Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Numerical Studies of Hall Thruster Acceleration Region Electron Transport

Azimuthal direction 1-D and azimuthal and axial direction 2-D Particle in Cell (PIC) simulations of the Hall thruster acceleration and near-plume regions are presented. The axial extent of the 2-D computational domain is based on the ExB drift parameter, 𝑫𝑬𝒙𝑩, the number of times around the channel an electron ExB drifts before being scattered. With only high energy main beam ions, the simulations produced a broad potential profile in the acceleration region. The addition of a small amount of ionization in the acceleration domain at a rate consistent with Hall thruster parameters causes the potential profile to develop two distinct regions. In the upstream portion of the computational domain, the potential profile is very steep, typical of Hall thruster acceleration regions. In the downstream portion, the potential profile is almost flat, like potentials in Hall thruster near plume regions. This bifurcation happens naturally; there is no other change in code parameters between the two results. Without the addition of a small amount of ionization in the acceleration region, the axial electron transport is very low. With ionization, the calculated ratio of electron current to ion current is the same order of those measured in Hall thrusters. This suggests that in regions with lower energy electrons and ions, plasma waves are effective in allowing crossfield transport, and axial electric fields are small. In the acceleration region, the plasma waves are less effective at scattering the energetic electrons, and high axial electric fields are needed to produce the observed cross-field electron transport.

Ortega, Alejandro Lopez↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of the Plasma Generated by Primary Electrons at Lowered Pressure

Plasma characteristics in the gap at lowered pressure in the presence of primary electrons are analyzed for the hydrodynamic model in the cold ion approximation. It is demonstrated that at a certain critical ionization level, the plasma state changes abruptly. The potential drop in the plasma can be not only more, but also less than ln(2)kTe/e, and hence the velocity of ions exiting from the plasma can be more or less than the Bohm velocity. For low ionization intensity and formation of the plasma with a high fraction of primary electrons, the velocity of secondary electron exiting from the plasma becomes equal to their thermal velocity, and their distribution differs significantly from the Boltzmann distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion current on a small spherical attractive probe in a weakly ionized plasma with ion-neutral collisions (kinetic approach)

The ion flux on a small attractive sphere (the sphere radius is much less than the Debye length) and the electric potential distribution around the sphere charged in a stationary weakly ionized plasma are calculated by the direct solution of the kinetic equation with the Bhatnagar-Gross-Krook collision term. Only a weak dependence of the ion flux on the electron temperature is found. An analytical approximation of the calculated ion current-voltage characteristics is proposed for intermediate collisionalities, where neither a collisionless theory nor a continuum fluid approach is valid. This approximation was used for calculation of the floating sphere potential. A reasonable agreement of the calculated floating sphere potential with prior numerical calculations is found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of neutral gas releases on electron beam injection from electrically tethered spacecraft

The presence of high neutral densities at low altitudes and/or during thruster firings is known to modify the spacecraft potential during active electron beam injection. Two-dimensional (three velocity) particle simulations are used to investigate the ionization processes including the neutral density required, the modification of the spacecraft potential, beam profile and spatial distribution of the return current into the spacecraft. Three processes are identified: (1) beam-induced ionization, (2) vehicle-induced ionization, and (3) beam plasma discharge. Only in the first two cases does the beam propagate away with little distortion.

Winglee, R. M.↗

Thermodynamic and Structural Factors That Influence the Redox Potentials of Tungsten–Alkylidyne Complexes

The thermodynamic and structural factors that influence the redox properties of an extensive set of tungsten–alkylidyne complexes (W(CR)L 4 X) are assessed by combining synthesis, electrochemistry, and computational modeling based on free energy calculations of oxidation potentials at the density functional theory level. The observed linear correlations among oxidation potentials, HOMO energies, and gas-phase ionization energies are found to be consistent with the approximately constant solvation free energy differences between reduced and oxidized species over the complete set. The W–X bond length, trans to the alkylidyne ligand, is discovered to be a good descriptor of the positioning of the key frontier orbitals that regulate the redox properties of the complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.↗

Electron-helium scattering in Debye plasmas

Electron-helium scattering in weakly coupled hot-dense (Debye) plasma has been investigated using the convergent close-coupling method. The Yukawa-type Debye-Hueckel potential has been used to describe plasma Coulomb screening effects. Benchmark results are presented for momentum transfer cross sections, excitation, ionization, and total cross sections for scattering from the ground and metastable states of helium. Calculations cover the entire energy range up to 1000 eV for the no screening case and various Debye lengths (5-100 a{sub 0}). We find that as the screening interaction increases, the excitation and total cross sections decrease, while the total ionization cross sections increase.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrafast strong-field dissociative ionization dynamics of CH{sub 2}Br{sub 2} probed by femtosecond soft x-ray transient absorption spectroscopy

