At least 1,009 records · Page 56

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.↗

Plan for the uniform mapping of earth resources and environmental complexes from Skylab imagery

The author has identified the following significant results. Below approximately 25% cover visual photointerpretation of vegetation analogs of Skylab 2 Sl9OA color infrared imagery is poor. Correct identifications of vegetation analogs in this category range from 28 to 57%. Good photointerpretation results (64 to 96%) were obtained on vegetation analogs with higher cover values. The four semidesert vegetation analogs (greasewood, saltbush, big sagebrush, and pinyon-juniper) are consistently distinguishable as a group. Photointerpretation accuracy equals 90.1%. When these same types are broken into two sub-groups (salt desert vegetation and shrub steppe/sparse pinyon-juniper vegetation) interpretation success drops to 76% and 85%, respectively. Band ratioing and transmittance differences between two forested analogs as imaged on Skylab 2 S19OA film shows significant differences. In the infrared wavelength both analogs have very similar transmittance characteristics while the visible wavelength shows separation between the two. Relative transmittance values for stands of ponderosa pine forestland and pinyon-juniper woodland are 719.3 + or - 65.9 and 223.6 + or - 48.1, respectively on negative transparencies. In image interpretation along the low-elevation fringe of forested regions these are the two forest analogs most frequently requiring separation.

Poulton, C. E.↗

A laser velocimeter system for the Ames 40- by 80-foot and 80by 120-foot wind tunnels

A unique laser velocimeter has been developed that is capable of sensing two orthogonal velocity components from a variable remote distance of 2.6 to 10 m for use in the Ames 40- by 80-Foot and 80- by 120-Foot wind tunnels, as well as in the Ames Outdoor Aerodynamic Research Facility. The system hardware, positioning instrumentation, and data acquisition equipment are described in detail. System capabilities and limitations are discussed, and expressions for systematic and statistical accuracy are developed. Direct and coupled laboratory measurements of a turbulent swirling flow are compared with measurements taken with a laser velocimeter of higher spatial resolution. Sample measurements taken in the open-circuit exhaust flow of the 80- by 120-Foot Wind Tunnel 1/50-scale model are presented.

Reinath, M. S.↗

Environment definition, large particles

The orbital debris environment of objects larger than 1 sq met. in low Earth orbit (LEO) is fairly well defined. Objects of this size and altitude are tracked by NORAD with sufficient accuracy that collisions can be avoided by maneuvering a spacecraft away from regions of close approach. However for sizes smaller and at the higher geosynchrnous altitudes, the environment is not so well defined, and must be approached statistically. In order to determine if a significant number of these particles exist, or can be realistically produced, to cause a problem, a combination of modeling and data gathering is required.

Kessler, D. J.↗

Fabrication Of High-Tc Superconducting Integrated Circuits

Microwave ring resonator fabricated to demonstrate process for fabrication of passive integrated circuits containing high-transition-temperature superconductors. Superconductors increase efficiencies of communication systems, particularly microwave communication systems, by reducing ohmic losses and dispersion of signals. Used to reduce sizes and masses and increase aiming accuracies and tracking speeds of millimeter-wavelength, electronically steerable antennas. High-Tc superconductors preferable for such applications because they operate at higher temperatures than low-Tc superconductors do, therefore, refrigeration systems needed to maintain superconductivity designed smaller and lighter and to consume less power.

Bhasin, Kul B.↗

Comparison of the observed and calculated clear sky greenhouse effect - Implications for climate studies

The clear sky greenhouse effect is defined in terms of the outgoing longwave clear sky flux at the top of the atmosphere. Recently, interest in the magnitude of the clear sky greenhouse effect has increased due to the archiving of the clear sky flux quantity through the Earth Radiation Budget Experiment (ERBE). The present study investigates to what degree of accuracy this flux can be analyzed by using independent atmospheric and surface data in conjunction with a detailed longwave radiation model. The conclusion from this comparison is that for most regions over oceans the analyzed fluxes agree to within the accuracy of the ERBE-retrieved fluxes (+/- 5 W/sq m). However, in regions where deep convective activity occurs, the ERBE fluxes are significantly higher (10-15 W/sq m) than the calculated fluxes. This bias can arise from either cloud contamination problems or variability in water vapor amount. It is argued that the use of analyzed fluxes may provide a more consistent clear sky flux data set for general circulation modeling validation. Climate implications from the analyzed fluxes are explored. Finally, results for obtaining longwave surface fluxes over the oceans are presented.

