Search NASA⌕ Search

SEARCH · Search NASA

Results for “field protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Broadening of the drumhead-mode spectrum due to in-plane thermal fluctuations of two-dimensional trapped ion crystals in a Penning trap

Two-dimensional crystals of ions stored in Penning traps are a leading platform for quantum simulation and sensing experiments. For small amplitudes, the out-of-plane motion of such crystals can be described by a discrete set of normal modes called the drumhead modes, which can be used to implement a range of quantum information protocols. However, experimental observations of crystals with Doppler-cooled and even nearground- state-cooled drumhead modes reveal an unresolved drumhead-mode spectrum. In this work, we establish in-plane thermal fluctuations in ion positions as a major contributor to the broadening of the drumhead-mode spectrum. In the process, we demonstrate how the confining magnetic field leads to unconventional in-plane normal modes, whose average potential and kinetic energies are not equal. This property, in turn, has implications for the sampling procedure required to choose the in-plane initial conditions for molecular-dynamics simulations. Further, for current operating conditions of the NIST Penning trap, our study suggests that the two-dimensional crystals produced in this trap undergo in-plane potential-energy fluctuations of the order of 10mK. Our study therefore motivates the need for designing improved techniques to cool the in-plane degrees of freedom.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliability Testing Beyond Qualification as a Key Component in Photovoltaic's Progress Toward Grid Parity: Preprint

This paper discusses why it is necessary for new lower cost PV modules to be tested using a reliability test sequence that goes beyond the Qualification test sequence now utilized for modules. Today most PV modules are warranted for 25 years, but the Qualification Test Sequence does not test for 25-year life. There is no accepted test protocol to validate a 25-year lifetime. This paper recommendsthe use of long term accelerated testing to compare now designs directly with older designs that have achieved long lifetimes in outdoor exposure. If the new designs do as well or better than the older ones, then it is likely that they will survive an equivalent length of time in the field.

14 SOLAR ENERGY↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous Electric Loads (MELs) have proliferated in the last decade, and comprise an increasing share of building energy consumption. Because of the diversity of MELs and our lack of understanding about how people use them, large-scale data collection is needed to inform meaningful energy reduction strategies. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. This study assessed the reliability and accuracy of crowdsourced data, by recruiting over 20 volunteers (from the 2012 Lawrence Berkeley Lab, Open House event) to test our crowdsourcing protocol. The protocol asked volunteers to perform the following tasks for three test products with increasing complexity - record power meter and product characteristics, identify all power settings available, and report the measured power. Based on our collected data and analysis, we concluded that volunteers performed reasonably well for devices with functionalities with which they are familiar, and might not produce highly accurate field measurements for complex devices. Accuracy will likely improve when participants are measuring the power used by devices in their home which they know how to operate, by providing more specific instructions including instructional videos. When integrated with existing programs such as the Home Energy Saver tool, crowdsourcing data collection from individual homeowners has the potential to generate a substantial amount of information about MELs energy use in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proceedings of the 10th US/German Workshop on Salt Repository Research Design and Operation. Rev. 1

