Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Time-Zone-Pattern Satellite Broadcasting Antenna

Direct-broadcast satellite antenna designs provide contoured beams to match four time zones in 48 contiguous states and spot beams for Alaska, Hawaii, and Puerto Rico presented in 29-page report. Includes descriptions of procedures used to arrive at optimized designs. Arrangements, amplitudes, and phases of antenna feeds presented in tables. Gain contours shown graphically. Additional tables of performance data given for cities in service area of Eastern satellite.

Galindo, Victor↗

Dielectric resonator method for determining gap symmetry of superconductors through anisotropic nonlinear Meissner effect

We present a new measurement method which can be used to image the gap nodal structure of superconductors whose pairing symmetry is under debate. This technique utilizes a high quality factor microwave resonance involving the sample of interest. While supporting a circularly symmetric standing wave current pattern, the sample is perturbed by a scanned laser beam, creating a photoresponse that was previously shown to reveal the superconducting gap anisotropy. Simulation and the measurement of the photoresponse of an unpatterned Nb film show less than 8% anisotropy, as expected for a superconductor with a nearly isotropic energy gap along with expected systematic uncertainty. On the other hand, measurement of a YBa 2 Cu 3 O 7- δ thin film shows a clear 4-fold symmetric image with ~12.5% anisotropy, indicating the well-known 4-fold symmetric d x 2 - y 2 gap nodal structure in the ab -plane. The deduced gap nodal structure can be further cross-checked by low temperature surface impedance data, which are simultaneously measured. The important advantage of the presented method over the previous spiral resonator method is that it does not require a complicated lithographic patterning process which limits one from testing various kinds of materials due to photoresponse arising from patterning defects. This advantage of the presented technique, and the ability to measure unpatterned samples such as planar thin films and single crystals, enables one to survey the pairing symmetry of a wide variety of unconventional superconductors.

47 OTHER INSTRUMENTATION↗

Pulsed Laser-Assisted Focused Electron-Beam-Induced Etching of Titanium with XeF 2 : Enhanced Reaction Rate and Precursor Transport

We introduce a laser-assisted focused electron-beam-induced etching (LA-FEBIE) process which is a versatile, direct write nanofabrication method that allows nanoscale patterning and editing; we do this in order to enhance the etch rate of electron-beam-induced etching. The results demonstrate that the titanium electron stimulated etch rate via the XeF2 precursor can be enhanced up to a factor of 6 times with an intermittent pulsed laser assist. Moreover, the evolution of the etching process is correlated to in situ stage current measurements and scanning electron micrographs as a function of time. Finally, the increased etch rate is attributed to photothermally enhanced Ti–F reaction and TiF4 desorption and in some regimes enhanced XeF2 surface diffusion to the reaction zone.

36 MATERIALS SCIENCE↗

Three-dimensional mapping of multiple filament arrays

We study experimentally and numerically the spatiotemporal dynamics of the multiple filament arrays excited by self-focusing of intense elliptical laser beams in fused silica. Our results demonstrate that although multiple filament arrays emerge as apparently regular patterns in the space domain, the spatiotemporal dynamics of the individual filaments is governed by the input-beam power and the input-beam ellipticity. In the case of moderate input-beam ellipticity, the individual filaments propagate in curved trajectories arising from skewed (spatiotemporal) coherence. The spatiotemporal propagation dynamics is regularized by increasing the input-beam ellipticity, and in part due to permanent modifications of fused silica that occur under intense irradiation. In this case, strong pulse reshaping and shock-front generation are observed, which yields a regular array of very short (<5 fs) superluminally propagating localized peaks in the leading front, followed by the subpulses centered on the input-pulse top, and trailed by subluminally propagating pulses with rather complex transverse intensity distribution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

New Technique Sees Bacterial Growth Quicker

Researchers at Pacific Northwest National Laboratory have developed a patent-pending technique for faster and improved way to count bacteria and measure their growth, without killing the sample, by using a white light interferometer. This innovation is available for licensing. For more information, contact Commercialization Manager Jennifer Lee at jennifer.lee@pnnl.gov WLIs are microscopes that split a beam of light and then look for characteristic wavy patterns that appear in images as the two halves of the light ‘interfere’ with each other when recombined. The interference patterns translate into a measurement of different heights or textures on the surface of what’s being viewed and can track it as it changes. Using this previously unexplored approach, researchers were able to quickly see, in great detail, barely perceptible changes in heights down to three nanometers – more than 10,000 times smaller than the diameter of a human hair - in the topography of a sample. Being able to see very detailed height changes is important for bacterial colonies which, the team observed, grow slowly upward as well as out.

