Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter continuation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gyrokinetic electromagnetic particle simulations in triangular meshes with C1 finite elements

The triangular mesh-based gyrokinetic scheme enables comprehensive axis-to-edge studies across the entire plasma volume. Our approach employs triangular finite elements with first-derivative continuity (C1), building on previous work to facilitate gyrokinetic simulations. Additionally, we have adopted the mixed variable/pullback scheme for gyrokinetic electromagnetic particle simulations. The filter-free treatment in the poloidal cross-section with triangular meshes introduces unique features and challenges compared to previous treatments using structured meshes. Our implementation has been validated through benchmarks using ITPA-toroidicity-induced Alfvén eigenmode parameters, showing its capability in moderate to small electron skin depth regimes. Additional examinations using experimental parameters confirm its applicability to realistic plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy

Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image-guided brachytherapy. Before introducing a new device into clinical operations, it is important to assess the reliability and mean time before failure (MTBF) of the system. In this article, the authors present the preclinical evaluation and analysis of the reliability and MTBF of an autonomous robotic system, which is developed for prostate seed implantation. Methods: The authors have considered three steps that are important in reliability growth analysis. These steps are: Identification and isolation of failures, classification of failures, and trend analysis. For any one-of-a-kind product, the reliability enhancement is accomplished through test-fix-test. The authors have used failure mode and effect analysis for collection and analysis of reliability data by identifying and categorizing the failure modes. Failures were classified according to severity. Failures that occurred during the operation of this robotic system were considered as nonhomogenous Poisson process. The failure occurrence trend was analyzed using Laplace test. For analyzing and predicting reliability growth, commonly used and widely accepted models, Duane's model and the Army Material Systems Analysis Activity, i.e., Crow's model, were applied. The MTBF was used as an important measure for assessing the system's reliability. Results: During preclinical testing, 3196 seeds (in 53 test cases) were deposited autonomously by the robot and 14 critical failures were encountered. The majority of the failures occurred during the first few cases. The distribution of failures followed Duane's postulation as well as Crow's postulation of reliability growth. The Laplace test index was -3.82 (<0), indicating a significant trend in failure data, and the failure intervals lengthened gradually. The continuous increase in the failure occurrence interval suggested a trend toward improved reliability. The MTBF was 592 seeds, which implied that several prostate seed implantation cases would be possible without encountering any critical failure. The shape parameter for the MTBF was 0.3859 (<1), suggesting a positive reliability growth of this robotic system. At 95% confidence, the reliability for deposition of 65 seeds was more than 90%. Conclusions: Analyses of failure mode strongly indicated a gradual improvement of reliability of this autonomous robotic system. High MTBF implied that several prostate seed implant cases would be possible without encountering any critical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coolant Density and Control Blade History Effects in Extended BWR Burnup Credit

Oak Ridge National Laboratory and the US Nuclear Regulatory Commission have initiated a multiyear project to investigate the application of burnup credit (BUC) for boiling water reactor (BWR) fuel in storage and transportation casks. This project includes two phases. The first phase investigates the applicability of peak reactivity methods currently used for spent fuel pools to spent fuel storage and transportation casks and the validation of reactivity (k eff ) calculations and predicted spent fuel compositions. The second phase focuses on extending BUC beyond peak reactivity. This paper documents work performed to date investigating some aspects of extended BUC. (The technical basis for application of peak reactivity methods to BWR fuel in storage and transportation systems is presented in a companion paper.) Two reactor operating parameters are being evaluated to establish an adequate basis for extended BWR BUC: (1) the effect of axial void profile and (2) the effect of control blade utilization during operation. A detailed analysis of core simulator data for one cycle of a modern operating BWR plant was performed to determine the range of void profiles and the variability of the profile experienced during irradiation. Although a single cycle does not provide complete data, the data obtained are sufficient to determine the primary effects and to identify conservative modeling approaches. These data were used in a study of the effect of axial void profile. The first stage of the study was determination of the necessary moderator density temporal fidelity in depletion modeling. After the required temporal fidelity was established, multiple void profiles were used to examine the effect on cask reactivity. The results of these studies are being used to develop recommendations for conservatively modeling the void profile effects for BWR depletion calculations. The second operational parameter studied was control blade history. Control blades are inserted in various locations and at varying degrees during BWR operation based on the core loading pattern. When present during depletion, control blades harden the neutron spectrum locally because they displace the moderator and absorb thermal neutrons. The investigation of the effect of control blades on post operational cask reactivity is documented herein, as is the effect of multiple (continuous and intermittent) exposure periods with control blades inserted. The coupled effects of control blade presence on power density, void profile, or burnup profile will be addressed in future work.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coolant density and control blade history effects in extended BWR burnup credit - 14494

