Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

CERN’s Linac4 H{sup −} sources: Status and operational results

Two volume sources equipped with DESY and CERN plasma generators and a low voltage electron dump were operated at 45 kV in the Linac4 tunnel and on a dedicated test stand. These volume sources delivered approximately 20 mA and ensured the commissioning of the Radio Frequency Quadrupole accelerator and of the first section of the Drift Tube Linac. CERN’s prototype of a cesiated surface source equipped with this electron dump was operated continuously from November 2013 to April 2014 on the ion source test stand and is being commissioned in the Linac4 tunnel. Before cesiation, the prototype conditioned in volume mode provided up to 30 mA H{sup −} beam. Short cesiations, of the order of 10 mg effectively reduced the intensity of co-extracted electrons down to 2 - 8 times the H{sup −} current; this cesiated surface operation mode delivered up to 60 mA H{sup −} beam. An H{sup −} beam of the order of 40 mA was sustained up to four weeks operation with 500 μs pulses at 1.2s spacing. A new extraction was designed to match these beam properties. A copy of BNL’s magnetron produced at CERN was tested at BNL and delivered at 40 kV H{sup −} beam exceeding Linac4’s nominal intensity of 80 mA. In this contribution, the performances, dynamic response to cesiation, stability and availability of these prototypes are described. The needed optimization of the emittance of H{sup −} beam above 40 mA is presented, which requires an evolution of the front end that encompasses implementation of a large ceramic insulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linear and Nonlinear Optical Properties of Metal Nanocomposite Materials

The scientific theme of this award stated in its title is “Linear and Nonlinear Optical Properties of Metal Nanoparticle Composites.” The motivation for the proposal was based on prior work that highlighted unusual third-order nonlinear optical response of metal-nanoparticle composites created by Vanderbilt researchers at the Oak Ridge National Laboratory (ORNL) by implanting metal ions into fused-silica and sapphire substrates and annealing them under appropriate conditions to produce a solid solution comprising noble-metal nanoparticles embedded in an insulating matrix. For example, the well-known localized surface plasmon resonance (LSPR) of gold and silver nanoclusters and nanoparticles was known to yield enhanced effects on the nonlinear absorption and nonlinear refractive index of these materials. The project soon expanded to embrace a wider range of materials and nanostructures, including particularly vanadium dioxide with its insulator-to-metal transition, a wide variety of substrate hosts, and zinc oxide with its multi-faceted band-edge exciton that can be coupled to plasmonic degrees of freedom in silver and aluminum. We employed second- and third-order nonlinear optical spectroscopies and confocal microscopy to quantify the coupling between nanoparticles and adsorbates across interfaces. Because ORNL closed the ion-beam surface-modification facility in 2004, we then developed a nanofabrication technique combining focused ion-beam lithography and pulsed laser deposition to create ordered arrays of metal and oxide nanoparticles in various planar geometries and heterostructures. By 2008, aided by finite-difference time-domain and finite-element calculations, we began to design and fabricate plasmonic “workbenches” on which we could excite quasiparticles (e.g., excitons, phonons, plasmons) using optical signals and electrical impulses, and map the material response down to femtosecond time and nanometer length scales. We developed additional nanofabrication capabilities (e.g., dual-layer electron-beam lithography, quantum-well fabrication and multilayer magnetron sputtering and electron-beam deposition) to create a variety of novel heterostructures as model nanocomposite systems. This led to several new opportunities to study the optical properties of these composites informed by views of potential device configurations. Among the scientific themes that emerged in published papers based on new materials and nanostructures were the following: ultrafast electron dynamics in metamaterials, including ultrafast THz microscopy of the insulator-to-metal transition in VO 2 nanoparticles; plasmon-driven electron injection to promote phase transitions in VO 2 ; and second-harmonic generation in nanostructures without inversion symmetry, in particular, the Archimedean spiral with overall sub-wavelength dimensions. We also explored dimensional and structural effects in plasmonic coupling, including exciton-plasmon coupling in ZnO nanowires; exciton-plasmon coupling in structures incorporating two-dimensional dichalcogenides; and tunable plasmon-induced transparency in plasmonic heterostructures incorporating phase-changing VO 2 . Finally, it should be noted that the work on Archimedean nanospirals and plasmon-exciton coupling led directly into a current quantum-optics research project on photon correlations in diamond nanoparticles, exemplified by the first publication from that effort [Ref. [47] in the bibliography]. A more detailed account setting in the appropriate scientific context all forty-eight papers supported by this award follows.

