Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Load Factor and Unserved Energy Webinar

This presentation consists of slides from a webinar given on October 25, 2019. The slides give an overview of load factor forecasting and how it can be incorporated into energy and power demand forecasts, with a special eye towards accounting for unserved energy. It includes case studies from other countries, highlighting how load factor is used in their individual load forecasts. The slides then review and compare various load forecasts for Pakistan's electricity grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aeroelastic Modeling and Full-Scale Loads Measurements for Investigation of Single-Axis PV Tracker Wind-Driven Dynamic Instabilities

While wind tunnel testing and proprietary industry modeling tools have been used for years to design and develop PV tracker systems, wind induced dynamic failures are becoming more prevalent and high visibility. Designers and manufactures have reacted by developing new systems or add-on products to improve system dynamics adding to overall system costs. To better understand the physics and aeroelastic behavior that leads to dynamic instabilities NREL researches have taken up a first of a kind study to both develop open source aeroelastic modeling tools and measure tracker loads on a single axis full-scale tracker system at a high wind site. These modeling tools can simulate the fluid-structure interaction driving torsional instabilities under a wide range of turbulent inflow conditions and stow angles. The results of these simulations reveal the flow features associated with panel rotation and the induced loads in the structure. The experimental load measurements can be used to validate models and provide a quantifiable understanding of tracker dynamics, critical loads paths, identify instability markers, inform resilient design, and suggest the most favorable stow approach.

14 SOLAR ENERGY↗

2.1.2.403 - Fatigue and Structural Load Analysis and Control for Variable-Geometry Wave Energy Converters (VGWECs)

The VGWEC project will generate and disseminate the foundational knowledge enabling a paradigm shift in the design of wave energy converters (WECs) by adding a geometry control option on top of power-take-off load control. The variable-geometry modules (VGMs) provide control over a WEC's hydrodynamics that can emphasize power absorption or load shedding. Additional load shedding provided by the VGMs is expected to reduce the device structural mass and extend the sea state operating envelope, by limiting peak loading, both contributing towards reducing levelized cost of energy (LCOE) estimates.

hydrodynamic↗

Predicting Wind Loading and Instability in Solar Tracking PV Arrays

Wind loading and the fluctuating pressure loads it creates on PV panel surfaces are associated with multiple degradation mechanisms and failures. Modest wind speeds create reversing loads that can initiate cell cracks and weather cracked cells. Stronger wind speeds and extreme weather events can lead to larger scale forces and the aerodynamic instability known as torsional galloping. All these effects are dependent on the complex coupling between wind speed, panel orientation, and a myriad of other hardware and site-specific factors. In this work, we present the latest developments from our work to build an open-source, high-performance computing (HPC) fluid dynamics solver to predict and mitigate these effects. This simulation package allows users to easily specify different array layouts, solar-tracking angles, panel geometries, and weather conditions before automatically generating a refined computational mesh and solving for the unsteady loading on each panel surface. Small domains (e.g., a single panel row in isolation) can be solved on a modern laptop, while larger domains or very high-fidelity studies can be solved on distributed or HPC resources with minimal modifications to the underlying problem specification. We present preliminary case studies obtained using this simulation package and highlight how increased wind speeds combined with sub-optimal tracking angles can exacerbate degradation drivers.

aerodynamics↗

Resilient Distribution System Restoration with Equitable Load Shedding

A methodology is proposed for the improvement of electric distribution system resilience to high-impact, low-probability catastrophic events. An approach for dynamic network reconfiguration and coordination of distributed energy resources is introduced to assist in restoration efforts. The problem is formulated as a mixed-integer linear program that minimizes generation costs, the cost of lost load, and costs associated with equitable load shedding, while respecting operational limits of generation, loads, and the network. Constraints are imposed on binary switching variables to ensure equitable load shedding in emergency situations. Numerical validation of the proposed approach is conducted on an example distribution feeder, and case studies are performed to analyze the impact of various parameters in the optimization problem formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Reinforcement Learning for Distribution System Critical Load Restoration: Preprint

Grid resilience has become a critical topic recently because of the increasing occurrence of extreme events and the growing integration of intermittent renewable energy sources. To build a resilient distribution system, this paper develops a multi-agent reinforcement learning-based (MARL) method to coordinate distribution energy resources (DERs) dispatch, load pickup, and network reconfiguration for load restoration after a system outage. With the help of two types of control agents, namely critical load restoration (CLR) and coordination (COR) agents, system loads can be restored efficiently, given available resources. The effectiveness and superiority of the proposed algorithm are demonstrated through simulations and comparative studies on a real distribution feeder in Western Colorado.

