Quasi-optimal decoding of linear block codes using soft decision detection

A simple but effective decoding procedure, applicable to any (n,k) linear block code with symbols from GF(q), is described. The technique involves a transformation of the parity check equations which focuses the code's correction power on the soft symbol set while still retaining the capability to correct one symbol error from outside this set. The soft symbol set is defined to be the n-k least reliably detected code symbol positions whose parity check row-spaces are linearly independent. The process generates a number of error vector screening candidates, each a solution to the parity check equations, and the maximum-likelihood candidate is accepted.

Greene, E. P.↗

Subjective evaluation of the combined influence of satellite temperature sounding data and increased model resolution on numerical weather forecasting

The present evaluation is concerned with (1) the significance of prognostic differences resulting from the inclusion of satellite-derived temperature soundings, (2) how specific differences between the SAT and NOSAT prognoses evolve, and (3) comparison of two experiments using the Goddard Laboratory for Atmospheric Sciences general circulation model. The subjective evaluation indicates that the beneficial impact of sounding data is enhanced with increased resolution. It is suggested that satellite sounding data posses valuable information content which at times can correct gross analysis errors in data sparse regions.

Atlas, R.↗

DEKFIS user's guide: Discrete Extended Kalman Filter/Smoother program for aircraft and rotorcraft data consistency

The computer program DEKFIS (discrete extended Kalman filter/smoother), formulated for aircraft and helicopter state estimation and data consistency, is described. DEKFIS is set up to pre-process raw test data by removing biases, correcting scale factor errors and providing consistency with the aircraft inertial kinematic equations. The program implements an extended Kalman filter/smoother using the Friedland-Duffy formulation.

Source record↗

Boresighting techniques for the Antenna Control Assembly (ACA)

Comparison of four scanning schemes including CONSCAN indicates that CONSCAN with signal cleanup and protection processes has the greatest merit in terms of accuracy, dependability and automatic unattended operation. Specific problem areas, error sources, and corrective measures are discussed.

Abichandani, K. P.↗

Comparison of wheat classification accuracy using different classifiers of the image-100 system

Classification results using single-cell and multi-cell signature acquisition options, a point-by-point Gaussian maximum-likelihood classifier, and K-means clustering of the Image-100 system are presented. Conclusions reached are that: a better indication of correct classification can be provided by using a test area which contains various cover types of the study area; classification accuracy should be evaluated considering both the percentages of correct classification and error of commission; supervised classification approaches are better than K-means clustering; Gaussian distribution maximum likelihood classifier is better than Single-cell and Multi-cell Signature Acquisition Options of the Image-100 system; and in order to obtain a high classification accuracy in a large and heterogeneous crop area, using Gaussian maximum-likelihood classifier, homogeneous spectral subclasses of the study crop should be created to derive training statistics.

Dejesusparada, N.↗

Visible infrared spin-scan radiometers (VISSR) for the Geostationary Operational Environmental Satellite (GOES) B and C application

Two visible infrared spin scan radiometer (VISSR) instruments provided for the Geostationary Operational Environmental Satellite B and C (GOES B and C) spacecrafts are described. The instruments are identical to those supplied previously are summarized. A significant number of changes primarily involving corrections of drawing errors and omissions were also performed. All electrical changes were breadboarded (where complexity required this), were incorporated into the test module, and subjected to verification of proper operation throughout fall instrument temperature range. Evaluation of the changes also included design operating safety margins to account for component variations and life.

Source record↗

The resonance line of B II in IUE spectra of chemically peculiar stars

A description is presented of high-dispersion spectroscopic observations of eight chemically peculiar stars including Kappa Cnc and Mu Lep, and of one normal comparison star, Nu Cap, in the vicinity of 1362 A. The reported data were obtained with the International Ultraviolet Explorer during the first 15 months of its operation. The initial reduction of the data, which were originally described in a qualitative summary by Leckrone (1980), was affected by a serious error in the calibration of the instrument's intensity transfer function. This error has been corrected in the currently presented data. The results of spectrum syntheses of the 1362 A feature are also described for several of the stars.