Femtosecond time-resolved soft x-ray transient absorption spectroscopy based on a high-order harmonic generation source is used to investigate the dissociative ionization of CH{sub 2}Br{sub 2} induced by 800 nm strong-field irradiation. At moderate laser peak intensities (2.0x10{sup 14} W/cm{sup 2}), strong-field ionization is accompanied by ultrafast C-Br bond dissociation, producing both neutral Br ({sup 2}P{sub 3/2}) and Br* ({sup 2}P{sub 1/2}) atoms together with the CH{sub 2}Br{sup +} fragment ion. The measured rise times for Br and Br* are 130{+-}22 fs and 74{+-}10 fs, respectively. The atomic bromine quantum state distribution shows that the Br/Br* population ratio is 8.1{+-}3.8 and that the Br {sup 2}P{sub 3/2} state is not aligned. The observed product distribution and the time scales of the photofragment appearances suggest that multiple field-dressed potential energy surfaces are involved in the dissociative ionization process. At higher laser peak intensities (6.2x10{sup 14} W/cm{sup 2}), CH{sub 2}Br{sub 2}{sup +} undergoes sequential ionization to form the metastable CH{sub 2}Br{sub 2}{sup 2+} dication. These results demonstrate the potential of core-level probing with high-order harmonic transient absorption spectroscopy for studying ultrafast molecular dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Bistable low temperature (77 K) impurity breakdown in p-type 4H-SiC

Low-temperature (77 K) forward current-voltage characteristics of 4H-SiC p{sup +}-p-n{sup +}-n (substrate) mesa epitaxial diode structures have been measured. The characteristics are S-shaped, which is accounted for by the bistable nature of the impact ionization of frozen-out acceptor atoms of aluminum.

36 MATERIALS SCIENCE↗

Physical, Heritable and Age-Related Factors as Modifiers of Radiation Cancer Risk in Patched Heterozygous Mice

Purpose: To address the tumorigenic potential of exposure to low/intermediate doses of ionizing radiation and to identify biological factors influencing tumor response in a mouse model highly susceptible to radiogenic cancer. Methods and Materials: Newborn Ptc1 heterozygous mice were exposed to X-ray doses of 100, 250, and 500 mGy, and tumor development was monitored for their lifetime. Additional groups were irradiated with the same doses and sacrificed at fixed times for determination of short-term endpoints, such as apoptosis and early preneoplastic lesions in cerebellum. Finally, groups of Ptc1 heterozygous mice were bred on the C57BL/6 background to study the influence of common variant genes on radiation response. Results: We have identified a significant effect of low-intermediate doses of radiation (250 and 500 mGy) in shortening mean survival and inducing early and more progressed stages of tumor development in the cerebellum of Ptc1{sup +/-} mice. In addition, we show that age at exposure and heritable factors are potent modifiers of radiation-related cancer risk. Conclusions: The Ptc1 knockout mouse model offers a highly sensitive system that may potentially help to improve understanding and quantification of risk at low doses, such as doses experienced in occupational and medical exposures, and clarify the complex interactions between genetic and environmental factors underlying cancer susceptibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-level effects of low dose rate ionizing radiation on southern toad, Anaxyrus [Bufo] terrestris

Despite their potential vulnerability to contaminants from exposure at multiple life stages, amphibians are one of the least studied groups of vertebrates in ecotoxicology, and research on radiation effects in amphibians is scarce. We used multiple endpoints to assess the radiosensitivity of the southern toad ( Anaxyrus [Bufo] terrestris ) during its pre-terrestrial stages of development –embryonic, larval, and metamorphic. Toads were exposed, from several hours after oviposition through metamorphosis (up to 77 days later), to four low dose rates of ¹³⁷Cs at 0.13, 2.4, 21, and 222 mGy d⁻¹, resulting in total doses up to 15.8 Gy. Radiation treatments did not affect hatching success of embryos, larval survival, or the length of the larval period. The individual family variation in hatching success of embryos was larger than the radiation response. In contrast, newly metamorphosed individuals from the higher dose-rate treatments had higher mass and mass/length body indices, a measure which may relate to higher post-metamorphic survival. The increased mass and index at higher dose rates may indicate that the chronic, low dose rate radiation exposures triggered secondary responses. Additionally, the increases in growth were linked to a decrease in DNA damage (as measured by the Comet Assay) in red blood cells at a dose rate of 21mGy d⁻¹ and a total dose of 1.1 Gy. In conclusion, the complex effects of low dose rates of ionizing radiation may trigger growth and cellular repair mechanisms in amphibian larvae.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Interatomic Coulombic decay in a He dimer: Ab initio potential-energy curves and decay widths

The energy gained by either of the two helium atoms in a helium dimer through simultaneous ionization and excitation can be efficiently transferred to the other helium atom, which then ionizes. The respective relaxation process called interatomic Coulombic decay (ICD) is the subject of the present paper. Specifically, we are interested in ICD of the lowest of the ionized excited states, namely, the He{sup +}(n=2)He states, for which we calculated the relevant potential-energy curves and the interatomic decay widths. The full-configuration interaction method was used to obtain the potential-energy curves. The decay widths were computed by utilizing the Fano ansatz, Green's-function methods, and the Stieltjes imaging technique. The behavior of the decay widths with the interatomic distance is examined and is elucidated, whereby special emphasis is given to the asymptotically large interatomic separations. Our calculations show that the electronic ICD processes dominate over the radiative decay mechanisms over a wide range of interatomic distances. The ICD in the helium dimer has recently been measured by Havermeier et al. [Phys. Rev. Lett. 104, 133401 (2010)]. The impact of nuclear dynamics on the ICD process is extremely important and is discussed by Sisourat et al. [Nat. Phys. 6, 508 (2010)] based on the ab initio data computed in the present paper.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental and modeling analysis of fast ionization wave discharge propagation in a rectangular geometry

