Control of magnetic relaxation by electric-field-induced ferroelectric phase transition and inhomogeneous domain switching

Electric-field modulation of magnetism in strain-mediated multiferroic heterostructures is considered a promising scheme for enabling memory and magnetic microwave devices with ultralow power consumption. However, it is not well understood how electric-field-induced strain influences magnetic relaxation, an important physical process for device applications. Here, we investigate resonant magnetization dynamics in ferromagnet/ferroelectric multiferroic heterostructures, FeGaB/PMN-PT and NiFe/PMN-PT, in two distinct strain states provided by electric-field-induced ferroelectric phase transition. The strain not only modifies magnetic anisotropy but also magnetic relaxation. In FeGaB/PMN-PT, we observe a nearly two-fold change in intrinsic Gilbert damping by electric field, which is attributed to strain-induced tuning of spin-orbit coupling. By contrast, a small but measurable change in extrinsic linewidth broadening is attributed to inhomogeneous ferroelastic domain switching during the phase transition of the PMN-PT substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale Quantum Imaging of Field-Free Deterministic Switching of a Chiral Antiferromagnet

Recently, unconventional spin-orbit torques (SOTs) with tunable spin generation have opened new pathways for designing novel magnetization control for cutting-edge spintronics innovations. A leading research thrust is to develop field-free deterministic magnetization switching for implementing scalable and energy favorable magnetic recording and storage, which have been demonstrated in conventional ferromagnetic and antiferromagnetic material systems. Here, in this work, we extend this advanced magnetization control strategy to chiral antiferromagnet Mn 3 ⁢Sn using spin currents with out-of-plane canted polarization generated from low-symmetry van der Waals (vdW) material WTe 2 . Numerical calculations suggest that dampinglike SOT of spins injected perpendicular to the kagome plane of Mn 3⁢ Sn serves as a driving force to rotate the chiral magnetic order, while the fieldlike SOT of spin currents with polarization parallel to the kagome plane provides the bipolar deterministicity to the magnetic switching in the absence of an external magnetic field. We further introduce scanning quantum microscopy to visualize nanoscale evolutions of Mn 3 ⁢Sn magnetic domains during the field-free switching process, corroborating the exceptionally large magnetic switching ratio up to 90%. Our results highlight the opportunities provided by hybrid SOT material platforms consisting of noncollinear antiferromagnets and low-symmetry vdW spin source materials for developing next-generation spintronic logic devices.

2-dimesional systems↗

Scorpius Injector Solenoid Magnet Alignment and Characterization

The Scorpius project consists of a linear induction accelerator (LIA) that will be built in the coming few years at the Nevada test site. Large radius solenoid magnets are used to focus and transport the electron beam through the injector of Scorpius. Typically, solenoid magnets are wrapped directly around the beam pipe. They have an inner radius of about 8 cm and weight approximately 170 lbs. The magnets for the Scorpius injector are much larger, the largest of which extends to an inner radius of 45 cm with a weight of 709 lbs. In addition, the magnet measurement effort is typically time-consuming, taking several months to complete. With 5 different designs of 52 solenoid magnets to measure in under a year, this is a challenging undertaking that requires a systems solution. Due to the size, variability, and quantity of solenoid magnets, as well as the compressed schedule, the process of measuring the solenoid magnets before integrating them into their respective assemblies and shipping them to Nevada is a challenging problem. There is a need for the injector magnets to be characterized and aligned in preparation for the commissioning of Scorpius. This will ensure that the injector magnet installation meets requirements.

