Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors and uncertainties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

Validation of ISCCP cloud detections

This paper describes the validation of the International Satellite Cloud Climatology project (ISCCP)cloud detections by verifying the accuracy of the infrared clear-sky radiances. Comparison of retrieved surface temperatures to other measurements shows that bias errors are less than 2 K and random errors are about 2 K for sea surface (monthly means at 280-km scales) and that bias errors are less than 2 K and random errors are about 4 K for land surfaces (3 hourly at 280-km scales). Bias errors over a few persistently cloudy locations are sometimes -(2-4) K and over winter sea ice may be about +2 K. Surface reflectances are confirmed to be within 3% of other measurements and models for ocean, except for sun glint geometries, and to be within 3%-5% for land surfaces. Sufficiently accurate validation data are not avilable for visible reflectances of sea ice and snow-covered land, but some tests of specific cases suggest that errors are approximately 10%. These errors in clear-sky radiances suggest uncertainties in the ISCCP cloud detections of about 10% with a small (3%-6%) negative bias over land. Some specific regions exhibit both larger rms uncertainties and somewhat larger biases in cloud amount approaching 10%. ISCCP cloud detections are more in error over the polar regions than anywhere else. Based on comparisons with an anlysis of radiances measured at other wavelengths, the ISCCP analysis appears to miss 15%-25% of the clouds in summer but only 5%-10% of the winter clouds.

Rossow, William B.↗

Extended Forward Sensitivity Analysis for Uncertainty Quantification

This paper presents the extended forward sensitivity analysis as a method to help uncertainty qualification. By including time step and potentially spatial step as special sensitivity parameters, the forward sensitivity method is extended as one method to quantify numerical errors. Note that by integrating local truncation errors over the whole system through the forward sensitivity analysis process, the generated time step and spatial step sensitivity information reflect global numerical errors. The discretization errors can be systematically compared against uncertainties due to other physical parameters. This extension makes the forward sensitivity method a much more powerful tool to help uncertainty qualification. By knowing the relative sensitivity of time and space steps with other interested physical parameters, the simulation is allowed to run at optimized time and space steps without affecting the confidence of the physical parameter sensitivity results. The time and space steps forward sensitivity analysis method can also replace the traditional time step and grid convergence study with much less computational cost. Two well-defined benchmark problems with manufactured solutions are utilized to demonstrate the method.

99 GENERAL AND MISCELLANEOUS↗

A uvbyCaHβ analysis of the old open cluster, NGC 6819

NGC 6819 is a richly populated, older open cluster situated within the Kepler field. A CCD survey of the cluster on the uvbyCaHβ system, coupled with proper-motion membership, has been used to isolate 382 highly probable, single-star unevolved main-sequence members over a 20' field centered on the cluster. From 278 F dwarfs with high precision photometry in all indices, a mean reddening of E(b – y) = 0.117 ± 0.005 or E(B – V) = 0.160 ± 0.007 is derived, where the standard errors of the mean include both internal errors and the photometric zero-point uncertainty. With the reddening fixed, the metallicity derived from the same 278 stars is [Fe/H] = –0.116 ± 0.101 from m {sub 1} and –0.055 ± 0.033 from hk, for a weighted average of [Fe/H] = –0.06 ± 0.04, where the quoted standard errors of the mean include the internal errors from the photometric scatter plus the uncertainty in the photometric zero points. If metallicity is derived using individual reddening values for each star to account for potential reddening variation across the face of the cluster, the analogous result is unchanged. The cluster members at the turnoff of the color-magnitude diagram are used to test and confirm the recently discovered variation in reddening across the face of the cluster, with a probable range in the variation of ΔE(B – V) = 0.045 ± 0.015. With the slightly higher reddening and lower [Fe/H] compared to commonly adopted values, isochrone fitting leads to an age of 2.3 ± 0.2 Gyr for an apparent modulus of (m – M) = 12.40 ± 0.12.