Fast ionization wave (FIW), nanosecond pulse discharge propagation in nitrogen and helium in a rectangular geometry channel/waveguide is studied experimentally using calibrated capacitive probe measurements. The repetitive nanosecond pulse discharge in the channel was generated using a custom designed pulsed plasma generator (peak voltage 10-40 kV, pulse duration 30-100 ns, and voltage rise time {approx}1 kV/ns), generating a sequence of alternating polarity high-voltage pulses at a pulse repetition rate of 20 Hz. Both negative polarity and positive polarity ionization waves have been studied. Ionization wave speed, as well as time-resolved potential distributions and axial electric field distributions in the propagating discharge are inferred from the capacitive probe data. ICCD images show that at the present conditions the FIW discharge in helium is diffuse and volume-filling, while in nitrogen the discharge propagates along the walls of the channel. FIW discharge propagation has been analyzed numerically using quasi-one-dimensional and two-dimensional kinetic models in a hydrodynamic (drift-diffusion), local ionization approximation. The wave speed and the electric field distribution in the wave front predicted by the model are in good agreement with the experimental results. A self-similar analytic solution of the fast ionization wave propagation equations has also been obtained. The analytic model of the FIW discharge predicts key ionization wave parameters, such as wave speed, peak electric field in the front, potential difference across the wave, and electron density as functions of the waveform on the high voltage electrode, in good agreement with the numerical calculations and the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric Pressure Ionization Using a High Voltage Target Compared to Electrospray Ionization

A new atmospheric pressure ionization (API) source, viz. UniSpray, was evaluated for mass spectrometry (MS) analysis of pharmaceutical compounds by head-to-head comparison with electrospray ionization (ESI) on the same high-resolution MS system. The atmospheric pressure ionization source is composed of a grounded nebulizer spraying onto a high voltage, cylindrical stainless steel target. Molecules are ionized in a similar fashion to electrospray ionization, predominantly producing protonated or deprotonated species. Adduct formation (e.g., proton and sodium adducts) and in-source fragmentation is shown to be almost identical between the two sources. The performance of the new API source was compared with electrospray by infusion of a mix of 22 pharmaceutical compounds with a wide variety of functional groups and physico-chemical properties (molecular weight, logP, and pKa) in more than 100 different conditions (mobile phase strength, solvents, pH, and flow rate). The new API source shows an intensity gain of a factor 2.2 compared with ESI considering all conditions on all compounds tested. Finally, some hypotheses on the ionization mechanism, similarities, and differences with ESI, are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transferring Ions from Solution to the Gas Phase: The Two Basic Principles

The efficient formation of gaseous ions is the crucial step in all successful mass spectrometric experiments. The invention of electrospray ionization (ESI) has strongly facilitated this step by transferring preformed ions directly from solution to the gas phase – thereby circumventing the need to first convert analytes to the gas phase and then ionize them – and therefore ESI has become an extremely useful and widely applied MS technique. The invention of sonic spray ionization (SSI) has also allowed for the transfer of ions from solution into the gas phase, but without the assistance of a voltage or heating. Numerous ionization techniques, using similar principles to those applied in either ESI or SSI, have subsequently been developed. Although experimental conditions used in such techniques vary markedly, herein we argue that they are all based on either one of two basic principles by which ions can be transferred from solution to the gas phase, that is: via (1) neutralizing the counter ion, or (2) separating the ions. We have selected 35 such techniques and categorized them accordingly. This article thereby aims to establish the basic principles by which gaseous ions can be obtained from solvated ions. We further propose that any new ionization technique used to transfer solvated ions to the gas phase will similarly fall into one of these two mechanistic categories. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Determination of the Ionization Energies of MoSe 2 , WS 2 , and MoS 2 on SiO 2 Using Photoemission Electron Microscopy

Here, the values of the ionization energies of transition metal dichalcogenides (TMDs) are needed to assess their potential usefulness in semiconductor heterojunctions for high-performance optoelectronics. Here, we report on the systematic determination of ionization energies for three prototypical TMD monolayers (MoSe 2 , WS 2 , and MoS 2 ) on SiO 2 using photoemission electron microscopy with deep ultraviolet illumination. The ionization energy displays a progressive decrease from MoS 2 , to WS 2 , to MoSe 2 , in agreement with predictions of density functional theory calculations. Combined with the measured energy positions of the valence band edge at the Brillouin zone center, we deduce that, in the absence of interlayer coupling, a vertical heterojunction comprising any of the three TMD monolayers would form a staggered (type-II) band alignment. This band alignment could give rise to long-lived interlayer excitons that are potentially useful for valleytronics or efficient electron–hole separation in photovoltaics.

36 MATERIALS SCIENCE↗