Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Carbon and silicon background impurity control in undoped GaN layers grown with trimethylgallium and triethylgallium via metalorganic chemical vapor deposition

The unintentional impurity incorporation in GaN epitaxial layers impacts the electrical conductivity and optical properties of the films grown by metalorganic chemical vapor deposition (MOCVD). It is critical to control impurity-related states for device structure development. The aim of this work is to contribute to the understanding of the reasons for the presence of certain background impurities. In this paper, the unintentional impurity incorporation of carbon, hydrogen, oxygen, and silicon in undoped (u-) GaN films grown by low-pressure MOCVD were studied. Background impurity concentrations were evaluated by secondary ion mass spectroscopy (SIMS) to optimize growth parameters including V/III ratio, growth temperature (T g ), growth pressure (P g ), and gallium (Ga) precursors of trimethylgallium (TMG) or triethylgallium (TEG). Unintentional [C] and [Si] incorporations are found to be highly dependent on the growth parameters. Further, for the same growth conditions, u-GaN films grown with a TEG precursor exhibited a lower background concentration of C compared to that of GaN grown with TMG. However, the lowest background [C] achieved was grown with TMG using optimized conditions and exhibited [C]<4×10 15 cm -3 which was at the detection limit of the SIMS measurement. These results were measured for a u-GaN layer grown with TMG at 200 Torr, 1030°C, and a V/III of 3700. The lowest background [Si] of 4×10 15 cm -3 was achieved by growing with TMG at 200 Torr, 1000°C, and V/III of 650.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deterministic modeling of hybrid nonlinear effects in epsilon-near-zero thin films

In nonlinear optics, significant effort is concentrated on improving the strength and efficiency of interactions; however, experimentally investigating nonlinear materials is a complex, time-consuming, and costly investment. Moreover, it is often challenging to isolate, study, and optimize material parameters in an experiment due to complexities in the growth process. Recently, epsilon-near-zero materials have received a great deal of attention as promising nonlinear optical materials, but like many up-and-coming materials, the ability to explore and optimize their properties has been challenging. Here, we establish a framework to rapidly evaluate the performance of nonlinear epsilon-near-zero materials for both inter- and intraband effects in silico, requiring only an energy-momentum (E-k) diagram, linear optical properties, and experimental conditions. Measured nonlinear reflection and transmission in gallium-doped zinc oxide films are compared to the numerical framework for both intra- and interband excitation to verify accuracy across wavelength and irradiance while two figures of merit (FoMs) are introduced to quickly evaluate the performance of films without a full numerical framework. This capability is used to predict the performance of highly doped gallium nitride, cadmium oxide, zinc oxide, and indium tin oxide films, and efficient intra- and interband operation conditions are identified. Through this numerical framework and the FoMs, the exploration of unstudied epsilon-near-zero materials is enabled without the need for a nonlinear experiment, thereby accelerating the search for more efficient nonlinear materials and excitation conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of dose reduction in cardiac perfusion SPECT via optimization and choice of the image reconstruction strategy

Background: We investigated the extent to which the administered dose (activity) level can be reduced without sacrificing diagnostic accuracy for three reconstruction strategies for SPECT-myocardial perfusion imaging (MPI). Methods: We optimized the parameters of the three reconstruction strategies for perfusion-defect detection over a range of simulated administered dose levels using a set of hybrid studies (derived from 190 subjects) consisting of clinical SPECT-MPI data modified to contain realistic simulated lesions. The optimized strategies we considered are filtered backprojection (FBP) with no correction for degradations, ordered-subsets expectation-maximization (OS-EM) with attenuation correction (AC), scatter correction (SC), and resolution correction (RC), and OS-EM with scatter and resolution correction only. Each study was evaluated using a total perfusion deficit (TPD) score computed by the Quantitative Perfusion SPECT (QPS) software package. We conducted a receiver operating characteristics (ROC) study based on the TPD scores for each dose level and reconstruction strategy. Results: For FBP, the achieved optimum values of the area under the ROC curve (AUC) at 100%, 50%, 25%, and 12.5% of standard dose were 0.75, 0.74, 0.72, and 0.70, respectively, compared to 0.81, 0.79, 0.76, and 0.74 for OS-EM with AC–SC–RC and 0.78, 0.77, 0.74, 0.72 for OS-EM with SC–RC. Conclusions: Our results suggest that studies reconstructed by OS-EM with AC–SC–RC could possibly be reduced, on average, to 25% of the originally administered dose without causing diagnostic accuracy (AUC) to decrease below that of FBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure and electronic properties of rare earth DOBDC metal–organic-frameworks