36 MATERIALS SCIENCE↗

200-BP-1 Prototype Hanford Barrier -- 15 Years of Performance Monitoring

Monitoring is an essential component of engineered barrier system design and operation. A composite capacitive cover, including a capillary break and an evapotranspiration (ET) barrier at the Hanford Site, is generating data that can be used to help resolve these issues. The prototype Hanford barrier was constructed over the 216-B-57 Crib in 1994 to evaluate surface-barrier constructability, construction costs, and physical and hydrologic performance at the field scale. The barrier has been routinely monitored between November 1994 and September 1998 as part of a Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) treatability test of barrier performance for the 200 BP 1 Operable Unit. Since FY 1998, monitoring has focused on a more limited set of key water balance, stability, and biotic parameters. In FY 2009, data collection was focused on: (1) water-balance monitoring, consisting of precipitation, runoff, soil moisture storage, and drainage measurements with evapotranspiration calculated by difference; (2) stability monitoring, consisting of asphalt-layer-settlement, basalt-side-slope-stability, and surface-elevation measurements; (3) vegetation dynamics; and (4) animal use. September 2009 marked 15 years since the start of monitoring and the collection of performance data. This report describes the results of monitoring activities during the period October 1, 2008, through September 30, 2009, and summarizes the 15 years of performance data collected from September 1994 through September 2009.

54 ENVIRONMENTAL SCIENCES↗

Mesoporous Thin Film Architectures: Addressing Material Demands through Molecular Self-Assembly

Mesoporous thin films spark interest across a wide range of disciplines due to their tunable nanostructures, large internal surface areas, and strong compatibility with planar optical, electronic, and microfluidic devices. While attention in the porous materials community has shifted toward macroporous or disordered nanoporous systems, a resurgence in mesoporous thin film research is underway, driven by new molecular self-assembly methods, advanced materials chemistry, and improved characterization techniques. The integration of high-χN block copolymer design, kinetically persistent micelle templating, and postdeposition processing protocols now allows control over structural parameters such as pore size, wall thickness, porosity, and connectivity. These advances have overcome many of the thermodynamic and processing constraints that previously limited widespread adoption. Rather than serving only as high-surface-area supports, mesoporous thin films are engineered as active interfaces where responsive chemistries and nanoscale confinement act in tandem. Embedding switchable ligands, thermoresponsive polymers, redox mediators, or ion-selective groups directly within the pore walls enables real-time control over transport, optical, and electrochemical properties. These capabilities open up new directions in adaptive coatings, gated membranes, and fast-response biosensors. To further expand their functional scope, mesoporous films are integrated into hierarchical and multicomponent architectures. Techniques such as triblock terpolymer templating, crack-directed assembly, and nanoimprint lithography allow for control over spatial organization on the micron and submicron scale and pore system orientation. This enables programmable anisotropy, enhanced molecular diffusion, and wavelength-selective photonic behavior, essential for next-generation sensing, catalysis, and energy applications. Such structural and functional complexity requires equally sophisticated characterization. Multimodal and in situ techniques can track material dynamics under operational conditions. Recent progress includes extended-range ellipsometric porosimetry (EP) for hierarchical architectures, vacuum EP for interface energetics, time-resolved EP for diffusion kinetics, and correlative AFM-SAXS mapping. The introduction of advanced neutron-based spectroscopies, particularly quasielastic neutron scattering (QENS), promises to provide real-time access to ion transport dynamics and segmental motion under nanoscale confinement, offering a path toward deeper mechanistic understanding of structure-performance correlations in mesoporous systems. This Account reflects the technical advances made and the interdisciplinary collaborations that have shaped our collective vision. The particular dimensions of mesopores enable us to subtly tune interactions at the molecular, interfacial, and mesoscopic levels that permit us to harness nanoconfinement. What emerges is a versatile, modular platform capable of chemical gating, energy transduction, and sensing with a level of tunability unmatched by other porous materials. We highlight critical challenges including the need for more robust large-area processing, a deeper understanding of dynamic behavior under cycling, and better integration with device-level architectures. Our strategies support the transition of mesoporous thin films into active high-performance components in next-generation energy, environmental, and biomedical systems.

oxides↗

Elevated gold ellipse nanoantenna dimers as sensitive and tunable surface enhanced Raman spectroscopy substrates

