Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Macquarie Island Cloud and Radiation Experiment (MICRE) Ice Nucleating Particle Measurements Field Campaign Report

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Macquarie Island Cloud and Radiation Experiment (MICRE) Ice Nucleating Particle Measurements campaign was aligned as a supplemental activity with the second year of the overall MICRE campaign. The purpose of the supplemental campaign was to provide a first-ever annual cycle of ice nucleating particle (INP) measurements at a Southern Ocean (SO) site, toward the investigation/characterization of sources of INPs in the marine boundary layer as being from the production or primary sea spray aerosol (SSA) emissions versus other long-range transport influences. Furthermore, measuring the variability in INPs seasonally in this region, as this may relate to meteorology and ocean biological processes, is expected to help constrain (via parameterizations) numerical model simulations of cloud phase and regional climate. In concert with other SO studies during the time frame of the campaign (March 2017 to March 2018), MICRE sought to evaluate the hypotheses that SSA INPs represent the major INP source in the SO and, due to their generally less efficient INP activation properties compared to terrestrial sources, that they may directly influence the persistence of supercooled clouds in a unique manner for this climatic region. These measurements supplemented the original deployment of primarily radiation measurements provided in the ARM MICRE request and the associated Australian Antarctic Division (AAD) Antarctic Clouds and Radiation Experiment (ACRE). Assistance and collaboration was obtained from the AAD, the Commonwealth Scientific and Industrial Research Organization (CSIRO) and the Australian Bureau of Meteorology (BOM). Follow-up plans will include investigations with their additional aerosol, cloud, and radiative transfer measurements. AAD also saw to the transport to Australia and storage of filters at the end of the campaign. The added effort involved an average of twice-weekly collections (a 48-hour and a 72-hour collection) of pre-sterilized, open-faced, polycarbonate filter samples for post-processing of INP number concentrations and tests to analyze the nature of INP sources. Collections were made by AAD technician Emry Thaggard Crocker after online training from our team. Images of the filter sampler and site are shown in Figure 1. Sampling occurred from an approximate elevation of 4m MSL. Filters were returned frozen to Colorado State University (CSU) at the end of the campaign. Initial processing to obtain INP temperature spectra (0 to -28°C) of the concentrations of INPs active via the immersion freezing mechanism were conducted using the CSU ice spectrometer (IS) instrument systems (Hiranuma et al. 2015; McCluskey et al. 2018). In this method, particles are first removed from filters using ultrapure water while under mechanical agitation. Arrays of the particle suspensions from a portion of filter rinses are then cooled to obtain immersion freezing data per volume of water, and finally are related to sampling volumes to obtain numbers per volume of air following the analysis methods of Vali (1971). A total of 103 filters were collected, including blanks at selected intervals throughout the project. For archival and completion of tasks under this ARM proposal, nearly half of the filter collections (46) were processed for basic temperature spectra, and half of these (23) were also tested for microbial/proteinaceous contributions toward INPs via 95°C pre-treatment of portions of the original suspensions.

Southern Ocean, aerosols, marine clouds, MARCUS ca↗

Comparison of High-Order and Low-Order Methods for Large-Eddy Simulation of a Compressible Shear Layer

The objective of this work is to compare a high-order solver with a low-order solver for performing Large-Eddy Simulations (LES) of a compressible mixing layer. The high-order method is the Wave-Resolving LES (WRLES) solver employing a Dispersion Relation Preserving (DRP) scheme. The low-order solver is the Wind-US code, which employs the second-order Roe Physical scheme. Both solvers are used to perform LES of the turbulent mixing between two supersonic streams at a convective Mach number of 0.46. The high-order and low-order methods are evaluated at two different levels of grid resolution. For a fine grid resolution, the low-order method produces a very similar solution to the highorder method. At this fine resolution the effects of numerical scheme, subgrid scale modeling, and filtering were found to be negligible. Both methods predict turbulent stresses that are in reasonable agreement with experimental data. However, when the grid resolution is coarsened, the difference between the two solvers becomes apparent. The low-order method deviates from experimental results when the resolution is no longer adequate. The high-order DRP solution shows minimal grid dependence. The effects of subgrid scale modeling and spatial filtering were found to be negligible at both resolutions. For the high-order solver on the fine mesh, a parametric study of the spanwise width was conducted to determine its effect on solution accuracy. An insufficient spanwise width was found to impose an artificial spanwise mode and limit the resolved spanwise modes. We estimate that the spanwise depth needs to be 2.5 times larger than the largest coherent structures to capture the largest spanwise mode and accurately predict turbulent mixing.

