Search NASA⌕ Search

SEARCH · Search NASA

Results for “methods - statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.

60 APPLIED LIFE SCIENCES↗

Characterizing the marker-dye correction for Gafchromic EBT2 film: A comparison of three analysis methods

Purpose: Gafchromic EBT2 film has a yellow marker dye incorporated into the active layer of the film that can be used to correct the film response for small variations in thickness. This work characterizes the effect of the marker-dye correction on the uniformity and uncertainty of dose measurements with EBT2 film. The effect of variations in time postexposure on the uniformity of EBT2 is also investigated. Methods: EBT2 films were used to measure the flatness of a {sup 60}Co field to provide a high-spatial resolution evaluation of the film uniformity. As a reference, the flatness of the {sup 60}Co field was also measured with Kodak EDR2 films. The EBT2 films were digitized with a flatbed document scanner 24, 48, and 72 h postexposure, and the images were analyzed using three methods: (1) the manufacturer-recommended marker-dye correction, (2) an in-house marker-dye correction, and (3) a net optical density (OD) measurement in the red color channel. The field flatness was calculated from orthogonal profiles through the center of the field using each analysis method, and the results were compared with the EDR2 measurements. Uncertainty was propagated through a dose calculation for each analysis method. The change in the measured field flatness for increasing times postexposure was also determined. Results: Both marker-dye correction methods improved the field flatness measured with EBT2 film relative to the net OD method, with a maximum improvement of 1% using the manufacturer-recommended correction. However, the manufacturer-recommended correction also resulted in a dose uncertainty an order of magnitude greater than the other two methods. The in-house marker-dye correction lowered the dose uncertainty relative to the net OD method. The measured field flatness did not exhibit any unidirectional change with increasing time postexposure and showed a maximum change of 0.3%. Conclusions: The marker dye in EBT2 can be used to improve the response uniformity of the film. Depending on the film analysis method used, however, application of a marker-dye correction can improve or degrade the dose uncertainty relative to the net OD method. The uniformity of EBT2 was found to be independent of the time postexposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A characterization of robust radiation therapy treatment planning methods-from expected value to worst case optimization

Purpose: To characterize a class of optimization formulations used to handle systematic and random errors in radiation therapy, and to study the differences between the methods within this class. Methods: The class of robust methods that can be formulated as minimax stochastic programs is studied. This class generalizes many previously used methods, ranging between optimization of the expected and the worst case objective value. The robust methods are used to plan intensity-modulated proton therapy (IMPT) treatments for a case subject to systematic setup and range errors, random setup errors with and without uncertain probability distribution, and combinations thereof. As reference, plans resulting from a conventional method that uses a margin to account for errors are shown. Results: For all types of errors, target coverage robustness increased with the conservativeness of the method. For systematic errors, best case organ at risk (OAR) doses increased and worst case doses decreased with the conservativeness. Accounting for random errors of fixed probability distribution resulted in heterogeneous dose. The heterogeneities were reduced when uncertainty in the probability distribution was accounted for. Doing so, the OAR doses decreased with the conservativeness. All robust methods studied resulted in more robust target coverage and lower OAR doses than the conventional method. Conclusions: Accounting for uncertainties is essential to ensure plan quality in complex radiation therapy such as IMPT. The utilization of more information than conventional in the optimization can lead to robust target coverage and low OAR doses. Increased target coverage robustness can be achieved by more conservative methods.