47 OTHER INSTRUMENTATION↗

An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers

We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bandgap tailoring of rutile TiO{sub 2}(110) via surface patterning with electron cyclotron resonance sputtering

Crystalline TiO{sub 2} nanodots have been formed on single crystal rutile TiO{sub 2}(110) surfaces via ion beam sputtering method by utilizing Ar ion beams from electron cyclotron resonance source. Nearly five times enhancement in absorbance of visible light, {approx}5 times increase in luminescence, and {approx}0.1 eV narrowing of bandgap are observed for nanodot-patterned surfaces, in the absence of any dopant material. Formation of crystalline rutile TiO{sub 2} nanodots and development of Ti interstitials on the TiO{sub 2}(110) surface, after ion beam sputtering, are responsible for these observations. Results suggest that these nanodot-patterned rutile TiO{sub 2} surfaces can become effective photocatalysts.

36 MATERIALS SCIENCE↗

Simultaneous Conoscopic Holography and Raman Spectroscopy

A new instrument was developed for chemical characterization of surfaces that combines the analytical power of Raman spectroscopy with the three-dimensional topographic information provided by conoscopic holography. The figure schematically depicts the proposed hybrid instrument. The output of the conoscopic holographic portion of the instrument is a topographical map of the surface; the output of the Raman portion of the instrument is hyperspectral Raman data, from which the chemical and/or biological composition of the surface would be deduced. By virtue of the basic principles of design and operation of the instrument, the hyperspectral image data would be inherently spatially registered with the topographical data. In conoscopic holography, the object and reference beams of classical holography are replaced by the ordinary and extraordinary components generated by a single beam traveling through a birefringent, uniaxial crystal. In the basic conoscopic configuration, a laser light is projected onto a specimen and the resulting illuminated spot becomes a point source of diffuse light that propagates in every direction. The laser beam is rasterscanned in two dimensions (x and y) perpendicular to the beam axis (z), and at each x,y location, the pattern of interference between the ordinary and extraordinary rays is recorded. The recorded interferogram constitutes the conoscopic hologram. Of particular significance for the proposed instrument is that the conoscopic hologram contains information on the z coordinate (height) of the illuminated surface spot. Hence, a topographical map of the specimen is constructed point-by-point by rastering the laser beam in the x and y directions and correlating the x and y coordinates with the z information obtained from the interferograms. Conoscopic imaging is an established method, and conoscopic laboratory instruments for surface metrology are commercially available. In Raman spectroscopy of a surface, one measures the spectrum of laser light scattered inelastically from a laser-illuminated spot on the surface. The wavelengths of the inelastically scattered light differ from that of the incident laser beam by amounts that correspond to the energies of molecular vibrations. The resulting vibrational spectrum can be used to identify the molecules. Raman spectroscopy is a standard laboratory technique for identifying mineralogical, biological, and other specific chemical compositions.

Schramm, Harry F.↗

Complex laterally ordered InGaAs and InAs quantum dots by guided self-organized anisotropic strain engineering on shallow- and deep-patterned GaAs (311)B substrates

Self-organized anisotropic strain engineering guided on shallow- and deep-patterned GaAs (311)B substrates is exploited for formation of complex laterally ordered architectures of connected InGaAs quantum dot (QD) arrays and isolated InAs QD groups by molecular beam epitaxy. The combination of strain and step engineerings on shallow stripe-patterned substrates transforms the periodic spotlike arrangement of the InGaAs QD arrays and InAs QD groups (on planar substrates) into a zigzag arrangement of periodic stripes which are well ordered over macroscopic areas on zigzag mesa-patterned substrates. In contrast, the formation of slow-growing facets on deep-patterned substrates produces QD-free mesa sidewalls, while InGaAs QD arrays and InAs QD groups form on the GaAs (311)B top and bottom planes with arrangements modified only close to the sidewalls depending on the sidewall orientation. The QDs on the shallow- and deep-patterned substrates exhibit excellent optical properties up to room temperature. Therefore, the concept of guided self-organization demonstrated on shallow-patterned (due to steps) and deep-patterned (due to facets) substrates is highlighted for creation of complex architectures of laterally ordered QDs for future quantum functional devices.

