Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

A hybrid six-dimensional muon cooling channel using gas filled rf cavities

We describe an alternative cooling approach to prevent rf breakdown in magnetic fields that simultaneously reduces all six phase-space dimensions of a muon beam. In this process, cooling is accomplished by reducing the beam momentum through ionization energy loss in discrete absorbers and replenishing the momentum loss only in the longitudinal direction through gas-filled rf cavities. The advantage of gas filled cavities is that they can run at high gradients in magnetic fields without breakdown. Using this approach, we show that our channel can achieve a decrease of the 6-dimensional phase-space volume by several orders of magnitude. With the aid of numerical simulations, we demonstrate that the transmission of our proposed channel is comparable to that of an equivalent channel with vacuum rf cavities. Finally, we discuss the sensitivity of the channel performance to the choice of gas and operating pressure.

43 PARTICLE ACCELERATORS↗

A discrete-continuum coupled finite element modelling approach for fibre reinforced concrete

Highlights: • An easy-to-implement but effective meso-scale modelling approach is developed for FRC. • It is capable of simulating and interpreting all main failure mechanisms in FRC. • It is critically validated by experiments with single or multiple random fibres under various loading conditions. • It can be used to optimise key design factors of FRC at meso/material scale by parametric studies. - Abstract: Fibre reinforced concrete (FRC) exhibits complicated failure modes such as fibre breakage, mortar cracking, crushing and spalling, fibre-mortar interfacial debonding, depending on many material properties, geometric dimensions, boundary and loading conditions. Most existing numerical models are unable to reproduce these failure modes that may occur simultaneously or sequentially in a specimen, mainly due to difficulties in generating finite element meshes with a large number of randomly-oriented fibres. Herein we develop a discrete-continuum coupled finite element modelling approach for FRC materials capable of effectively simulating all the major failure modes. The continuum damaged plasticity model is used to simulate damage and fracture behaviour of the mortar, while debonding of fibre-mortar interfaces is modelled by nonlinear cohesive interfacial elements. Unique techniques are devised to generate conforming meshes between fibres and the surrounding mortar so that the randomly-oriented fibres are easily modelled. The modelling approach is validated by simulating single fibre pullout tests with different inclination angles, notched and non-notched direct tensile tests and three-point bending beam tests with randomly-distributed multiple fibres.

36 MATERIALS SCIENCE↗

New detection system and signal processing for the tokamak ISTTOK heavy ion beam diagnostic

The tokamak ISTTOK heavy ion beam diagnostic (HIBD) operates with a multiple cell array detector (MCAD) that allows for the plasma density and the plasma density fluctuations measurements simultaneously at different sampling volumes across the plasma. To improve the capability of the plasma density fluctuations investigations, a new detection system and new signal conditioning amplifier have been designed and tested. The improvements in MCAD design are presented which allow for nearly complete suppression of the spurious plasma background signal by applying a biasing potential onto special electrodes incorporated into MCAD. The new low cost and small size transimpedance amplifiers are described with the parameters of 400 kHz, 10{sup 7} V/A, 0.4 nA of RMS noise, adequate for the plasma density fluctuations measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the AFP project in the ATLAS experiment

Status of the AFP project in the ATLAS experiment is summarized. The AFP system is composed of a tracker to detect intact, diffractively scattered protons, and of a time-of-flight detector serving to suppress background from pile-up interactions. The whole system, located around 210 m from the main ATLAS detector, is placed in Roman Pots which move detectors from and to the incident proton beams. A typical distance of the closest approach of the tracker to these beams is 2–3 mm. The main physics motivation lies in measuring diffractive processes in runs with not a very high amount of pile-up.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scattering effect on the imaging depth limit in two-photon fluorescence microscopy

A model for the propagation of a focused light beam in a strongly scattering medium is used to analyse various factors that limit the capability of two-photon fluorescence microscopy (TPFM) to image deep sections of optically thick biological specimens. The TPFM imaging depth is shown to be limited by three main factors: (1) beam broadening as a result of multiple small-angle scattering, leading to a loss of submicron lateral resolution; (2) strong near-surface fluorescence at large imaging depths as a result of the increase in average source power in order to compensate for scattering losses; (3) reduction in useful two-photon fluorescence signal level because of the exponential attenuation of the excitation power. The influence of these factors is examined in a small-angle diffusion approximation of radiative transfer theory. The first two of them are shown to set a fundamental TPFM limit, whereas the last is an instrumental limitation and appears to be the most critical to state-of-the-art commercial two-photon laser scanning microscopy systems for the vast majority of fluorophores in current use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Head erosion with emittance growth in PWFA