Oak Ridge National Laboratory and the US Nuclear Regulatory Commission have initiated a multiyear project to investigate the application of burnup credit (BUC) for boiling water reactor (BWR) fuel in storage and transportation casks. This project includes two phases. The first phase investigates the applicability of peak reactivity methods currently used for spent fuel pools to spent fuel storage and transportation casks and the validation of reactivity (k{sub eff}) calculations and predicted spent fuel compositions. The second phase focuses on extending BUC beyond peak reactivity. This paper documents work performed to date investigating some aspects of extended BUC. The technical basis for application of peak reactivity methods to BWR fuel in storage and transportation systems is presented in a companion paper. Two reactor operating parameters are being evaluated to establish an adequate basis for extended BWR BUC: (1) the effect of axial void profile and (2) the effect of control blade utilization during operation. A detailed analysis of core simulator data for one cycle of a modern operating BWR plant was performed to determine the range of void profiles and the variability of the profile experienced during irradiation. Although a single cycle does not provide complete data, the data obtained are sufficient to determine the primary effects and to identify conservative modeling approaches. These data were used in a study of the effect of axial void profile. The first stage of the study was determination of the necessary moderator density temporal fidelity in depletion modeling. After the required temporal fidelity was established, multiple void profiles were used to examine the effect on cask reactivity. The results of these studies are being used to develop recommendations for conservatively modeling the void profile effects for BWR depletion calculations. The second operational parameter studied was control blade history. Control blades are inserted in various locations and at varying degrees during BWR operation based on the core loading pattern. When present during depletion, control blades harden the neutron spectrum locally because they displace the moderator and absorb thermal neutrons. The investigation of the effect of control blades on post operational cask reactivity is documented herein, as is the effect of multiple (continuous and intermittent) exposure periods with control blades inserted. The coupled effects of control blade presence on power density, void profile, or burnup profile will be addressed in future work. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of the Sunset Semi-Continuous Carbon Aerosol Analyzer

Accurate quantification of carbonaceous aerosols is essential for reducing uncertainty in climate change models and is important for long-term air quality monitoring by government agencies. The field-deployable Sunset Semi-Continuous Organic Carbon/Elemental Carbon Aerosol Analyzer (Sunset OCEC) utilizes a modified National Institute for Occupational Safety and Health thermal-optical method to determine total carbon (TC), organic carbon (OC), and elemental carbon (EC) at near real-time; however, its performance is not yet fully characterized. Two collocated Sunset OCEC Analyzers, Unit A and Unit B, were used to determine the relative standard deviation (RSD) and limit of detection (LOD) between June 23 and July 9, 2007, in Richland, Washington, USA. A high-efficiency particulate air filter was utilized to determine the LODs of both instruments. The RSDs between the two Sunset OCECs were 9.12% for TC, 13.0% for Optical OC, and 8.97% for Thermal OC, indicating good precision between the instruments, although the RSDs for Thermal and Optical EC were higher, 29.0% and 48.3%, respectively. The LOD of Unit A was approximately 0.21 µgC/m3 for TC, Optical OC, and Thermal OC, and ~0.004 µgC/m3 for Optical and Thermal EC. Similarly, Unit B had an LOD of ~0.29 µgC/m3 for TC, Optical OC, and Thermal OC, 0.018 µgC/m3 for Optical EC, and 0.004 µgC/m3 for Thermal EC. Factors that may have contributed to the poor RSDs of Thermal and Optical EC include the low EC mass loading in Richland, minor leakage in the oxygen valve of Unit B, and excessive noise from the non-dispersive infrared (NDIR) laser in Unit B, resulting in scattered Optical EC measurements. Improved RSDs of all OC and EC parameters are expected after the Unit B NDIR is tuned up. Future work should reevaluate the precision of the Sunset OCECs and investigate the differences in various thermal-optical protocols on OCEC quantification.