36 MATERIALS SCIENCE↗

Fast growth of graphene patterns by laser direct writing

Rapid single-step fabrication of graphene patterns was developed using laser-induced chemical vapor deposition (LCVD). A laser beam irradiates a thin nickel foil in a CH{sub 4} and H{sub 2} environment to induce a local temperature rise, thereby allowing the direct writing of graphene patterns in precisely controlled positions at room temperature. Line patterns can be achieved with a single scan without pre- or postprocesses. Surprisingly, the growth rate is several thousand times faster than that of general CVD methods. The discovery and development of the LCVD growth process provide a route for the rapid fabrication of graphene patterns for various applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of broadband X-ray interference lithography large area exposure system

The single-exposure patterned area is about several 10{sup 2} × 10{sup 2} μm{sup 2} which is mainly decided by the mask area in multi-beam X-ray interference lithography (XIL). The exposure area is difficult to stitch to a larger one because the patterned area is surrounded by 0th diffraction exposure areas. To block the 0th diffraction beams precisely and effectively, a new large area exposure technology is developed in the Shanghai Synchrotron Radiation Facility by applying an order-sorting aperture with a new in situ monitoring scheme in the XIL system. The patterned area could be stitched readily up to several square centimeters and even bigger by this technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Three-Dimensional Display System

A desktop-scale, computer-controlled display system, initially developed for NASA and now known as the VolumeViewer(TradeMark), generates three-dimensional (3D) images of 3D objects in a display volume. This system differs fundamentally from stereoscopic and holographic display systems: The images generated by this system are truly 3D in that they can be viewed from almost any angle, without the aid of special eyeglasses. It is possible to walk around the system while gazing at its display volume to see a displayed object from a changing perspective, and multiple observers standing at different positions around the display can view the object simultaneously from their individual perspectives, as though the displayed object were a real 3D object. At the time of writing this article, only partial information on the design and principle of operation of the system was available. It is known that the system includes a high-speed, silicon-backplane, ferroelectric-liquid-crystal spatial light modulator (SLM), multiple high-power lasers for projecting images in multiple colors, a rotating helix that serves as a moving screen for displaying voxels [volume cells or volume elements, in analogy to pixels (picture cells or picture elements) in two-dimensional (2D) images], and a host computer. The rotating helix and its motor drive are the only moving parts. Under control by the host computer, a stream of 2D image patterns is generated on the SLM and projected through optics onto the surface of the rotating helix. The system utilizes a parallel pixel/voxel-addressing scheme: All the pixels of the 2D pattern on the SLM are addressed simultaneously by laser beams. This parallel addressing scheme overcomes the difficulty of achieving both high resolution and a high frame rate in a raster scanning or serial addressing scheme. It has been reported that the structure of the system is simple and easy to build, that the optical design and alignment are not difficult, and that the system can be built by use of commercial off-the-shelf products. A prototype of the system displays an image of 1,024 by 768 by 170 (=133,693,440) voxels. In future designs, the resolution could be increased. The maximum number of voxels that can be generated depends upon the spatial resolution of SLM and the speed of rotation of the helix. For example, one could use an available SLM that has 1,024 by 1,024 pixels. Incidentally, this SLM is capable of operation at a switching speed of 300,000 frames per second. Implementation of full-color displays in future versions of the system would be straightforward: One could use three SLMs for red, green, and blue, respectively, and the colors of the voxels could be automatically controlled. An optically simpler alternative would be to use a single red/green/ blue light projector and synchronize the projection of each color with the generation of patterns for that color on a single SLM.

Geng, Jason↗

Hierarchical, Self-Assembled Metasurfaces via Exposure-Controlled Reflow of Block Copolymer-Derived Nanopatterns

Here, nanopatterning for the fabrication of optical metasurfaces entails a need for high-resolution approaches like electron beam lithography that cannot be readily scaled beyond prototyping demonstrations. Block copolymer thin film self-assembly offers an attractive alternative for producing periodic nanopatterns across large areas, yet the pattern feature sizes are fixed by the polymer molecular weight and composition. Here, a general strategy is reported that overcomes the limitation of fixed feature size by treating the copolymer thin film as a hierarchical resist, in which the nanoscale pattern motif is defined by self-assembly. Feature sizes can then be tuned by thermal reflow controlled locally by irradiative crosslinking or chemical alteration using lithographic ultraviolet light or electron beam exposure. Using blends of polystyrene-block-poly(methylmethacrylate) (PS-b-PMMA) with PS and PMMA homopolymer, we demonstrate both self-assembled PS grating and hexagonal hole patterns; exposure-controlled reflow is then used to reduce hole diameter by as much as 50% or increase PS grating linewidth by more than 180%. Transferring these nanopatterns, or their inverse obtained by a lift-off approach, into silicon yields structural colors that may be prescriptively controlled based on nanoscale feature size. Furthermore, patterned exposure enables area-selective feature size control, yielding uniform structural color patterns across centimeter square areas. Electron beam lithography is also used to show that the lithographic resolution of this selective-area control can be extended to the nanoscale dimensions of the self-assembled features. The exposure-controlled reflow approach demonstrated here takes a pivotal step towards fabricating complex, hierarchical optical metasurfaces using scalable self-assembly methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