42 ENGINEERING↗

The cation inversion and magnetization in nanopowder zinc ferrite obtained by soft mechanochemical processing

Graphical abstract: - Highlights: • Nano powder of ZnFe{sub 2}O{sub 4} prepared by a soft mechanochemical route after 18 h milling. • Phase formation controlled by XRD, Raman spectroscopy and magnetic measurements. • Size, strain and cation inversion degree determined by Rietveld refinement. • We were able to estimate the degree of inversion at most 0.348 and 0.4. • Obtained extremely high values of saturation magnetizations at T = 4.5 K. - Abstract: Two zinc ferrite nanoparticle materials were prepared by the same method – soft mechanochemical synthesis, but starting from different powder mixtures: (1) Zn(OH){sub 2}/α-Fe{sub 2}O{sub 3} and (2) Zn(OH){sub 2}/Fe(OH){sub 3}. In both cases a single phase system was obtained after 18 h of milling. The progress of the synthesis was controlled by X-ray diffractometry (XRD), Raman spectroscopy, TEM and magnetic measurements. Analysis of the XRD patterns by Rietveld refinement allowed determination of the cation inversion degree for both obtained single phase ZnFe{sub 2}O{sub 4} samples. The sample obtained from mixture (1) has the cation inversion degree 0.3482 and the sample obtained from mixture (2) 0.400. Magnetization measurements were confirmed that the degrees of the inversion were well estimated. Comparison with published data shows that used method of synthesis gives nano powder samples with extremely high values of saturation magnetizations: sample (1) 78.3 emu g{sup −1} and sample (2) 91.5 emu g{sup −1} at T = 4.5 K.

36 MATERIALS SCIENCE↗

Extremely large d 0 magnetism in krypton implanted polar ZnO films

Magnetization is produced in samples of ZnO by implanting krypton ions. Krypton is chemically inert; hence, the magnetization is the consequence of the radiation damage that occurred due to the implantation process. We have found magnetization as large as 185 emu cm –3 at room temperature which corresponds to a moment of ~40 Bohr magnetons per implanted krypton ion. The results are compared for implantation into different ZnO samples, O- and Zn-polar thin films and thin ZnO crystal wafers. The structure of the films has been investigated using RHEED, AFM, XRD and EXAFS. The O-polar film grew in a layer-by-layer mode and after implantation, its lattice spacing increased and the grain size decreased which indicated that the Kr atoms had been incorporated into the lattice. In contrast the Zn-polar film grew in a Stranski–Krastanov mode and its lattice spacing and grain size were almost unchanged by the implantation indicating that the Kr atoms were in the grain boundaries. Raman scattering is used to characterize the radiation damage and to identify scattering from amorphous regions in the grain boundaries and the scattering from point defects. The largest magnetization is found in the O-polar ZnO films where there is a marked grain fragmentation, leading to an increase in the volume of the sample occupied by grain boundaries. As a result, the increase in the number of point defects, which was identified by Raman scattering for films of both polarity, was less effective at producing a magnetic signal than the grain boundaries.

36 MATERIALS SCIENCE↗

On Lorentz invariants in relativistic magnetic reconnection

Lorentz invariants whose nonrelativistic correspondences play important roles in magnetic reconnection are discussed in this paper. Particularly, the relativistic invariant of the magnetic reconnection rate is defined and investigated in a covariant two-fluid model. Certain Lorentz covariant representations for energy conversion and magnetic structures in reconnection processes are also investigated. Furthermore, relativistic measures for topological features of reconnection sites, particularly magnetic nulls and separatrices, are analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magic ultramagnetized nuclei in explosive nucleosynthesis

Direct evidence of the presence of {sup 44}Ti and content of the isotope in the supernova remnant Cassiopeia A are obtained from the analysis of gamma-ray spectrum of the remnant. A significant excess of observational {sup 44}Ti volume on predictions of supernova models can be explained as the magnetization effect in the process of explosive nucleosynthesis. The formation of chemical elements is considered accounting for superstrong magnetic fields predicted for supernovae and neutron stars. Using the arguments of nuclear statistical equilibrium, a significant effect of magnetic field on the nuclear shell energy is demonstrated. The magnetic shift of the most tightly 'bound' nuclei from the transition metals of iron series to titanium leads to an exponential increase in the portion of {sup 44}Ti and, accordingly to a significant excess of the yield of these products of nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics of gamma-ray bursts

