Interpreting machine learning of topological quantum phase transitions
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The authors describe the structure determination of a hexagonally layered protein structure that suffered from a complicated combination of translational non-crystallographic symmetry and hemihedral twinning. This case serves as a reminder that broken crystallographic symmetry resulting from doubling of a unit-cell axis often requires a new choice of origin. The carboxysome is a giant protein complex that acts as a metabolic organelle in cyanobacteria and some chemoautotrophs. Its outer structure is formed by the assembly of thousands of copies of hexameric shell protein subunits into a molecular layer. The structure determination of a CcmK1 shell protein mutant (L11K) from the β-carboxysome of the cyanobacterium Synechocystis PCC6803 led to challenges in structure determination. Twinning, noncrystallographic symmetry and packing of hexameric units in a special arrangement led to initial difficulties in space-group assignment. The correct space group was clarified after initial model refinement revealed additional symmetry. This study provides an instructive example in which broken symmetry requires a new choice of unit-cell origin in order to identify the highest symmetry space group. An additional observation related to the packing arrangement of molecules in this crystal suggests that these hexameric shell proteins might have lower internal symmetry than previously believed.
The structural information contained in solution scattering data from empty lipid nanodiscs is examined in the context of a multi-component geometric model. X-ray scattering data were collected on nanodiscs of different compositions at scattering vector magnitudes up to 2.0 Å −1 . Through the calculation of the partial form factor for each of the nanodisc components before the isotropic average, structural parameters in the model were correlated to the features observed in the X-ray scattering data and to the corresponding distance distribution function. It is shown that, in general, the features at ∼0.3–0.6 Å −1 in the scattering data correlate to the bilayer structure. The data also support the argument that the elliptical shape of nanodiscs found in model fitting is physical, rather than an artefact due to the nanodisc size distribution. The lipid chain packing peak at ∼1.5 Å −1 is visible in the data and reflects the lipid bilayer phase transition. The shape change in the distance distribution function across the phase transition suggests that the nanodiscs are more circular in the fluid phase. The implication of these findings for model fitting of empty and protein-loaded nanodiscs is discussed.
TLS modelling was developed by Schomaker and Trueblood to describe atomic displacement parameters through concerted (rigid-body) harmonic motions of an atomic group [Schomaker & Trueblood (1968), Acta Cryst. B24, 63–76]. The results of a TLS refinement are T, L and S matrices that provide individual anisotropic atomic displacement parameters (ADPs) for all atoms belonging to the group. These ADPs can be calculated analytically using a formula that relates the elements of the TLS matrices to atomic parameters. Alternatively, ADPs can be obtained numerically from the parameters of concerted atomic motions corresponding to the TLS matrices. Both procedures are expected to produce the same ADP values and therefore can be used to assess the results of TLS refinement. Here, the implementation of this approach in PHENIX is described and several illustrations, including the use of all models from the PDB that have been subjected to TLS refinement, are provided.
The signal processing concept of signal-to-noise ratio (SNR), in its role as a performance measure, is recast within the more general context of information theory, leading to a series of useful insights. Establishing generalized SNR (GSNR) as a rigorous information theoretic measure inherent in any set of observations significantly strengthens its quantitative performance pedigree while simultaneously providing a specific definition under general conditions. This directly leads to consideration of the log likelihood ratio (LLR): first, as the simplest possible information-preserving transformation (i.e., signal processing algorithm) and subsequently, as an absolute, comparable measure of information for any specific observation exemplar. Furthermore, the information accounting methodology that results permits practical use of both GSNR and LLR as diagnostic scalar performance measurements, directly comparable across alternative system/algorithm designs, applicable at any tap point within any processing string, in a form that is also comparable with the inherent performance bounds due to information conservation.
Not Available
Explore the source record for details and available documents.