Leckrone, D. S.↗

Automatic weld torch guidance control system

A highly reliable, fully digital, closed circuit television optical, type automatic weld seam tracking control system was developed. This automatic tracking equipment is used to reduce weld tooling costs and increase overall automatic welding reliability. The system utilizes a charge injection device digital camera which as 60,512 inidividual pixels as the light sensing elements. Through conventional scanning means, each pixel in the focal plane is sequentially scanned, the light level signal digitized, and an 8-bit word transmitted to scratch pad memory. From memory, the microprocessor performs an analysis of the digital signal and computes the tracking error. Lastly, the corrective signal is transmitted to a cross seam actuator digital drive motor controller to complete the closed loop, feedback, tracking system. This weld seam tracking control system is capable of a tracking accuracy of + or - 0.2 mm, or better. As configured, the system is applicable to square butt, V-groove, and lap joint weldments.

Smaith, H. E.↗

Documentation for the machine-readable version of the Uppsala general catalogue of galaxies

The machine-readable version of the catalog containing descriptions of galaxies, their surrounding areas, and position angles for flattened galaxies is described. In addition to the correction of several errors discovered in a previous computerized version, a few duplicate records were removed and the record structure was revised slightly to accommodate a large data value and to remove superfluous blanks.

Warren, W. H., Jr.↗

Optical alignment measurements at Goddard Space Flight Center

The significant changes that have been made in the Optical Alignment Facility at the Goddard Space Flight Center since it was last described (Appler and Howell, 1968) are discussed. The changes are reflected in both the hardware and the software involved in making alignment measurements. The data analysis procedures can now be done on a desktop computer with turn-around times of approximately 4 h. Arbitrary coordinate transformations and corrections for facility errors are also feasible while retaining absolute accuracies of less than 6 sec of arc.

Eichhorn, W. L.↗

Active wavefront correction in large telescopes

Astronomical progress with the MMT telescope, which attains high-resolution imaging by partial compensation for atmospheric distortion, is discussed. The small tertiary and beam combiner mirrors at the MMT bring six images to a common focus, where there is a TV system for acquisition and guiding. Individual image positions can be controlled by stepper motors driving actuators on the secondaries, each step moving an image 0.05 arc seconds in the focal plane. The instrument's correction for image jiggle due to atmospheric turbulence and drift of the relative positions of the images due to gravitational and thermal effects on the structure are described. A scheme for correcting residual structural errors is discussed. It appears that the telescope can work to about the 17th visual magnitude. For faint sky limited objects comparable performance would require a perfectly rigid single mirror of the same aperture to have 50 percent more collecting area and cost at least 1.5 times more.

Angel, J. R. P.↗

The PDS for space telescope guide star selection system: Status and improvements

Pointing the ST (Space Telescope) requires that the onboard guidance system be provided with the coordinates and magnitudes of at least two guide stars for each observation region. The accuracy and limitations of the model 2020G PDS microdensitometer are assessed in view of the guide star requirements of the space telescope. Modifications of the PDS to correct for measuring errors are reviewed.

Kinsey, J. H.↗

Analysis of experimental shaft seal data for high-performance turbomachines, as for Space Shuttle main engines

High-pressure, high-temperature seal flow (leakage) data for nonrotating and rotating Raleigh-step and convergent-tapered-bore seals were characterized in terms of a normalized flow coefficient. The data for normalized Rayleigh-steip and nonrotating tapered-bore seals were in reasonable agreement with theory, but data for the rotating tapered-bore seals were not. The tapered-bore-seal operational clearances estimated from the flow data were significantly larger than calculated. Although clearances are influenced by wear from conical to cylindrical geometry and errors in clearance corrections, the problem was isolated to the shaft temperature - rotational speed clearance correction. The geometric changes support the use of some conical convergence in any seal. Under these conditions rotation reduced the normalized flow coefficiently by nearly 10 percent.

Hendricks, R. C.↗

High-density digital recording

The problems associated with high-density digital recording (HDDR) are discussed. Five independent users of HDDR systems and their problems, solutions, and insights are provided as guidance for other users of HDDR systems. Various pulse code modulation coding techniques are reviewed. An introduction to error detection and correction head optimization theory and perpendicular recording are provided. Competitive tape recorder manufacturers apply all of the above theories and techniques and present their offerings. The methodology used by the HDDR Users Subcommittee of THIC to evaluate parallel HDDR systems is presented.

