COMPASS-U Global Heat Balance Calculations

COMPASS-U is a medium size, high magnetic field experimental tokamak (R = 0.9 m, B t = 5 T, and I p = 2 MA), built at the Institute of Plasma Physics, Czech Academy of Sciences (IPP-CAS). This global heat balance calculation for COMPASS-U was done at Princeton Plasma Physics Laboratory (PPPL). Based on our previous experience of building global thermal model for National Spherical Torus Experiment-Upgrade (NSTX-U) at PPPL, this 2-D global thermal model geometry represents a typical cross section of COMPASS-U machine. The model includes thermal radiation, conduction, and convection among components and also between the machine and outer environment. Helium gas heating/cooling was modeled with fluid element and surface element. This model was used to calculate component temperatures and heat distribution during heat up, cryogenic cool down, normal operation, and fault operation scenarios. Definition of 14 main thermal scenarios was provided by IPP-CAS. First nine are normal operation scenarios. Scenarios #10–#14 are fault scenarios. Results of thermal scenario #5 will be given and discussed in this article, including peak temperatures, temperature ratcheting, energy distribution, and required cooling power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microgrid Modeling for Stability Analysis

Here this document is a summary of a report prepared by the IEEE PES Task Force (TF) on Microgrid (MG) Dynamic Modeling, IEEE Power and Energy Society, Tech. Rep. PES-TR106, 2023. In this paper, the major issues and challenges in microgrid modeling for stability analysis are discussed, and a review of state-of-the-art modeling approaches and trends is presented. In the context of the IEEE 1547 standard, the document covers issues associated with component models for MG dynamic studies and simulations, including generator and grid modeling, full and average converter models, unbalanced and balanced system conditions, dynamic and static loads, protection requirements, and detailed and simplified controls considering communications delays, packet losses, and security issues. Considering the future integration of grids and MGs to form broad integrated networks, a discussion is presented of the use of phasor vis-à-vis electromagnetic transient simulation tools for MG dynamic stability studies, as well as modeling scale-up issues and MG equivalent models. Specifically white-, grey-, and black-box models, are presented. This TF paper and companion report constitute a modeling guide for R&D groups working on developments and standards of MGs with a focus on stability issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mota Mapper: A Multi-Objective Topology-Aware Mapper Library

Mota is a library that provides several heuristics for mapping tasks to compute ranks (processes) on a networked computer cluster or supercomputer. It was originally designed for task placement of adaptive mesh refinement codes (AMR). It is multi-objective in the sense that it simultaneously balances (potentially multiple types of) computational load on each rank as well as the communication traffic between the boxes. The heuristics used for mapping include algorithms such as greedy list assignment and space-filling curves, as well as algorithms from graph analysis such as adjacency matrix bandwidth reduction, recursive bisection, and greedy graph placement.

Chan, Cy↗

Variable Speed Heat Pump Sizing Guide for Mixed-Humid Climates

The similarities and differences between different capacity units in a model family will vary depending on the manufacturer. These unit specific details are critical to choosing the VSHP capacity that will yield the highest energy savings without compromising comfort. In addition, the house construction, climate, and occupant behavior will influence the balance of the heating and cooling load on the house as well as the sensible and latent cooling demand. All of these factors need to be considered when trying to select the proper unit for the highest energy savings. Based on the simulations performed in this study, it is likely that VSHPs with an enhanced dehumidification mode can be sized up to two times the cooling load of the house without any reduction in comfort when compared to a single speed heat pump assuming a typical home and occupant behavior in the mixed-humid and cold climates.

42 ENGINEERING↗

Economics of Hybrid-Energy Systems and the Impact on Advanced Reactor Design and Operation

The economics of electricity production in the U.S. is changing with the introduction of recent federal regulations limiting carbon dioxide emissions in the electric power industry. This has already resulted in the closing of coal plants, plants which in the past to a degree served to balance production with daily variation in load. The resulting loss of electricity production is being made up with wind and solar renewables and gas-fired units, and with an increasing need for energy storage. It would appear that with the loss of the baseload component of the coal plants, the duty-cycle of the gas-fired units may necessarily increase, encroaching on the traditional nuclear plant domain with its inexpensive fuel. Gas plants are costly to operate on a continuous basis with relatively volatile fuel prices. It appears then that nuclear plants that are capable of flexible operation have the potential on an economic basis to displace gas-fired power units. For flexible operation with renewables advanced reactors have advantages over the current generation of pressurized water reactors (PWR) and the new small modular reactors (SMR). For PWRs and SMRs, pellet-cladding mechanical interaction, xenon poisoning, and thermal stress concentrations in structures place limits on the all-important response time for operation with renewables. These phenomena are, however, not as limiting for the liquid-metal fast reactor (LMR). This may permit greater power ramp rates than in a light water reactor which bestows an economic advantage in energy systems with renewables. An economic model is developed for studying electric grid options including plant mix and market rules for the case of a high renewable fraction. It returns the minimum cost solution from among a mix of plant types including nuclear, gas, and storage (i.e. hybrid energy systems) for a given fraction of electricity production by renewables. This model can be used to assess the economic advantage of nuclear plants over gas plants and advanced reactors over light water reactors in an electric grid with a high fraction of renewables. The model has an explicit treatment of plant dynamic effects, an important feature for analysis of hybrid energy systems with a renewables production component that is unpredictable and uncontrollable.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Community Guide to Regulatory Barriers Affecting Microgrids (Reports 1-3)