60 APPLIED LIFE SCIENCES↗

SU-E-T-484: A New Method of Aligning Patient Setup Lasers in Radiation Therapy

Purpose: To develop a new method to align the patient setup lasers in radiation therapy and examine its validity and effectiveness. Methods: The new laser alignment method was realized by a device composed of both a metallic base plate and few acrylic transparent plates with a cross hair line on each of them. The holders of radiochromic films were prepared in the device to find a radiation isocenter. The right laser positions could be found optically by matching the shadows of all the cross hairs in the gantry head and the device. The repeatability and reproducibility (R and R) of laser alignments and the dependency of the alignment on the position error of the light source were evaluated by comparing the standard deviations and the means of the measured laser positions. After aligning the lasers optically, a radiation isocenter was found by a collimator spoke shot and the gantry spoke shot, and then the lasers were parallely translated to the isocenter. Results: In the R and R test, the standard deviation was 1.14 mm for the new method whereas it was 1.49 mm or 2.76 mm for the conventional method with either high- or low-precision levels. In the test of the dependency on the position error of the light source, the mean laser position was shifted by 5.3 mm corresponding to the shift of the light source, 4.8 mm for the new method, but for the conventional method the laser position was shifted more than 7 times than that. The positional shift could be corrected by a parallel translation to the isocenter in the new method. Conclusion: A new laser alignment method was devised for radiation therapy and tested successfully. The method enabled us to align the lasers easily and accurately without repetition, and all lasers could be finally aligned to the radiation isocenter.

60 APPLIED LIFE SCIENCES↗

A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.

60 APPLIED LIFE SCIENCES↗

Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements

Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification in the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.

60 APPLIED LIFE SCIENCES↗

SU-E-T-57: A Novel Method to Improve Dose Heterogeneity of Target and Organs at Risk Sparing in the Intensity-Modulated Radiotherapy for Stage III Lung Cancer

Purpose: Intensity-modulated radiotherapy (IMRT) treatment for lung cancer is difficult due to the heterogeneous dose distribution and excessive dose to the organs at risk (OARs). We introduce a simple method based on the base dose function (BDF) in Eclipse treatment planning system to overcome the difficulties. Methods: Thirteen patients suffered from stage III non-small cell lung cancer (NSCLC) were enrolled in the study. Three kinds of approaches were applied to obtain clinically acceptable treatment plans: 1) conventionally optimizing method with hot and cold spots re-optimization (CO); 2) target-divided optimizing method (TDO) in which the optimization objective in the lung density of planning target volume (PTV) was set to 2 to 4 Gy higher than in the soft tissue density; 3) base dose function (BDF) in which the treatment plan was produced based on the original plan for re-optimization. CO, TDO and BDF methods were then compared in terms of conformity index (CI), homogeneity index (HI), OARs sparing and monitor units (MUs). Additionally, delta4, portal dosimetry and IMSure were used to measure the dose delivering accuracy. Results: The BDF technique provided more superior CI and HI than the other two methods. Moreover, the new method also reduced the lung, esophagus, heart and spinal cord dose. However, the BDF plans needed extra 15% and 10% MUs than the CO and TDO methods. Dose verification results demonstrated good and comparable γ pass rates among the three methods. Conclusion: The proposed BDF method greatly improves the dose homogeneity and OARs sparing in the IMRT treatment for lung cancer.

60 APPLIED LIFE SCIENCES↗

SU-F-T-192: Study of Robustness Analysis Method of Multiple Field Optimized IMPT Plans for Head & Neck Patients

Purpose: Proton therapy is more sensitive to uncertainties than photon treatments due to protons’ finite range depending on the tissue density. Worst case scenario (WCS) method originally proposed by Lomax has been adopted in our institute for robustness analysis of IMPT plans. This work demonstrates that WCS method is sufficient enough to take into account of the uncertainties which could be encountered during daily clinical treatment. Methods: A fast and approximate dose calculation method is developed to calculate the dose for the IMPT plan under different setup and range uncertainties. Effects of two factors, inversed square factor and range uncertainty, are explored. WCS robustness analysis method was evaluated using this fast dose calculation method. The worst-case dose distribution was generated by shifting isocenter by 3 mm along x,y and z directions and modifying stopping power ratios by ±3.5%. 1000 randomly perturbed cases in proton range and x, yz directions were created and the corresponding dose distributions were calculated using this approximated method. DVH and dosimetric indexes of all 1000 perturbed cases were calculated and compared with the result using worst case scenario method. Results: The distributions of dosimetric indexes of 1000 perturbed cases were generated and compared with the results using worst case scenario. For D95 of CTVs, at least 97% of 1000 perturbed cases show higher values than the one of worst case scenario. For D5 of CTVs, at least 98% of perturbed cases have lower values than worst case scenario. Conclusion: By extensively calculating the dose distributions under random uncertainties, WCS method was verified to be reliable in evaluating the robustness level of MFO IMPT plans of H&N patients. The extensively sampling approach using fast approximated method could be used in evaluating the effects of different factors on the robustness level of IMPT plans in the future.

