Preliminary Design, Testing, and Performance of the LOFTID Navigation System
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Estimating effects due to an urban IND (improvised nuclear device) on underground structures and underground utilities is a challenging task. Nuclear effects tests performed at the Nevada Test Site (NTS) during the era of nuclear weapons testing provides much information on how underground military structures respond. Transferring this knowledge to answer questions about the urban civilian environment is needed to help plan responses to IND scenarios. Explosions just above the ground surface can only couple a small fraction of the blast energy into an underground shock. The various forms of nuclear radiation have limited penetration into the ground. While the shock transmitted into the ground carries only a small fraction of the blast energy, peak stresses are generally higher and peak ground displacement is lower than in the air blast. While underground military structures are often designed to resist stresses substantially higher than due to the overlying rocks and soils (overburden), civilian structures such as subways and tunnels would generally only need to resist overburden conditions with a suitable safety factor. Just as we expect the buildings themselves to channel and shield air blast above ground, basements and other underground openings as well as changes of geology will channel and shield the underground shock wave. While a weaker shock is expected in an urban environment, small displacements on very close-by faults, and more likely, soils being displaced past building foundations where utility lines enter could readily damaged or disable these services. Immediately near an explosion, the blast can 'liquefy' a saturated soil creating a quicksand-like condition for a period of time. We extrapolate the nuclear effects experience to a Chicago-based scenario. We consider the TARP (Tunnel and Reservoir Project) and subway system and the underground lifeline (electric, gas, water, etc) system and provide guidance for planning this scenario.
Abstract Not Provided
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Materials Protection, Accounting, and Control Technologies (MPACT) campaign, within the U.S. Department of Energy Office of Nuclear Energy, has developed a Virtual Facility Distributed Test Bed for safeguards and security design for future nuclear fuel cycle facilities. The purpose of the Virtual Test Bed is to bring together experimental and modeling capabilities across the U.S. national laboratory and university complex to provide a one-stop-shop for advanced Safeguards and Security by Design (SSBD). Experimental testing alone of safeguards and security technologies would be cost prohibitive, but testbeds and laboratory processing facilities with safeguards measurement opportunities, coupled with modeling and simulation, provide the ability to generate modern, efficient safeguards and security systems for new facilities. This Virtual Test Bed concept has been demonstrated using a generic electrochemical reprocessing facility as an example, but the concept can be extended to other facilities. While much of the recent work in the MPACT program has focused on electrochemical safeguards and security technologies, the laboratory capabilities have been applied to other facilities in the past (including aqueous reprocessing, fuel fabrication, and molten salt reactors as examples). This paper provides an overview of the Virtual Test Bed concept, a description of the design process, and a baseline safeguards and security design for the example facility. Parallel papers in this issue go into more detail on the various technologies, experimental testing, modeling capabilities, and performance testing.
Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).
The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.
The MFF series of metallic fuel (U-10wt%Zr) tests performed in the Fast Fuel Test Facility (FFTF) were the beginning tests to qualify the fuel as a driver fuel for FFTF. They all performed very well, to relatively high burnup and with no pin breaches. Tests MFF-3 and MFF-5 were chosen to be destructively examined because they were run at high peak cladding temperatures, 643 and 649°C respectively, and to modest to high burnup (138 and 101 MWd/kgM respectively). They were the only sodium fast reactor (SFR) metallic tests, with long (91.4 cm) fuel columns and clad in HT9, to be operated at these high temperatures. Extensive operating condition reconstruction was performed to accompany the examination, providing detailed operating conditions axially along the pins. In addition, detailed ORIGEN calculations provided fuel burnup along the pin length. These calculations and detailed cross-section metallography allowed a PhD dissertation to be performed where the fuel/cladding chemical interaction (FCCI) was modeled using Fickian and Soret Effect driven diffusion of rare earth fission products to the cladding surface and interact with the cladding. The examination of the MFF-3 and MFF-5 pins included neutron radiography, axial profilometry including pin bow and length measurements, precision gamma scanning, plenum gas puncturing to measure fission gas release, detailed chemical/isotopic analyses of fuel samples to confirm burnup calculations, and metallography of pin cross-sections, including micro-hardness measurements of fuel and cladding.