The 10th US/German Workshop on Salt Repository Research, Design, and Operation was hosted by RESPEC and South Dakota School of Mines & Technology, both located in the Black Hills of South Dakota. Over 60 registered participants representing Germany, United States, the Netherlands, and the United Kingdom availed themselves to excellent facilities on the School of Mines campus. As the 10th annual workshop, this occasion is a milestone of the modern era of collaboration between the US and Germany, which has extended to other countries with potential for radioactive waste disposal in salt. Thrust areas covered in the annual workshops are selected by participants and typically include elements of continuity from year to year. This year's themes included siting, modeling challenges, seal systems and materials, operational safety, and special topics. Two major breakout sessions addressed test sample conditioning and natural closure of salt openings. When the new-generation US/German workshops were conceived, one goal was to identify challenging issues related to salt repository sciences and then conduct open discussions in special breakout sessions. These timely sessions achieve the workshop paradigm and provide in-depth dialogue on important salt repository considerations. In many respects, general themes of these salt repository workshops reflect advances in the scientific basis for nuclear-waste disposal in salt formations and develop naturally as a consequence of unremitting attention largely as a result of the workshop commitment. Technical capabilities in the laboratory and field continue to improve in concert with accumulating experience. Because we are working together, mechanical deformation at the micro-scale can be interpreted at a large scale, which is fundamental to predictive modeling of salt repository evolution. This document records the Proceedings of the 2019 gathering of salt repository nations and has been compiled by RESPEC, demonstrating an adopted protocol in which the host organization creates that year's Proceedings. To assist with organization and compilation, individual chapters are summarized by volunteer subject-matter experts from the participatory audience; these contributors are recognized in the Acknowledgements. All formal presentations are included in this document, thus providing a resource for referencing and many excellent photographic images. Appendices include the agenda, list of participants, abstracts, and presentations. A primary purpose for recording workshop activities is to create and sustain an accessible record of salt repository research. These archives also illustrate transparent development of research areas each year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation of Distributed Energy Resources Management System via Advanced Hardware-in-the-Loop Simulation: Preprint

This paper presents an advanced hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation coordinated across advanced distribution management systems (ADMS), distributed energy management system (DERMS), and DERs. The HIL platform provides realistic laboratory testing, including accurate modeling of the real-world distribution system from a utility partner, real controller (ADMS and DERMs) and power (DERs) hardware, and standard communications protocols. The test results show proper functionalities of the integrated platform and performance of the peak load management of coordinated control systems. Based on the laboratory testing, the utility can set up the same grid automation system to manage DERs to achieve system-level control and operation objectives (e.g., peak load management), thus derisking potential issues (e.g., instability) for field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control: Preprint

This paper validates the effectiveness of an Artificial Intelligence (AI)-driven PV plant control and optimization approach, namely, the Automated Learner for Intermittency Control by Extrapolation (ALICE), in empowering PV plant as a dependable grid reliability service provider. The validation is performed in a realistic laboratory controller-hardware-in-the-loop (CHIL) environment, leveraging accurate PV plant modeling and standard industrial communication protocol. Simulation results, considering both varying weather conditions and active control scenarios, demonstrate the superior performance of ALICE in improving the grid service delivery precision and reducing the over-curtailment compared to a state-of-the-art approach, i.e., reference-control grouping based approach. Such a work could help mitigate risks and provide practical guidance during the field deployment of ALICE, while establishing a standardized testing framework for evaluating various PV active control strategies.

hardware-in-the-loop↗

Screening Metal Halide Perovskite Solar Modules for Premature Field Failures

Developing metal halide perovskite (MHP) photovoltaic (PV) devices into reliable large-area solar modules could accelerate global solar energy deployment. Many MHP devices are susceptible to degradation under light and elevated temperature (LT). Published research on LT testing is limited at the module level, and LT testing has not yet been developed for qualification testing of commercial PV products. This report assesses whether results of LT testing at moderately elevated temperatures correlate with those of field-tested modules from the same batch. Six batches of samples from four manufacturers are assessed. It is shown that modules with a robust package that can maintain over 80% of their peak efficiency during LT testing at 55 °C for 100 h are more likely to retain over 80% of their peak efficiency during outdoor operation for 10 weeks. This finding is a step towards developing a validated test protocol that could be incorporated into a qualification standard for the commercialization of MHP PV technologies.

14 SOLAR ENERGY↗

Kohn–Sham calculations of NMR shifts for paramagnetic 3d metal complexes: protocols, delocalization error, and the curious amide proton shifts of a high-spin iron(ii) macrocycle complex