Cu2ZnSn(S, Se)4 (CZTSe) is an earth-abundant semiconductor with potential for economical thin-film photovoltaic devices. Short minority carrier lifetimes contribute to low open circuit voltage and efficiency. Deep level defects that may contribute to lower minority carrier lifetimes in kesterites have been theoretically predicted, however very little experimental characterization of these deep defects exists. In this work we use admittance spectroscopy (AS) and deep level transient spectroscopy (DLTS) to characterize devices built using CZTSSe absorber layers deposited via both coevaporation and solution processing. AS reveals a band of widely-distributed activation energies for traps or energy barriers for transport, especially in the solution deposited case. DLTS reveals signatures of deep majority and minority traps within both types of samples.
Not Available
Explore the source record for details and available documents.
Not provided.
Here, we concur with Azizi-Rad et al. (2021) that it is vital to critically evaluate and compare different soil carbon models, and we welcome the opportunity to further describe the unique contribution of the PROMISE model (Waring et al., 2020) to this literature. The PROMISE framework does share many features with established biogeochemical models, as our original manuscript highlighted in Table 1, and our work builds upon model innovations developed by many different groups, including that of Azizi-Rad and colleagues. Yet, the PROMISE framework is distinctive due to where it places mechanistic emphasis, and how these mechanisms are formalized in the mathematical model structure.
Not Available
Throughout the mechanical design process, designers, the majority of whom are men, often fail to consider the needs of women, resulting in consequences ranging from inconvenience to increased risk of serious injury or death. Although these biases are well studied in other fields of research, the mechanical design field lacks formal investigation into this phenomenon. In this study, engineering students (n = 301) took a survey in which they read a Persona describing a student makerspace user and a Walkthrough describing the user’s interaction with the makerspace while completing a project. During the Walkthrough, the user encountered various obstacles or Pain Points. Participants were asked to recall and evaluate the Pain Points that the user encountered and then evaluated their perceptions of the makerspace and user. Furthermore, the independent variables under investigation were the gender of the user Persona (woman, gender-neutral, or man), the Walkthrough room case (crafting or woodworking makerspace), and the modality of the Persona and Walkthrough (text- or audio-based). Results showed that participants from the Text-based modality were better able to recall Pain Points compared to participants from the Audio-based modality. Pain Points were assessed as more severe when they impacted women users, potentially stemming from protective paternalism. In addition to finding that the gender of a user impacted the way a task environment was perceived, results confirmed the presence of androcentrism, or “default man” assumptions, in the way designers view end users of unknown gender. Promisingly, providing user Persona information in an audio modality significantly reduced this bias compared to text-based modalities, indicating that providing richer detail in user personas has the capability to reduce gender bias in designers.
In this work, the authors quantify field emission properties of cathodes made from carbon nanotube (CNT) fibers. The cathodes were arranged in different configurations to determine the effect of cathode geometry on the emission properties. Various geometries were investigated including (1) flat cut fiber tip, (2) folded fiber, (3) looped fiber, and (4) fibers wound around a cylinder. The authors employ a custom field emission microscope to quantify I-V characteristics in combination with laterally resolved field-dependent electron emission area. Additionally, they look at the very early emission stages, first when a CNT fiber is turned on for the first time, which is then followed by multiple ramp-up/down runs. Upon the first turn on, all fibers demonstrated limited and discrete emission area. During ramping runs, all CNT fibers underwent multiple (minor and/or major) breakdowns, which improved emission properties in that turn-on field decreased and field enhancement factor and emission area both increased. It is proposed that breakdowns are responsible for removing initially undesirable emission sites caused by stray fibers higher than average. This initial breakdown process gives way to a larger emission area that is created when the CNT fiber subcomponents unfold and align with the electric field. Overall, the authors' results form the basis for careful evaluation of CNT fiber cathodes for dc or low frequency pulsed power systems in which large uniform area emission is required or for narrow beam high frequency applications in which high brightness is a must.