Attention is given to the accumulating evidence for the view that gamma-ray bursts come from strongly magnetic neutron stars, discussing the physical properties of the emission region and the radiation processes expected in strong magnetic fields, and emphasizing that the observed burst spectra require that the emission region be optically thin. This entails that the energy of the emitting plasma and/or the plasma itself be continuously replenished during a burst, and that the cooling time scale of the emitting plasma be much shorter than the observed duration of the bursts. This characteristic of the cooling time scale implies that the burst intensity and spectrum can vary on extremely short time scales, and that the burst duration must have a separate explanation. It is emphasized that synchrotron emission is favored as the gamma-ray production mechanism; it is the only mechanism capable of satisfying the optical thinness constraint while producing the observed luminosity.

Lamb, D. Q.↗

Development of Numerical Tools for the Investigation of Plasma Detachment from Magnetic Nozzles

A multidimensional numerical simulation framework aimed at investigating the process of plasma detachment from a magnetic nozzle is introduced. An existing numerical code based on a magnetohydrodynamic formulation of the plasma flow equations that accounts for various dispersive and dissipative processes in plasmas was significantly enhanced to allow for the modeling of axisymmetric domains containing three.dimensiunai momentum and magnetic flux vectors. A separate magnetostatic solver was used to simulate the applied magnetic field topologies found in various nozzle experiments. Numerical results from a magnetic diffusion test problem in which all three components of the magnetic field were present exhibit excellent quantitative agreement with the analytical solution, and the lack of numerical instabilities due to fluctuations in the value of del(raised dot)B indicate that the conservative MHD framework with dissipative effects is well-suited for multi-dimensional analysis of magnetic nozzles. Further studies will focus on modeling literature experiments both for the purpose of code validation and to extract physical insight regarding the mechanisms driving detachment.

Sankaran, Kamesh↗

Towards an electro-magnetic field separation of deposited material implemented in an ion beam sputter process

Nowadays, Ion Beam Sputter (IBS) processes are very well optimized on an empirical basis. To achieve further progresses, a modification of the IBS process by guiding the coating material using an axial magnetic field and an additional electrical field has been studied. The electro-magnetic (EM) field leads to a significant change in plasma properties and deposition rate distributions, whereas an increase in deposition rate along the centerline of the axial EM field around 150% was observed. These fundamental studies on the prototype are the basis for the development of an applicable and workable design of a separation device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LCLS-II Cryomodule Production at JLAB

The LCLS-II cryomodule construction program leverages the mature XFEL cryomodule design to produce technologically sophisticated cryomodules with a minimum of R&D according to an accelerated manufacturing schedule. Jlab, as one of the partner labs, is producing 18 cryomodules for LCLS-II. To meet the quality and schedule demands of LCLS-II, many upgrades to the JLAB cryomodule assembly infrastructure and techniques have been made. JLab has installed a new cleanroom for string assembly and instituted new protocols to minimize particulate transfer into the cavities during the cryomodule construction process. JLab has also instituted a set of magnetic hygiene protocols to be used during the assembly process to minimize magnetic field impingement on the finished cavity structure. The goal has been to have gradients, both maximum and field emission onset, that do not degrade between the cavity vertical test and final cryomodule qualification, while maximizing the Q0 of each finished cavity. Results from the prototype and first production cryomodule assembly are presented.

Davis, Giles↗

Fission and fusion scenarios for magnetic microswimmer clusters

Fission and fusion processes of particle clusters occur in many areas of physics and chemistry from subnuclear to astronomic length scales. Here we study fission and fusion of magnetic microswimmer clusters as governed by their hydrodynamic and dipolar interactions. Rich scenarios are found that depend crucially on whether the swimmer is a pusher or a puller. In particular a linear magnetic chain of pullers is stable while a pusher chain shows a cascade of fission (or disassembly) processes as the self-propulsion velocity is increased. Contrarily, magnetic ring clusters show fission for any type of swimmer. Moreover, we find a plethora of possible fusion (or assembly) scenarios if a single swimmer collides with a ringlike cluster and two rings spontaneously collide. Lastly, our predictions are obtained by computer simulations and verifiable in experiments on active colloidal Janus particles and magnetotactic bacteria.