In response to growing risks of power outages from extreme weather and aging infrastructure, communities are increasingly exploring the potential of microgrids to provide reliable energy access. Microgrids offer promising solutions to meet this challenge but face a complex landscape of non-technical barriers, particularly regulations concerning the provision and distribution of energy. Most existing legal and regulatory frameworks were designed for a centralized, one-way power system, and are often poorly suited to handle systems that independently balance distributed energy resources with local load. This three-part report series provides a strategic analysis of existing regulatory and legal factors affecting microgrid deployments to help non-technical community leaders and decision-makers better understand the feasibility of a microgrid in their community. -Report No. 1: Foundational Issues Facing Microgrids details the universal policy barriers all microgrids face, including utility interconnection processes, rate structures, and local permitting. -Report No. 2: Single Property Microgrids outlines how direct asset ownership and operating behind-the-meter can bypass some regulatory oversight, using the Blue Lake Rancheria microgrid as a case study. -Report No. 3: Multi-Property Microgrids tackles the complex challenges of crossing public rights-of-way and navigating utility franchise rights, highlighting the Coventry microgrid project. The series equips decision-makers with phased frameworks to navigate financial and regulatory complexities, engage effectively with local utilities and Authorities Having Jurisdiction (AHJs), and structure successful microgrid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of the cubic polynomial strength criterion to the failure analysis of composite materials

A comparative failure analysis is presented based on the application of quadratic and cubic forms of the tensor polynomial lamina strength criterion to various composite structural configurations in a plane stress state. Failure loads have been predicted for off-angle laminates under simple loading conditions and for symmetric-balanced laminates subject to varying degrees of biaxial tension, including configurations subject to multimode failures. Some experimental data are also provided to support these calculations. From these results, the necessity of employing a cubic strength criterion to accurately predict the failure of composite laminae is demonstrated.

Tennyson, R. C.↗

Magnetostrophic balance in planetary dynamos - Predictions for Neptune's magnetosphere

With the purpose of estimating Neptune's magnetic field and its implications for nonthermal Neptune radio emissions, a new scaling law for planetary magnetic fields was developed in terms of externally observable parameters (the planet's mean density, radius, mass, rotation rate, and internal heat source luminosity). From a comparison of theory and observations by Voyager it was concluded that planetary dynamos are two-state systems with either zero intrinsic magnetic field (for planets with low internal heat source) or (for planets with the internal heat source sufficiently strong to drive convection) a magnetic field near the upper bound determined from magnetostrophic balance. It is noted that mass loading of the Neptune magnetosphere by Triton may play an important role in the generation of nonthermal radio emissions.

Curtis, S. A.↗

Magnetic suspension and balance systems (MSBSs)

The problems of wind tunnel testing are outlined, with attention given to the problems caused by mechanical support systems, such as support interference, dynamic-testing restrictions, and low productivity. The basic principles of magnetic suspension are highlighted, along with the history of magnetic suspension and balance systems. Roll control, size limitations, high angle of attack, reliability, position sensing, and calibration are discussed among the problems and limitations of the existing magnetic suspension and balance systems. Examples of the existing systems are presented, and design studies for future systems are outlined. Problems specific to large-scale magnetic suspension and balance systems, such as high model loads, requirements for high-power electromagnets, high-capacity power supplies, highly sophisticated control systems and position sensors, and high costs are assessed.

Britcher, Colin P.↗

A Single-Vector Force Calibration Method Featuring the Modern Design of Experiments

This paper proposes a new concept in force balance calibration. An overview of the state-of-the-art in force balance calibration is provided with emphasis on both the load application system and the experimental design philosophy. Limitations of current systems are detailed in the areas of data quality and productivity. A unique calibration loading system integrated with formal experimental design techniques has been developed and designated as the Single-Vector Balance Calibration System (SVS). This new concept addresses the limitations of current systems. The development of a quadratic and cubic calibration design is presented. Results from experimental testing are compared and contrasted with conventional calibration systems. Analyses of data are provided that demonstrate the feasibility of this concept and provide new insights into balance calibration.

Parker, P. A.↗

SSME Investment in Turbomachinery Inducer Impeller Design Tools and Methodology

Within the rocket engine industry, SSME turbomachines are the de facto standards of success with regard to meeting aggressive performance requirements under challenging operational environments. Over the Shuttle era, SSME has invested heavily in our national inducer impeller design infrastructure. While both low and high pressure turbopump failures/anomaly resolution efforts spurred some of these investments, the SSME program was a major benefactor of key areas of turbomachinery inducer-impeller research outside of flight manifest pressures. Over the past several decades, key turbopump internal environments have been interrogated via highly instrumented hot-fire and cold-flow testing. Likewise, SSME has sponsored the advancement of time accurate and cavitating inducer impeller computation fluid dynamics (CFD) tools. These investments together have led to a better understanding of the complex internal flow fields within aggressive high performing inducers and impellers. New design tools and methodologies have evolved which intend to provide confident blade designs which strike an appropriate balance between performance and self induced load management.

