia National Laboratories’ Z-facility begin using deuterium–tritium (DT) fuels, the expected DT-neutron yields are expected to increase many orders of magnitude. This brings about the need for diagnostics that have a significantly higher dynamic range of operation and ability to obtain yields where there will be significant radiation holds. Using the current activation diagnostic infrastructure at the Z-facility, a pair of activation diagnostics are being developed. Here, the first is fluorine activation, which will be used in a similar manner to current copper activation diagnostics that are fielded in a rabbit for quick removal from the experiments without opening the vacuum experiment containment. The second is a prompt DT-neutron detector that exploits the activation of oxygen with similar operation characteristics as the current Be-probes fielded at Z. We will discuss the design of this pair of instruments, along with calibration work performed at Sandia’s Ion Beam Laboratory in support of the development and anticipated instrument performance.

Mangan, Michael Antony↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Inference of the neutron down-scatter ratio using neutron time-of-flight data for DT-layered implosions on the OMEGA laser

First analysis of the neutron time of flight (nTOF) data is presented to infer the areal density using the neutron down-scatter ratio (DSR) for OMEGA deuterium–tritium (DT)-layered (cryogenic) implosions. The required very-high-dynamic range (nTOF) signal is constructed using an nTOF detector [Forrest et al., Rev. Sci. Ins. 83, 10D919 (2012)] with multiple time-gated photomultiplier tubes. The nTOF data are analyzed using a forward-fit technique to account for the detector responses and infer the DSR and areal density for DT-layered implosions. The areal densities inferred using this analysis are found to be in agreement with the areal densities measured using the magnetic recoil spectrometer detector that is located in a similar line-of-sight. This work establishes the feasibility of the DSR measurement using nTOF data on OMEGA and provides an additional areal-density measurement that will benefit the assessment of the implosion performance and 3D reconstruction of the imploded core.

47 OTHER INSTRUMENTATION↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of 2D spatio-temporal visualisation techniques for the pulsed THz-radiation field using an electro-optic crystal

Two 2D techniques for visualising the field of pulsed THz radiation (‘shadow’ and ‘interferometric’), which are based on the linear electro-optical effect with application of a ZnTe detector crystal 1 × 1 cm in size, are compared. The noise level and dynamic range for the aforementioned techniques are analysed and their applicability limits are discussed. (thz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technique for measuring basic characteristics of electron-optical cameras

A procedure is described for determining the basic parameters of linear-sweep electron-optical cameras. The techniques are considered for measuring the limiting temporal resolution and dynamic range of the PS-1/S1 camera using a femtosecond laser and sinusoidal-modulated laser radiation. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive nonequilibrium design of actin-based metamaterials: Fundamental and practical limits of control

The adaptive and surprising emergent properties of biological materials self-assembled in far-from-equilibrium environments serve as an inspiration for efforts to design nanomaterials. In particular, controlling the conditions of self-assembly can modulate material properties, but there is no systematic understanding of either how to parameterize external control or how controllable a given material can be. Here, we demonstrate that branched actin networks can be encoded with metamaterial properties by dynamically controlling the applied force under which they grow and that the protocols can be selected using multi-task reinforcement learning. These actin networks have tunable responses over a large dynamic range depending on the chosen external protocol, providing a pathway to encoding “memory” within these structures. Interestingly, we obtain a bound that relates the dissipation rate and the rate of “encoding” that gives insight into the constraints on control—both physical and information theoretical. Taken together, these results emphasize the utility and necessity of nonequilibrium control for designing self-assembled nanostructures.