LISA Telescope Sensitivity Analysis

The results of a LISA telescope sensitivity analysis will be presented, The emphasis will be on the outgoing beam of the Dall-Kirkham' telescope and its far field phase patterns. The computed sensitivity analysis will include motions of the secondary with respect to the primary, changes in shape of the primary and secondary, effect of aberrations of the input laser beam and the effect the telescope thin film coatings on polarization. An end-to-end optical model will also be discussed.

Waluschka, Eugene↗

Imaging single electrons to enable the generation of ultrashort beams for single-shot femtosecond relativistic electron diffraction

The generation and control of relativistic electron beams well suited for ultrafast electron diffraction application has rapidly advanced, greatly benefiting from the overlap in techniques and expertise with the accelerator community. However, imaging the diffracted MeV electrons with high detection efficiency has remained an under-explored area. In this paper, we report on a quantitative study of the imaging of MeV electrons using a detection system consisting of a phosphor screen, a lens-coupling optics, and a charge-coupled device camera. It is shown that every MeV electron in the beam yields a signal well above the camera noise. With this detection efficiency, only {approx}10{sup 5} electrons per pulse are needed to obtain a high quality single-shot diffraction pattern from a crystalline sample. We measured that such a low charge beam can be as short as 30 fs rms. Further, we discuss the possibility of compressing these electron beams to sub-5 fs rms bunch length by velocity bunching using a short high gradient rf accelerating structure scheduled to be installed next year at the UCLA Pegasus Laboratory. This opens the possibility of single-shot determinations of structural changes in many ultrafast physical processes like nonequilibrium phonon dynamics or relaxation pathways in systems with strong electron-phonon coupling.

43 PARTICLE ACCELERATORS↗

Preliminary experimental investigation of a dual-band relativistic backward wave oscillator with dual beams

A dual-band relativistic backward wave oscillator with dual electron beams generating C-band and X-band microwaves is investigated experimentally. The frequencies, powers, and radiation patterns of the dual-band microwaves are measured. With the diode voltage of 657 kV and the total beam current of 14 kA guided by a magnetic field of about 1.7 T, the dual-band microwaves are generated with dominant frequencies of 4.58 and 8.30 GHz close to the results from the particle-in-cell simulation. The powers of the C-band and X-band microwaves are 520 and 113 MW, respectively. The effects of variations in the guiding magnetic field and diode voltage on the powers of the dual-band microwaves are presented and discussed. The radiation patterns of the dual-band microwaves from the radiating antenna are tested both corresponding to a TM{sub 01} mode and the independency of the operation processes of them is discussed.

43 PARTICLE ACCELERATORS↗

An EPID response calculation algorithm using spatial beam characteristics of primary, head scattered and MLC transmitted radiation

We have developed an independent algorithm for the prediction of electronic portal imaging device (EPID) response. The algorithm uses a set of images [open beam, closed multileaf collimator (MLC), various fence and modified sweeping gap patterns] to separately characterize the primary and head-scatter contributions to EPID response. It also characterizes the relevant dosimetric properties of the MLC: Transmission, dosimetric gap, MLC scatter [P. Zygmansky et al., J. Appl. Clin. Med. Phys. 8(4) (2007)], inter-leaf leakage, and tongue and groove [F. Lorenz et al., Phys. Med. Biol. 52, 5985-5999 (2007)]. The primary radiation is modeled with a single Gaussian distribution defined at the target position, while the head-scatter radiation is modeled with a triple Gaussian distribution defined downstream of the target. The distances between the target and the head-scatter source, jaws, and MLC are model parameters. The scatter associated with the EPID is implicit in the model. Open beam images are predicted to within 1% of the maximum value across the image. Other MLC test patterns and intensity-modulated radiation therapy fluences are predicted to within 1.5% of the maximum value. The presented method was applied to the Varian aS500 EPID but is designed to work with any planar detector with sufficient spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