large eddy simulations↗

Comparison of High-Order and Low-Order Methods for Large-Eddy Simulation of a Compressible Shear Layer

The objective of this work is to compare a high-order solver with a low-order solver for performing large-eddy simulations (LES) of a compressible mixing layer. The high-order method is the Wave-Resolving LES (WRLES) solver employing a Dispersion Relation Preserving (DRP) scheme. The low-order solver is the Wind-US code, which employs the second-order Roe Physical scheme. Both solvers are used to perform LES of the turbulent mixing between two supersonic streams at a convective Mach number of 0.46. The high-order and low-order methods are evaluated at two different levels of grid resolution. For a fine grid resolution, the low-order method produces a very similar solution to the high-order method. At this fine resolution the effects of numerical scheme, subgrid scale modeling, and filtering were found to be negligible. Both methods predict turbulent stresses that are in reasonable agreement with experimental data. However, when the grid resolution is coarsened, the difference between the two solvers becomes apparent. The low-order method deviates from experimental results when the resolution is no longer adequate. The high-order DRP solution shows minimal grid dependence. The effects of subgrid scale modeling and spatial filtering were found to be negligible at both resolutions. For the high-order solver on the fine mesh, a parametric study of the spanwise width was conducted to determine its effect on solution accuracy. An insufficient spanwise width was found to impose an artificial spanwise mode and limit the resolved spanwise modes. We estimate that the spanwise depth needs to be 2.5 times larger than the largest coherent structures to capture the largest spanwise mode and accurately predict turbulent mixing.

large eddy simulations↗

Assessing methods in fusion and fitting for time series construction in remote sensing-based earth observations

This study evaluates the comparative performance of spatiotemporal fusion and time-series fitting methods for constructing high-spatiotemporal-resolution remote sensing time-series data. Due to in-class similarity of fusion methods and fitting methods, we employ the Fit-FC (Fitting, spatial Filtering, and residual Compensation) model as a representative fusion method and the linear harmonic fitting model as a representative fitting method. Both Fit-FC and the linear harmonic fitting are widely used for high-spatiotemporal-resolution time-series data construction, and we modify the original Fit-FC model to enable automatic time-series fusion. To ensure data representativeness, we use 3 years (2019–2021) of Harmonized Landsat and Sentinel-2 surface reflectance datasets and Terra MCD43A4 products. Eight experimental regions are selected worldwide to guarantee generalization of the comparative performance between fusion and fitting methods, covering diverse land-use types (cropland, developed land, forest, and grassland) and varying climatological conditions. Time-series of NDVI and surface reflectance are analyzed under both actual observations and simulated data-missing scenarios. The constructed time-series data reveals that (1) the modified Fit-FC and linear harmonic fitting model achieve excellent performance in constructing high-resolution time-series images; (2) the fusion method outperforms the fitting method in constructing time-series of NDVI and surface reflectance images in cropland-, forest-, and grassland-dominated regions; (3) both methods achieve comparable performance in developed-dominated regions; (4) the fusion method is more robust to missing data, and better captures abrupt phenological transitions under conditions of continuous missing data; (5) the fitting method is computationally more efficient, making it suitable for large-scale time-series image reconstruction. This study provides valuable insights for selecting optimal strategies to generate high-resolution time-series images across diverse application scenarios and lays a foundation for extensions to other vegetation indices or land surface variables.

54 ENVIRONMENTAL SCIENCES↗

Electrochemical ion separation in molten salts

A purification method that uses ion-selective ceramics to electrochemically filter waste products from a molten salt. The electrochemical method uses ion-conducting ceramics that are selective for the molten salt cations desired in the final purified melt, and selective against any contaminant ions. The method can be integrated into a slightly modified version of the electrochemical framework currently used in pyroprocessing of nuclear wastes.

