Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Quantification of Coexisting Inner- and Outer-Sphere Complexation of Sulfate on Hematite Surfaces

Sulfate adsorption on hematite surfaces controls sulfate mobility and environmental behavior but whether sulfate forms both inner- and outer-sphere complexes and the type of the inner-sphere complexes remain contentious. With ionic strength tests and S K-edge X-ray absorption near-edge structure spectroscopy, we show that sulfate forms both outer- and inner-sphere complexes on hematite surfaces. Both S K-edge extended X-ray absorption fine structure spectroscopy and the differential pair distribution function analyses determine the S–Fe interatomic distance (~3.24 Å) of the inner-sphere complex, suggesting bidentate-binuclear complexation. A multivariate curve resolution (MCR) analysis of the attenuated total reflection–Fourier-transform infrared spectra of adsorption envelope samples shows that increasing ionic strength does not affect the inner-sphere but decreases the outer-sphere complex adsorption loading, consistent with the ionic strength effect. The extended triple layer model directly and successfully models the MCR-derived inner- and outer-sphere surface loadings at various ionic strengths, indicating weaker sulfate inner-sphere complexation on hematite than on ferrihydrite surfaces. Results also show that sample drying, lower pH, and higher ionic strength all favor sulfate inner-sphere complexation, but the hematite particle size does not affect the relative proportions of the two types of complexes. Sulfate adsorption kinetics show increasing ratio of exchanged OH– to adsorbed sulfate with time, attributed to inner- and outer-sphere complexation dominating at different adsorption stages and to the changes of the relative abundance of surface OH – and H 2 O groups with time. This work clarifies sulfate adsorption mechanisms on hematite and has implications for understanding sulfate availability, behavior and fate in the environment. Our work suggests that the simple macroscopic ionic strength test correlates well with directly measured outer-sphere complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopically Selective Quantification by UPLC-MS of Aqueous Ammonia at Submicromolar Concentrations Using Dansyl Chloride Derivatization

Ammonia (NH 3 ) is necessary for food production and is commercially synthesized from nitrogen (N 2 ) and hydrogen (H 2 ) using the Haber–Bosch process. Significant amounts of ammonia are made every year in a reaction that requires high temperatures and pressures, with the Haber–Bosch accounting for ~1.6% of total annual global energy consumption. Electrocatalysts are also being explored to convert in an environmentally friendly manner N 2 to NH 3 at ambient temperature and pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Inactive Lithium and Solid–Electrolyte Interphase Species on Graphite Electrodes after Fast Charging

Rapid charging of Li-ion batteries is limited by lithium plating on graphite anodes, whereby Li+ ions are reduced to Li metal on the graphite particle surface instead of inserting between graphitic layers, which directly contributes to cell capacity loss because of the low reversibility of the Li plating/stripping process. Furthermore, precisely identifying the onset and amount of Li plating is therefore vital in order to remedy these issues. We demonstrate a titration technique with a detection limit of 20 nmol (5 × 10 –4 mAh) of Li that can be used to quantify inactive Li that remains on the graphite electrode after fast charging. The titration is extended to quantify the total amount of solid carbonate species and lithium acetylide (Li 2 C 2 ) within the solid–electrolyte interphase (SEI), and electrochemical modeling is used to determine the Li plating exchange current density (10 A/m 2 ) and stripping efficiency (65%) of plated Li metal on graphite. These techniques provide a highly accurate measure of the onset of Li plating and quantitative insight into graphite SEI evolution during fast charging.

25 ENERGY STORAGE↗

3D Quantification of Elemental Gradients within Heterostructured Particles of Battery Cathodes

Heterogenous architectures with elemental gradients tailored within particles have been pursued to combat the instabilities limiting Ni-rich cathode materials for lithium-ion batteries. The growth of different compositional layers is accomplished during the synthesis of hydroxide precursors. However, the extent to which these concentration gradients are modified during high-temperature reactions is difficult to establish in their intact, spherical form. Here, we show the entire three-dimensional structure of a secondary particle can be resolved nondestructively with differential X-ray absorption spectroscopy (XAS) through transmission X-ray microscopy (TXM). The relationship between particle location and elemental content was fully quantified, with high statistical significance, for heterostructures possessing different compositional gradients in the precursors with 90:5:5 Ni:Mn:Co core compositions. Reduced elemental heterogeneity was observed after high-temperature synthesis, but gradients remained. In conclusion, the methodology presented should be used to guide synthesis while assuring that gains in electrochemical performance are linked to precise elemental distributions at the nanoscale.

25 ENERGY STORAGE↗

Near-Real-Time Material Tracking: Combining Vis–NIR Spectroscopy with Flow Sensing for Accurate Nd(III) Quantification

A fiber-optic visible–near-infrared (vis–NIR) absorption spectroscopy and flow sensor system has been developed for near-real-time tracking of Nd mass in the effluent stream from a column in a fume hood. The approach leverages two unique data streams and a partial least-squares regression (PLSR) model trained on vis–NIR absorption spectra of Nd(III) (0–1.5 M) in 1 M HNO 3 . In-line volumetric flow rate and vis–NIR spectra are measured in sequence after a chromatography column. The time stamps from each data stream are then synchronized, which allows integrated volumes to be combined with Nd(III) molarities predicted by a PLSR model to accurately calculate the Nd mass flowing through the column. This integrated measurement provides instantaneous mass flow and accumulates these data over time to obtain the total mass processed. The methodology developed in this study contributes critical technical infrastructure to improve monitoring capabilities to support chemical separations and the production of strategic materials and isotopes.

Irvine, Sawyer B. [Oak Ridge National Laboratory (↗

Hybrid Metasurface-Based Mid-Infrared Biosensor for Simultaneous Quantification and Identification of Monolayer Protein

Metasurfaces emerge as a promising photonic platform for biosensing because they offer strong optical confinement and tunable optical resonances. Here, we show that metasurface-based biosensors consisting of gold nanoantenna arrays loaded with graphene and working in the mid-infrared (mid-IR) spectral range can achieve simultaneous high-sensitivity and high-specificity detection of biomolecules. Strong light–molecule interactions in deeply subwavelength optical spots created by the biosensors allow us to determine the concentration of protein molecules via spectral shifts of the metasurface resonance. A combination of passive and active tuning of the metasurface sensors allows us to spectrally overlap the metasurface resonance and the protein vibrational modes, so that protein molecules can be identified via their characteristic mid-IR “fingerprints”. As a result, the high sensitivity and specificity of the metasurface sensors enable us to determine the secondary structure of protein immunoglobulin (IgG) molecules 4 orders of magnitude more sensitive than attenuated total reflection Fourier transform infrared spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