Kiehl, J. T.↗

Evaluation of a multigrid-based Navier-Stokes solver for aerothermodynamic computations

A multigrid acceleration technique developed for solving the three-dimensional Navier-Stokes equations is used for computing high Mach number flows over configurations of practical interest. An explicit multistage Runge-Kutta type of time-stepping scheme is used as the basic algorithm. Solutions are presented for a spherically blunted cone at Mach 10 and a modified shuttle orbiter at Mach 6. The computed surface heat-transfer distributions are shown to compare favorably with the experimental data. Effect of grid-refinement on computed heat-transfer distributions is also examined to assess the numerical accuracy of the computed solutions. The rapid convergence rate associated with multigrid schemes in previous applications at transonic speeds is observed at the higher Mach number flows investigated here.

Vatsa, Veer N.↗

Time Integration Schemes for the Unsteady Navier-stokes Equations

The efficiency and accuracy of several time integration schemes are investigated for the unsteady Navier-Stokes equations. This study focuses on the efficiency of higher-order Runge-Kutta schemes in comparison with the popular Backward Differencing Formulations. For this comparison an unsteady two-dimensional laminar flow problem is chosen, i.e., flow around a circular cylinder at Re = 1200. It is concluded that for realistic error tolerances (smaller than 10(exp -1)) fourth-and fifth-order Runge-Kutta schemes are the most efficient. For reasons of robustness and computer storage, the fourth-order Runge-Kutta method is recommended. The efficiency of the fourth-order Runge-Kutta scheme exceeds that of second-order Backward Difference Formula by a factor of 2.5 at engineering error tolerance levels (10(exp -1) to 10(exp -2)). Efficiency gains are more dramatic at smaller tolerances.

Bijl, Hester↗

Estimation and Validation of Oceanic Mass Circulation from the GRACE Mission

Since the launch of the Gravity Recovery And Climate Experiment (GRACE) in March 2002, the Earth's surface mass variations have been monitored with unprecedented accuracy and resolution. Compared to the classical spherical harmonic solutions, global high-resolution mascon solutions allows the retrieval of mass variations with higher spatial and temporal sampling (2 degrees and 10 days). We present here the validation of the GRACE global mascon solutions by comparing mass estimates to a set of about 100 ocean bottom pressure (OSP) records, and show that the forward modelling of continental hydrology prior to the inversion of the K-band range rate data allows better estimates of ocean mass variations. We also validate our GRACE results to OSP variations modelled by different state-of-the-art ocean general circulation models, including ECCO (Estimating the Circulation and Climate of the Ocean) and operational and reanalysis from the MERCATOR project.

Boy, J.-P.↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

Assessment of the Accuracy and Consistency of Cloud Property Retrievals from Passive Radiometers with Varying Spectral Information

