Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Characterization of extreme ultraviolet laser ablation mass spectrometry for actinide trace analysis and nanoscale isotopic imaging

The purpose of this research was to characterize Extreme Ultraviolet Time-of-Flight (EUV TOF) Laser Ablation Mass Spectrometry for high spatial resolution elemental and isotopic analysis. We compare EUV TOF results with Secondary Ionization Mass Spectrometry (SIMS) to orient the EUV TOF method within the overall field of analytical mass spectrometry. Using the well-characterized NIST 61x glasses, we show that the EUV ionization approach produces relatively few molecular ion interferences in comparison to TOF SIMS. We demonstrate that the ratio of element ion to element oxide ion is adjustable with EUV laser pulse energy and that the EUV TOF instrument has a sample utilization efficiency of 0.014%. The EUV TOF system also achieves a lateral resolution of 80 nm and we demonstrate this lateral resolution with isotopic imaging of closely spaced particles or uranium isotopic standard materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HOW TO LIGHT IT UP: SIMULATING RAM-PRESSURE STRIPPED X-RAY BRIGHT TAILS

Some tails of ram-pressure stripped galaxies are detected in H I, some in H{alpha}, and some in X-ray (but never in all three so far). We use numerical simulations to probe the conditions for the production of X-ray bright tails, demonstrating that the primary requirement is a high-pressure intracluster medium (ICM). This is because the stripped tail is mostly in pressure equilibrium with the ICM, but mixing leaves it with densities and temperatures intermediate between the cold gas in the disk and the hot ICM. Given a high enough ICM pressure, this mixed gas lies in the X-ray bright region of the phase diagram. We compare the simulations to observations of the ram-pressure stripped tail of ESO 137-001, showing excellent agreement in the total measured X-ray and H{alpha} emission and non-flaring morphology of the tail, and consistent H I measurements. Using these comparisons, we constrain the level of mixing and efficiency of heat conduction in the ICM.

79 ASTRONOMY AND ASTROPHYSICS↗

New evidence for efficient collisionless heating of electrons at the reverse shock of a young supernova remnant

Although collisionless shocks are ubiquitous in astrophysics, certain key aspects of them are not well understood. In particular, the process known as collisionless electron heating, whereby electrons are rapidly energized at the shock front, is one of the main open issues in shock physics. Here, we present the first clear evidence for efficient collisionless electron heating at the reverse shock of Tycho's supernova remnant (SNR), revealed by Fe K diagnostics using high-quality X-ray data obtained by the Suzaku satellite. We detect Kβ (3p → 1s) fluorescence emission from low-ionization Fe ejecta excited by energetic thermal electrons at the reverse shock front, which peaks at a smaller radius than Fe Kα (2p → 1s) emission dominated by a relatively highly ionized component. Comparisons with our hydrodynamical simulations imply instantaneous electron heating to a temperature 1000 times higher than expected from Coulomb collisions alone. The unique environment of the reverse shock, which is propagating with a high Mach number into rarefied ejecta with a low magnetic field strength, puts strong constraints on the physical mechanism responsible for this heating and favors a cross-shock potential created by charge deflection at the shock front. Our sensitive observation also reveals that the reverse shock radius of this SNR is about 10% smaller than the previous measurement using the Fe Kα morphology from the Chandra observations. Since strong Fe Kβ fluorescence is expected only from low-ionization plasma where Fe ions still have many 3p electrons, this feature is key to diagnosing the plasma state and distribution of the immediate postshock ejecta in a young SNR.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of High Soft X-Ray Drive in Large-Scale Hohlraums at the National Ignition Facility

The first soft x-ray radiation flux measurements from hohlraums using both a 96 and a 192 beam configuration at the National Ignition Facility have shown high x-ray conversion efficiencies of {approx}85%-90%. These experiments employed gold vacuum hohlraums, 6.4 mm long and 3.55 mm in diameter, heated with laser energies between 150-635 kJ. The hohlraums reached radiation temperatures of up to 340 eV. These hohlraums for the first time reached coronal plasma conditions sufficient for two-electron processes and coronal heat conduction to be important for determining the radiation drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient tool for QA of MLC-equipped robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