In our report, we apply density functional theory (DFT) to investigate rare-earth metal organic frameworks (RE-MOFs), RE 12 (μ 3 -OH) 16 (C 8 O 6 H 4 ) 8 (C 8 O 6 H 5 ) 4 (RE = Y, Eu, Tb, Yb), and characterize the level of theory needed to accurately predict structural and electronic properties in MOF materials with 4f-electrons. A two-step calculation approach of geometry optimization with spin-restricted DFT and large core potential (LCPs), and detailed electronic structures with spin-unrestricted DFT with a full valence potential + Hubbard U correction is investigated. Spin-restricted DFT with LCPs resulted in good agreement between experimental lattice parameters and optimized geometries, while a full valence potential is necessary for accurate representation of the electronic structure. The electronic structure of Eu-DOBDC MOF suggested a strong dependence on the treatment of highly localized 4f-electrons and spin polarization, as well as variation within a range of Hubbard corrections (U = 1–9 eV). For Hubbard corrected spin-unrestricted calculations, a U value of 1–4 eV maintains the non-metallic character of the band gap with slight deviations in f-orbital energetics. When compared with experimentally reported results, the importance of the full valence calculation and the Hubbard correction in correctly predicting the electronic structure is highlighted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Affine Approximation of Parametrized Kernels and Model Order Reduction for Nonlocal and Fractional Laplace Models

In this work, we consider parametrized problems driven by spatially nonlocal integral operators with parameter-dependent kernels. In particular, kernels with varying nonlocal interaction radius $\delta > 0$ and fractional Laplace kernels, parametrized by the fractional power $s\in(0,1)$, are studied. Furthermore, in order to provide an efficient and reliable approximation of the solution for different values of the parameters, we develop the reduced basis method as a parametric model order reduction approach. Major difficulties arise since the kernels are not affine in the parameters, singular, and discontinuous. Moreover, the spatial regularity of the solutions depends on the varying fractional power $s$. To address this, we derive regularity and differentiability results with respect to $\delta$ and $s$, which are of independent interest for other applications such as optimization and parameter identification. We then use these results to construct affine approximations of the kernels by local polynomials. Finally, we certify the method by providing reliable a posteriori error estimators, which account for all approximation errors, and support the theoretical findings by numerical experiments.

97 MATHEMATICS AND COMPUTING↗

SIFT-based dense pixel tracking on 0.35 T cine-MR images acquired during image-guided radiation therapy with application to gating optimization