54 ENVIRONMENTAL SCIENCES↗

Estimation of sensor measurement errors in reactor coolant systems using multi-sensor fusion

A nuclear power plant is typically instrumented with a variety of sensors to continually monitor its variables, and their sensor’s measurements may be used to assess the plant state and initiate safety actions, if needed. Errors in sensor measurements, due to factors such as calibration drifts, critically affect such state assessments. Here, we address a problem of estimating sensor errors using physics-informed machine learning methods that use measurements collected under known plant conditions. For a given sensor, we propose an information fusion method that uses measurements from other sensors to estimate its output assuming it is error-free and provides its difference from an actual measurement as an error estimate. We present the ensemble of trees and support vector machine fusers, and evaluate their performance using measurements collected over an emulated test loop of a pressurized water reactor. The plant variables are related to each other through the underlying physical laws under inertial constraints that place bounds on their derivatives, which analytically justify the applicability of machine learning methods for computing these fusers. Under twenty scenarios, we assess their sensor error estimates for pressure sensors of the heat exchanger of a reactor’s primary coolant system. Multiple types of errors are captured by both fusers under externally induced calibration drifts, blockages, minor leaks and air gaps in sensing lines, and electromagnetic interference; the root mean square error of the estimation of error is under 2.2% percent of the maximum measurement. We present generalization equations, in the framework of statistical learning theory, for these methods that characterize the confidence probability that the estimation error is bounded by a specified parameter in future test scenarios.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Deep Learning for Fish Identification from Sonar Data: CRADA 481 [Abstract only]

To help solve the challenges of hydropower energy production related to the potential for eel injury and mortality from passage through hydropower turbines, we will develop a deep learning method for identifying migrating eels from imaging sonar. This project continues with a prior project conducted by the Pacific Northwest National Laboratory (PNNL) and the Electric Power Research Institute (EPRI) in FY2018-2019. The proposed method employs Convolution Neural Network (CNN), a powerful deep learning method for image classification, to distinguish between images of eels and non-eel moving objects. We propose to collect more laboratory data and add more existing field data to train a powerful deep learning model. In addition to eels and sticks as classified in previous studies, we will add images containing several non-eel fish species and macrophyte mats to the training data. A multi-class classification model will be developed to distinguish these objects. Object detection algorithm will be explored and developed to locate and identify multiple objects in each sonar frame. Motion analysis will be performed to track the movement of objects in sonar video clips. We will also improve the data conversion algorithm so that it can read in both DIDSON and ARIS (both are imaging sonars developed by Sound Metrics Corp) data files and convert them to images with comparably high resolution, regardless of the varying detection ranges in different environments. The developed algorithms will be packaged as a software with a graphic user interface. The software will be evaluated by external collaborators in the field. The developed framework can be generalized for automatic monitoring of fish passage and migration using other imaging sonars like ARIS and will benefit the design and operation of ecologically friendly hydroelectric projects. The developed wavelet and CNN model configuration parameters can potentially be transferred to lamprey detection in similar riverine environments.