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-01: A New Fabrication Method for Secondary Skin Collimation Using 3D Scanner and 3D Printer

Purpose: Using secondary skin collimation (SSC) to protect the critical organ surrounding the tumors is always desirable for electron and/or ortho-voltage treatments. However, the time-consuming and labor-intensive fabrication processes of current method (manually fabricate the lead mask) restrict the general use of SSC. The aim of this study is to develop a new SSC fabrication method using 3D scanning and 3D printing technologies in order to largely decrease the human labor involvement and fabrication time, also improve the fabrication accuracy. Methods: First, the patient surface was scanned with a 3D scanner (Structure Sensor, Occipital, CO). The raw scan data was subsequently transferred to a 3D modeling software (Rhinoceros, Ver. 5.0, McNeel North America, Seattle, WA). The tumor contour was then digitized and shielding region was determined by clinicians in the same software. The corresponding SCC conformed to the skin surface was then automatically generated by the software with the proper shielding thickness. The shell of the SCC (with hollow inside) was consequently printed by a 3D printer (Lulzbot TAZ, Aleph Objects, CO) using plastic material. Finally, the hollow mold of SCC was filled up with a melted cerrobend alloy. Once the cerrobend alloy cooled down, the fabrication of SCC was accomplished. Results: The results indicated the proposed method can achieve a much shorter time on making a SCC compared with tradition fabrication method. The processes of making a skin contour model for patients have been eliminated with the new method. SCC created by the new method possessed better accuracy and better conformality to patient’s skin contours. Conclusion: In this study, we have demonstrated a new method for the SCC fabrication. It is anticipated that our method can be an alternative way to replace conventional manual-based methods for electron and/or ortho-voltage SCC fabrication. This research was supported by the Global Ph.D. Fellowship Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (Grant No. 2015H1A2A1034071), Republic of Korea.

60 APPLIED LIFE SCIENCES↗

Examination of Hydrate Formation Methods: Trying to Create Representative Samples

Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method, contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method, water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand. In the dissolved gas method, water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming. In another version of this technique, a specified quantity of gas is placed in a sample, then the sample is flooded with water and cooled. We have performed a number of tests in which hydrate was formed and the uniformity of the hydrate formation was examined. These tests have primarily used a variety of modifications of the excess gas method to make the hydrate, although we have also used a version of the excess water technique. Early on, we found difficulties in creating uniform samples with a particular sand/ initial water saturation combination (F-110 Sand, ~ 35% initial water saturation). In many of our tests we selected this combination intentionally to determine whether we could use a method to make the samples uniform. The following methods were examined: • Excess gas, • Freeze/thaw/form, • Freeze/pressurize/thaw, • Excess gas followed by water saturation, • Excess water, • Sand and kaolinite, • Use of a nucleation enhancer (SnoMax), and • Use of salt in the water. Below, each method, the underlying hypothesis, and our results are briefly presented, followed by a brief conclusion. Many of the hypotheses investigated are not our own, but were presented to us. Much of the data presented is from x-ray CT scanning our samples. The x-ray CT scanner provides a three-dimensional density map of our samples. From this map and the physics that is occurring in our samples, we are able to gain an understanding of the spatial nature of the processes that occur, and attribute them to the locations where they occur.

03 NATURAL GAS↗

Study of Particle Rotation Effect in Gas-Solid Flows using Direct Numerical Simulation with a Lattice Boltzmann Method