79 ASTRONOMY AND ASTROPHYSICS↗

Nucleon momentum fraction, helicity and transversity from 2+1-flavor lattice QCD

A detailed analysis of the systematic uncertainties in the calculation of the isovector momentum fraction, ( x ) u - d , helicity moment, ( x ) Δ u - Δ d , and the transversity moment, ( x ) δu - δd , of the nucleon is presented using high-statistics data on seven ensembles of gauge configurations generated by the JLab/W&M/LANL/MIT collaborations using 2 + 1-flavors of dynamical Wilson-clover quarks. The much higher statistics have facilitated better control over all systematics compared to previous lattice calculations. The least understood systematic — excited-state contamination — is quantified by studying the variation of the results as a function of different estimates of the mass gap of the first excited state, obtained from two- and three-point correlation functions, and as a function of the pion mass M π . The final results are obtained using a simultaneous fit in the lattice spacing a , pion mass M π and the finite volume parameter M π L keeping leading order corrections. The data show no significant dependence on the lattice spacing and some evidence for finite-volume corrections. Our final results, in the $ \overline{\mathrm{MS}} $ scheme at 2 GeV, are ( x ) u - d = 0 . 155(17)(20), ( x ) Δ u - Δ d = 0 . 183(14)(20) and ( x ) δu - δd = 0 . 220(18)(20), where the first error is the overall analysis uncertainty assuming excited-state contributions have been removed, and the second is an additional systematic uncertainty due to possible residual excited-state contributions. These results are consistent with phenomenological global fit values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-BRD-03: Determination of Plan Robustness for Systematic Setup Errors Using Trilinear Interpolation

Purpose: Treatment plan evaluations in radiotherapy are currently ignoring the dosimetric impact of setup uncertainties. The determination of the robustness for systematic errors is rather computational intensive. This work investigates interpolation schemes to quantify the robustness of treatment plans for systematic errors in terms of efficiency and accuracy. Methods: The impact of systematic errors on dose distributions for patient treatment plans is determined by using the Swiss Monte Carlo Plan (SMCP). Errors in all translational directions are considered, ranging from −3 to +3 mm in mm steps. For each systematic error a full MC dose calculation is performed leading to 343 dose calculations, used as benchmarks. The interpolation uses only a subset of the 343 calculations, namely 9, 15 or 27, and determines all dose distributions by trilinear interpolation. This procedure is applied for a prostate and a head and neck case using Volumetric Modulated Arc Therapy with 2 arcs. The relative differences of the dose volume histograms (DVHs) of the target and the organs at risks are compared. Finally, the interpolation schemes are used to compare robustness of 4- versus 2-arcs in the head and neck treatment plan. Results: Relative local differences of the DVHs increase for decreasing number of dose calculations used in the interpolation. The mean deviations are <1%, 3.5% and 6.5% for a subset of 27, 15 and 9 used dose calculations, respectively. Thereby the dose computation times are reduced by factors of 13, 25 and 43, respectively. The comparison of the 4- versus 2-arcs plan shows a decrease in robustness; however, this is outweighed by the dosimetric improvements. Conclusion: The results of this study suggest that the use of trilinear interpolation to determine the robustness of treatment plans can remarkably reduce the number of dose calculations. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SAD phasing of XFEL data depends critically on the error model

A nonlinear least-squares method for refining a parametric expression describing the estimated errors of reflection intensities in serial crystallographic (SX) data is presented. This approach, which is similar to that used in the rotation method of crystallographic data collection at synchrotrons, propagates error estimates from photon-counting statistics to the merged data. Here, it is demonstrated that the application of this approach to SX data provides better SAD phasing ability, enabling the autobuilding of a protein structure that had previously failed to be built. Estimating the error in the merged reflection intensities requires the understanding and propagation of all of the sources of error arising from the measurements. One type of error, which is well understood, is the counting error introduced when the detector counts X-ray photons. Thus, if other types of random errors (such as readout noise) as well as uncertainties in systematic corrections (such as from X-ray attenuation) are completely understood, they can be propagated along with the counting error, as appropriate. In practice, most software packages propagate as much error as they know how to model and then include error-adjustment terms that scale the error estimates until they explain the variance among the measurements. If this is performed carefully, then during SAD phasing likelihood-based approaches can make optimal use of these error estimates, increasing the chance of a successful structure solution. In serial crystallography, SAD phasing has remained challenging, with the few examples of de novo protein structure solution each requiring many thousands of diffraction patterns. Here, the effects of different methods of treating the error estimates are estimated and it is shown that using a parametric approach that includes terms proportional to the known experimental uncertainty, the reflection intensity and the squared reflection intensity to improve the error estimates can allow SAD phasing even from weak zinc anomalous signal.