A theory for the nuclear chemical shifts of molecules in arbitrary spin states is applied to a set of paramagnetic organometallic complexes of 3d metals. Ligand chemical shifts are calculated and analyzed using Kohn–Sham (KS) density functional theory with and without relativistic corrections. The roles of the KS delocalization error, Gaussian-type versus Slater-type basis sets, relativistic effects (scalar and spin–orbit), and zero field splitting (ZFS) are investigated. A strong functional dependence of the chemical shifts is apparent and correlated with the delocalization error. Here, the functional dependence is between one and two orders of magnitude larger than variations of the NMR shifts due the other influences that are investigated. ZFS effects are negligible in the determination of the NMR chemical shifts of the complexes except at very low temperatures. The DFT calculated shifts agree reasonably well with experiment. A 73 ppm difference in the NMR shifts of the two protons in the amide groups of a high-spin Fe(II) macrocycle complex arises from selective O → Fe dative bonding that only involves the transfer of β spin density, along with orbital delocalization throughout the ligand bonding framework which electronically couples the coordinating oxygen lone pair orbitals directly to the amide trans proton.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory and Field Testing of Commercially Available Detectors for the Identification of Chemicals of Interest in the Nuclear Fuel Cycle for the Detection of Undeclared Activities

Traditionally, IAEA inspectors have focused on the detection of nuclear indicators as part of infield inspection activities. The ability to rapidly detect and identify chemical as well as nuclear signatures can increase the ability of IAEA inspectors to detect undeclared activities at a site. Identification of chemical indicators have been limited to use in the analysis of environmental samples. Although IAEA analytical laboratories are highly effective, environmental sample processing does not allow for immediate or real-time results to an IAEA inspector at a facility. During a complementary access inspection, under the Additional Protocol, the use of fieldable technologies that can quickly provide accurate information on chemicals that may be indicative of undeclared activities can increase the ability of IAEA to effectively and efficiently complete their mission. The Complementary Access Working Group (CAWG) is a multi-laboratory team with members from Brookhaven National Laboratory, Idaho National Laboratory, Los Alamos National Laboratory, and Sandia National Laboratory. The team identified chemicals at each stage of the nuclear fuel cycle that may provide IAEA inspectors with indications that proliferation activities may be occurring. The group eliminated all indicators related to equipment, technology and training, developing a list of by-products/effluents, non-nuclear materials, nuclear materials, and other observables. These proliferation indicators were prioritized based on detectability from a conduct of operations (CONOPS) perspective of a CA inspection (for example, whether an inspector actually can access the S&O or whether it is in process with no physical access), and the IAEA’s interest in the detection technology in conjunction with radiation detectors. The list was consolidated to general categories (nuclear materials from a chemical detection technique, inorganic chemicals, organic chemicals, halogens, and miscellaneous materials). The team then identified commercial off the shelf (COTS) chemical detectors that may detect the chemicals of interest. Three chemical detectors were selected and tested both in laboratory settings and in field operations settings at Idaho National Laboratory. The instruments selected are: Thermo Scientific TruDefender FT (FTIR), Thermo Scientific FirstDefender RM (Raman), and Bruker Tracer III SD (XRF). Functional specifications, operability, and chemical detectability, selectivity, and limits of detection were determined. Results from the laboratory and field tests will be presented. This work is supported by the Next Generation Safeguards Initiative, Office of Nonproliferation and International Security, National Nuclear Security Administration.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigation of Path Dependence in Commercial Li-ion Cells Chosen for PHEV Duty Cycle Protocols (paper)