A new and efficient direct numerical method with second-order convergence accuracy was developed for fully resolved simulations of incompressible viscous flows laden with rigid particles. The method combines the state-of-the-art immersed boundary method (IBM), the multi-direct forcing method, and the lattice Boltzmann method (LBM). First, the multi-direct forcing method is adopted in the improved IBM to better approximate the no-slip/no-penetration (ns/np) condition on the surface of particles. Second, a slight retraction of the Lagrangian grid from the surface towards the interior of particles with a fraction of the Eulerian grid spacing helps increase the convergence accuracy of the method. An over-relaxation technique in the procedure of multi-direct forcing method and the classical fourth order Runge-Kutta scheme in the coupled fluid-particle interaction were applied. The use of the classical fourth order Runge-Kutta scheme helps the overall IB-LBM achieve the second order accuracy and provides more accurate predictions of the translational and rotational motion of particles. The preexistent code with the first-order convergence rate is updated so that the updated new code can resolve the translational and rotational motion of particles with the second-order convergence rate. The updated code has been validated with several benchmark applications. The efficiency of IBM and thus the efficiency of IB-LBM were improved by reducing the number of the Lagragian markers on particles by using a new formula for the number of Lagrangian markers on particle surfaces. The immersed boundary-lattice Boltzmann method (IBLBM) has been shown to predict correctly the angular velocity of a particle. Prior to examining drag force exerted on a cluster of particles, the updated IB-LBM code along with the new formula for the number of Lagrangian markers has been further validated by solving several theoretical problems. Moreover, the unsteadiness of the drag force is examined when a fluid is accelerated from rest by a constant average pressure gradient toward a steady Stokes flow. The simulation results agree well with the theories for the short- and long-time behavior of the drag force. Flows through non-rotational and rotational spheres in simple cubic arrays and random arrays are simulated over the entire range of packing fractions, and both low and moderate particle Reynolds numbers to compare the simulated results with the literature results and develop a new drag force formula, a new lift force formula, and a new torque formula. Random arrays of solid particles in fluids are generated with Monte Carlo procedure and Zinchenko's method to avoid crystallization of solid particles over high solid volume fractions. A new drag force formula was developed with extensive simulated results to be closely applicable to real processes over the entire range of packing fractions and both low and moderate particle Reynolds numbers. The simulation results indicate that the drag force is barely affected by rotational Reynolds numbers. Drag force is basically unchanged as the angle of the rotating axis varies.

36 MATERIALS SCIENCE↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt or SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Materials Characterization, Prediction, and Control Project: Characterization of 316L Stainless Steel after Solid Phase Processing using Ultrasonic NDE Method

The Pacific Northwest National Laboratory undertook the Materials Characterization, Prediction, and Control Laboratory Directed Research and Development Project to advance understanding of nuclear material processing and enable multifold acceleration in the development and qualification of new material systems produced via advanced manufacturing methods, such as solid phase processing, for use in national security and advanced energy applications (Smith 2021). A motivation of the Materials Characterization, Prediction, and Control Project was to demonstrate ultrasonic testing as a nondestructive evaluation method to complement traditional destructive methods for characterizing material microstructure with emphasis on grain size determination using a method that may have future applications for real-time inline process monitoring. The objective of the work described in this report is to establish the process and an analysis method for measuring grain sizes of polycrystalline metals with ultrafine grains using ultrasonic shear wave backscattering, building on prior studies on coarser-grained material. The work involves five tasks: Measured ultrasonic backscattering experimentally for a series of 316L stainless steel specimens with various grain sizes made by friction stir processing. Calculated ultrasonic backscattering coefficients from experimental data based on a physical measurement model. Measured ground truth grain sizes of the specimens from electron backscatter diffraction grain boundary images using a generalization of the ASTM E112 (ASTM 2021) intercept method. Built a curve of ultrasonic backscattering coefficients versus the ground truth intercept-based grain sizes to determine the correlation between mean grain sizes and ultrasonic measurements. Demonstrated the ability of using the correlation curve to deduce grain sizes with measured ultrasonic backscattering coefficients for a few 316L stainless steel specimens whose grain sizes were unknown beforehand but were targeted to be an extrapolation to larger grain sizes than used to formulate the correlation curves. Experimental procedures and computational algorithms are developed and validated for these tasks. This work establishes an ultrasonic technique for characterizing material microstructure with ultrafine grains that are often resulted by solid-phase processing. The technique is nondestructive, and it has the potential to be used for real time inline process monitoring. This work successfully demonstrates the viability of an ultrasonic nondestructive evaluation method for microstructural characterization of material having ultrafine grain structure (as small as 1?mm) and produced by an advanced manufacturing method. This includes a demonstration of the method to extrapolate to other conditions. While not demonstrated here, the method is expected to be viable for in-line, or near-inline, process monitoring in advanced manufacturing applications with suitable consideration for access of instrumentation to the material being manufactured.