Prior research has shown that physicians’ medical decisions can be influenced by sequential context, particularly in cases where successive stimuli exhibit similar characteristics when analyzing medical images. This type of systematic error is known to psychophysicists as sequential context effect as it indicates that judgments are influenced by features of and decisions about the preceding case in the sequence of examined cases, rather than being based solely on the peculiarities unique to the present case. We determine if radiologists experience some form of context bias, using screening mammography as the use case. To this end, we explore correlations between previous perceptual behavior and diagnostic decisions and current decisions. We hypothesize that a radiologist’s visual search pattern and diagnostic decisions in previous cases are predictive of the radiologist’s current diagnostic decisions. To test our hypothesis, we tasked 10 radiologists of varied experience to conduct blind reviews of 100 four-view screening mammograms. Eye-tracking data and diagnostic decisions were collected from each radiologist under conditions mimicking clinical practice. Perceptual behavior was quantified using the fractal dimension of gaze scanpath, which was computed using the Minkowski–Bouligand box-counting method. To test the effect of previous behavior and decisions, we conducted a multifactor fixed-effects ANOVA. Further, to examine the predictive value of previous perceptual behavior and decisions, we trained and evaluated a predictive model for radiologists’ current diagnostic decisions. ANOVA tests showed that previous visual behavior, characterized by fractal analysis, previous diagnostic decisions, and image characteristics of previous cases are significant predictors of current diagnostic decisions. Additionally, predictive modeling of diagnostic decisions showed an overall improvement in prediction error when the model is trained on additional information about previous perceptual behavior and diagnostic decisions.
Broadband laser ranging (BLR) is essentially a spectral interferometer used to infer distance to a moving target. The light source is a mode-locked fiber laser, and chromatic dispersion maps the spectral interference pattern into the time domain, yielding chirped beat signals at the detector. A BLR record is a sequence of these chirped signals, representing consecutive target positions. To infer distance to a target, each underlying pulse envelope must be consistently registered and subtracted despite environmentally-induced variability. Then, nonlinear transformation of the phase is applied to remove the chirp, an FFT is performed to determine the peak frequency of the de-chirped signal, and a calibration factor relating de-chirped frequency to distance results in target position. This article discusses these analysis steps are in detail.
The {gamma} dose comparison tool has been used by numerous investigators to quantitatively compare multidimensional dose distributions. The {gamma} tool requires the specification of dose and distance-to-agreement (DTA) criteria for acceptable variations between the dose distributions. The tool then provides a comparison that simultaneously evaluates the dose difference and distance to agreement of the two dose distributions. One of the weaknesses of the tool is that the comparison requires one of the dose distributions to have a relatively high spatial resolution, with points spaced significantly closer than the DTA criterion. The determination of {gamma} involves an exhaustive search process, so the computation time is significant if an accurate {gamma} is desired. The reason for the need for high spatial resolution lies with the fact that the {gamma} tool measures the closest point in one of the dose distributions (the evaluated distribution) with individual points of the other distribution (the reference distribution) when the two distributions are normalized by the dose difference and DTA criteria for the dose and spatial coordinates, respectively. The closest point in the evaluated distribution to a selected reference distribution point is the value of {gamma} at that reference point. If individual evaluated dose distribution points are compared, the closest point may not accurately reflect the closest value of the evaluated distribution as if it were interpolated on an infinite resolution grid. Therefore, a reinterpretation of the {gamma} distribution as the closest geometric distance between the two distributions is proposed. This is conducted by subdividing the evaluated distribution into simplexes; line segments, triangles, and tetrahedra for one, two, and three-dimensional (3D) dose distributions. The closest distance between any point and these simplexes can be straightforwardly computed using matrix multiplication and inversion without the need of interpolating the original evaluated distribution. While an exhaustive search is still required, not having to interpolate the evaluated distribution avoids the drastic growth of calculation time incurred by interpolation and makes the {gamma} tool more practical and more accurate. In our experiment, the geometric method accurately computes {gamma} distributions between 3D dose distributions on a 200x200x50 grid within two minutes.