Kalil, F.↗

Archival of Poker Flat MST radar data

The Poker Flat MST (mesosphere stratosphere troposphere) radar has operated from early 1979 to 1985. The data recorded during that time resides on some 1100 magnetic tapes. A second set containing only the derived parameters of velocity, width and signal to noise of the primary echo at each height, plus the noise spectra, occupies another 250 tapes. While processing to generate the compressed data set does correct some known errors, no attempt has been made to identify or remove spurious echoes. Because the Poker Flat data set is such a unique and valuable resource, a proposal is made to archive the data in forms more useful for analysis. The archived data set would contain only the parameters for significant echoes with contamination from airplanes, unwanted ionospheric returns, frequently aliased Doppler signals and other sources removed. The archived set should be as good or better than the example shown and may occupy only 25 to 50 tapes.

Riddle, A. C.↗

Landsat D Thematic Mapper image dimensionality reduction and geometric correction accuracy

To characterize and quantify the performance of the Landsat thematic mapper (TM), techniques for dimensionality reduction by linear transformation have been studied and evaluated and the accuracy of the correction of geometric errors in TM images analyzed. Theoretical evaluations and comparisons for existing methods for the design of linear transformation for dimensionality reduction are presented. These methods include the discrete Karhunen Loeve (KL) expansion, Multiple Discriminant Analysis (MDA), Thematic Mapper (TM)-Tasseled Cap Linear Transformation and Singular Value Decomposition (SVD). A unified approach to these design problems is presented in which each method involves optimizing an objective function with respect to the linear transformation matrix. From these studies, four modified methods are proposed. They are referred to as the Space Variant Linear Transformation, the KL Transform-MDA hybrid method, and the First and Second Version of the Weighted MDA method. The modifications involve the assignment of weights to classes to achieve improvements in the class conditional probability of error for classes with high weights. Experimental evaluations of the existing and proposed methods have been performed using the six reflective bands of the TM data. It is shown that in terms of probability of classification error and the percentage of the cumulative eigenvalues, the six reflective bands of the TM data require only a three dimensional feature space. It is shown experimentally as well that for the proposed methods, the classes with high weights have improvements in class conditional probability of error estimates as expected.

Ford, G. E.↗

Application of the complex cepstrum to the location of acoustic sources near reflective surfaces

The complex cepstrum is used to correct bearing estimations of acoustic sources in the presence of a reflective surface. An automated liftering procedure is used which zeros out a block portion of the cepstrum including the echo information. The problem of the resulting distortion is alleviated by applying a coherence criterion to the recovered direct signals at each microphone. Thus to a large degree the interactive nature of cepstral processing is overcome for this application. For the test signals and geometries considered the cepstrum is shown to accurately correct for bearing errors in acoustic signals contaminated with reflections from nearby surfaces.

Fuller, C. R.↗

Experiments on thermoacoustic convection heat transfer in gravity and zero-gravity environments

The results of an experimental study of thermoacoustic convection (TAC) heat transfer in gravity and zero-gravity environments are presented. The experimental apparatus consisted of a cylinder containing air as the compressible fluid. The enclosed air was heated electrically at the top surface which consisted of a thin high-resistance steel foil connected to a power source. Thermocouples were used to measure the transient temperature of the air on the axis of the cylinder and the heated surface in the both zero-gravity and gravity environments. The zero-gravity tests were performed in the Zero-Gravity Drop Tower Facility of NASA-Lewis Research Center. The experimental results were corrected for the error due to radiation absorption by the thermocouples. A conduction-only numerical heat transfer model was developed to compute the transient air temperature in the cylindrical geometry. The results were compared to the experimental data to determine the significance of the thermoacoustic convection heat transfer mechanism. It is observed that the rate of heat transfer to the air measured during the experiments is consistently higher than that obtained by the conduction-only solution indicating a significant presence of the TAC heat transfer. Further experiments are planned to measure directly (1) the radiative heat transfer contribution to the rise in the air temperature, and (2) the air pressure oscillations within the cylinder that are responsible for the convective heat transfer mode.