59 BASIC BIOLOGICAL SCIENCES↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Sensitivity study

Power towers, a type of concentrating power tower technology, use a large number of heliostats to concentrate sunlight and produce renewable energy. Optical errors of heliostats can cause drastic losses in the efficiency of power-tower plants. Accurately measuring optical errors is crucial to assessing and improving plant performance. This analysis discusses an innovate non-intrusive optical (NIO) approach to measure slope, canting, and tracking errors by detecting distortions in the reflected tower structure in heliostat images. Further in this work a sensitivity study is carefully conducted to determine the uncertainty requirements to allow the method to calculate slope errors with an accuracy of 0.25 mrad. Measurement uncertainty sources include camera resolution and position uncertainty, tower position uncertainty, and number of collected images. Each uncertainty source is investigated to determine its impact on the accuracy of the slope-error calculation. A combination of theoretical results and experimental results obtained from data collected on a heliostat at Sandia National Laboratories is used to determine and validate uncertainty requirements. The analysis shows that a measurement uncertainty of 0.25 mrad can be realized by realistically controlling uncertainty sources when implementing the NIO method. It demonstrates the superior performance of NIO in performing in-situ optical characterization.

14 SOLAR ENERGY↗

Tolerance and UQ4SIM: Nimble Uncertainty Documentation and Analysis Software

Ultimately, scientific numerical models need quantified output uncertainties so that modeling can evolve to better match reality. Documenting model input uncertainties and variabilities is a necessary first step toward that goal. Without known input parameter uncertainties, model sensitivities are all one can determine, and without code verification, output uncertainties are simply not reliable. The basic premise of uncertainty markup is to craft a tolerance and tagging mini-language that offers a natural, unobtrusive presentation and does not depend on parsing each type of input file format. Each file is marked up with tolerances and optionally, associated tags that serve to label the parameters and their uncertainties. The evolution of such a language, often called a Domain Specific Language or DSL, is given in [1], but in final form it parallels tolerances specified on an engineering drawing, e.g., 1 +/- 0.5, 5 +/- 10%, 2 +/- 10 where % signifies percent and o signifies order of magnitude. Tags, necessary for error propagation, can be added by placing a quotation-mark-delimited tag after the tolerance, e.g., 0.7 +/- 20% 'T_effective'. In addition, tolerances might have different underlying distributions, e.g., Uniform, Normal, or Triangular, or the tolerances may merely be intervals due to lack of knowledge (uncertainty). Finally, to address pragmatic considerations such as older models that require specific number-field formats, C-style format specifiers can be appended to the tolerance like so, 1.35 +/- 10U_3.2f. As an example of use, consider figure 1, where a chemical reaction input file is has been marked up to include tolerances and tags per table 1. Not only does the technique provide a natural method of specifying tolerances, but it also servers as in situ documentation of model uncertainties. This tolerance language comes with a utility to strip the tolerances (and tags), to provide a path to the nominal model parameter file. And, as shown in [1], having the ability to quickly mark and identify model parameter uncertainties facilitates error propagation, which in turn yield output uncertainties.