Head erosion is one of the limiting factors in plasma wakefield acceleration (PWFA). We present a study of head erosion with emittance growth in field-ionized plasma from the PWFA experiments performed at the FACET user facility at SLAC. At FACET, a 20.3 GeV bunch with 1.8 Multiplication-Sign 10{sup 10} electrons is optimized in beam transverse size and combined with a high density lithium plasma for beam-driven plasma wakefield acceleration experiments. A target foil is inserted upstream of the plasma source to increase the bunch emittance through multiple scattering. Its effect on beamplasma interaction is observed with an energy spectrometer after a vertical bend magnet. Results from the first experiments show that increasing the emittance has suppressed vapor field-ionization and plasma wakefields excitation. Plans for the future are presented.

43 PARTICLE ACCELERATORS↗

Ion Engine Plume Interaction Calculations for Prototypical Prometheus 1

Prometheus 1 is a conceptual mission to demonstrate the use of atomic energy for distant space missions. The hypothetical spacecraft design considered in this paper calls for multiple ion thrusters, each with considerably higher beam energy and beam current than have previously flown in space. The engineering challenges posed by such powerful thrusters relate not only to the thrusters themselves, but also to designing the spacecraft to avoid potentially deleterious effects of the thruster plumes. Accommodation of these thrusters requires good prediction of the highest angle portions of the main beam, as well as knowledge of clastically scattered and charge exchange ions, predictions for grid erosion and contamination of surfaces by eroded grid material, and effects of the plasma plume on radio transmissions. Nonlinear interactions of multiple thrusters are also of concern. In this paper we describe two- and three-dimensional calculations for plume structure and effects of conceptual Prometheus 1 ion engines. Many of the techniques used have been validated by application to ground test data for the NSTAR and NEXT ion engines. Predictions for plume structure and possible sputtering and contamination effects will be presented.

Mandell, Myron J.↗

Spherical shock-ignition experiments with the 40 + 20-beam configuration on OMEGA

Spherical shock-ignition experiments on OMEGA used a novel beam configuration that separates low-intensity compression beams and high-intensity spike beams. Significant improvements in the performance of plastic-shell, D 2 implosions were observed with repointed beams. The analysis of the coupling of the high-intensity spike beam energy into the imploding capsule indicates that absorbed hot-electron energy contributes to the coupling. The backscattering of laser energy was measured to reach up to 36% at single-beam intensities of ~ 8 x 10 15 W/cm/ 2 . Hard x-ray measurements revealed a relatively low hot-electron temperature of ~30 keV independent of intensity and timing. At the highest intensity, stimulated Brillouin scattering occurs near and above the quarter-critical density and the two-plasmon-decay instability is suppressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of multiplicity fluctuations of identified hadrons in inelastic proton–proton interactions at the CERN Super Proton Synchrotron

Measurements of multiplicity fluctuations of identified hadrons produced in inelastic p+p interactions at 31, 40, 80, and 158 $\text {Ge}\text {V}/c$ beam momentum are presented. Three different measures of multiplicity fluctuations are used: the scaled variance $\omega $ and strongly intensive measures $\Sigma $ and $\Delta $. These fluctuation measures involve second and first moments of joint multiplicity distributions. Data analysis is preformed using the Identity method which corrects for incomplete particle identification. Strongly intensive quantities are calculated in order to allow for a direct comparison to corresponding results on nucleus–nucleus collisions. The results for different hadron types are shown as a function of collision energy. A comparison with predictions of string-resonance Monte-Carlo models: Epos, Smash and Venus, is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-450: Dosimetric Impact of Rotational Error On Multiple-Target Intensity-Modulated Radiosurgery (IMRS) with Single-Isocenter