Over the past few decades, space-based passive radiometers have been used to study the spatial distribution of clouds and some of their basic properties. Modern radiometers have significantly higher spatial resolution and collect more spectral information (i.e., have more spectral bands) than early instruments, and these advances have allowed researchers to characterize cloud physical and microphysical properties with greater detail. There is significant interest in utilizing as much of the existing satellite record as possible to study global and regional changes in cloud occurrence and distribution as well as the associated changes in reflected shortwave and outgoing longwave fluxes. Cloud property retrieval algorithms such as the NASA Satellite Cloud Optical and Radiative Property System (SatCORPS) have traditionally utilized as much spectral information as possible in order to maximize the accuracy of the retrievals. However, changes to the retrieval algorithm over time in order to take advantage of progressively more spectral information results in inconsistencies in cloud properties which in turn results in inconsistencies with products derived from these properties. It is not possible to implement modern state-of-the-art algorithms to earlier instruments which lack diverse spectral information, but many instruments since the early 2000s generally have approximately similar spectral bands in the visible (~0.65 microns), longwave infrared (~11 microns), and in many cases, the midwave infrared (~3.8 microns) and water vapor absorption (~6.7 microns), portions of the electromagnetic spectrum. Different versions of SatCORPS have been implemented with either the full set of spectral information collected by imagers such as GOES-16 and MODIS or with a reduced set of spectral bands in order to be more consistent with past imagers that lack such diverse spectral information. This study uses independent cloud property retrievals from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) to assess the accuracy of the retrievals (e.g., cloud fraction, thermodynamic phase, altitude) from the different retrieval methods and to demonstrate the advantages and disadvantages of using a reduced set of common spectral bands in order to achieve temporal and spatial consistency across different instruments.

Christopher R. Yost↗

On the Feynman-alpha method for reflected fissile assemblies

The Feynman-alpha method is a neutron noise technique that is used to estimate the prompt neutron period of fissile assemblies. The method and quantity are of widespread interest including in applications such as nuclear criticality safety, safeguards and nonproliferation, and stockpile stewardship; the prompt neutron period may also be used to infer the k eff multiplication factor. The Feynman-alpha method is predicated on time-correlated neutron detections that deviate from a Poisson random variable due to multiplication. Traditionally, such measurements are diagnosed with one-region point kinetics, but two-region models are required when the fissile assembly is reflected. This paper presents a derivation of the two-region point kinetics Feynman-alpha equations based on a double integration of the Rossi-alpha equations, develops novel propagation of measurement uncertainty, and validates the theory. Validation is achieved with organic scintillator measurements of weapons-grade plutonium reflected by various amounts of copper to achieve k eff values of 0.83–0.94 and prompt periods of 5–75 ns. The results demonstrate that Feynman-alpha measurements should use the two-region model instead of the one-region model. The simplified one-region model deviates from the validated two-region models by as much as 10% in the estimate of the prompt neutron period, and the two-region model reduces to the one-region model for small amounts of reflector. The Feynman-alpha estimates of the prompt neutron period are compared to those of the Rossi-alpha approach. The comparative results demonstrate that the Feynman-alpha method is more precise than the Rossi-alpha method and more accurate for k eff < 0.92, whereas the Rossi-alpha method is generally more accurate for higher multiplications. Here, the uncertainty propagation developed in this work should be used for all Feynman-alpha measurements and will therein improve fitting accuracy and appropriate precision estimates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Hierarchical median narrow band for level set segmentation of cervical cell nuclei

This paper presents a novel hierarchical nuclei segmentation algorithm for isolated and overlapping cervical cells based on a narrow band level set implementation. Our method applies a new multiscale analysis algorithm to estimate the number of clusters in each image region containing cells, which turns into the input to a narrow band level set algorithm. We assess the nuclei segmentation results on three public cervical cell image databases. Overall, our segmentation method outperformed six state-of-the-art methods concerning the number of correctly segmented nuclei and the Dice coefficient reached values equal to or higher than 0.90. We also carried out classification experiments using features extracted from our segmentation results and the proposed pipeline achieved the highest average accuracy values equal to 0.89 and 0.77 for two-class and three-class problems, respectively. Furthermore, these results demonstrated the suitability of the proposed segmentation algorithm to integrate decision support systems for cervical cell screening.

47 OTHER INSTRUMENTATION↗

Comparison of Equilibrium and Nonequilibrium Approaches for Relative Binding Free Energy Predictions