A Study of Muon Ionization Cooling at MICE

A Neutrino Factory based on a high-energy muon storage-ring is proposed to study neutrino oscillation with high precision. An emittance reduction of muon beam by ionization cooling, which has never been demonstrated in practice, is one of the critical issues for Neutrino Factory. The international Muon Ionisation Cooling Experiment (MICE) is the first experiment to verify an effect of the ionization cooling with muons. MICE will measure a change in transverse emittance of approximately 10% with a precision of ±0.1%. In order to meet the requirements, muon trackers based on 350 μm diameter scintillating fibers have been proposed. The construction of such trackers is a very challenging task and some innovative techniques are needed to realize, since there have been no trackers made with such a small diameter of scintillating fibers in the world. Upstream and downstream SciFi trackers have been successfully constructed with the international collaboration of UK, US and Japan by 2008. Both of the trackers have been tested with cosmic-rays at the RAL by 2009, at which high tracking efficiencies more than 90% are measured for both trackers. It is also confirmed that by collecting the misalignments found in both of the trackers, the requirements for the emittance measurement is met.

43 PARTICLE ACCELERATORS↗

Magnetic iron oxide nanoparticles for the collection and direct measurement of adsorbed alpha-emitting radionuclides from environmental waters by liquid scintillation analysis

Radioactive contamination in the environment, be it from accidental or intentional release, can create an urgent need to assess water and food supplies, the environment, and monitor human health. Alpha-emitting radionuclides represent the most ionizing, and therefore the most damaging, form of radiation when internalized. Additionally, because of its ease of energy attenuation in solids or liquids, alpha emissions cannot be reliably monitored using non-destructive means. In the event of such an emergency, rapid and efficient methods will be needed to screen scores of samples (food, water, and human excreta) within a short time window. Unfortunately, the assay of alpha-emitting radionuclides using traditional radioanalytical methods is typically labor intensive and time consuming. The creation of analytical counting sources typically requires a series of chemical treatment steps to achieve well performing counting sources. In an effort to devise radioanalytical methods that are fast, require little labor, and minimize the use of toxic or corrosive agents, researchers at PNNL have evaluated magnetite (Fe3O4) nanoparticles as extracting agents for alpha-emitting radionuclides from chemically unmodified aqueous systems. It is demonstrated that bare magnetic nanoparticles exhibit high affinity for representative α-emitting radionuclides (241Am and 210Po) from representative aqueous matrices: river and ground water. Furthermore, use of the magnetic properties of these materials to concentrate the sorbed analyte from the bulk aqueous solution has been demonstrated. The nanoparticle concentrate can be either directly dispensed into scintillation cocktail, or first dissolved and then added to scintillation cocktail as a solution for alpha emission assay by liquid scintillation analysis. Despite the extreme quench caused by the metal oxide suspensions, the authors have demonstrated that quench correction features available on modern liquid scintillation analyzers can be employed to assure that quench-induced analytical biases can be avoided.

actinide↗

Assessment of Active Metal Removal from Pyroprocessing Salt by Electrodeposition

Active metals present in used nuclear fuel dissolve into the salt during pyroprocessing, but are not recovered during electrorefining or drawdown operations due to their chemical stability in the salt. The accumulation of 137 Cs and 90 Sr in process salt over time increases the heat load and ionizing radiation level of the salt such that it must be replaced frequently, resulting in a significant amount of salt waste. An effective means of removing active metals from the molten salt to enable recycle of the electrolyte (e.g., LiCl/KCl) would increase the efficiency of pyroprocessing and decrease the volume of salt waste requiring disposal.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraining the Low-Temperature Oxidation Mechanism of n -Hexanol through the Detection and Identification of C 6 Elusive Intermediates