Here we demonstrate large area arrays of elevated gold ellipse dimers with precisely controlled gaps for use as sensitive and highly controllable surface enhanced Raman scattering (SERS) substrates. The significantly enhanced Raman signal observed with SERS arises from both localized and long range plasmonic effects. By controlling the geometry of a SERS substrate, in this case the size and aspect ratio of individual ellipses, the plasmon resonance can be tuned in a broad wavelength range, providing a method for designing the response of SERS substrates at different excitation wavelengths. Plasmon effects exhibited by the elevated gold ellipse dimer substrates are also demonstrated and confirmed through finite difference time domain (FDTD) simulations. A plasmon resonance red shift with an increase of the ellipse aspect ratio is observed, allowing systematic control of the resulting SERS signal intensity. Optimized elevated ellipse dimer substrates with 10±2 nm gaps exhibit uniform SERS enhancement factors on the order of 10 9 for adsorbed p-mercaptoaniline molecules.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Calculated performance of a Wolter type I X-ray telescope coated by multilayers

Deposition of multilayered diffraction coatings on the reflecting surfaces of a Wolter type I X-ray telescope offers the potential of using Bragg reflection to achieve enhanced effective area in selected high energy bandpasses. The structure of a gold-carbon multilayer has been optimized for study of 1.8 A iron-line emission with an X-ray telescope designed for observations from Spacelab. The response of this mirror assembly has been calculated as a function of X-ray energy and the resulting effective area is enhanced by a factor of 10 and peaks at 160 sq cm with a bandpass of 0.4 keV FWHM. This enhanced response is sufficient to allow study of the angular distribution of iron-line emission from the 20 brightest cluster X-ray sources during a 7 day Spacelab mission. The possibility of achieving X-ray imaging in narrow bandpasses at even higher energies has been investigated. It is concluded that it should be possible to achieve effective areas of approximately 5 sq cm in bandpasses approximately 1 keV wide for energies in the 15-25 keV range, a spectral region of much importance during the impulsive phase of solar flares.

Catura, R. C.↗

Heavily doped polysilicon-contact solar cells

The first use of a (silicon)/heavily doped polysilicon)/(metal) structure to replace the conventional high-low junction or back-surface-field (BSF) structure of silicon solar cells is reported. Compared with BSF and back-ohmic-contact (BOC) control samples, the polysilicon-back solar cells show improvements in red spectral response (RSR) and open-circuit voltage. Measurement reveals that a decrease in effective surface recombination velocity S is responsible for this improvement. Decreased S results for n-type (Si:As) polysilicon, consistent with past findings for bipolar transistors, and for p-type (Si:B) polysilicon, reported here for the first time. Though the present polysilicon-back solar cells are far from optimal, the results suggest a new class of designs for high efficiency silicon solar cells. Detailed technical reasons are advanced to support this view.

Lindholm, F. A.↗

Front and back polysilicon-contacted silicon solar cells

The first use of a (silicon)/ (heavily doped polysilicon)/ (metal) structure to replace the conventional high-low junction (or back-surface-field, BSF) structure of silicon solar cells is reported. Compared with BSF and back-ohmic-contact control samples, the polysilicon-back solar cells show improvements in red spectral response and open-circuit voltage. Measurement reveals that a decrease in effective surface recombination velocity S is responsible for this improvement. Decreased S results for n-type (Si:As) polysilicon, consistent with past findings for bipolar transistors, and for p-type (Si:B) polysilicon, reported here for the first time. Though the present polysilicon-back solar cells are far from optimal, the results suggest a new class of designs for high efficiency silicon solar cells. Detailed technical reasons are advanced to support this view.

Lindholm, F. A.↗

Unsteady pressure and structural response measurements of an elastic supercritical wing

Results are presented which define unsteady flow conditions associated with high dynamic response experienced on a high aspect ratio elastic supercritical wing at transonic test conditions while being tested in the NASA Langley Transonic Dynamics Tunnel. The supercritical wing, designed for a cruise Mach number of 0.80, experienced the high dynamic response in the Mach number range from 0.90 to 0.94 with the maximum response occurring at a Mach number of approximately 0.92. At the maximum wing response condition the forcing function appears to be the oscillatory chordwise movement of strong shocks located on both the wing upper and lower surfaces in conjunction with the flow separating and reattaching in the trailing edge region.