13 HYDRO ENERGY↗

Biodiesel Impact on Engine Lubricant Dilution During Active Regeneration of Aftertreatment Systems

Experiments were conducted with ultra low sulfur diesel (ULSD) and 20% biodiesel blends (B20) to compare lube oil dilution levels and lubricant properties for systems using late in-cylinder fuel injection for aftertreatment regeneration. Lube oil dilution was measured by gas chromatography (GC) following ASTM method D3524 to measure diesel content, by Fourier transform infrared (FTIR) spectrometry following a modified ASTM method D7371 to measure biodiesel content, and by a newly developed back-flush GC method that simultaneously measures both diesel and biodiesel. Heavy-duty (HD) engine testing was conducted on a 2008 6.7L Cummins ISB equipped with a diesel oxidation catalyst (DOC) and diesel particle filter (DPF). Stage one of engine testing consisted of 10 consecutive repeats of a forced DPF regeneration event. This continuous operation with late in-cylinder fuel injection served as a method to accelerate lube-oil dilution. Stage two consisted of 16 hours of normal engine operation over a transient test cycle, which created an opportunity for any accumulated fuel in the oil sump to evaporate. Light duty (LD) vehicle testing was conducted on a 2010 VW Jetta equipped with DOC, DPF and a NOx storage catalyst (NSC). Vehicle testing comprised approximately 4,000 miles of operation on a mileage-accumulation dynamometer (MAD) using the U.S. Environmental Protection Agency's Highway Fuel Economy Cycle because of the relatively low engine oil and exhaust temperatures, and high DPF regeneration frequency of this cycle relative to other cycles examined. Comparison of the lube oil dilution analysis methods suggests that D3524 does not measure dilution by biodiesel. The new back-flush GC method provided analysis for both diesel and biodiesel, in a shorter time and with lower detection limit. Thus all lube oil dilution results in this paper are based on this method. Analysis of the HD lube-oil samples showed only 1.5% to 1.6% fuel dilution for both fuels during continuous operation under DPF regeneration events. During the second stage of HD testing, the ULSD lube-oil dilution levels fell from 1.5% to 0.8%, while for B20, lube-oil dilution levels fell from 1.6% to 1.0%, but the fuel in the oil was 36% biodiesel. For the LD vehicle tests, the frequency of DPF regeneration events was observed to be the same for both ULSD and B20. No significant difference between the two fuels' estimated soot loading was detected by the engine control unit (ECU), although a 23% slower rate of increase in differential pressure across DPF was observed with B20. It appears that the ECU estimated soot loading is based on the engine map, not taking advantage of the lower engine-out particulate matter from the use of biodiesel. After 4,000 miles of LD vehicle operation with ULSD, fuel dilution in the lube-oil samples showed total dilution levels of 4.1% diesel. After 4,000 miles of operation with B20, total fuel in oil dilution levels were 6.7% consisting of 3.6% diesel fuel and 3.1% biodiesel. Extrapolation to the 10,000-mile oil drain interval with B20 suggests that the total fuel content in the oil could reach 12%, compared to 5% for operation on ULSD. Analysis of the oil samples also included measurement of total acid number, total base number, viscosity, soot, metals and wear scar; however, little difference in these parameters was noted.

09 BIOMASS FUELS↗

The Effect of Dose-Volume Parameters and Interfraction Interval on Cosmetic Outcome and Toxicity After 3-Dimensional Conformal Accelerated Partial Breast Irradiation