316 L Stainless Steel↗

Methods for Measuring and Computing the Reference Temperature in Newton’s Law of Cooling for External Flows

Newton’s law of cooling requires a reference temperature (𝑇 𝑟𝑒𝑓 ) to define the heat-transfer coefficient (ℎ). For external flows with multiple temperatures in the freestream, obtaining 𝑇 𝑟𝑒𝑓 is a challenge. One widely used method, referred to as the adiabatic-wall (AW) method, obtains 𝑇 𝑟𝑒𝑓 by requiring the surface of the solid exposed to convective heat transfer to be adiabatic. Another widely used method, referred to as the linear-extrapolation (LE) method, obtains 𝑇 𝑟𝑒𝑓 by measuring/computing the heat flux ($𝑞^{′′}_𝑠$) on the solid surface at two different surface temperatures (𝑇 𝑠 ) and then linearly extrapolating to $𝑞^{′′}_𝑠$ = 0. A third recently developed method, referred to as the state-space (SS) method, obtains 𝑇 𝑟𝑒𝑓 by probing the temperature space between the highest and lowest in the flow to account for the effects of 𝑇 𝑠 or $𝑞^{′′}_𝑠$ on 𝑇 𝑟𝑒𝑓 . This study examines the foundation and accuracy of these methods via a test problem involving film cooling of a flat plate where $𝑞^{′′}_𝑠$ switches signs on the plate’s surface. Results obtained show that only the SS method could guarantee a unique and physically meaningful 𝑇 𝑟𝑒𝑓 where 𝑇 𝑠 =𝑇 𝑟𝑒𝑓 on a nonadiabatic surface $𝑞^{′′}_𝑠$ = 0. The AW and LE methods both assume 𝑇 𝑟𝑒𝑓 to be independent of 𝑇 𝑠 , which the SS method shows to be incorrect. Though this study also showed the adiabatic-wall temperature, 𝑇 𝐴𝑊 , to be a good approximation of 𝑇 𝑟𝑒𝑓 (<10% relative error), huge errors can occur in ℎ about the solid surface where |𝑇 𝑠 −𝑇 𝐴𝑊 | is near zero because where 𝑇 𝑠 =𝑇 𝐴𝑊 , $𝑞^{′′}_𝑠$ ≠ 0.

Newton's law of cooling↗

Computer-Vision-Based Vibration Tracking Using a Digital Camera: A Sparse-Optical-Flow-Based Target Tracking Method

Computer-vision-based target tracking is a technology applied to a wide range of research areas, including structural vibration monitoring. However, current target tracking methods suffer from noise in digital image processing. In this paper, a new target tracking method based on the sparse optical flow technique is introduced for improving the accuracy in tracking the target, especially when the target has a large displacement. The proposed method utilizes the Oriented FAST and Rotated BRIEF (ORB) technique which is based on FAST (Features from Accelerated Segment Test), a feature detector, and BRIEF (Binary Robust Independent Elementary Features), a binary descriptor. ORB maintains a variety of keypoints and combines the multi-level strategy with an optical flow algorithm to search the keypoints with a large motion vector for tracking. Then, an outlier removal method based on Hamming distance and interquartile range (IQR) score is introduced to minimize the error. The proposed target tracking method is verified through a lab experiment—a three-story shear building structure subjected to various harmonic excitations. It is compared with existing sparse-optical-flow-based target tracking methods and target tracking methods based on three other types of techniques, i.e., feature matching, dense optical flow, and template matching. The results show that the performance of target tracking is greatly improved through the use of a multi-level strategy and the proposed outlier removal method. The proposed sparse-optical-flow-based target tracking method achieves the best accuracy compared to other existing target tracking methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of eight optimization methods applied to a wind farm layout optimization problem