Alcohol-based fuels are currently considered to be viable energy carriers for the transportation sector. Consequently, a comprehensive mechanistic understanding of the low-temperature oxidation of alcohols is essential for application in advanced low-temperature compression engines. Here, in this work, a multidimensional approach involving experimental investigations, kinetic modeling, and theoretical calculations was used to provide new insights into the low-temperature oxidation mechanism of a C 6 alcohol, n -hexanol (CH 3 (CH 2 ) 5 OH), through the detection and identification of elusive C 6 intermediates. The oxidation of n-hexanol was investigated in a jet-stirred reactor under stoichiometric conditions (ϕ = 1.0), an initial fuel concentration of 2%, a residence time of 2 s, a temperature range between 500 and 660 K, and a pressure of 700 Torr. The reactants, intermediates, and final products were detected and identified by means of molecular-beam mass spectrometry coupled with single-photon ionization employing tunable synchrotron-generated vacuum ultraviolet radiation. Chemical kinetic simulations were performed using a previously published kinetic model (Togbé et al., Energy Fuels 2010, 11, 5859−5875) to predict the reactivity of n-hexanol and elucidate the predominant formation pathways of the observed low-temperature species. Experimental photoionization efficiency curves in conjunction with ab initio calculations, enabled the identification of important low-temperature species, such as C 6 unsaturated alcohols, C 6 olefinic hydroperoxides, C 6 cyclic ethers, C 6 diones, and C 6 ketohydroperoxides. The results of this study provide valuable insight into the mechanism of the low-temperature oxidation chemistry of n -hexanol, contributing to the development of kinetic models for the low-temperature oxidation of n-hexanol and other long-chain linear alcohols.

alcohols↗

ISM EXCITATION AND METALLICITY OF STAR-FORMING GALAXIES AT Z ≃ 3.3 FROM NEAR-IR SPECTROSCOPY

We study the relationship between stellar mass, star formation rate (SFR), ionization state, and gas-phase metallicity for a sample of 41 normal star-forming galaxies at 3 ≲ z ≲ 3.7. The gas-phase oxygen abundance, ionization parameter, and electron density of ionized gas are derived from rest-frame optical strong emission lines measured on near-infrared spectra obtained with Keck/Multi-Object Spectrograph for Infra-Red Exploration. We remove the effect of these strong emission lines in the broadband fluxes to compute stellar masses via spectral energy distribution fitting, while the SFR is derived from the dust-corrected ultraviolet luminosity. The ionization parameter is weakly correlated with the specific SFR, but otherwise the ionization parameter and electron density do not correlate with other global galaxy properties such as stellar mass, SFR, and metallicity. The mass–metallicity relation (MZR) at z ≃ 3.3 shows lower metallicity by ≃0.7 dex than that at z = 0 at the same stellar mass. Our sample shows an offset by ≃0.3 dex from the locally defined mass–metallicity–SFR relation, indicating that simply extrapolating such a relation to higher redshift may predict an incorrect evolution of MZR. Furthermore, within the uncertainties we find no SFR–metallicity correlation, suggesting a less important role of SFR in controlling the metallicity at high redshift. We finally investigate the redshift evolution of the MZR by using the model by Lilly et al., finding that the observed evolution from z = 0 to z ≃ 3.3 can be accounted for by the model assuming a weak redshift evolution of the star formation efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-consistent evolution of plasma discharge and electromagnetic fields in a microwave pulse compressor

Nanosecond-scale evolution of plasma and RF electromagnetic fields during the release of energy from a microwave pulse compressor with a plasma interference switch was investigated numerically using the code MAGIC. The plasma was simulated in the scope of the gas conductivity model in MAGIC. The compressor embodied an S-band cavity and H-plane waveguide tee with a shorted side arm filled with pressurized gas. In a simplified approach, the gas discharge was initiated by setting an external ionization rate in a layer crossing the side arm waveguide in the location of the electric field antinode. It was found that with increasing ionization rate, the microwave energy absorbed by the plasma in the first few nanoseconds increases, but the absorption for the whole duration of energy release, on the contrary, decreases. In a hybrid approach modeling laser ignition of the discharge, seed electrons were set around the electric field antinode. In this case, the plasma extends along the field forming a filament and the plasma density increases up to the level at which the electric field within the plasma decreases due to the skin effect. Then, the avalanche rate decreases but the density still rises until the microwave energy release begins and the electric field becomes insufficient to support the avalanche process. The extraction of the microwave pulse limits its own power by terminating the rise of the plasma density and filament length. For efficient extraction, a sufficiently long filament of dense plasma must have sufficient time to be formed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-350: Verification of Gating Performance of a New Elekta Gating Solution: Response Kit and Catalyst System