Path dependence is emerging as a premier issue of how electrochemical cells age in conditions that are diverse and variable in the time domain. For example, lithium-ion cells in a vehicle configuration will experience a variable combination of usage and rest periods over a range of temperature and state of charge (SOC). This is complicated by the fact that some aging can actually become worse (or better) when a lithium-ion cell is idle for extended periods under calendar-life (calL) aging, as opposed to cycle-life (cycL) conditions where the cell is used within a predictable schedule. The purpose of this study is to bridge the gap between highly idealized and controlled laboratory test conditions and actual field conditions regarding PHEV applications, so that field-type aging mechanisms can be mimicked and quantified in a repeatable laboratory setting. The main parameters are the magnitude and frequency of the thermal cycling, looking at isothermal, mild, and severe scenarios. To date, little is known about Li-ion aging effects caused by thermal cycling superimposed onto electrochemical cycling, and related path dependence. This scenario is representative of what Li-ion batteries will experience in vehicle service, where upon the typical start of a HEV/PHEV, the batteries will be cool or cold, will gradually warm up to normal temperature and operate there for a time, then will cool down after the vehicle is turned off. Such thermal cycling will occur thousands of times during the projected life of a HEV/PHEV battery pack. We propose to quantify the effects of thermal cycling on Li-ion batteries using a representative chemistry that is commercially available. The secondary Li-ion cells used in this study are of the 18650 configuration, have a nominal capacity rating of 1.9 Ah, and consist of a {LiMn2O4 + LiMn(1/3)Ni(1/3)Co(1/3)O2} cathode and a graphite anode. Electrochemical cycling is based on PHEV-relevant cycle-life protocols that are a combination of charge depleting (CD) and charge sustaining (CS) modes discussed in the Battery Test Manual for Plug-in Hybrid Electric Vehicles (INL, March 2008, rev0). A realistic duty cycle will involve both CD and CS modes, the proportion of each defined by the severity of the power demands. We assume that the cells will start each cycling day at 90% SOC, and that they will not be allowed to go below 35% SOC, with operation around 70% SOC being a nominal condition. The 35, 70, and 90% SOC conditions are also being used to define critical aspects of the related reference performance test (RPT) for this investigation. There are three primary components to the RPT, all assessed at room temperature: (A) static and residual capacity (SRC) over a matrix of current, (B) kinetics and pulse performance testing (PPT) over current for SOCs of interest, and (C) EIS for SOCs of interest. The RPT is performed on all cells every 30 day test interval, as well as a pulse-per-day to provide a quick diagnostic snapshot. Where feasible, we utilize various elements of Diagnostic Testing (DT) to characterize performance of the cells and to gain mechanistic-level knowledge regarding both performance features and limitations. We will present the rationale behind the experimental design, early data, and discuss the fundamental tools used to elucidate performance degradation mechanisms.

25 ENERGY STORAGE↗

Importance of Dose Settings in the X-Ray Systems Used for Interventional Radiology: A National Survey

The purpose of this work was to investigate the differences in dose settings among the X-ray units involved in a national survey of patient doses in interventional radiology (IR). The survey was promoted by the National Society of IR and involved 10 centers. As part of the agreed quality control for the survey, entrance doses were measured in a 20-cm-thick acrylic phantom simulating a medium-sized patient. A standard digital subtraction angiography (DSA) imaging protocol for the abdomen was used at the different centers. The center of the phantom was placed at the isocenter of the C-arm system during the measurements to simulate clinical conditions. Units with image intensifiers and flat detectors were involved in the survey. Entrance doses for low, medium, and high fluoroscopy modes and DSA acquisitions were measured for a field of view of 20 cm (or closest). A widespread range of entrance dose values was obtained: 4.5-18.6, 9.2-28.4, and 15.4-51.5 mGy/min in low, medium, and high fluoroscopy mode, respectively, and 0.7-5.0 mGy/DSA image. The ratios between the maximum and the minimum values measured (3-4 for fluoroscopy and 7 for DSA) suggest an important margin for optimization. The calibration factor for the dose-area product meter was also included in the survey and resulted in a mean value of 0.73, with a standard deviation of 0.07. It seems clear that the dose setting for the X-ray systems used in IR requires better criteria and approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suspended InAs Nanowire-Based Devices for Thermal Conductivity Measurement Using the 3ω Method

We demonstrated device architectures implementing suspended InAs nanowires for thermal conductivity measurements. To this aim, we exploited a fabrication protocol involving the use of a sacrificial layer. The relatively large aspect ratio of our nanostructures combined with their low electrical resistance allows to exploit the four-probe 3ω technique to measure the thermal conductivity, inducing electrical self-heating in the nanowire at frequency ω and measuring the voltage drop across the nanostructure at frequency 3ω. In our systems, field effect modulation of the transport properties can be achieved exploiting fabricated side-gate electrodes in combination with the SiO{sub 2}/Si ++ substrate acting as a back gate. Our device architectures can open new routes to the all-electrical investigation of thermal parameters in III-V semiconductor nanowires, with a potential impact on thermoelectric applications.