Eckstrom, Clinton V.↗

Unsteady pressure and structural response measurements on an elastic supercritical wing

Results are presented which define unsteady flow conditions associated with high dynamic response experienced on a high aspect ratio elastic supercritical wing at transonic test conditions while being tested in the NASA Langley Transonic Dynamics Tunnel. The supercritical wing, designed for a cruise Mach number of 0.80, experienced the high dynamic response in the Mach number range from 0.90 to 0.94 with the maximum response occurring at a Mach number of approximately 0.92. At the maximum wing response condition the forcing function appears to be the oscillatory chordwise movement of strong shocks located on both the wing upper and lower surfaces in conjuction with the flow separating and reattaching in the trailing edge region.

Eckstrom, Clinton V.↗

Development of Curved-Plate Elements for the Exact Buckling Analysis of Composite Plate Assemblies Including Transverse-Shear Effects

The analytical formulation of curved-plate non-linear equilibrium equations including transverse-shear-deformation effects is presented. The formulation uses the principle of virtual work. A unified set of non-linear strains that contains terms from both physical and tensorial strain measures is used. Linearized, perturbed equilibrium equations (stability equations) that describe the response of the plate just after buckling occurs are then derived after the application of several simplifying assumptions. These equations are then modified to allow the reference surface of the plate to be located at a distance z(sub c) from the centroidal surface. The implementation of the new theory into the VICONOPT exact buckling and vibration analysis and optimum design computer program is described as well. The terms of the plate stiffness matrix using both Classical Plate Theory (CPT) and first-order Shear-Deformation Plate Theory (SDPT) are presented. The necessary steps to include the effects of in-plane transverse and in-plane shear loads in the in-plane stability equations are also outlined. Numerical results are presented using the newly implemented capability. Comparisons of results for several example problems with different loading states are made. Comparisons of analyses using both physical and tensorial strain measures as well as CPT and SDPF are also made. Results comparing the computational effort required by the new analysis to that of the analysis currently in the VICONOPT program are presented. The effects of including terms related to in-plane transverse and in-plane shear loadings in the in-plane stability equations are also examined. Finally, results of a design-optimization study of two different cylindrical shells subject to uniform axial compression are presented.

McGowan, David Michael↗

Applications of Meteorological Tower Data at Kennedy Space Center

Members of the National Aeronautics and Space Administration (NASA) design and operation communities rely on meteorological information collected at Kennedy Space Center (KSC), located near Cape Canaveral, Florida, to correctly apply the ambient environment to various tasks. The Natural Environments Branch/EV44, located at Marshall Space Flight Center (MSFC) in Huntsville, Alabama, is responsible for providing its NASA customers with meteorological data using various climatological data sources including balloons, surface stations, aircraft, hindcast models, and meteorological towers. Of the many resources available within the KSC region, meteorological towers are preferred for near-surface applications because they record data at regular, frequent intervals over an extensive period of record at a single location. This paper discusses the uses of data measured at several different meteorological towers for a common period of record and how the data can be applied to various engineering decisions for the new Constellation Program Ares and Orion space vehicles.

Altino, Karen M.↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

Magnetodielectric Response from Spin-Orbital Interaction Occurring at Interface of Ferromagnetic Co and Organometal Halide Perovskite Layers via Rashba Effect

The spin on a ferromagnetic Co surface can interact with the asymmetric orbital on an organometal halide perovskite surface, leading to an anisotropic magnetodielectric effect. Here, this study presents an opportunity to integrate ferromagnetic and semiconducting properties through the Rasbha effect for achieving spin–dependent electronic functionalities based on thin–film design.

36 MATERIALS SCIENCE↗

Array detector for high energy laser based on diffuse transmission sampling

In order to improve the ability and accuracy of measuring the temporal–spatial distribution of the intensity of a large-size, high-energy laser beam, a novel array detecting method based on diffuse transmission sampling is proposed. The measurement principle and the design of the sampling and attenuating unit are presented. High-temperature-resistant diffuse transmission material is used to sample and attenuate a high energy laser beam. Pure copper, whose surface is first sand-blasted and then gold-plated, is applied to scatter the incident high-energy laser beam. The formula for the attenuation ratio was derived in detail. We developed two large-aperture array detectors with spatial resolution of 5 mm, spatial duty ratio of 20%, and useable angle range of ±30° without varying the responsivity, the non-uniformity in the laser profile measurement is below 1%, and the repeatability error in the laser power measurement is approximately 1%. The maximal energy density that the array detector can endure is more than 10 kJ/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non destructive technique for cracks detection by an eddy current in differential mode for steel frames