To pursue technology developments for future launch vehicles, NASA/Marshall Space Flight Center (MSFC) is examining vortex chamber concepts for liquid rocket engine applications. Past studies indicated that the vortex chamber schemes potentially have a number of advantages over conventional chamber methods. Due to the nature of the vortex flow, relatively cooler propellant streams tend to flow along the chamber wall. Hence, the thruster chamber can be operated without the need of any cooling techniques. This vortex flow also creates strong turbulence, which promotes the propellant mixing process. Consequently, the subject chamber concepts not only offer system simplicity, but also enhance the combustion performance. Test results have shown that chamber performance is markedly high even at a low chamber length-to-diameter ratio (LD). This incentive can be translated to a convenience in the thrust chamber packaging. Variations of the vortex chamber concepts have been introduced in the past few decades. These investigations include an ongoing work at Orbital Technologies Corporation (ORBITEC). By injecting the oxidizer tangentially at the chamber convergence and fuel axially at the chamber head end, Knuth et al. were able to keep the wall relatively cold. A recent investigation of the low L/D vortex chamber concept for gel propellants was conducted by Michaels. He used both triplet (two oxidizer orifices and one fuel orifice) and unlike impinging schemes to inject propellants tangentially along the chamber wall. Michaels called the subject injection scheme an Impinging Stream Vortex Chamber (ISVC). His preliminary tests showed that high performance, with an Isp efficiency of 9295, can be obtained. MSFC and the U. S. Army are jointly investigating an application of the ISVC concept for the cryogenic oxygen/hydrocarbon propellant system. This vortex chamber concept is currently tested with gel propellants at AMCOM at Redstone Arsenal, Alabama. A version of this concept for the liquid oxygen (LOX) hydrocarbon fuel (RP-1) system has been derived from the one for the gel propellant. An unlike impinging injector was employed to deliver the propellants to the chamber. MSFC is also conducting an alternative injection scheme, called the chasing injector, associated with this vortex chamber concept. In this injection technique, both propellant jets and their impingement point are in the same chamber cross-sectional plane. Long duration tests (approximately up to 15 seconds) will be conducted on the ISVC to study the thermal effects. This paper will report the progress of the subject efforts at NASA Marshall Space Flight Center. Thrust chamber performance and thermal wall compatibility will be evaluated. The chamber pressures, wall temperatures, and thrust will be measured as appropriate. The test data will be used to validate CFD models, which, in turn, will be used to design the optimum vortex chambers. Measurements in the previous tests showed that the chamber pressures vary significantly with radius. This is due to the existence of the vortices in the chamber flow field. Hence, the combustion efficiency may not be easily determined from chamber pressure. For this project, measured thrust data will be collected. The performance comparison will be in terms of specific impulse efficiencies. In addition to the thrust measurements, several pressure and temperature readings at various locations on the chamber head faceplate and the chamber wall will be made. The first injector and chamber were designed and fabricated based on the available data and experience gained during gel propellant system tests by the U.S. Army. The alternate injector for the ISVC was also fabricated. Hot-fire tests of the vortex chamber are about to start and are expected to complete in February of 2003 at the TS115 facility of MSFC.
Damage tolerance testing development was required to help qualify a new spin forming dome fabrication process for the Ares 1 program at Marshall Space Flight Center (MSFC). One challenge of the testing was due to the compound curvature of the dome. The testing was developed on a sub-scale dome with a diameter of approximately 40 inches. The simulated service testing performed was based on the EQTP1102 Rev L 2195 Aluminum Lot Acceptance Simulated Service Test and Analysis Procedure generated by Lockheed Martin for the Space Shuttle External Fuel Tank. This testing is performed on a specimen with an induced flaw of elliptical shape generated by Electrical Discharge Machining (EDM) and subsequent fatigue cycling for crack propagation to a predetermined length and depth. The specimen is then loaded in tension at a constant rate of displacement at room temperature until fracture occurs while recording load and strain. An identical specimen with a similar flaw is then proof tested at room temperature to imminent failure based on the critical offset strain achieved by the previous fracture test. If the specimen survives the proof, it is then subjected to cryogenic cycling with loads that are a percentage of the proof load performed at room temperature. If all cryogenic cycles are successful, the specimen is loaded in tension to failure at the end of the test. This standard was generated for flat plate, so a method of translating this to a specimen of compound curvature was required. This was accomplished by fabricating a fixture that maintained the curvature of the specimen rigidly with the exception of approximately one-half inch in the center of the specimen containing the induced flaw. This in conjunction with placing the center of the specimen in the center of the load train allowed for successful testing with a minimal amount of bending introduced into the system. Stress corrosion cracking (SCC) tests were performed using the typical double beam assembly and with 4-point loaded specimens under alternate immersion conditions in a 3.5% NaCl environment for 90 days. In addition, experiments were conducted to determine the threshold stress intensity factor for SCC (K1SCC) of Al-Li 2195 which to our knowledge has not been determined previously. The successful simulated service and stress corrosion testing helped to provide confidence to continue to Ares 1 scale dome fabrication.
A test campaign was performed to build an SRM-insulation-material thermal-performance database using MSFC’s Solid Fuel Torch that could be leveraged to enhance understanding of the relationship between ablation rates and internal-environment parameters and improve insulation performance predictions. Seven hot-fire tests were performed along with data analysis that revealed the thermal performance differences among the tested materials. Functional Data Analysis was employed to create a model of material ablation rate as a function of six covariates. The relative importance of several environmental parameters was indicated, and the gaps in the operational space covered by the database were identified.
After approximately 50 years, NASA is restarting efforts to develop nuclear thermal propulsion (NTP) for interplanetary missions. Building upon nuclear engine tests performed from the late 1950s to the early 1970s, the present research and testing focuses on advanced materials and fabrication methods. A number of transient tests have been performed to evaluate materials performance under high-temperature, high-flux conditions, with several more experiments in the pipeline for future testing. The measured data obtained from those tests are being used to validate the Griffin reactor multiphysics code for this particular type of application. Griffin was developed at Idaho National Laboratory (INL) using the MOOSE framework. This article describes the simulation results of the SIRIUS-CAL calibration experiment in the Transient Reactor Test Facility (TREAT). SIRIUS-CAL was the first transient test conducted on NASA fuels, and although the test was performed with a relatively low core peak power, the test specimen survived a temperature exceeding 900 K. Griffin simulations of the experiment successfully matched the reactor’s power transient after calibrating the initial control rod position to match the initial reactor period. The thermal-hydraulics model largely matches the time-dependent response of a thermocouple located within the experiment specimen to within the uncertainty estimate. However, the uncertainty range is significant and must be reduced in the future.
Onto Technology carries out advanced Li-ion battery recycling for industry and. has the only patented technology to produce manufacturing quality electrode materials from recycled batteries. The technology can resolve ongoing cost problems for the industry in life-cycle and conservation of critical materials. Under the Cal TestBed program, Onto Technology teamed with principal investigators at Lawrence Berkeley National Laboratory, who performed tests to evaluate the electrochemical performance of refurbished electrode materials. Other tests to determine structure and morphology of the refurbished materials carried out at LBNL included X-ray diffraction (XRD) and scanning electron microscopy (SEM).