Purpose: To evaluate dose-volume parameters and the interfraction interval (IFI) as they relate to cosmetic outcome and normal tissue effects of 3-dimensional conformal radiation therapy (3D-CRT) for accelerated partial breast irradiation (APBI). Methods and Materials: Eighty patients were treated by the use of 3D-CRT to deliver APBI at our institutions from 2003-2010 in strict accordance with the specified dose-volume constraints outlined in the National Surgical Adjuvant Breast and Bowel Project B39/Radiation Therapy Oncology Group 0413 (NSABP-B39/RTOG 0413) protocol. The prescribed dose was 38.5 Gy in 10 fractions delivered twice daily. Patients underwent follow-up with assessment for recurrence, late toxicity, and overall cosmetic outcome. Tests for association between toxicity endpoints and dosimetric parameters were performed with the chi-square test. Univariate logistic regression was used to evaluate the association of interfraction interval (IFI) with these outcomes. Results: At a median follow-up time of 32 months, grade 2-4 and grade 3-4 subcutaneous fibrosis occurred in 31% and 7.5% of patients, respectively. Subcutaneous fibrosis improved in 5 patients (6%) with extended follow-up. Fat necrosis developed in 11% of women, and cosmetic outcome was fair/poor in 19%. The relative volume of breast tissue receiving 5%, 20%, 50%, 80%, and 100% (V5-V100) of the prescribed dose was associated with risk of subcutaneous fibrosis, and the volume receiving 50%, 80%, and 100% (V50-V100) was associated with fair/poor cosmesis. The mean IFI was 6.9 hours, and the minimum IFI was 6.2 hours. The mean and minimum IFI values were not significantly associated with late toxicity. Conclusions: The incidence of moderate to severe late toxicity, particularly subcutaneous fibrosis and fat necrosis and resulting fair/poor cosmesis, remains high with continued follow-up. These toxicity endpoints are associated with several dose-volume parameters. Minimum and mean IFI values were not associated with late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy Saving Glass Lamination via Selective Radio Frequency Heating

This project focused on advancing radio-frequency (RF) lamination technology closer to commercial implementation, in order to reduce the energy intensity of glass lamination by up to 90%. Lamination comprises a wide range of products including autoglass, architectural safety and innovative design glass, transparent armor (e.g. bullet proof glass), smart glass, mirrors, and encapsulation of photovoltaics. Lamination is also the fastest growing segment of glass manufacturing, with photovoltaics, architectural needs, and an anticipated transition to laminated side windows in vehicles. The state-of-the-art for glass lamination is to use autoclaves, which apply heat and uniform gas pressure to bond the laminates over the course of 1 to 18 hours. Laminates consist of layers of glass or other materials bonded with vinyl or urethane interlayers. In autoclaving, significant heat energy is lost heating the chamber, pressurized air, glass racks, and the glass. In RF lamination, the heat is generated directly in the vinyl interlayer, causing it to heat and melt quickly, in just 1 to 10 minutes, without significantly heating the glass or the equipment. The main purpose of this project was to provide evidence that low energy, rapid RF lamination quality met the same standards as conventionally autoclaved windows. The development of concepts for laminating curved glass with RF lamination was a major goal. Other primary goals included developing a stronger understanding of the lamination product markets described above, and to refine the potential benefits of commercial implementation. The scope of the project was to complete implementation concept studies in preparation for continuation into advanced development, pilot studies, and commercial implementation. The project consisted of 6 main tasks. The first dealt with lamination with poly-vinyl butyral (PVB) interlayers, which prior work had shown difficulties in achieving good quality laminates, working with Pilkington North America. The second task dealt with a study of current lamination processes in the various laminate industries, and development of concepts for integrating RF lamination into new or existing processes. The third task explored the use of a non-destructive technique for analyzing laminate adhesion with the University of Illinois at Urbana-Champaign. The fourth task focused on developing concepts for curved glass lamination using RF lamination. The fifth and sixth tasks together comprised an analysis of laminate product markets, ranking for applicability and commercialization potential, and the development of commercialization strategies for those products. In addition, throughout the project as new experimental data and conventional process data were obtained, the benefits analysis of RF lamination was refined. The goals of the project described above were achieved, positioning RF lamination for the next stage growth envisioned in the original Industrial Grand Challenge proposal. Working with Pilkington North America, lamination of flat autoglass with PVB was achieved, meeting all 16 stringent industry tests. In particular, PVB laminates made with RF lamination passed environmental tests including the high temperature, 120 C bake test, without significant formation of bubbles (defects). The adhesion of PVB to glass was measured using the pummel method. Adhesion values ranging from 1 to 7 out of 10 were obtained. The significant process parameters affecting the environmental and adhesion performance were identified through a designed experiment. Pre-lamination process variables including PVB storage humidity and the de-airing process (vacuum or nip rolling) were significant, as well as the level of pressure applied to the laminate during the RF process. Analysis of manufacturing with RF lamination equipment, based on the processes developed indicated that 3 RF presses could replace a typical auto-industry autoclave to achieve equal or greater throughput with possibly less capital cost and smaller footprint. Concepts for curved lamination identifying castable molds for prototyping were developed, which allowed Ceralink to obtain commitment to begin curved tooling development. The project significantly helped to advance RF lamination past the feasibility and novelty stage and into the realm of commercial acceptance as a viable alternative to autoclaves. The demonstration of autoclave-quality autoglass produced in just 1 minute with RF lamination, with validation by Pilkington, has fueled industry motivation to seriously consider RF lamination. The industry and other contacts and outreach made in the study of laminate markets (including 3 technical publications and 5 conference presentations), has resulted in a recent surge in RF lamination activity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Glass Lamination via Selective Radio Frequency Heating