Kleb, Bil↗

Observation of B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(980) and Evidence for B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(1370)

We report the observation of B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(980) and evidence for B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(1370), which are CP eigenstate decay modes. These results are obtained from 121.4 fb{sup -1} of data collected at the {Upsilon}(5S) resonance with the Belle detector at the KEKB e{sup +}e{sup -} collider. We measure the branching fractions B(B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(980);f{sub 0}(980){yields}{pi}{sup +}{pi}{sup -})=(1.16{sub -0.19}{sup +0.31}(stat){sub -0.17}{sup +0.15} (syst){sub -0.18}{sup +0.26}(N{sub B{sub s}{sup (*)}}{sub B{sub s}{sup (*)}}))x10{sup -4} with a significance of 8.4{sigma}, and B(B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(1370);f{sub 0}(1370){yields}{pi}{sup +}{pi}{sup -})=(0.34{sub -0.14}{sup +0.11}(stat){sub -0.02}{sup +0.03} (syst){sub -0.05}{sup +0.08} (N{sub B{sub s}{sup (*)}}{sub B{sub s}{sup (*)}}))x10{sup -4} with a significance of 4.2{sigma}. The last error listed is due to uncertainty in the number of produced B{sub s}{sup (*)}B{sub s}{sup (*)} pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interpolation Method Needed for Numerical Uncertainty Analysis of Computational Fluid Dynamics

Using Computational Fluid Dynamics (CFD) to predict a flow field is an approximation to the exact problem and uncertainties exist. There is a method to approximate the errors in CFD via Richardson's Extrapolation. This method is based off of progressive grid refinement. To estimate the errors in an unstructured grid, the analyst must interpolate between at least three grids. This paper describes a study to find an appropriate interpolation scheme that can be used in Richardson's extrapolation or other uncertainty method to approximate errors. Nomenclature

CFD↗

Absolute Timing of the Crab Pulsar with RXTE

We have monitored the phase of the main X-ray pulse of the Crab pulsar with the Rossi X-ray Timing Explorer (RXTE) for almost eight years, since the start of the mission in January 1996. The absolute time of RXTE's clock is sufficiently accurate to allow this phase to be compared directly with the radio profile. Our monitoring observations of the pulsar took place bi-weekly (during the periods when it was at least 30 degrees from the Sun) and we correlated the data with radio timing ephemerides derived from observations made at Jodrell Bank. We have determined the phase of the X-ray main pulse for each observation with a typical error in the individual data points of 50 microseconds. The total ensemble is consistent with a phase that is constant over the monitoring period, with the X-ray pulse leading the radio pulse by 0.01025 plus or minus 0.00120 period in phase, or 344 plus or minus 40 microseconds in time. The error estimate is dominated by a systematic error of 40 microseconds, most likely constant, arising from uncertainties in the instrumental calibration of the radio data. The statistical error is 0.00015 period, or 5 microseconds. The separation of the main pulse and interpulse appears to be unchanging at time scales of a year or less, with an average value of 0.4001 plus or minus 0.0002 period. There is no apparent variation in these values with energy over the 2-30 keV range. The lag between the radio and X-ray pulses ma be constant in phase (i.e., rotational in nature) or constant in time (i.e., due to a pathlength difference). We are not (yet) able to distinguish between these two interpretations.

Rots, Arnold H.↗

Assessment of Current Jet Noise Prediction Capabilities

An assessment was made of the capability of jet noise prediction codes over a broad range of jet flows, with the objective of quantifying current capabilities and identifying areas requiring future research investment. Three separate codes in NASA s possession, representative of two classes of jet noise prediction codes, were evaluated, one empirical and two statistical. The empirical code is the Stone Jet Noise Module (ST2JET) contained within the ANOPP aircraft noise prediction code. It is well documented, and represents the state of the art in semi-empirical acoustic prediction codes where virtual sources are attributed to various aspects of noise generation in each jet. These sources, in combination, predict the spectral directivity of a jet plume. A total of 258 jet noise cases were examined on the ST2JET code, each run requiring only fractions of a second to complete. Two statistical jet noise prediction codes were also evaluated, JeNo v1, and Jet3D. Fewer cases were run for the statistical prediction methods because they require substantially more resources, typically a Reynolds-Averaged Navier-Stokes solution of the jet, volume integration of the source statistical models over the entire plume, and a numerical solution of the governing propagation equation within the jet. In the evaluation process, substantial justification of experimental datasets used in the evaluations was made. In the end, none of the current codes can predict jet noise within experimental uncertainty. The empirical code came within 2dB on a 1/3 octave spectral basis for a wide range of flows. The statistical code Jet3D was within experimental uncertainty at broadside angles for hot supersonic jets, but errors in peak frequency and amplitude put it out of experimental uncertainty at cooler, lower speed conditions. Jet3D did not predict changes in directivity in the downstream angles. The statistical code JeNo,v1 was within experimental uncertainty predicting noise from cold subsonic jets at all angles, but did not predict changes with heating of the jet and did not account for directivity changes at supersonic conditions. Shortcomings addressed here give direction for future work relevant to the statistical-based prediction methods. A full report will be released as a chapter in a NASA publication assessing the state of the art in aircraft noise prediction.