36 MATERIALS SCIENCE↗

Advancement of Systems Designs and Key Engineering Technologies for Materials Based Hydrogen Storage

UTRC lead the development of the Simulink Framework model that enables a comparison of different hydrogen storage systems on a common basis. The Simulink Framework model was disseminated on the www.HSECoE.org website that is hosted by NREL. UTRC contributed to a better understanding of the safety aspects of the proposed hydrogen storage systems. UTRC also participated in the Failure Mode and Effect Analysis of both the chemical- and the adsorbent-based hydrogen storage system during Phase 2 of the Hydrogen Storage Engineering Center of Excellence. UTRC designed a hydrogen storage system with a reversible metal hydride material in a compacted form for light-duty vehicles with a 5.6 kg H2 storage capacity, giving it a 300 miles range. It contains a heat exchanger that enables efficient cooling of the metal hydride material during hydrogen absorption in order to meet the 3.3 minute refueling time target. It has been shown through computation that the kinetics of hydrogen absorption of Ti-catalyzed NaAlH4 was ultimately limiting the rate of hydrogen absorption to 85% of the material capacity in 3.3 minutes. An inverse analysis was performed in order to determine the material property requirements in order for a metal hydride based hydrogen storage system to meet the DOE targets. Work on metal hydride storage systems was halted after the Phase 1 to Phase 2 review due to the lack of metal hydride materials with the required material properties. UTRC contributed to the design of a chemical hydrogen storage system by developing an adsorbent for removing the impurity ammonia from the hydrogen gas, by developing a system to meter the transport of Ammonia Borane (AB) powder to a thermolysis reactor, and by developing a gas-liquid-separator (GLS) for the separation of hydrogen gas from AB slurry in silicone oil. Stripping impurities from hydrogen gas is essential for a long life of the fuel cell system on board of a vehicle. Work on solid transport of AB was halted after the Phase 1 to Phase 2 review in favor of studying the slurry-form of AB as it appeared to be difficult to transport a solid form of AB through the thermolysis reactor. UTRC demonstrated the operation of a compact GLS in the laboratory at a scale that would be required for the actual automotive application. The GLS met the targets for weight and volume. UTRC also reported about the unresolved issue associated with the high vapor pressure of fluids that could be used for making a slurry-form of AB. Work on the GLS was halted after the Phase 2 to Phase 3 review as the off-board regeneration efficiency of the spent AB was below the DOE target of 60%. UTRC contributed to the design of an adsorbent-based hydrogen storage system through measurements of the thermal conductivity of a compacted form of Metal Organic Framework (MOF) number 5 and through the development and sizing of a particulate filter. Thermal conductivity is important for the design of the modular adsorbent tank insert (MATI), as developed by Oregon State University (OSU), in order to enable a rapid refueling process. Stringent hydrogen quality requirements can only be met with an efficient particulate filtration system. UTRC developed a method to size the particulate filter by taking into account the effect of the pressure drop on the hydrogen adsorption process in the tank. UTRC raised awareness about the potential use of materials-based H2 storage systems in applications outside the traditional light-duty vehicle market segment by presenting at several conferences about niche application opportunities in Unmanned Aerial Vehicles (UAV), Autonomous Underwater Vehicles (AUV), portable power and others.

08 HYDROGEN↗

Analysis of Doppler lidar wind measurements

New analysis methods were developed and refined for the synthesis of wind fields from multiple Doppler radar data. Considerable software was written and debugged for wind field synthesis. The analysis methods were applied to radar data collected during the CCOPE experiment in which lidar wind measurements were also made. The analysis method differs from existing methods in that interpolation (using filters with assigned weights) and advection of data, to account for time differential between data acquisition at different points, are not used. Instead, functional fits were used in space and time coordinates to transfer radial velocity data to a space-time grid. Subsequently the wind synthesis is performed. This method gives better space resolution in the synthesized winds, compared to other methods in common use, by better preserving the gradients of velocities. The wind fields show the cellular structure characteristic of boundary-layer convection. Also evident in the analysis are the sharp transitions and gradients in the wind field which were preserved by the synthesis.

Srivastava, R. C.↗

Focus optimization at relativistic intensity with high numerical aperture and adaptive optics

Improved focusing of laser beams using high numerical aperture systems is an efficient route to increasing intensities in the ultrafast regime to relativistic levels. We experimentally demonstrate a new method of optimizing the focus of a high-power laser, using second harmonic generation at full intensity in a low-pressure gas to provide a figure of merit for optimizing the shape of a deformable mirror via a genetic algorithm. Nonlinear and thermal aberrations are corrected, and aberrations introduced by filters are avoided. Furthermore, the method is applied to focus a millijoule, short pulse (30 fs), high repetition rate laser system to relativistic intensity in both near IR and mid IR regimes.