Purpose: To first demonstrate the viability of applying an image processing technique for tracking regions on low-contrast cine-MR images acquired during image-guided radiation therapy, and then outline a scheme that uses tracking data for optimizing gating results in a patient-specific manner. Methods: A first-generation MR-IGRT system—treating patients since January 2014—integrates a 0.35 T MR scanner into an annular gantry consisting of three independent Co-60 sources. Obtaining adequate frame rates for capturing relevant patient motion across large fields-of-view currently requires coarse in-plane spatial resolution. This study initially (1) investigate the feasibility of rapidly tracking dense pixel correspondences across single, sagittal plane images (with both moderate signal-to-noise and spatial resolution) using a matching objective for highly descriptive vectors called scale-invariant feature transform (SIFT) descriptors associated to all pixels that describe intensity gradients in local regions around each pixel. To more accurately track features, (2) harmonic analysis was then applied to all pixel trajectories within a region-of-interest across a short training period. In particular, the procedure adjusts the motion of outlying trajectories whose relative spectral power within a frequency bandwidth consistent with respiration (or another form of periodic motion) does not exceed a threshold value that is manually specified following the training period. To evaluate the tracking reliability after applying this correction, conventional metrics—including Dice similarity coefficients (DSCs), mean tracking errors (MTEs), and Hausdorff distances (HD)—were used to compare target segmentations obtained via tracking to manually delineated segmentations. Upon confirming the viability of this descriptor-based procedure for reliably tracking features, the study (3) outlines a scheme for optimizing gating parameters—including relative target position and a tolerable margin about this position—derived from a probability density function that is constructed using tracking results obtained just prior to treatment. Results: The feasibility of applying the matching objective for SIFT descriptors toward pixel-by-pixel tracking on cine-MR acquisitions was first retrospectively demonstrated for 19 treatments (spanning various sites). Both with and without motion correction based on harmonic analysis, sub-pixel MTEs were obtained. A mean DSC value spanning all patients of 0.916 ± 0.001 was obtained without motion correction, with DSC values exceeding 0.85 for all patients considered. While most patients show accurate tracking without motion correction, harmonic analysis does yield substantial gain in accuracy (defined using HDs) for three particularly challenging subjects. An application of tracking toward a gating optimization procedure was then demonstrated that should allow a physician to balance beam-on time and tissue sparing in a patient-specific manner by tuning several intuitive parameters. Conclusions: Tracking results show high fidelity in assessing intrafractional motion observed on cine-MR acquisitions. Incorporating harmonic analysis during a training period improves the robustness of the tracking for challenging targets. The concomitant gating optimization procedure should allow for physicians to quantitatively assess gating effectiveness quickly just prior to treatment in a patient-specific manner.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electronic, magnetic, and structural properties of V2CoAl: Experimental and computational study

Here, we present results of combined experimental and computations study of V2CoAl, a Heusler alloy that exhibits nearly perfect spin-polarization. Our calculations indicate that this material maintains a high degree of spin-polarization (over 90%) in the wide range of lattice parameters, except at the largest considered unit cell volume. The magnetic alignment of V2CoAl is ferrimagnetic, due to the antialignment of the magnetic moments of vanadium atoms in their two sublattices. The calculated total magnetic moment per formula unit is nearly integer at the optimal lattice parameter and at the smaller volumes of the unit cell, but it deviated from the integer values as the unit cell expands. This is consistent with the calculated variation in the degree of spin polarization with lattice constant. The expected ferrimagnetic behavior has been observed in the arc-melted V2CoAl sample, with a Curie temperature of about 80 K. However, the saturation magnetization is significantly smaller than the theoretical prediction of ∼2 μB/f.u., most likely due to the observed B2-type atomic disorder. The samples exhibit metallic electron transport across the measurement range of 2 K to 300 K.

Kharel, Parashu (ORCID:0000000171330718)↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistic inversion of multi-zone transition probability models for aquifer characterization in alluvial fans

Understanding the heterogeneity arising from the complex architecture of sedimentary sequences in alluvial fans is challenging. This study develops a statistical inverse framework in a multi-zone transition probability approach for characterizing the heterogeneity in alluvial fans. An analytical solution of the transition probability matrix is used to define the statistical relationships among different hydrofacies and their mean lengths, integral scales, and volumetric proportions. A statistical inversion is conducted to identify the multi-zone transition probability models and estimate the optimal statistical parameters using the modified Gauss–Newton–Levenberg–Marquardt method. The Jacobian matrix is computed by the sensitivity equation method, which results in an accurate inverse solution with quantification of parameter uncertainty. We use the Chaobai River alluvial fan in the Beijing Plain, China, as an example for elucidating the methodology of alluvial fan characterization. The alluvial fan is divided into three sediment zones. In each zone, the explicit mathematical formulations of the transition probability models are constructed with optimized different integral scales and volumetric proportions. The hydrofacies distributions in the three zones are simulated sequentially by the multi-zone transition probability-based indicator simulations. Finally, the result of this study provides the heterogeneous structure of the alluvial fan for further study of flow and transport simulations.