This project focused on advancing radio-frequency (RF) lamination technology closer to commercial implementation, in order to reduce the energy intensity of glass lamination by up to 90%. Lamination comprises a wide range of products including autoglass, architectural safety and innovative design glass, transparent armor (e.g. bullet proof glass), smart glass, mirrors, and encapsulation of photovoltaics. Lamination is also the fastest growing segment of glass manufacturing, with photovoltaics, architectural needs, and an anticipated transition to laminated side windows in vehicles. The state-of-the-art for glass lamination is to use autoclaves, which apply heat and uniform gas pressure to bond the laminates over the course of 1 to 18 hours. Laminates consist of layers of glass or other materials bonded with vinyl or urethane interlayers. In autoclaving, significant heat energy is lost heating the chamber, pressurized air, glass racks, and the glass. In RF lamination, the heat is generated directly in the vinyl interlayer, causing it to heat and melt quickly, in just 1 to 10 minutes, without significantly heating the glass or the equipment. The main purpose of this project was to provide evidence that low energy, rapid RF lamination quality met the same standards as conventionally autoclaved windows. The development of concepts for laminating curved glass with RF lamination was a major goal. Other primary goals included developing a stronger understanding of the lamination product markets described above, and to refine the potential benefits of commercial implementation. The scope of the project was to complete implementation concept studies in preparation for continuation into advanced development, pilot studies, and commercial implementation. The project consisted of 6 main tasks. The first dealt with lamination with poly-vinyl butyral (PVB) interlayers, which prior work had shown difficulties in achieving good quality laminates, working with Pilkington North America. The second task dealt with a study of current lamination processes in the various laminate industries, and development of concepts for integrating RF lamination into new or existing processes. The third task explored the use of a non-destructive technique for analyzing laminate adhesion with the University of Illinois at Urbana-Champaign. The fourth task focused on developing concepts for curved glass lamination using RF lamination. The fifth and sixth tasks together comprised an analysis of laminate product markets, ranking for applicability and commercialization potential, and the development of commercialization strategies for those products. In addition, throughout the project as new experimental data and conventional process data were obtained, the benefits analysis of RF lamination was refined. The goals of the project described above were achieved, positioning RF lamination for the next stage growth envisioned in the original Industrial Grand Challenge proposal. Working with Pilkington North America, lamination of flat autoglass with PVB was achieved, meeting all 16 stringent industry tests. In particular, PVB laminates made with RF lamination passed environmental tests including the high temperature, 120°C bake test, without significant formation of bubbles (defects). The adhesion of PVB to glass was measured using the pummel method. Adhesion values ranging from 1 to 7 out of 10 were obtained. The significant process parameters affecting the environmental and adhesion performance were identified through a designed experiment. Pre-lamination process variables including PVB storage humidity and the de-airing process (vacuum or nip rolling) were significant, as well as the level of pressure applied to the laminate during the RF process. Analysis of manufacturing with RF lamination equipment, based on the processes developed indicated that 3 RF presses could replace a typical auto-industry autoclave to achieve equal or greater throughput with possibly less capital cost and smaller footprint. Concepts for curved lamination identifying castable molds for prototyping were developed, which allowed Ceralink to obtain commitment to begin curved tooling development. The project significantly helped to advance RF lamination past the feasibility and novelty stage and into the realm of commercial acceptance as a viable alternative to autoclaves. The demonstration of autoclave-quality autoglass produced in just 1 minute with RF lamination, with validation by Pilkington, has fueled industry motivation to seriously consider RF lamination. The industry and other contacts and outreach made in the study of laminate markets (including 3 technical publications and 5 conference presentations), has resulted in a recent surge in RF lamination activity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Outcomes of Sinonasal Cancer Treated With Proton Therapy