Purpose: Evaluating the dosimetric-impact on multiple-targets placed away from the isocenter-target with varying rotational-error introduced by initial setup uncertainty and/or intrafractional-movement Methods: CyberKnife-Phantom was scanned with the Intracranial SRS-protocol of 1.25mm slice-thickness and the multiple-targets(GTV) of 1mm and 10mm in diameter were contoured on the Eclipse. PTV for distal-target only was drawn with 1mm expansion around the GTV to find out how much margin is needed to compensate for the rotational-error. The separation between the isocenter-target and distal-target was varied from 3cm to 7cm. RapidArc-based IMRS plans of 16Gy single-fraction were generated with five non-coplanar arcs by using Varian TrueBeam-STx equipped with high resolution MLC leaves of 2.5mm at center and with dose-rate of 1400MU/min at 6MV for flatteringfilter- free(FFF). An identical CT image with intentionally introduced 1° rotational-error was registered with the planning CT image, and the isodose distribution and Dose-Volume-Histogram(DVH) were compared with the original plans. Additionally, the dosimetric-impact of rotational error was evaluated with that of 6X photon energy which was generated with the same target-coverage. Results: For the 1mm-target with 6X-FFF, PTV-coverage(D100) of the distal-target with 1° rotational-error decreased from 1.00 to 0.35 as the separation between isocenter-target and distal-target increased from 3cm to 7cm. However, GTV-coverage(D100) was 1.0 except that of 7cm-separation(0.55), which resulted from the 1mm-margin around the distal-target. For 6X photon, GTV-coverage remained at 1.0 regardless of the separation of targets, showing that the dosimetric-impact of rotational error depends on the degree of rotational-error, separation of targets, and dose distribution around targets. For 10mm-target, PTV-coverage of distaltarget located 3cm-away was better than that of 1mm-target(0.93 versus 0.7) and GTV-coverage was 1.0 regardless of 6X-FFF/6X photon beams. Conclusion: RapidArc-based Multiple-target IMRS may Resultin a compromised outcome due to the setup-error for distal-targets. With 1mm-margin, GTV-coverage of distal-target was 1.0 although the separation of targets was up to 5cm.

07 ISOTOPE AND RADIATION SOURCES↗

"DIAGNOSTIC" PULSE FOR SINGLE-PARTICLE-LIKE BEAM POSITION MEASUREMENTS DURING ACCUMULATION/PRODUCTION MODE IN THE LOS ALAMOS PROTON STORAGE RING

Beam position monitors (BPMs) are the primary diagnostic in the Los Alamos Proton Storage Ring (PSR). When injecting one turn, the transversemotion is approximated as a single particle with initial betatron position and angle {rvec x}{sub 0} and {rvec x}'{sub 0}. With single-turn injection, we fit the betatron tune, closed orbit (CO), and injection offset ({rvec x}{sub 0} and {rvec x}'{sub 0} at the injection point) to the turn-by-turn beam position. In production mode, we accumulate multiple turns, the transverse phase space fills after 5 injections (horizontal and vertical fractional betatron tunes {approx}0.2) resulting in no coherent betatron motion, and only the CO may be measured. The injection offset, which determines the accumulated beam size and is very sensitive to steering upstream of the ring, is not measurable in production mode. We describe our approach and ongoing efforts to measure the injection offset during production mode by injecting a 'diagnostic' pulse {approx}50 {micro}s after the accumulated beam is extracted. We also study the effects of increasing the linac RF gate length to accommodate the diagnostic pulse on the production beam position, transverse size, and loss.

43 PARTICLE ACCELERATORS↗

Method of making an ion beam sputter-etched ventricular catheter for hydrocephalus shunt

The centricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large opening at its inlet end and a multiplicity of microscopic openings along its lateral surfaces. The microtubules are perforated by an ion beam sputter etch technique. The holes are etched in each microtubule by directing an ion beam through an electro formed mesh mask producing perforations having diameters ranging from about 14 microns to about 150 microns. This structure assures a reliable means for shunting cerebrospinal fluid from the cerebral ventricles to selected areas of the body.

Banks, B. A.↗

Nonperturbative methods in HZE propagation

An analytical solution to the perturbative multiple collision series of a fragmenting HZE ion beam has limited usefulness since the first collision term has several hundred contributions, the second collision term has tens of thousands of contributions, and each successive collision term progresses to unwieldy computational proportions. Our previous work has revealed the multiple collision terms in the straight-ahead approximation to be simple products of a spatially dependent factor times a linear energy-dependent factor of limited domain and unit normalization. The properties of these forms allow the development of the nonperturbative summation of the series to all orders assuming energy-independent nuclear cross sections as matrix products of a scaled Green's function described herein. This nonperturbative Green's function with multiple scattering correction factors compares well with experiments using 670 MeV/u neon-20 ion beams in thick water targets.