distribution system↗

Innovative Solutions for Loading Smaller Standardized Dry Storage Canister Systems for Used Nuclear Fuel - 16232

An integrated team lead by EnergySolutions has developed and evaluated design concepts and loading processes for standardized transportation, aging and disposal (STAD) canister systems for the dry storage of United States (US) commercial used nuclear fuel (UNF). These STADs would be smaller than the Dual Purpose Canisters (DPCs) currently in use for storage and transportation of UNF at the nuclear power plant (NPP) sites in the US, so it was necessary to study the operational requirements and impacts related to their implementation at the NPPs and develop innovative approaches to mitigate these impacts. This work was funded by the US Department of Energy (DOE) to support the DOE in evaluating the option of using standardized canister systems for storage, transport, and disposal of US commercial UNF as part of an integrated waste management system. The NPP utilities are currently placing UNF into increasingly large DPCs because this reduces loading times and associated worker dose uptake. However, whether large DPCs may be able to be directly disposed is not known at this time, and will depend in part on future geologic disposal concepts and the DPC heat content. The use of STAD canisters rather than DPCs at the NPP sites and/or at an interim storage facility could avoid a potential need to repackage the UNF for disposal but, to make STAD canisters attractive for use, ways need to be found to fill and seal them efficiently from an operational perspective. This paper describes the generic design for a small STAD canister system, the loading processes and process improvements that were identified for the small, medium and large STAD canister sizes, the methodology for, and results from, the assessment of the performance of the loading processes, and the practicality of the results versus NPP operating experience. The work that this paper reports thus reflects research and development efforts to explore technical concepts that could support future decision-making by DOE. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large Load Integration - Task List and Overview

Large Load Integration Tasks: Task 1 – Workshops Support stakeholder engagement across industry to promote collaboration and identify solutions to challenges that will guide other work Task 2 – Ancillary Services Characterize different types of large loads to assess under what conditions they may be utilized to provide grid stability services Task 3 – Communications Explore the cybersecurity and communications infrastructure required to enable large loads to interface with grid operations to provide ancillary services Task 4 – Nuclear Integration Explore risks and methods for supporting large load energy needs with SMRs and incorporating them into the wider power system Task 5 – Decision Support and TA Provide support to stakeholders through the creation of planning tools and direct technical assistance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Spinning Reserve from Hotel Air Conditioning Load - SHORT VERSION

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An air-Brayton nuclear-hydrogen combined-cycle peak-and base-load electric plant

A combined-cycle power plant is proposed that uses heat from a high-temperature nuclear reactor and hydrogen produced by the high-temperature reactor to meet base-load and peak-load electrical demands. For base-load electricity production, air is compressed; flows through a heat exchanger, where it is heated to between 700 and 900 C; and exits through a high-temperature gas turbine to produce electricity. The heat, via an intermediate heat-transport loop, is provided by a high-temperature reactor. The hot exhaust from the Brayton-cycle turbine is then fed to a heat recovery steam generator that provides steam to a steam turbine for added electrical power production. To meet peak electricity demand, after nuclear heating of the compressed air, hydrogen is injected into the combustion chamber, combusts, and heats the air to 1300 C-the operating conditions for a standard natural-gas-fired combined-cycle plant. This process increases the plant efficiency and power output. Hydrogen is produced at night by electrolysis or other methods using energy from the nuclear reactor and is stored until needed. Therefore, the electricity output to the electric grid can vary from zero (i.e., when hydrogen is being produced) to the maximum peak power while the nuclear reactor operates at constant load. Because nuclear heat raises air temperatures above the auto-ignition temperatures of the hydrogen and powers the air compressor, the power output can be varied rapidly (compared with the capabilities of fossil-fired turbines) to meet spinning reserve requirements and stabilize the grid.

08 HYDROGEN↗

Impact of Filtration Velocities and Particulate Matter Characteristics on Diesel Particulate Filter Wall Loading Performance

The impact of different types of diesel particulate matter (PM) and different sampling conditions on the wall deposition and early soot cake build up within diesel particulate filters has been investigated. The measurements were made possible by a newly developed Diesel Exhaust Filtration Analysis (DEFA) system in which in-situ diesel exhaust filtration can be reproduced with in small cordierite wafer disks, which are essentially thin sections of a Diesel Particulate Filter (DPF) wall. The different types of PM were generated from selected engine operating conditions of a single-cylinder heavy-duty diesel engine. Two filtration velocities 4 and 8 cm/s were used to investigate PM deep-bed filtration processes. The loaded wafers were then analyzed in a thermal mass analyzer that measures the Soluble Organic Fraction (SOF) as well as soot and sulfate fractions of the PM. In addition, the soot residing in the wall of the wafer was examined under an optical microscope illuminated with Ultraviolet light and an Environmental Scanning Electron Microscope (E-SEM) to determine the bulk soot penetration depth for each loading condition. It was found that higher filtration velocity results in higher wall loading with approximately the same penetration depth into the wall. PM characteristics impacted both wall loading and soot cake layer characteristics. Results from imaging analysis indicate that soot the penetration depth into the wall was affected more by PM size (which changes with engine operating conditions) rather than filtration velocity.