Purpose: To report disease outcomes after proton therapy (PT) for sinonasal cancer. Methods and Materials: Eighty-four adult patients without metastases received primary (13%) or adjuvant (87%) PT for sinonasal cancers (excluding melanoma, sarcoma, and lymphoma). Common histologies were olfactory neuroblastoma (23%), squamous cell carcinoma (22%), and adenoid cystic carcinoma (17%). Advanced stage (T3 in 25% and T4 in 69%) and high-grade histology (51%) were common. Surgical procedures included endoscopic resection alone (45%), endoscopic resection with craniotomy (12%), or open resection (30%). Gross residual disease was present in 26% of patients. Most patients received hyperfractionated PT (1.2 Gy [relative biological effectiveness (RBE)] twice daily, 99%) and chemotherapy (75%). The median PT dose was 73.8 Gy (RBE), with 85% of patients receiving more than 70 Gy (RBE). Prognostic factors were analyzed using Kaplan-Meier analysis and proportional hazards regression for multiple regression. Dosimetric parameters were evaluated using logistic regression. Serious, late grade 3 or higher toxicity was reported using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 4. The median follow-up was 2.4 years for all patients and 2.7 years among living patients. Results: The local control (LC), neck control, freedom from distant metastasis, disease-free survival, cause-specific survival, and overall survival rates were 83%, 94%, 73%, 63%, 70%, and 68%, respectively, at 3 years. Gross total resection and PT resulted in a 90% 3-year LC rate. The 3-year LC rate was 61% for primary radiation therapy and 59% for patients with gross disease. Gross disease was the only significant factor for LC on multivariate analysis, whereas grade and continuous LC were prognostic for overall survival. Six of 12 local recurrences were marginal. Dural dissemination represented 26% of distant recurrences. Late toxicity occurred in 24% of patients (with grade 3 or higher unilateral vision loss in 2%). Conclusions: Dose-intensified, hyperfractionated PT with or without concurrent chemotherapy results in excellent LC after gross total resection, and results in patients with gross disease are encouraging. Patients with high-grade histology are at greater risk of death from distant dissemination. Continuous LC is a major determinant of survival justifying aggressive local therapy in nearly all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRD-06: The Imaging and Radiation Oncology Core Houston (IROC Houston) QA Center International Activities Outside North America

Purpose: To describe the extent of IROC Houston’s (formerly the RPC) QA activities and audit results for radiotherapy institutions outside of North America (NA). Methods: The IROC Houston’s QA program components were designed to audit the radiation dose calculation chain from the NIST traceable reference beam calibration, to inclusion of dosimetry parameters used to calculate tumor doses, to the delivery of the radiation dose. The QA program provided to international institutions includes: 1) remote TLD/OSLD audit of machine output, 2) credentialing for advanced technologies, and 3) review of patient treatment records. IROC Houston uses the same standards and acceptance criteria for all of its audits whether for North American or international sites. Results: IROC Houston’s QA program has reached out to radiotherapy sites in 43 different countries since 2013 through their participation in clinical trials. In the past two years, 2,778 international megavoltage beam outputs were audited with OSLD/TLD. While the average IROC/Inst ratio is near unity for all sites monitored, there are international regions whose results are significantly different from the NA region. In the past 2 years, 477 and 87 IMRT H&N phantoms were irradiated at NA and international sites, respectively. Regardless of the OSLD beam audit results, the overall pass rate (87 percent) for all international sites (no region separation) is equal to the NA sites. Of the 182 international patient charts reviewed, 10.7 percent of the dose calculation points did not meet our acceptance criterion as compared to 13.6 percent for NA sites. The lower pass rate for NA sites results from a much larger brachytherapy component which has been shown to be more error prone. Conclusion: IROC Houston has expanded its QA services worldwide and continues a long history of improving radiotherapy dose delivery in many countries. Funding received for QA audit services from the Korean GOG, DAHANCA, EORTC, ICON and CMIC Group.