Non-NASA Center↗

Poster - 20: Detector selection for commissioning of a Monte Carlo based electron dose calculation algorithm

Objective: Commissioning of a Monte Carlo based electron dose calculation algorithm requires percentage depth doses (PDDs) and beam profiles which can be measured with multiple detectors. Electron dosimetry is commonly performed with cylindrical chambers but parallel plate chambers and diodes can also be used. The purpose of this study was to determine the most appropriate detector to perform the commissioning measurements. Methods: PDDs and beam profiles were measured for beams with energies ranging from 6 MeV to 15 MeV and field sizes ranging from 6 cm × 6 cm to 40 cm × 40 cm. Detectors used included diodes, cylindrical and parallel plate ionization chambers. Beam profiles were measured in water (100 cm source to surface distance) and in air (95 cm source to detector distance). Results: PDDs for the cylindrical chambers were shallower (1.3 mm averaged over all energies and field sizes) than those measured with the parallel plate chambers and diodes. Surface doses measured with the diode and cylindrical chamber were on average larger by 1.6 % and 3% respectively than those of the parallel plate chamber. Profiles measured with a diode resulted in penumbra values smaller than those measured with the cylindrical chamber by 2 mm. Conclusion: The diode was selected as the most appropriate detector since PDDs agreed with those measured with parallel plate chambers (typically recommended for low energies) and results in sharper profiles. Unlike ion chambers, no corrections are needed to measure PDDs, making it more convenient to use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Competing Pathways for Nucleation of the Double Perovskite Structure in the Epitaxial Synthesis of La 2 MnNiO 6

Over the past decades a confluence of advanced synthesis techniques, data-driven characterization, and rapid increases in computing power has sparked a renaissance in materials engineering. The emerging “materials-by-design” approach, while radically transforming the development of multicomponent systems, has tended to overlook the complex kinetic pathways that define materials synthesis. Although we are able to envision almost limitless materials combinations, we are unable to synthesize all of them in practice, since existing characterization and modeling approaches often fail to capture the inherent complexity of such systems. There is currently a disconnect between highly local structural characterization and macroscale properties measurements, resulting in oversimplified or incomplete structure-property models. Here we describe a multi-technique approach that combines aberration-corrected transmission electron microscopy with emerging oxide atom probe tomography to measure chemical ordering and extended defects in the model complex oxide, La2MnNiO6. We visualize cation ordering, as well as a three-dimensional network of secondary phases, which we describe in terms of ab initio structure calculations. We propose a defect model in which these phases alter their surrounding octahedral environment, severely disrupting cation superexchange. Through this array of experimental and theoretical techniques, we uncover fundamental structure-property relationships and illustrate a new approach to engineer complex, multicomponent systems.

atom probe tomography↗

Temperature stability of intersubband transitions in AlN/GaN quantum wells

Temperature dependence of intersubband transitions in AlN/GaN multiple quantum wells grown with molecular beam epitaxy is investigated both by absorption studies at different temperatures and modeling of conduction-band electrons. For the absorption study, the sample is heated in increments up to 400 deg. C. The self-consistent Schroedinger-Poisson modeling includes temperature effects of the band gap and the influence of thermal expansion on the piezoelectric field. We find that the intersubband absorption energy decreases only by approx6 meV at 400 deg. C relative to its room temperature value.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High energy physics - The large and the small

In this Sixth International School on Field Theory and Gravitation, I was invited to give this talk to the students and researchers of Field Theory mainly about LHC - The Large Hadron Collider and results. I will try to summarize the main daily life of the high energy physics and give an idea about the experiments and the expectations for the near future. I will comment the present results and the prospects to LHC/CMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalizing the flash technique in the front-face configuration to measure the thermal diffusivity of semitransparent solids

In this work, we have extended the front-face flash method to retrieve simultaneously the thermal diffusivity and the optical absorption coefficient of semitransparent plates. A complete theoretical model that allows calculating the front surface temperature rise of the sample has been developed. It takes into consideration additional effects, such as multiple reflections of the heating light beam inside the sample, heat losses by convection and radiation, transparency of the sample to infrared wavelengths, and heating pulse duration. Measurements performed on calibrated solids, covering a wide range of absorption coefficients (from transparent to opaque) and thermal diffusivities, validate the proposed method.

42 ENGINEERING↗