36 MATERIALS SCIENCE↗

Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring

Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated inin vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone–tissue and air–tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and thein vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the nominal and measured cases, respectively. For air the corresponding figures were 0.991 and 0.993. Compared to an unattenuated reference image, the mean error in simulated PET uptake in the brain was 9.16% when AC maps derived from nominal trajectories was used, with errors in the SUV{sub max} for simulated lesions in the range of 7.17%–12.19%. Corresponding figures when AC maps derived from measured trajectories were used were 0.34% (mean error) and −0.21% to +1.81% (lesions). Conclusions: Eddy current artifacts in UTE imaging can be corrected for by measuring the true k-space trajectories during a calibration scan and using them in subsequent image reconstructions. This improves the accuracy of segmented PET attenuation maps derived from UTE sequences and subsequent PET reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spurious poles in the scattering of electric and magnetic charges

Theories with both electric and magnetic charges (“mutually non-local” theories) have several major obstacles to calculating scattering amplitudes. Even when the interaction arises through the kinetic mixing of two, otherwise independent, U(1)’s, so that all low-energy interactions are perturbative, difficulties remain: using a self-dual, local formalism leads to spurious poles at any finite order in perturbation theory. Correct calculations must show how the spurious poles cancel in observable scattering amplitudes. Consistency requires that one type of charge is confined as a result of one of the U(1)’s being broken. Here we show how the constraints of confinement and parity conservation on observable processes manages to cancel the spurious poles in scattering and pair production amplitudes, paving the way for systematic studies of the experimental signatures of “dark” electric-magnetic processes. Along the way we demonstrate some novel effects in electric-magnetic interactions, including that the amplitude for single photon production of magnetic particles by electric particles vanishes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Formation of multilayered magnetic nanotracks with perpendicular anisotropy via deoxidization using ion irradiation on ultraviolet-imprinted intaglio nanostructures

We proposed a method to fabricate perpendicular magnetic nanotracks in the cobalt oxide/palladium multilayer films using UV-nanoimprinting lithography and low-energy hydrogen-ion irradiation. This is a method to magnetize UV-imprinted intaglio nanotracks via low-energy hydrogen ion irradiation, resulting the irradiated region are magnetically separated from the non-irradiated region. Multilayered magnetic nanotracks with a line width of 140 nm, which were fabricated by this parallel process without additional dry etching process, exhibited a saturation magnetization of 290 emu cm{sup −3} and a coercivity of 2 kOe. This study demonstrates a cost-effective mass production of multilayered perpendicular magnetic nanotracks and offers the possibility to achieve high density storage and memory devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dipole Bend Magnets: Design Considerations

This analysis provides a design of a dipole bend magnet for a beamline, stepping through various considerations while assembling a design. This report can be used as a basis of a bending dipole magnet applicable to LANSCE, a scalable point design for other applications, or as a systematic process for developing a magnet design from scratch. The goal is more to answer, 'Is it reasonable?' than to address correction factors. In this specific case, the dipole should provide 3 kG within a 6.35-cm (2.5") gap across an area provided by 25×15-cm pole pieces. This provides roughly 17° and 21° deflection for proton at 3.0 and 2.1 MeV, respectively.

43 PARTICLE ACCELERATORS↗

Energy released by the interaction of coronal magnetic fields

Comparisons between coronal spectroheliograms and photospheric magnetograms are presented to support the idea that as coronal magnetic fields interact, a process of field-line reconnection usually takes place as a natural way of preventing magnetic stresses from building up in the lower corona. This suggests that the energy which would have been stored in stressed fields is continuously released as kinetic energy of material being driven aside to make way for the reconnecting fields. However, this kinetic energy is negligible compared with the thermal energy of the coronal plasma. Therefore, it appears that these slow adjustments of coronal magnetic fields cannot account for even the normal heating of the corona, much less the energetic events associated with solar flares.