In this paper, a nondestructive technique is used as a tool to control cracks and microcracks in materials. A simulation by a numerical approach such as the finite element method is employed to detect cracks and eventually; to study their propagation using a crucial parameter such as the stress intensity factor. This approach has been used in the aircraft industry to control cracks. Besides, it makes it possible to highlight the defects of parts while preserving the integrity of the controlled products. On the other side, it is proven that the reliability of the control of defects gives convincing results for the improvement of the quality and the safety of the material. Eddy current testing (ECT) is a standard technique in industry for the detection of surface breaking flaws in magnetic materials such as steels. In this context, simulation tools can be used to improve the understanding of experimental signals, optimize the design of sensors or evaluate the performance of ECT procedures. CEA-LIST has developed for many years semi-analytical models embedded into the simulation platform CIVA dedicated to non-destructive testing. The developments presented herein address the case of flaws located inside a planar and magnetic medium. Simulation results are obtained through the application of the Volume Integral Method (VIM). When considering the ECT of a single flaw, a system of two differential equations is derived from Maxwell equations. The numerical resolution of the system is carried out using the classical Galerkin variant of the Method of Moments. Besides, a probe response is calculated by application of the Lorentz reciprocity theorem. Finally, the approach itself as well as comparisons between simulation results and measured data are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques

Skin dose is one of the key issues for clinical dosimetry in radiation therapy. Currently planning computer systems are unable to accurately predict dose in the buildup region, leaving ambiguity as to the dose levels actually received by the patient's skin during radiotherapy. This is one of the prime reasons why in vivo measurements are necessary to estimate the dose in the buildup region. A newly developed metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector designed specifically for dose measurements in rapidly changing dose gradients was introduced for accurate in vivo skin dosimetry. The feasibility of this detector for skin dose measurements was verified in comparison with plane parallel ionization chamber and radiochromic films. The accuracy of a commercial treatment planning system (TPS) in skin dose calculations for intensity-modulated radiation therapy treatment of nasopharyngeal carcinoma was evaluated using MOSFET detectors in an anthropomorphic phantom as well as on the patients. Results show that this newly developed MOSFET detector can provide a minimal but highly reproducible intrinsic buildup of 7 mg cm{sup -2} corresponding to the requirements of personal surface dose equivalent Hp (0.07). The reproducibility of the MOSFET response, in high sensitivity mode, is found to be better than 2% at the phantom surface for the doses normally delivered to the patients. The MOSFET detector agrees well with the Attix chamber and the EBT Gafchromic registered film in terms of surface and buildup region dose measurements, even for oblique incident beams. While the dose difference between MOSFET measurements and TPS calculations is within measurement uncertainty for the depths equal to or greater than 0.5 cm, an overestimation of up to 8.5% was found for the surface dose calculations in the anthropomorphic phantom study. In vivo skin dose measurements reveal that the dose difference between the MOSFET results and the TPS calculations was on average -7.2%, ranging from -4.3% to -9.2%. The newly designed MOSFET detector encapsulated into a thin water protective film has a minimal reproducible intrinsic buildup recommended for skin dosimetry. This feature makes it very suitable for routine IMRT QA and accurate in vivo skin dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Underlying mechanism of structural transformation between GaSb and GaAs response to intense electronic excitation

Ion irradiation of semiconductors has emerged as a promising approach for fabricating self-organized nanosystems with high atomic precision, despite often being accompanied by undesirable phenomena. Exploring the mechanisms underlying structural transformations is crucial for assessing nanostructure array types under complex irradiation environments. By quantitatively calculating the thermodynamically driven processes and analyzing the impact of intrinsic structural parameters, distinct structural transformations in response to intense electronic excitation are systematically investigated in gallium antimonide (GaSb) and gallium arsenide (GaAs) systems. In high-energy regimes, the nanofibers layer of GaSb exhibits intriguing structural discrepancy, characterized by partial nanofibers with coherent boundaries, interspersed nanopores accompanied by antisite defects and Ga precipitates, distinguishing to a series of discontinuous latent tracks that emerged within cylindrical trajectories in GaAs. Furthermore, significant diffusion behaviors of the nanohillocks are discovered in GaAs, with higher average roughness than GaSb, driven by the gradient stress distribution influenced by the free-surface effects. The deposition energy for melting phase formation, Gibbs free energy, and Ga diffusion coefficients contribute to the distinctive structural features, evidencing relatively stable morphological configurations and higher irradiation resistance in GaAs. Consequently, special optoelectronic properties associated with structural discrepancies facilitate the design and optimization of material functionalities by irradiation technologies.

36 MATERIALS SCIENCE↗