Alchemical relative binding free energy calculations have recently found important applications in drug optimization. A series of congeneric compounds are generated from a preidentified lead compound, and their relative binding affinities to a protein are assessed in order to optimize candidate drugs. While methods based on equilibrium thermodynamics have been extensively studied, an approach based on nonequilibrium methods has recently been reported together with claims of its superiority. However, these claims pay insufficient attention to the basis and reliability of both methods. Here we report a comparative study of the two approaches across a large data set, comprising more than 500 ligand transformations spanning in excess of 300 ligands binding to a set of 14 diverse protein targets. Ensemble methods are essential to quantify the uncertainty in these calculations, not only for the reasons already established in the equilibrium approach but also to ensure that the nonequilibrium calculations reside within their domain of validity. If and only if ensemble methods are applied, we find that the nonequilibrium method can achieve accuracy and precision comparable to those of the equilibrium approach. Compared to the equilibrium method, the nonequilibrium approach can reduce computational costs but introduces higher computational complexity and longer wall clock times. There are, however, cases where the standard length of a nonequilibrium transition is not sufficient, necessitating a complete rerun of the entire set of transitions. This significantly increases the computational cost and proves to be highly inconvenient during large-scale applications. Our findings provide a key set of recommendations that should be adopted for the reliable implementation of nonequilibrium approaches to relative binding free energy calculations in ligand-protein systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

Image processing pipeline for AI-driven nanoparticle megalibrary characterization

Recent innovations have made it possible to produce megalibraries, millions of structurally and compositionally distinct nanoparticles on a chip. These megalibraries yield vast volumes of data that are impossible to analyze manually, necessitating the development of automated tools. In previous work, we created a binary classification machine learning model to select quality nanoparticle images for downstream analysis. In this work, we show that adding a custom image processing step before training can produce significantly higher-performing models in a fraction of the time and make them more robust to different image noise levels and microscope acquisition settings. The image processing pipeline proposed here effectively cleans raw nanoparticle images, enhances key features, and allows us to use much lower resolution images and simpler neural network model architectures. These features result in higher performance and significant cost savings. Experiments demonstrate superior performance relative to baseline, including an 18.2% improvement in recall and a 13.1% increase in accuracy. Given the high cost of downstream analysis, it is critical to minimize false positives, and our best-performing model reaches a precision of 95.9% and a weighted F-score of 95.1% on an unseen test set. Additionally, model training time is reduced from hours to less than a minute. We also show that, using this custom image processing pipeline, model performance is significantly improved at lower pixel resolutions compared to downsizing alone. We expect that adopting this pipeline for AI-driven automated nanoparticle characterization will allow researchers to rapidly and accurately analyze much greater volumes of data, thereby accelerating materials discovery.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Exploring the S-process History in the Galactic Disk: Cerium Abundances and Gradients in Open Clusters from the OCCAM/APOGEE Sample

The APOGEE Open Cluster Chemical Abundances and Mapping survey is used to probe the chemical evolution of the s-process element cerium in the Galactic disk. Cerium abundances were derived from measurements of Ce ii lines in the APOGEE spectra using the Brussels Automatic Code for Characterizing High Accuracy Spectra in 218 stars belonging to 42 open clusters. Our results indicate that, in general, for ages < 4 Gyr, younger open clusters have higher [Ce/Fe] and [Ce/α-element] ratios than older clusters. In addition, metallicity segregates open clusters in the [Ce/X]–age plane (where X can be H, Fe, or the α-elements O, Mg, Si, or Ca). These metallicity-dependent relations result in [Ce/Fe] and [Ce/α] ratios with ages that are not universal clocks. Radial gradients of [Ce/H] and [Ce/Fe] ratios in open clusters, binned by age, were derived for the first time, with d[Ce/H]/dR GC being negative, while d[Ce/Fe]/dR GC is positive. [Ce/H] and [Ce/Fe] gradients are approximately constant over time, with the [Ce/Fe] gradient becoming slightly steeper, changing by ~+0.009 dex kpc -1 Gyr -1 . Both the [Ce/H] and [Ce/Fe] gradients are shifted to lower values of [Ce/H] and [Ce/Fe] for older open clusters. The chemical pattern of Ce in open clusters across the Galactic disk is discussed within the context of s-process yields from asymptotic giant branch (AGB) stars, gigayear time delays in Ce enrichment of the interstellar medium, and the strong dependence of Ce nucleosynthesis on the metallicity of its AGB stellar sources.

79 ASTRONOMY AND ASTROPHYSICS↗