54 ENVIRONMENTAL SCIENCES↗

Dosimetric aspects of inverse-planned modulated-arc total-body irradiation

Purpose: To develop optimal beam parameters and to verify the dosimetric aspects of the recently developed modulated-arc total-body irradiation (MATBI) technique, which delivers an inverse-planned dose to the entire body using gantry rotation. Methods: The patient is positioned prone and supine underneath the gantry at about 2 m source-to-surface distance (SSD). Then, up to 28 beams irradiate the patient from different gantry angles. Based on full-body computed-tomography (CT) images of the patient, the weight of each beam is optimized, using inverse planning, to create a uniform body dose. This study investigates how to best simulate patients and the ideal beam setup parameters, such as field size, number of beams, and beam geometry, for treatment time and dose homogeneity. In addition, three anthropomorphic water phantoms were constructed and utilized to verify the accuracy of dose delivery, with both diode array and ion chamber measurements. Furthermore, to improve the accuracy of the new technique, a beam model is created specifically for the extended-SSD positioning for MATBI. Results: Low dose CT scans can be utilized for dose calculations without affecting the accuracy. The largest field size of 40 Multiplication-Sign 40 cm{sup 2} was found to deliver the most uniform dose in the least amount of time. Moreover, a higher number of beams improves dose homogeneity. The average dose discrepancy between ion chamber measurements and extended-SSD beam model calculations was 1.2%, with the largest discrepancy being 3.2%. This average dose discrepancy was 1.4% with the standard beam model for delivery at isocenter. Conclusions: The optimum beam setup parameters, regarding dose uniformity and treatment duration, are laid out for modulated-arc TBI. In addition, the presented dose measurements show that these treatments can be delivered accurately. These measurements also indicated that a new beam model did not significantly improve the accuracy of dose calculations. The optimum beam setup parameters along with the measurements performed to ensure accurate dose delivery serve as a useful guide for the clinical implementation of MATBI.

60 APPLIED LIFE SCIENCES↗

Machine learning-aided inverse design for biogas upgrading through biological CO 2 conversion

The biogas upgrading process through bioconversion of CO 2 to CH 4 by hydrogenotrophic methanogens is an attractive strategy for energy decarbonation. Many studies have optimized operational parameters to improve key performance indicators such as CH 4 % and H 2 utilization efficiency. However, inconsistent laboratory conditions make it challenging to compare results. Existing models for analyzing operating conditions can only assess the impact of individual conditions and lack the ability to simultaneously optimize multiple conditions. To address this, two XGBoost models were built with R 2 of 0.779 and 0.903 with data collected from literatures and were embedded into multi-objective partitive swarm optimization algorithm to optimal operating conditions. Predictions were compared with experimental validations under optimized conditions, revealing an 8.50% and 2.95% relative error in CH 4 % and H 2 conversion rate, respectively. This approach streamlines biogas upgrading processes, offering a data-driven solution to enhance efficiency and consistency in the pursuit of sustainable methane production.