Lin, Jinpu↗

Electrochemical state and internal variables estimation using a reduced-order physics-based model of a lithium-ion cell and an extended Kalman filter

This paper addresses the problem of estimating the present value of electrochemical internal variables in a lithium-ion cell in real time, using readily available measurements of cell voltage, current, and temperature. The variables that can be estimated include any desired set of reaction flux and solid and electrolyte potentials and concentrations at any set of one-dimensional spatial locations, in addition to more standard quantities such as state of charge. The method uses an extended Kalman filter along with a one-dimensional physics-based reduced-order model of cell dynamics. Simulations show excellent and robust predictions having dependable error bounds for most internal variables. (C) 2014 Elsevier B.V. All rights reserved.

Stetzel, KD↗

A novel adaptive discrete cosine transform-domain filter for gap-inpainting of high resolution PET scanners

Purpose: Several positron emission tomography (PET) scanners with special detector block arrangements have been developed in recent years to improve the resolution of PET images. However, the discontinuous detector blocks cause gaps in the sinogram. This study proposes an adaptive discrete cosine transform-based (aDCT) filter for gap-inpainting. Methods: The gap-corrupted sinogram was morphologically closed and subsequently converted to the DCT domain. A certain number of the largest coefficients in the DCT spectrum were identified to determine the low-frequency preservation region. The weighting factors for the remaining coefficients were determined by an exponential weighting function. The aDCT filter was constructed and applied to two digital phantoms and a simulated phantom introduced with various levels of noise. Results: For the Shepp-Logan head phantom, the aDCT filter filled the gaps effectively. For the Jaszczak phantom, no secondary artifacts were induced after aDCT filtering. The percent mean square error and mean structure similarity of the aDCT filter were superior to those of the DCT2 filter at all noise levels. For the simulated striatal dopamine innervation study, the aDCT filter recovered the shape of the striatum and restored the striatum to reference activity ratios to the ideal value. Conclusions: The proposed aDCT filter can recover the missing gap data in the sinogram and improve the image quality and quantitative accuracy of PET images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of Large-Scale Wind Field Characteristics Using Supervisory Control and Data Acquisition Measurements

As the wind energy industry continues to push for increased power production and lower cost of energy, the focus of research has expanded from individual turbines to entire wind farms. Among a host of interesting problems to be solved when considering the wind farm as a whole, we consider the challenge of scalar field estimation, based on information already collected at the individual turbine level. We aim to estimate the large-scale, low-frequency characteristics of the wind field, such as the mean wind direction and the overall decrease in wind speed across the farm, and employ a Kalman filter that models the wind field using a polynomial function. We compare the proposed method’s performance to both a simple averaging technique and filtering of individual turbine measurements. The method presented is not limited to wind turbines and is applicable in other situations where multiple remote agents are used to estimate a scalar field.

estimation↗

Advanced Benchmarking for Complex Building Types: Laboratories as an Exemplar

Complex buildings such as laboratories, data centers and cleanrooms present particular challenges for energy benchmarking because it is difficult to normalize special requirements such as health and safety in laboratories and reliability (i.e., system redundancy to maintain uptime) in data centers which significantly impact energy use. For example, air change requirements vary widely based on the type of work being performed in each laboratory space. We present methods and tools for energy benchmarking in laboratories, as an exemplar of a complex building type. First, we address whole building energy metrics and normalization parameters. We present empirical methods based on simple data filtering as well as multivariate regression analysis on the Labs21 database. The regression analysis showed lab type, lab-area ratio and occupancy hours to be significant variables. Yet the dataset did not allow analysis of factors such as plug loads and air change rates, both of which are critical to lab energy use. The simulation-based method uses an EnergyPlus model to generate a benchmark energy intensity normalized for a wider range of parameters. We suggest that both these methods have complementary strengths and limitations. Second, we present"action-oriented" benchmarking, which extends whole-building benchmarking by utilizing system-level features and metrics such as airflow W/cfm to quickly identify a list of potential efficiency actions which can then be used as the basis for a more detailed audit. While action-oriented benchmarking is not an"audit in a box" and is not intended to provide the same degree of accuracy afforded by an energy audit, we demonstrate how it can be used to focus and prioritize audit activity and track performance at the system level. We conclude with key principles that are more broadly applicable to other complex building types.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mercury Speciation via Direct Mercury Analyzer