Abstract. Selecting a wind farm layout optimization method is difficult. Comparisons between optimization methods in different papers can be uncertain due to the difficulty of exactly reproducing the objective function. Comparisons by just a few authors in one paper can be uncertain if the authors do not have experience using each algorithm. In this work we provide an algorithm comparison for a wind farm layout optimization case study between eight optimization methods applied, or directed, by researchers who developed those algorithms or who had other experience using them. We provided the objective function to each researcher to avoid ambiguity about relative performance due to a difference in objective function. While these comparisons are not perfect, we try to treat each algorithm more fairly by having researchers with experience using each algorithm apply each algorithm and by having a common objective function provided for analysis. The case study is from the International Energy Association (IEA) Wind Task 37, based on the Borssele III and IV wind farms with 81 turbines. Of particular interest in this case study is the presence of disconnected boundary regions and concave boundary features. The optimization methods studied represent a wide range of approaches, including gradient-free, gradient-based, and hybrid methods; discrete and continuous problem formulations; single-run and multi-start approaches; and mathematical and heuristic algorithms. We provide descriptions and references (where applicable) for each optimization method, as well as lists of pros and cons, to help readers determine an appropriate method for their use case. All the optimization methods perform similarly, with optimized wake loss values between 15.48 % and 15.70 % as compared to 17.28 % for the unoptimized provided layout. Each of the layouts found were different, but all layouts exhibited similar characteristics. Strong similarities across all the layouts include tightly packing wind turbines along the outer borders, loosely spacing turbines in the internal regions, and allocating similar numbers of turbines to each discrete boundary region. The best layout by annual energy production (AEP) was found using a new sequential allocation method, discrete exploration-based optimization (DEBO). Based on the results in this study, it appears that using an optimization algorithm can significantly improve wind farm performance, but there are many optimization methods that can perform well on the wind farm layout optimization problem, given that they are applied correctly.

17 WIND ENERGY↗

Efficient algorithm for generating spectra using line-by-lne methods

A method is presented for efficient generation of spectra using line-by-line approaches. The only approximation is replacing the line shape function with an interpolation procedure, which makes the method independent of the line profile functional form. The resulting computational savings for large number of lines is proportional to the number of frequency points in the spectral range. Therefore, for large-scale problems the method can provide speedups of two orders of magnitude or more. A method was presented to generate line-by-line spectra efficiently. The first step was to replace the explicit calculation of the profile by the Newton divided-differences interpolating polynomial. The second step is to accumulate the lines effectively reducing their number to the number of frequency points. The final step is recognizing the resulting expression as a convolution and amenable to FFT methods. The reduction in computational effort for a configuration-to-configuration transition array with large number of lines is proportional to the number of frequency points. The method involves no approximations except for replacing the explicit profile evaluation by interpolation. Specifically, the line accumulation and convolution are exact given the interpolation procedure. Furthermore, the interpolation makes the method independent of the line profile functional form contrary to other schemes using FFT methods to generate line-by-line spectra but relying on the analytic form of the profile Fourier transform. Finally, the method relies on a uniform frequency mesh. For non-uniform frequency meshes, however, the method can be applied by using a suitable temporary uniform mesh and the results interpolated onto the final mesh with little additional cost.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Comparative Study of Different Reconstruction Schemes for a Reconstructed Discontinuous Galerkin Method on Arbitrary Grids

A comparative study of different reconstruction schemes for a reconstruction-based discontinuous Galerkin, termed RDG(P1P2) method is performed for compressible flow problems on arbitrary grids. The RDG method is designed to enhance the accuracy of the discontinuous Galerkin method by increasing the order of the underlying polynomial solution via a reconstruction scheme commonly used in the finite volume method. Both Green-Gauss and least-squares reconstruction methods and a least-squares recovery method are implemented to obtain a quadratic polynomial representation of the underlying discontinuous Galerkin linear polynomial solution on each cell. These three reconstruction/recovery methods are compared for a variety of compressible flow problems on arbitrary meshes to access their accuracy and robustness. The numerical results demonstrate that all three reconstruction methods can significantly improve the accuracy of the underlying second-order DG method, although the least-squares reconstruction method provides the best performance in terms of both accuracy and robustness.

97 MATHEMATICS AND COMPUTING↗