Biogas upgrading↗

Dark Energy Survey Year 3 results: Optimizing the lens sample in a combined galaxy clustering and galaxy-galaxy lensing analysis

We investigate potential gains in cosmological constraints from the combination of galaxy clustering and galaxy-galaxy lensing by optimizing the lens galaxy sample selection using information from Dark Energy Survey (DES) Year 3 data and assuming the DES Year 1 metacalibration sample for the sources. We explore easily reproducible selections based on magnitude cuts in i-band as a function of (photometric) redshift, zphot, and benchmark the potential gains against those using the well-established redMaGiC [E. Rozo et al., Mon. Not. R. Astron. Soc. 461, 1431 (2016)MNRAA40035-871110.1093/mnras/stw1281] sample. We focus on the balance between density and photometric redshift accuracy, while marginalizing over a realistic set of cosmological and systematic parameters. Our optimal selection, the MagLim sample, satisfies i<4zphot+18 and has ∼30% wider redshift distributions but ∼3.5 times more galaxies than redMaGiC. Assuming a wCDM model (i.e. with a free parameter for the dark energy equation of state) and equivalent scale cuts to mitigate nonlinear effects, this leads to 40% increase in the figure of merit for the pair combinations of Ωm, w, and σ8, and gains of 16% in σ8, 10% in Ωm, and 12% in w. Similarly, in ΛCDM, we find an improvement of 19% and 27% on σ8 and Ωm, respectively. We also explore flux-limited samples with a flat magnitude cut finding that the optimal selection, i<22.2, has ∼7 times more galaxies and ∼20% wider redshift distributions compared to MagLim, but slightly worse constraints. We show that our results are robust with respect to the assumed galaxy bias and photometric redshift uncertainties with only moderate further gains from increased number of tomographic bins or the inclusion of bin cross-correlations, except in the case of the flux-limited sample, for which these gains are more significant.

79 ASTRONOMY AND ASTROPHYSICS↗

Deconvolving distribution of relaxation times, resistances and inductance from electrochemical impedance spectroscopy via statistical model selection: Exploiting structural-sparsity regularization and data-driven parameter tuning

The distribution of relaxation times (DRT) has drawn increasing attention for interpreting electrochemical impedance spectroscopy (EIS). Deconvolution of DRT from EIS is a challenging ill-posed problem that requires regularization methods. In this work, we formulate DRT reconstruction task as a statistical model selection problem with structural-sparsity penalties. We utilize the Elastic net regularization that simultaneously benefits from Ridge and Lasso regularizations with optimal tuning parameter automatically determined by the information criteria. We benchmark our approach on four synthetic experiments (a ZARC element, ZARC mixtures, a RC circuit and a Fractal element) and two real EIS datasets of a Lithium ion battery and an organic-inorganic halide class of perovskites in oxygen environment at different gas pressures. We demonstrate the superiority of proposed model selection procedure, that is capable of eliminating pseudo peaks and representing asymmetries in DRT as well as precisely estimating resistances. Here, we highlight our approach is robust to reducing and subsampling EIS frequency range, making it a promising tool for timing-resolved, localized and large scale EIS data analysis. For the Lithium ion battery data analysis, we extend the classical DRT model to incorporate the inductive effect and illustrate DRT as a guidance for equivalent circuit modeling to refine impedance reconstruction at low risks of overfitting. Furthermore, the structural-sparsity regularization could be extended for multidimensional and Bayesian EIS data analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space charge modeling in electron-beam irradiated polyethylene: Fitting model and experiments

A numerical model for describing charge accumulation in electron-beam irradiated low density polyethylene has been put forward recently. It encompasses the generation of positive and negative charges due to impinging electrons and their transport in the insulation. However, the model was not optimized to fit all the data available regarding space charge dynamics obtained using up-to-date pulsed electro-acoustic techniques. In the present approach, model outputs are compared with experimental space charge distribution obtained during irradiation and post-irradiation, the irradiated samples being in short circuit conditions or with the irradiated surface at a floating potential. A unique set of parameters have been used for all the simulations, and it encompasses the transport parameters already optimized for charge transport in polyethylene under an external electric field. The model evolution in itself consists in describing the recombination between positive and negative charges according to the Langevin formula, which is physically more accurate than the previous description and has the advantage of reducing the number of adjustable parameters of the model. This also provides a better description of the experimental behavior underlining the importance of recombination processes in irradiated materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of cosmological models using time delay lenses