Mercury has no known biological role, but is present in every living thing and widespread in the environment. As mercury enters an aqueous system, it is subject to methylation or demethylation. Methylmercury selectively partitions into biota and biomagnifies through the food chain. Nearly all methylmercury exposures in the U.S. occur through eating fish and shellfish that contain higher levels of methylmercury. Methyl mercury and other organomercury compounds are more toxic than inorganic mercury. Thus, monitoring and understanding mercury speciation are key to effective environmental management. It is particularly important to be able to separate and measure bioaccumulative-toxic species of mercury such as methyl mercury. We are developing a protocol for utilizing the Direct Mercury Analyzer (DMA-80) for mercury speciation of water samples and to monitor methylmercury (meHg). Objectives: - Advance the understanding of the performance of the direct mercury analysis (DMA) under a range of DOE relevant water chemistry conditions to quantify total mercury: - Demonstrate the applicability of DMA to analysis of typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Test innovative sorbents to extend the range of the direct mercury analyzer to environmental concentration levels. - Perform scoping tests to demonstrate proof of principle for the chemical reduction amalgamation modular microcolumns for mercury speciation: Examine various microcolumn configurations and document speciation performance for typical DOE high level liquid 'tank' waste samples using nonradioactive simulants; Perform tests to examine extending the speciation paradigm to environmental concentration levels. General Method: all samples analyzed using a direct mercury analyzer (DMA 80) which automates the following steps: 1) pyrolysis to release the mercury, 2) catalysis to convert all mercury to elemental, 3) amalgamation to trap the mercury, 4) desorption to release the mercury as a pulse and 5) spectroscopy to detect the mercury.. Instrument analyzes all mercury species in solids and liquids. The DMA 'eliminates' sample preparation, reduces labor, decreases waste, and results in more practical and cost effective methods. To test the performance of the DMA for DOE relevant conditions, we analyzed samples representative of at high (mg/L) tank waste concentrations in water and in diluted tank waste simulant and analyzed samples representative of environmental (ng/L levels) in water. High concentration samples were analyzed directly in the instrument. Low concentration samples were analyzed by concentrating the mercury onto sorbents such as silica thiol or a mixture of silica thiol and copper. The concentration was performed using microcolumns and placing the columns into the DMA (see below) or by mixing the sorbent into the bulk sample and then filtering ad analyzing the filter in the DMA. Speciation Methods: The speciation tests were based on the selective reduction of inorganic mercury ions - Hg{sup (+} {sup or} {sup 2+)} - to elemental mercury - Hg(0). The elemental mercury is then trapped by amalgamation into the metal. These reactions do not impact methyl mercury allowing for separation. All reactions were performed using powdered elemental copper. To demonstrate proof-of-principle for the selective collection of inorganic mercury, samples were exposed to different amounts of powdered copper (and a control with no copper). This was done using microcolumns and a vacuum box. The columns were placed directly on the DMA for analysis. All materials and conditions were tested using solutions of both inorganic mercury and methyl mercury and all trials were in triplicate. Results and Observations: Validated DMA for high concentration Hg samples such as DOE tank waste: - Liquid inHg - samples were stable on autosampler carousel and results were accurate; - Liquid meHg - samples required a stabilizer. Si-Thiol (0.02 g) in the sample boat generated reliable meHg results. Stabilizer can be added for routine operations. Successful 'proof of principal' in extending DMA range to near environmental levels - using both microcolumns and filtration; - Filtration - Adding Si-Thiol (0.5 g) to sample extracted both inHg and meHg and preserved sample. Handling filters was labor intensive. - Microcolumns - best performance using a combination of copper and Si-Thiol - columns clogged and flowed slowly in some cases; - Practical limit may be in the range of 1 to 5 ng/L due to blanks; - Path Forward - Test additional packing materials and methods to improve flow and consistency, and approaches to minimize blanks. Successful 'proof of principal' for Hg speciation using chemical reduction and amalgamation; - Copper microcolumns (0.5 g Cu) selectively trapped inHg for high concentration mercury samples; - Copper microcolumns (0.5 g Cu selectively trapped inHg for large volume samples at environmental concentrations; - Some sorption of me Hg so that separations not quantitative; - Path Forward - test additional packing materials and alternate eluents to better trap inHg and minimize meHg retention in column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The application of image enhancement techniques to remote manipulator operation