Zoladz, Thomas↗

Wind Tunnel Measurements of the Wake of a Full-Scale UH-60A Rotor in Forward Flight

A full-scale UH-60A rotor was tested in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel in May 2010. The test was designed to acquire a suite of measurements to validate state-of-the-art modeling tools. Measurements include blade airloads (from a single pressure-instrumented blade), blade structural loads (strain gages), rotor performance (rotor balance and torque measurements), blade deformation (stereo-photogrammetry), and rotor wake measurements (Particle Image Velocimetry (PIV) and Retro-reflective Backward Oriented Schlieren (RBOS)). During the test, PIV measurements of flow field velocities were acquired in a stationary cross-flow plane located on the advancing side of the rotor disk at approximately 90 deg rotor azimuth. At each test condition, blade position relative to the measurement plane was varied. The region of interest (ROI) was 4-ft high by 14-ft wide and covered the outer half of the blade radius. Although PIV measurements were acquired in only one plane, much information can be gleaned by studying the rotor wake trajectory in this plane, especially when such measurements are augmented by blade airloads and RBOS data. This paper will provide a comparison between PIV and RBOS measurements of tip vortex position and vortex filament orientation for multiple rotor test conditions. Blade displacement measurements over the complete rotor disk will also be presented documenting blade-to-blade differences in tip-path-plane and providing additional information for correlation with PIV and RBOS measurements of tip vortex location. In addition, PIV measurements of tip vortex core diameter and strength will be presented. Vortex strength will be compared with measurements of maximum bound circulation on the rotor blade determined from pressure distributions obtained from 235 pressure sensors distributed over 9 radial stations.

Wadcock, Alan J.↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Automatic load sharing in inverter modules

Active feedback loads transistor equally with little power loss. Circuit is suitable for balancing modular inverters in spacecraft, computer power supplies, solar-electric power generators, and electric vehicles. Current-balancing circuit senses differences between collector current for power transistor and average value of load currents for all power transistors. Principle is effective not only in fixed duty-cycle inverters but also in converters operating at variable duty cycles.

Nagano, S.↗

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications for the residential sector. The purpose is to cover the gaps that exist in the information captured by the sensors for energy management system to be able to provide demand response and load factor control. The vision is the development of an energy management system or other controlling enterprise hardware and software that is not only able to control loads, PHEVs, and renewable generation for demand response and load factor control, but also to do so with consumer comforts in mind and in an optimal fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Approach for the Assessment of Interactions of a Strain-Gage Balance

A new approach was developed to assess interactions of a strain-gage balance. The approach compares interactions observed during a calibration of the balance with interactions observed during the application of check loads. The approach assumes that alignment errors of the calibration loads are negligible. In that case, interactions observed during the calibration can be used as a reference for the assessment of interactions of check loads. The new approach first fits interactions of a single-component load of the calibration data using simple regression models. Then, interactions of the check loads are predicted by using the check load values as inputs for the regression models of the interactions. In the next step, absolute values of differences between predicted and observed interactions of the check loads are computed. Afterwards, the largest differences are compared with empirical thresholds to assess how well the interactions of the check load data agree with the interactions of the calibration data. Recently obtained data sets of a six-component force balance are used to illustrate the application of the new approach. It is also demonstrated how knowledge of balance design characteristics can benefit the assessment of interactions.

wind tunnel test↗

Thermomechanical coupling in fatigue fracture of viscoelastic materials

Subcritical crack growth in a linear viscoelastic material subjected to cyclic loading is investigated starting with the thermodynamic power balance. Physically, it is supposed that the subcritical slow crack growth is due to local weakening of the material in the neighborhood of the crack tip. Under fatigue loading it is assumed that all energy dissipation goes into heat and that this heat build-up is the dominant irreversible process governing crack growth. The cycle averaged temperature distribution around the crack tip is obtained from local application of the first law of thermodynamics (i.e., conservation of energy). The analysis leads to the solution of a nonlinear integro-differential equation for crack length as a function of time which is coupled with the local energy equation. A regular perturbation technique is used to obtain an analytical solution which compares very well with experimental results.

Hufferd, W. L.↗

Selected advanced aerodynamics and active controls technology concepts development on a derivative B-747

The feasibility of applying wing tip extensions, winglets, and active control wing load alleviation to the Boeing 747 is investigated. Winglet aerodynamic design methods and high speed wind tunnel test results of winglets and of symmetrically deflected ailerons are presented. Structural resizing analyses to determine weight and aeroelastic twist increments for all the concepts and flutter model test results for the wing with winglets are included. Control law development, system mechanization/reliability studies, and aileron balance tab trade studies for active wing load alleviation systems are discussed. Results are presented in the form of incremental effects on L/D, structural weight, block fuel savings, stability and control, airplane price, and airline operating economics.

Source record↗