The use of time-delay gravitational lenses to examine the cosmological expansion introduces a new standard ruler with which to test theoretical models. The sample suitable for this kind of work now includes 12 lens systems, which have thus far been used solely for optimizing the parameters of ΛCDM. In this paper, we broaden the base of support for this new, important cosmic probe by using these observations to carry out a one-on-one comparison between competing models. The currently available sample indicates a likelihood of ∼70%-80% that the R {sub h} = ct universe is the correct cosmology versus ∼20%-30% for the standard model. This possibly interesting result reinforces the need to greatly expand the sample of time-delay lenses, e.g., with the successful implementation of the Dark Energy Survey, the VST ATLAS survey, and the Large Synoptic Survey Telescope. In anticipation of a greatly expanded catalog of time-delay lenses identified with these surveys, we have produced synthetic samples to estimate how large they would have to be in order to rule out either model at a ∼99.7% confidence level. We find that if the real cosmology is ΛCDM, a sample of ∼150 time-delay lenses would be sufficient to rule out R {sub h} = ct at this level of accuracy, while ∼1000 time-delay lenses would be required to rule out ΛCDM if the real universe is instead R {sub h} = ct. This difference in required sample size reflects the greater number of free parameters available to fit the data with ΛCDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Synthesis of Nd3BSi2O10 using a LiCl-flux method

This paper details synthesis methods that were used to fabricate phase-pure Nd3BSi2O10 using a LiCl-flux method. In this study, a variety of conditions were evaluated to find the optimal processing parameters for maximizing the Nd3BSi2O10 yield including the mass ratio of LiCl to target mass of Nd3BSi2O10 including 1:3, 1:2, 1:1, 2:1, and 6:1 as well as the soak temperature (i.e., 700, 800, or 900°C) at the 1:1 ratio. It was found that the optimal ratio of LiCl:Nd3BSi2O10 was 1:1 and the optimal heat-treatment temperature was 900°C. Product made from the 1:1 material synthesized at 900°C was recovered and fired at temperatures of 925–1350°C. After 4-h firings at temperatures of 925–1100°C, the Nd3BSi2O10 phase purity was found to be 100% with powder X-ray diffraction, but started to decompose at the longer firing times at 1100°C and higher temperatures (1350°C) at the 4-h dwell time. The durability of the Nd3BSi2O10 product was examined in flow-through conditions at pH 5.6 and 7.7 and 90°C. The release rate of Nd from the material at pH 5.6 was calculated to be 1.6×10-3 g m-2 d-1 and was determined to have a maximum release rate of Nd at pH 7.7 of 5.6×10-3 g m-2 d-1. These release rates are roughly three orders of magnitude lower than what is typically measured from glass waste forms.

Kroll, Jared O.↗

Noise analysis of optimized Ge/Ge{sub 1−x}Sn{sub x}/Ge p–n–p heterojunction phototransistors for long-wavelength optical receivers

Present literature investigates noise analysis and optimal design for Ge/Ge{sub 1−x}Sn{sub x}/Ge based p–n–p heterojunction phototransistors (HPT) for long-wavelength optical receivers. We calculate gain, noise powers, signal-to-noise ratio, absorption coefficient and optical responsivity of proposed GeSn-based HPT and investigate their dependence on various structural parameters to optimize the design. The proposed HPT incorporates Ge{sub 1−x}Sn{sub x} alloy in the base layer as the active layer, allow to extend the photo detection range from near infrared to mid-infrared to achieve a wide range of detection. The results show that the signal-to-noise ratio (SNR) is strongly dependent on the operating frequency and the introduction of Sn in the base layer can improve the signal-to-noise ratio in the high-frequency region. The calculated results also show that even in the presence of small defects and misfit dislocations at the heterointerfaces, high SNR is still achievable for the proposed structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