36 MATERIALS SCIENCE↗

Microstructural Topology as a Prescriptor for Quantum Coherence: Towards A Unified Framework for Decoherence in Superconducting Qubits

In superconducting quantum circuits, decoherence improvements are frequently obtained through process interventions that simultaneously modify surface chemistry, microstructural topology, and device geometry, leaving mechanistic attribution structurally underdetermined. Predictive materials engineering requires measurable structural statistics to be separated from geometry-dependent coupling coefficients into independently testable factors. We introduce the concept of classical and quantum microstructure. In that context, we formulate a channel-wise separable framework for decoherence in superconducting transmon qubits in which each loss channel is described by a reduced prescriptor. Here, a channel-specific microstructural state variable is determined independently of device geometry, and a geometry-dependent coupling functional is computable from field solutions without reference to surface chemistry. We derive this product form from a spatially resolved kernel representation and establish a perturbative separability criterion that defines the regime where independent variation of the variables is valid. The framework specifies five prescriptor classes for dominant loss pathways in transmon-class devices. Falsifiability is operationalized through a pre-committed 2x2 experimental protocol in which the variables must satisfy independent ratio checks within propagated uncertainty. A Minimum-Dataset Specification standardizes reporting for cross-laboratory inference. Part I establishes the conceptual and mathematical architecture; coordinated experimental validation is reserved for Part II.

Dravid, Vinayak P. [Northwestern U.]↗

Technical Evaluation of Radiation Dose Delivered in Prostate Cancer Patients as Measured by an Implantable MOSFET Dosimeter

Purpose: To perform a comparison of the daily measured dose at depth in tissue with the predicted dose values from treatment plans for 29 prostate cancer patients involved in a clinical trial. Methods and Materials: Patients from three clinical sites were implanted with one or two dosimeters in or near the prostatic capsule. The implantable device, known as the DVS, is based on a metal-oxide-semiconductor field effect transistor (MOSFET) detector. A portable telemetric readout system couples to the dosimeter antenna (visible on kilovoltage, computed tomography, and ultrasonography) for data transfer. The predicted dose values were determined by the location of the MOSFET on the treatment planning computed tomography scan. Serial computed tomography images were taken every 2 weeks to evaluate any migration of the device. The clinical protocol did not permit alteration of the treatment parameters using the dosimeter readings. For some patients, one of several image-guided radiotherapy (RT) modalities was used for target localization. Results: The evaluation of dose discrepancy showed that in many patients the standard deviation exceeded the previous values obtained for the dosimeter in a phantom. In some patients, the cumulative dose disagreed with the planned dose by {>=}5%. The data presented suggest that an implantable dosimeter can help identify dose discrepancies (random or systematic) for patients treated with external beam RT and could be used as a daily treatment verification tool for image-guided RT and adaptive RT. Conclusion: The results of our study have shown that knowledge of the dose delivered per fraction can potentially prevent over- or under-dosage to the treatment area and increase the accuracy of RT. The implantable dosimeter could also be used as a localizer for image-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid mapping of polarization switching through complete information acquisition

Polarization switching in ferroelectric and multiferroic materials underpins a broad range of current and emergent applications, ranging from random access memories to field-effect transistors, and tunnelling devices. Switching in these materials is exquisitely sensitive to local defects and microstructure on the nanometre scale, necessitating spatially resolved high-resolution studies of these phenomena. Classical piezoresponse force microscopy and spectroscopy, although providing necessary spatial resolution, are fundamentally limited in data acquisition rates and energy resolution. This limitation stems from their two-tiered measurement protocol that combines slow (~1 s) switching and fast (~10 kHz–1 MHz) detection waveforms. Here we develop an approach for rapid probing of ferroelectric switching using direct strain detection of material response to probe bias. This approach, facilitated by high-sensitivity electronics and adaptive filtering, enables spectroscopic imaging at a rate 3,504 times faster the current state of the art, achieving high-veracity imaging of polarization dynamics in complex microstructures.