33 ADVANCED PROPULSION SYSTEMS↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultrahigh-Loading Manganese-Based Electrodes for Aqueous Batteries via Polymorph Tuning

Manganese-based aqueous batteries utilizing Mn 2+ /MnO 2 redox reactions are promising choices for grid-scale energy storage due to their high theoretical specific capacity, high power capability, low-cost, and intrinsic safety with water-based electrolytes. However, the application of such systems is hindered by the insulating nature of deposited MnO 2 , resulting in low normalized areal loading (0.005–0.05 mAh cm -2 ) during the charge/discharge cycle. Here, in this work, the electrochemical performance of various MnO 2 polymorphs in Mn 2+ /MnO 2 redox reactions is investigated, and ε-MnO 2 with low conductivity is determined to be the primary electrochemically deposited phase in normal acidic aqueous electrolyte. It is found that increasing the temperature can change the deposited phase from ε-MnO 2 with low conductivity to γ-MnO 2 with two order of magnitude increase in conductivity. It is demonstrated that the highly conductive γ-MnO 2 can be effectively exploited for ultrahigh areal loading electrode, and a normalized areal loading of 33 mAh cm -2 is achieved. At a mild temperature of 50 °C, cells are cycled with an ultrahigh areal loading of 20 mAh cm -2 (1–2 orders of magnitude higher than previous studies) for over 200 cycles with only 13% capacity loss.

25 ENERGY STORAGE↗

Peptoid-Loaded Microgels Self-Defensively Inhibit Staphylococcal Colonization of Titanium in a Model of Operating-Room Contamination

Bacterial contamination of an exposed implantable medical device by the atmosphere of an operating room (OR) is increasingly implicated as a cause of device-associated infection. Here, OR contamination is modeled in vitro using an aerosolizing system to spray small quantities of staphylococci onto titanium rods. Contaminated rods always manifest culturable bacteria. Self-assembly is used to create a self-defensive Ti surface that substantially enhances the rod's resistance to such contamination. Poly(acrylic acid) microgels are electrostatically deposited onto small Ti rods and subsequently loaded by complexation with a cationic antimicrobial peptoid (TM1). The microgels are visualized in situ by optical microscopy, and changes in microgel diameter indicate the loading state. Further, these measurements show that TM1 can be quickly loaded from low-ionic-strength buffer and subsequently remained sequestered within the microgels for up to 4 weeks when soaked in phosphate buffered saline. TM1-loaded microgel-modified Ti surfaces are contaminated with aerosolized staphylococci, and subsequent assays indicate few or no culturable bacteria. In the absence of nutrients to enable metabolism, this finding suggests that bacteria trigger local TM1 release by contact transfer. The modified surfaces exhibit good in vitro cytocompatibility as manifested by the adhesion, spreading, and metabolic activity of human fetal osteoblasts.

36 MATERIALS SCIENCE↗

3D-Printed Graded Electrode with Ultrahigh MnO 2 Loading for Non-Aqueous Electrochemical Energy Storage

Electrolytic manganese dioxide is one of the promising cathode candidates for electrochemical energy storage devices due to its high redox capacity and ease of synthesis. Yet, high-loading MnO 2 often suffers from sluggish reaction kinetics, especially in non-aqueous electrolytes. The non-uniform deposition of MnO 2 on a porous current collectors also makes it difficult to fully utilize the active materials at high mass loading. Here, a 3D printed graded graphene aerogel (3D GA) that contains sparsely separated exterior ligaments is developed to create large open channels for mass transport as well as densely arranged interior ligaments providing large ion-accessible active surface. The unique structural design homogenizes the thickness of electro deposited MnO 2 even at an ultrahigh mass loading of ≈70 mg cm -2 . The electrode achieves a remarkable volumetric capacity of 29.1 mA h cm -3 in the non-aqueous electrolyte. A Li-ion hybrid capacitor device assembled with a graded 3D GA/MnO2 cathode and graded 3D GA/VO x anode exhibits a wide voltage window of 0–4 V and a superior volumetric energy density of 20.2 W h L -1 . The findings offer guidance on 3D printed electrode design for supporting ultrahigh loading of active materials and developments of high energy density energy storage devices.

electrochemical energy storage↗