Hunter, Craid A.↗

Accuracy of Pressure Sensitive Paint

Uncertainty in pressure sensitive paint (PSP) measurement is investigated from a standpoint of system modeling. A functional relation between the imaging system output and luminescent emission from PSP is obtained based on studies of radiative energy transports in PSP and photodetector response to luminescence. This relation provides insights into physical origins of various elemental error sources and allows estimate of the total PSP measurement uncertainty contributed by the elemental errors. The elemental errors and their sensitivity coefficients in the error propagation equation are evaluated. Useful formulas are given for the minimum pressure uncertainty that PSP can possibly achieve and the upper bounds of the elemental errors to meet required pressure accuracy. An instructive example of a Joukowsky airfoil in subsonic flows is given to illustrate uncertainty estimates in PSP measurements.

Liu, Tianshu↗

Characterizing Spatiotemporal Uncertainty in Interpolated Meteorological Data

Interpolated meteorological data invariably contain errors. These errors have structure in time and space, particularly autocorrelation, which can cause the effects of errors to compound when model outputs are aggregated temporally or spatially. One way to account for this uncertainty is with a probabilistic model from which samples can be drawn that are coherent with respect to underlying spatial and temporal covariance structure. This work describes a probabilistic method for spatial interpolation of point-wise meteorological time series. Observational data from weather stations are generally sparse in space and dense in time (but sometimes missing). The method works by projecting time series onto orthogonal basis vectors and spatially interpolating each resulting component independently. Under suitable assumptions, and data transformations to better satisfy those assumptions, Gaussian process regression provides a complete description of the joint predictive distribution over a Gaussian random field. Spatiotemporally coherent realizations are generated as the sum of conditional (spatial) simulations of each orthogonal (temporal) component. Data-derived and generic orthogonal bases are considered. In addition to spatial interpolation, imputation of missing observational data is examined. The method is applied using near-surface air temperature over the Western United States and validated by comparing theoretical versus actual coverage of predictive distributions and analyzing the degree to which spatial and temporal covariance structure is reproduced. Computational considerations, relating to conditional simulation of random fields, are also addressed.