Purpose: In this work, we have tested the performance of new respiratory gating solutions for Elekta linacs. These solutions include the Response gating and the C-RAD Catalyst surface mapping system.Verification measurements have been performed for a series of clinical cases. We also examined the beam on latency of the system and its impact on delivery efficiency. Methods: To verify the benefits of tighter gating windows, a Quasar Respiratory Motion Platform was used. Its vertical-motion plate acted as a respiration surrogate and was tracked by the Catalyst system to generate gating signals. A MatriXX ion-chamber array was mounted on its longitudinal-moving platform. Clinical plans are delivered to a stationary and moving Matrix array at 100%, 50% and 30% gating windows and gamma scores were calculated comparing moving delivery results to the stationary result. It is important to note that as one moves to tighter gating windows, the delivery efficiency will be impacted by the linac's beam-on latency. Using a specialized software package, we generated beam-on signals of lengths of 1000ms, 600ms, 450ms, 400ms, 350ms and 300ms. As the gating windows get tighter, one can expect to reach a point where the dose rate will fall to nearly zero, indicating that the gating window is close to beam-on latency. A clinically useful gating window needs to be significantly longer than the latency for the linac. Results: As expected, the use of tighter gating windows improved delivery accuracy. However, a lower limit of the gating window, largely defined by linac beam-on latency, exists at around 300ms. Conclusion: The Response gating kit, combined with the C-RAD Catalyst, provides an effective solution for respiratorygated treatment delivery. Careful patient selection, gating window design, even visual/audio coaching may be necessary to ensure both delivery quality and efficiency. This research project is funded by Elekta.

07 ISOTOPE AND RADIATION SOURCES↗

Optimizing the Internal Cell Structure of the Radon Monitor Based on Electrostatic Collection Method

Abstract As Rn-222 decays, an alpha particle is emitted and the residual polonium nucleus recoils in the opposite direction. At the end of the recoil path, 88% of the polonium atoms have a positive charge and 12% are neutral. The electric potential distribution in the 60 ml hemispherical internal cell of the radon monitor based on electrostatic collection is studied for reducing the combined probability of the positively charged Po-218 and the OH− produced by the ionization of water vapour in the air. The COMSOL software is used to simulate the electric potential distribution in the internal cell of the radon monitor based on the electrostatic collection method at 27°C, a pressure of 0.1 Mpa. For improving the collection efficiency of Po-218 ions, the average collection time along vertical and oblique lines is calculated when the upper surface of the internal cell is plastic, uncharged metal and charged metal, respectively. Assuming that the gas in the internal cell is uniformly distributed, the results show that if the upper surface of the hemispherical internal cell is plastic or uncharged metal, the electric potential formed in the internal cell is more uniform, and it is beneficial to reduce the total collection time of the positively charged Po-218 ions, thereby improving collection efficiency. The simulation results can be used as an effective reference for optimizing the design of the internal cell structure of the radon monitor based on electrostatic collection method.

Fan, Zhongkai (ORCID:0000000181247459)↗

SU-C-BRD-05: Non-Invasive in Vivo Biodosimetry in Radiotherapy Patients Using Electron Paramagnetic Resonance (EPR) Spectroscopy

Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence of radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Error Mitigation by Read-Retry Technique for MLC 3-D NAND Flash Memory

Here, we have evaluated the Read-Retry (RR) functionality of the 3-D NAND chip of multilevel-cell (MLC) configuration after total ionization dose (TID) exposure. The RR function is typically offered in the high-density state-of-the-art NAND memory chips to recover data once the default memory read method fails to correct data with error correction codes (ECCs). In this work, we have applied the RR method on the irradiated 3-D NAND chip that was exposed with a Co-60 gamma-ray source for TID up to 50 krad (Si). Based on our experimental evaluation results, we have proposed an algorithm to efficiently implement the RR method to extend the radiation tolerance of the NAND memory chip. Our experimental evaluation shows that the RR method coupled with ECC can ensure data integrity of MLC 3-D NAND for TID up to 50 krad (Si).