59 BASIC BIOLOGICAL SCIENCES↗

Dissecting neurofilament tail sequence-phosphorylation-structure relationships with multicomponent reconstituted protein brushes

Neurofilaments (NFs) are multisubunit, bottlebrush-shaped intermediate filaments abundant in the axonal cytoskeleton. Each NF subunit contains a long intrinsically disordered tail domain, which protrudes from the NF core to form a “brush” surrounding each NF. Precisely how the tails’ variable charge patterns and repetitive phosphorylation sites mediate their conformation within the brush remains an open question in axonal biology. We address this problem by grafting recombinant NF tail protein constructs NF-Light, -Medium, and -Heavy (NFL, NFM, and NFH) to surfaces, yielding protein brushes of defined stoichiometry that can be phosphorylated in vitro. Atomic force microscopy measurements reveal that brush height depends on composition monotonically but not always linearly for binary NFL:NFM or NFL:NFH systems, and that NFM-based brushes are highly extended, while brushes incorporating the much larger NFH are surprisingly compact even after multisite phosphorylation. Complementary self-consistent field theory (SCFT) predicts multilayer brush morphologies for NFM and phosphorylated NFH brushes. Further experiments and SCFT analysis with designed mutants reveal that N-terminal negative charges in the NFH tail repel phosphorylated residues to generate the multilayer morphology, while the C-terminal charge-neutral region contributes to multilayer brush morphology but not total brush height. Charge-shuffled NFM variants show that charge segregation promotes brush collapse near physiological ionic strengths. Collectively, this study supports a role for NFM in establishing a dynamic range for NF brush conformation, lending insight into previous in vitro and in vivo findings. More broadly, this work establishes a platform for dissecting contributions of disordered protein sequence to conformation at interfaces.

Science & Technology - Other Topics↗

Bistable random momentum transfer in a linear on-chip resonator

Optical switches and bifurcation rely on the nonlinear response of materials. Here, we demonstrate linear temporal bifurcation responses in a passive multimode microresonator, with strongly coupled chaotic and whispering gallery modes (WGMs). In microdisks, the chaotic modes exhibit broadband transfer within the deformed cavities, but their transient response is less explored and yields a random output of the analog signal distributed uniformly from “0” to “1.” Here, we build chaotic states by perturbing the multimode microring resonators with densely packed silicon nanocrystals on the waveguide surface. In vivo measurements reveal random and “digitized” output that ONLY populates around 0 and 1 intensity levels. The bus waveguide mode couples first to chaotic modes, then either dissipates or tunnels into stable WGMs. This binary pathway generates high-contrast, digitized outputs. In conclusion, the fully passive device enables real-time conversion of periodic clock signals into binary outputs with contrasts exceeding 12.3 dB, data rates of up to 10 7 · bits per second, and 20 dB dynamic range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancing the High Throughput Identification of Liver Fibrosis Protein Signatures Using Multiplexed Ion Mobility Spectrometry

Rapid diagnosis of disease states using less invasive, safer, and more clinically acceptable approaches than presently employed is an imperative goal for the field of medicine. While mass spectrometry (MS)-based proteomics approaches have attempted to meet these objectives, challenges such as the enormous dynamic range of protein concentrations in clinically relevant biofluid samples coupled with the need to address human biodiversity have slowed their employment. Herein, we report on the use of a new platform that addresses these challenges by coupling technical advances in rapid gas phase multiplexed ion mobility spectrometry (IMS) separations [1, 2] with liquid chromatography (LC) and MS to dramatically increase measurement sensitivity and throughput, further enabling future MS-based clinical applications. An initial application of the LC-IMS-MS platform for the analysis of blood serum samples from stratified post-liver transplant patients with recurrent fibrosis progression illustrates its potential utility for disease characterization and use in personalized medicine [3, 4].

Environmental Molecular Sciences Laboratory↗

Enhancements to the New TREAT Automatic Reactor Control System (ARCS)

The Transient Reactor Test (TREAT) facility recently replaced the automatic reactor control system (ARCS). Here, this paper discusses some of the enhancements that were made during the ARCS replacement such as calculations to take into account the nonadiabatic effects and increasing the dynamic range for power and period indication. This paper also discusses upgrades that had been planned but were unable to implemented and potential upgrades for the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