Conor T Doherty↗

Spectral Correlation in MODIS Water-Leaving Reflectance Retrieval Uncertainty

Spectral remote sensing reflectance, Rrs(λ) (sr−1), is the fundamental quantity used to derive a host of bio-optical and biogeochemical properties of the water column from satellite ocean color measurements. Estimation of uncertainty in those derived geophysical products is therefore dependent on knowledge of the uncertainty in satellite-retrieved R rs . Furthermore, since the associated algorithms require R rs at multiple spectral bands, the spectral (i.e., band-to-band)error covariance in R rs is needed to accurately estimate the uncertainty in those derived properties. This study establishes a derivative-based approach for propagating instrument random noise, instrument systematic uncertainty, and forward model uncertainty into R rs as retrieved using NASA’s multiple-scattering epsilon (MSEPS) atmospheric correction algorithm, to generate pixel-level error covariance in R rs . The approach is applied to measurements from Moderate Resolution Imaging Spectroradiometer (MODIS) on the Aqua satellite and verified using Monte Carlo (MC) analysis. We also make use of this full spectral error covariance in R rs to calculate uncertainty in phytoplankton pigment chlorophyll-a concentration (chl a , mg/m 3 ) and diffuse attenuation coefficient of downwelling irradiance at 490 nm (K d (490), m -1 ). Accounting for the error covariance in R rs generally reduces the estimated relative uncertainty in chl a by ∼1-2% (absolute value) in waters with chl a < 0.25 mg/m 3 where the color index (CI) algorithm is used. The reduction is ∼5-10% in waters with chl a > 0.35 mg/m 3 where the blue-green ratio (OCX) algorithm is used. Such reduction can be higher than 30% in some regions. For K d (490), the reduction by error covariance is generally ∼2%, but can be higher than 20% in some regions. The error covariance in R rs is further verified through forward-calculating chl a from MODIS-retrieved and in situ R rs and comparing estimated uncertainty with observed differences. An 8-day global composite of propagated uncertainty shows that the goal of 35% uncertainty in chl a can be achieved over deep ocean waters (chl a ≤ 0.1 mg/m3). While the derivative-based approach generates reasonable error covariance in R rs some assumptions should be updated as our knowledge improves. These include the inter-band error correlation in top-of-atmosphere reflectance, and uncertainties in the calibration of MODIS 869 nm band, in ancillary data, and in the in situ data used for system vicarious calibration.

Ocean color↗

THE IDENTIFICATION OF THE X-RAY COUNTERPART TO PSR J2021+4026

We report the probable identification of the X-ray counterpart to the {gamma}-ray pulsar PSR J2021+4026 using imaging with the Chandra X-ray Observatory Advanced CCD Imaging Spectrometer and timing analysis with the Fermi satellite. Given the statistical and systematic errors, the positions determined by both satellites are coincident. The X-ray source position is R.A. 20{sup h}21{sup m}30.{sup s}733, decl. +40 Degree-Sign 26'46.''04 (J2000) with an estimated uncertainty of 1.''3 combined statistical and systematic error. Moreover, both the X-ray to {gamma}-ray and the X-ray to optical flux ratios are sensible assuming a neutron star origin for the X-ray flux. The X-ray source has no cataloged infrared-to-visible counterpart and, through new observations, we set upper limits to its optical emission of i' > 23.0 mag and r' > 25.2 mag. The source exhibits an X-ray spectrum with most likely both a power law and a thermal component. We also report on the X-ray and visible light properties of the 43 other sources detected in our Chandra observation.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface Figure Measurement at 20K: Silicon Carbide and Cesic Mirrors

This report presents the facility, methods, and results of testing cryogenically-cooled spherical mirrors, using standard phase-shifting interferometry, at the Goddard Space Flight Center (GSFC). Two mirrors were supplied to GSFC by the European Space Technology Center, so that GSFC could render a second, independent cryo-measurement of their surface figures at 20K. These mirrors, produced by Galileo Avionica and its partners, demonstrate the technology of silicon carbide and SiC-composite lightweighted mirrors, designed for high accuracy (10 nm rms surface figure error) at both room temperature and 20K. The two mirrors provided for testing at GSFC include one made of sintered silicon carbide (mirror blank by Bettini), and a second made of the C/Si/SiC composite known as Cesic (supplied by ECM). Both mirrors are f/2 spheres with 150 mm clear aperture, and with integral mounts. At GSFC, the mirrors will be measured first at at room temperature, making use of standard techniques, with a predicted uncertainty of 2 nm. Then each mirror will be tested in the cryostat, down to 20K: first freely supported and, second, mounted to a Cesic plate that models a Cesic optical bench. The uncertainty of the resultant surface figure error is predicted to be about 5 nm rms. Details of the uncertainty budget are discussed in a related poster. GSFC's techniques and results can be usefully compared to the measurements performed on the same two mirrors by and for Galileo Avionica, who used a somewhat different test configuration and alignment approach.

Blake, Peter↗