3-D NAND↗

Neutrino event selection in the MicroBooNE liquid argon time projection chamber using Wire-Cell 3D imaging, clustering, and charge-light matching

An accurate and efficient event reconstruction is required to realize the full scientific capability of liquid argon time projection chambers (LArTPCs). The current and future neutrino experiments that rely on massive LArTPCs create a need for new ideas and reconstruction approaches. Wire-Cell, proposed in recent years, is a novel tomographic event reconstruction method for LArTPCs. The Wire-Cell 3D imaging approach capitalizes on charge, sparsity, time, and geometry information to reconstruct a topology-agnostic 3D image of the ionization electrons prior to pattern recognition. A second novel method, the many-to-many charge-light matching, then pairs the TPC charge activity to the detected scintillation light signal, thus enabling a powerful rejection of cosmic-ray muons in the MicroBooNE detector. A robust processing of the scintillation light signal and an appropriate clustering of the reconstructed 3D image are fundamental to this technique. In this paper, we describe the principles and algorithms of these techniques and their successful application in the MicroBooNE experiment. A quantitative evaluation of the performance of these techniques is presented. Using these techniques, a 95% efficient pre-selection of neutrino charged-current events is achieved with a 30-fold reduction of non-beam-coincident cosmic-ray muons, and about 80% of the selected neutrino charged-current events are reconstructed with at least 70% completeness and 80% purity.

3D imaging↗

Detection efficiency measurement and operational tests of the X-Arapuca for the first module of DUNE far detector

The Deep Underground Neutrino Experiment (DUNE) is a dual-site experiment for long-baseline neutrino oscillation studies, able to resolve the neutrino mass hierarchy and measure δ$_{CP}$. DUNE will also have sensitivity to supernova neutrinos and to processes beyond the Standard Model, such as nucleon decay searches. The Far Detector (FD) will consist of four liquid argon TPC (17.5 kt total mass) with systems for the detection of charge and scintillation light produced by an ionization event. The charge detection system permits both calorimetry and position determination. In addition, the photon-detection system (PDS) enhances the detector capabilities for all DUNE physics drivers. The PDS of the first FD module consists of light collector modules placed in the inactive space between the innermost wire planes of the TPC anode. The light collectors, the so-called X-ARAPUCAS, are functionally a light trap that captures wavelength-shifted photons inside boxes with highly reflective internal surfaces where they are guided to Silicon Photo-multipliers (SiPM) by wavelength-shifting (WLS) bars. Functionality and operational tests of the X-ARAPUCAS to be installed in ProtoDUNE-SP phase II (FD DUNE prototype at the scale 1:20), as well as the measurement of their absolute detection efficiency is reported in this publication.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial Estimation of Populations at Risk from Radiological Dispersion Device Terrorism Incidents

Delineation of the location and size of the population potentially at risk of exposure to ionizing radiation is one of the key analytical challenges in estimating accurately the severity of the potential health effects associated with a radiological terrorism incident. Regardless of spatial scale, the geographical units for which population data commonly are collected rarely coincide with the geographical scale necessary for effective incident management and medical response. This paper identifies major government and commercial open sources of U.S. population data and presents a GIS-based approach for allocating publicly available population data, including age distributions, to geographical units appropriate for planning and implementing incident management and medical response strategies. In summary: The gravity model offers a straight-forward, empirical tool for estimating population flows, especially when geographical areas are relatively well-defined in terms of accessibility and spatial separation. This is particularly important for several reasons. First, the spatial scale for the area impacted by a RDD terrorism event is unlikely to match fully the spatial scale of available population data. That is, the plume spread typically will not uniformly overlay the impacted area. Second, the number of people within the impacted area varies as a function whether an attack occurs during the day or night. For example, the population of a central business district or industrial area typically is larger during the day while predominately residential areas have larger night time populations. As a result, interpolation techniques that link population data to geographical units and allocate those data based on time-frame at a spatial scale that is relevant to enhancing preparedness and response. The gravity model's main advantage is that it efficiently allocates readily available, open source population data to geographical units appropriate for planning and implementing incident management and medical monitoring strategies. The importance of being able to link population estimates to geographic areas during the course of an RDD incident can be understood intuitively: - The spatial distribution of actual total dose equivalents of ionizing radiation is likely to vary due to changes in meteorological parameters as an event evolves over time; - The size of the geographical area affected also is likely to vary as a function of the actual release scenario; - The ability to identify the location and size of the populations that may be exposed to doses of ionizing radiation is critical to carrying out appropriate treatment and post-event medical monitoring; - Once a spatial interaction model has been validated for a city or a region, it can then be used for simulation and prediction purposes to assess the possible human health consequences of different release scenarios. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