Methods of image enhancement which can be used by an operator who is not experienced with the mechanisms of enhancement to obtain satisfactory results were designed and implemented. Investigation of transformations which operate directly on the image domain resulted in a new technique of contrast enhancement. Transformations on the Fourier transform of the original image, including such techniques as homomorphic filtering, were also investigated. The methods of communication between the enhancement system and the computer operator were analyzed, and a language was developed for use in image enhancement. A working enhancement system was then created, and is included.

Gonzalez, R. C.↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Self-Cleaning Particulate Prefilter Media

A long-term space mission requires efficient air revitalization performance to sustain the crew. Prefilter and particulate air filter media are susceptible to rapid fouling that adversely affects their performance and can lead to catastrophic failure of the air revitalization system, which may result in mission failure. For a long-term voyage, it is impractical to carry replacement particulate prefilter and filter modules due to the usual limitations in size, volume, and weight. The only solution to this problem is to reagentlessly regenerate prefilter and filter media in place. A method was developed to modify the particulate prefilter media to allow them to regenerate reagentlessly, and in place, by the application of modest thermocycled transverse or reversed airflows. The innovation may allow NASA to close the breathing air loop more efficiently, thereby sustaining the vision for manned space exploration missions of the future. A novel, self-cleaning coatings technology was developed for air filter media surfaces that allows reagentless in-place regeneration of the surface. The technology grafts thermoresponsive and nonspecific adhesion minimizing polymer nanolayer brush coatings from the prefilter media. These polymer nanolayer brush architectures can be triggered to contract and expand to generate a "pushing-off" force by the simple application of modestly thermocycled (i.e. cycling from ambient cabin temperature to 40 C) air streams. The nonspecific adhesion-minimizing properties of the coatings do not allow the particulate foulants to adhere strongly to the filter media, and thermocycled air streams applied to the media allow easy detachment and in-place regeneration of the media with minimal impact in system downtime or astronaut involvement in overseeing the process.

Weber, Olivia↗

Design of a Thrust Vector Servoelastic Filter for SLS Block 2 Booster Thrust Vector Control System

This paper presents a method to improve the thrust vector servoelastic (TVSE) response of a launch vehicle. TVSE is the coupling between the Thrust Vector Control (TVC) system nozzle dynamics and the vehicle flexible modes. A poorly phased TVC response, i.e. in phase with the structural velocity, can lead to instability of the flexible modes due to the energy injection from the thrust. For large boosters with heavy nozzles, TVSE is more likely to cause instability. This instability is part of the plant dynamics and may not be readily detected by the flight control system. In this paper, TVSE is treated as a disturbance rejection problem with the inertial force of the flexible motion viewed as an external disturbance to the TVC actuator control system. By effectively rejecting this disturbance, the engine can be decoupled from the flexible dynamics thus improving TVSE stability. The actuator disturbance transfer function is modified by inserting a filter into the servo-loop control system. The filter aims to reduce the magnitude and introduce phase lead of the disturbance transfer function over the TVSE sensitive frequency range while maintaining adequate stability margins of the actuator control system. A prefilter is also designed to improve command tracking performance. The filter and prefilter resulting from this method are usually of low order and can be included to an existing actuator controller if the controller is programmable. This method was demonstrated for a hydraulic Simplex actuator model. Its applications to the Space Launch System (SLS) Block 1 and Block 2 TVC actuator are also described. The Block 2 actuator controller was modified based on the results of this method. The tradeoff between TVSE stability and the servo-loop stability can be balanced by adjusting the amount of phase lead introduced by the TVSE filter. This method provides a useful way to solve the TVSE instability issue without costly and time-consuming hardware solutions. This method is based on the basic control principles of loop shaping and disturbance rejection and has been proven to be effective under proper circumstances.

Thrust vector control↗

Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receive an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