60 APPLIED LIFE SCIENCES↗

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

Transportability of exogenous microbial community correlates with interwell connectivity in deep aquifers

Subsurface resource engineering operations often utilize continuous injection of externally-sourced water into geological reservoirs for formation pressure maintenance, resource recovery or energy/waste storage. Such injected water generally contains naturally occurring microbes. Little is known, however, about how the injectate microbes transport through geological media as a community, how such transportability is affected by injector-producer connectivity, and whether such knowledge can be utilized for flowpath characterization. In this study, we analyzed daily-to-weekly timeseries microbial community data from the injected- and produced-fluids of a ten-month flow test at a deep, well-characterized engineered aquifer. We found that the injectate microbial community was distinct from the indigenous community at the amplicon sequence variant (ASV) level, and that the transportability of injectate community towards a given producer, quantified by an “nASV-Overlap” metric we propose, had strong and significant positive correlation with known injector-producer connectivities at our site. This suggests that the better the connectivity, the higher the probability for more injectate species to flow through the interwell region and arrive at a producer. Because interwell connectivity is an important yet usually unknown parameter in subsurface resource engineering, such correlation in turn points to nASV-Overlap as a useful indicator of interwell connectivity for aquifer characterization and long-term monitoring. Based on our findings, an nASV-Overlap-based microbial tracing approach was developed for characterizing and monitoring the relative connectivities across multiple producers with a given injector. A side-by-side comparison between the new nASV-Overlap approach and traditional artificial tracer methods is presented, and their respective strengths and limitations are discussed.

Deep biosphere↗

Distributed Dynamic State Estimator, Generator Parameter Estimation and Stability Monitoring Demonstration

This is the final report for this project that was performed in the period: October1, 2009 to June 30, 2013. In this project, a fully distributed high-fidelity dynamic state estimator (DSE) that continuously tracks the real time dynamic model of a wide area system with update rates better than 60 times per second is achieved. The proposed technology is based on GPS-synchronized measurements but also utilizes data from all available Intelligent Electronic Devices in the system (numerical relays, digital fault recorders, digital meters, etc.). The distributed state estimator provides the real time model of the system not only the voltage phasors. The proposed system provides the infrastructure for a variety of applications and two very important applications (a) a high fidelity generating unit parameters estimation and (b) an energy function based transient stability monitoring of a wide area electric power system with predictive capability. Also the dynamic distributed state estimation results are stored (the storage scheme includes data and coincidental model) enabling an automatic reconstruction and “play back” of a system wide disturbance. This approach enables complete play back capability with fidelity equal to that of real time with the advantage of “playing back” at a user selected speed. The proposed technologies were developed and tested in the lab during the first 18 months of the project and then demonstrated on two actual systems, the USVI Water and Power Administration system and the New York Power Authority’s Blenheim-Gilboa pumped hydro plant in the last 18 months of the project. The four main thrusts of this project, mentioned above, are extremely important to the industry. The DSE with the achieved update rates (more than 60 times per second) provides a superior solution to the “grid visibility” question. The generator parameter identification method fills an important and practical need of the industry. The “energy function” based transient stability monitoring opens up new ways to protect the power grid, better manage disturbances, confine their impact and in general improve the reliability and security of the system. Finally, as a by-product of the proposed research project, the developed system is able to “play back” disturbances by a click of a mouse. The importance of this by-product is evident by considering the tremendous effort exerted after the August 2003 blackout to piece together all the disturbance recordings, align them and recreate the sequence of events. This project has moved the state of art from fault recording by individual devices to system wide disturbance recording with “play back” capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