36 MATERIALS SCIENCE↗

Observed and model-calculated NO2/NO ratios in tropospheric air sampled during the NASA GTE/CITE-2 field study

Airborne measurements of NO2/NO ratios in the free troposphere, obtained using two-photon LIF (TP-LIF) and chemiluminescence (CL) detectors during the NASA Global Tropospheric Experiment Chemical Instrumentation Test and Evaluation 2 (CITE 2) program in summer 1986, are analyzed and compared with the predictions of a photochemical model. The derivation of the model is outlined, with an emphasis on the role of peroxy radicals in the fast photochemical cycling of NO and NO2 and the production of O3; the CITE 2 instruments and flight protocols are described; and the results are presented in extensive tables and graphs and discussed in detail. It was found that on three CITE 2 flights the CL data were systematically greater than the TP-LIF data; when these data were removed, the averaged values of the two instruments agreed to within 1 percent. The NO2/NO ratios predicted by the model are shown to be consistent with the measurements, although usually 20-25 percent lower.

Chameides, W. L.↗

Potential-induced degradation of Cu(In,Ga)Se 2 can occur by shunting the front i-ZnO and by damaging the p-n junction

In this work we test field-relevant potential-induced degradation (PID) behavior by encapsulating laboratory Cu(In,Ga)Se 2 (CIGS) solar cells and applying +1000 V uniformly on the face of the front glass. In this configuration, we find that K-rich borosilicate glass reduces the extent of PID relative to Na-rich soda-lime glass. We also find that the standard testing protocol of stressing cells at short-circuit leads to faster PID than stressing cells at open-circuit. We characterize two types of CIGS PID: The first, front shunting PID, is driven by front-glass stress and occurs when alkali metal cations accumulate in the i-ZnO buffer, where they increase shunt conductance to reduce fill factor. The second, p-n junction PID, results from back-glass stress as alkali metal cations pile up near the CIGS surface/CdS buffer, where they reduce charge carrier concentration, open-circuit voltage, and fill factor to degrade efficiency ~160 times faster than front shunting PID.

14 SOLAR ENERGY↗

Microscopically based energy density functionals for nuclei using the density matrix expansion. II. Full optimization and validation

Background: Energy density functional methods provide a generic framework to compute properties of atomic nuclei starting from models of nuclear potentials and the rules of quantum mechanics. Until now, the overwhelming majority of functionals have been constructed either from empirical nuclear potentials such as the Skyrme or Gogny forces, or from systematic gradient-like expansions in the spirit of the density functional theory for atoms. Purpose: In this study, we seek to obtain a usable form of the nuclear energy density functional that is rooted in the modern theory of nuclear forces. We thus consider a functional obtained from the density matrix expansion of local nuclear potentials from chiral effective field theory. We propose a parametrization of this functional carefully calibrated and validated on selected ground-state properties that is suitable for large-scale calculations of nuclear properties. Methods: Our energy functional comprises two main components. The first component is a non-local functional of the density and corresponds to the direct part (Hartree term) of the expectation value of local chiral potentials on a Slater determinant. Contributions to the mean field and the energy of this term are computed by expanding the spatial, finite-range components of the chiral potential onto Gaussian functions. The second component is a local functional of the density and is obtained by applying the density matrix expansion to the exchange part (Fock term) of the expectation value of the local chiral potential. We apply the UNEDF2 optimization protocol to determine the coupling constants of this energy functional. Results: We obtain a set of microscopically constrained functionals for local chiral potentials from leading order up to next-to-next-to-leading order with and without three-body forces and contributions from Δ excitations. These functionals are validated on the calculation of nuclear and neutron matter, nuclear mass tables, single-particle shell structure in closed-shell nuclei, and the fission barrier of 240 Pu . Quantitatively, they perform noticeably better than the more phenomenological Skyrme functionals. Conclusions: The inclusion of higher-order terms in the chiral perturbation expansion seems to produce a systematic improvement in predicting nuclear binding energies while the impact on other observables is not really significant. In conclusion, this result is especially promising since all the fits have been performed at the single-reference level of the energy density functional approach, where important collective correlations such as center-of-mass correction, rotational correction, or zero-point vibrational energies have not been taken into account yet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