Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Photoluminescence of Fe{sub 2}O{sub 3} nanoparticles prepared by laser oxidation of Fe catalysts in carbon nanotubes

Iron oxide nanoparticles have been produced on the top surface of aligned multi-walled carbon nanotubes by CO{sub 2} laser processing. They were characterized to be Fe{sub 2}O{sub 3} nanoparticles by X-ray photoelectron spectroscopy, X-ray diffraction and high resolution scanning electronic microscopy. Absorption bands in the visible region were found to be redshifted compared with the absorption of Fe{sub 2}O{sub 3} nanoparticles prepared by traditional chemical methods. Photoluminescence from these Fe{sub 2}O{sub 3} nanoparticles shows a broad emission band in the near infrared region for both excitations at 514 and 633 nm. Particle size is considered to be responsible for the unique optical properties of the Fe{sub 2}O{sub 3} nanoparticles.

36 MATERIALS SCIENCE↗

Development of A Multi-Spectral Pyrometry Sensor for High-Speed Transient Surface-Temperature Measurements in Combustion-Relevant Harsh Environments

Accurate and high-speed transient surface-temperature measurements of combustion devices including internal combustion (IC) engines, gas turbines, etc., provide validation targets and boundary conditions for computational fluid dynamics models, and are broadly relevant to technology advancements such as performance improvement and emissions reduction. Development and demonstration of a multi-infrared-channel pyrometry-based optical instrument for high-speed surface-temperature measurement is described. The measurement principle is based on multi-spectral radiation thermometry (MRT) and uses surface thermal radiation at four discrete spectral regions and a corresponding emissivity model to obtain surface temperature via non-linear least squares (NLLS) optimization. Rules of thumb for specifying the spectral regions and considerations to avoid interference with common combustion products are developed; the impact of these along with linear and non-linear MRT analysis are assessed as a function of temperature and signal-to-noise ratio. A multi-start method to determine the MRT-solution global optimum is described and demonstrated. The resulting multi-channel transient pyrometry instrument is described along with practical considerations including optical-alignment drift, matching intra-channel transient response, and solution-confidence indicators. The instrument demonstrated excellent >97% accuracy and >99% 2-sigma precision over the 400–800 °C range, with ~20 µs (50 kHz, equivalent to 0.2 cad at 2000 RPM IC-engine operation) transient response in the bench validation.

47 OTHER INSTRUMENTATION↗

Advancing Reactive Tracer Methods for Measurement of Thermal Evolution in Geothermal Reservoirs (Final Report)

The injection of cold fluids into engineered geothermal system (EGS) and conventional geothermal reservoirs may be done to help extract heat from the subsurface or to maintain pressures within the reservoir (e.g., Rose et al., 2001). As these injected fluids move along fractures, they acquire heat from the rock matrix and remove it from the reservoir as they are extracted to the surface. A consequence of such injection is the migration of a cold-fluid front through the reservoir (Figure 1) that could eventually reach the production well and result in the lowering of the temperature of the produced fluids (thermal breakthrough). Efficient operation of an EGS as well as conventional geothermal systems involving cold-fluid injection requires accurate and timely information about thermal depletion of the reservoir in response to operation. In particular, accurate predictions of the time to thermal breakthrough and subsequent rate of thermal drawdown are necessary for reservoir management, design of fracture stimulation and well drilling programs, and forecasting of economic return. A potential method for estimating migration of a cold front between an injection well and a production well is through application of reactive tracer tests, using chemical whose rate of degradation is dependent on the reservoir temperature between the two wells (e.g., Robinson 1985). With repeated tests, the rate of migration of the thermal front can be determined, and the time to thermal breakthrough calculated. While the basic theory behind the concept of thermal tracers has been understood for some time, effective application of the method has yet to be demonstrated. This report describes results of a study that used several methods to investigate application of reactive tracers to monitoring the thermal evolution of a geothermal reservoir. These methods included (1) mathematical investigation of the sensitivity of known and hypothetical reactive tracers, (2) laboratory testing of novel tracers that would improve method sensitivity, (3) development of a software tool for design and interpretation of reactive tracer tests and (4) field testing of the reactive tracer temperature monitoring concept.

15 GEOTHERMAL ENERGY↗

Plasmonic Based Sensing Using an Array of Au-Metal Oxide Thin Films

An optical plasmonic-based sensing array has been developed and tested for the selective and sensitive detection of H2, CO, and NO2 at a temperature of 500°C in an oxygen-containing background. The three element sensing array used Au nanoparticles embedded in separate thin films of yttria stabilized zirconia (YSZ), CeO2, and TiO2. A peak in the absorbance spectrum due to a localized surface plasmon resonance (LSPR) on the Au nanoparticles was monitored for each film during gas exposures and showed a blue shift in the peak positions for the reducing gases, H2 and CO, and a red shift for the oxidizing gas NO2. A more in-depth look at the sensing response was performed using the multivariate methods of principal component analysis (PCA) analysis and linear discriminant analysis (LDA) on data from across the entire absorbance spectrum range. Qualitative results from both methods showed good separation between the three analytes for both the full array and the Au-TiO2 sample. Quantification of LDA cluster separation using the Mahalanobis distance showed better cluster separation for the array, but there were some instances with the lowest concentrations where the single Au-TiO2 film had better separation than the array. A second method to quantify cluster separation in LDA space was developed using multidimensional volume analysis of the individual cluster volume, overlapped cluster volume and empty volume between clusters. Compared to the individual sensing elements, the array showed less cluster overlap, smaller cluster volumes, and more space between clusters, all of which were expected for improved separability between the analytes.

Environmental Molecular Sciences Laboratory↗

A lithium–oxygen battery based on lithium superoxide

Batteries based on sodium superoxide and on potassium superoxide have recently been reported(1-3). But, there have been no reports of a battery based on lithium superoxide (LiO 2 ), despite much research(4-8) into the lithium-oxygen (Li-O 2 ) battery because of its potential high energy density. Several studies(9-16) of Li-O 2 batteries have found evidence of LiO 2 being formed as one component of the discharge product along with lithium peroxide (Li 2 O 2 ). In addition, theoretical calculations have indicated that some forms of LiO 2 may have a long lifetime(17). Our studies also suggest that it might be possible to form LiO 2 alone for use in a battery. However, solid LiO 2 has been difficult to synthesize in pure form(18) because it is thermodynamically unstable with respect to disproportionation, giving Li 2 O 2 (refs 19, 20). We show that crystalline LiO 2 can be stabilized in a Li-O 2 battery by using a suitable graphene-based cathode. Various characterization techniques reveal no evidence for the presence of Li 2 O 2 . A novel templating growth mechanism involving the use of iridium nanoparticles on the cathode surface may be responsible for the growth of crystalline LiO 2 . Our results demonstrate that the LiO 2 formed in the Li-O 2 battery is stable enough for the battery to be repeatedly charged and discharged with a very low charge potential (about 3.2 volts). We also anticipate that this discovery will lead to methods of synthesizing and stabilizing LiO 2 , which could open the way to high-energy-density batteries based on LiO 2 as well as to other possible uses of this compound, such as oxygen storage.

25 ENERGY STORAGE↗

Graphene oxide modified TiO 2 nanotube arrays: enhanced visible light photoelectrochemical properties

Novel nanocomposite films based on graphene oxide (GO) and TiO 2 nanotube arrays were synthesized by assembling GO on the surface of self-organized TiO 2 nanotube arrays through a simple assembling method. The composite films were characterized with field emission scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and UV-vis diffuse reflectance spectroscopy. Photoelectrochemical properties of the composite nanotube arrays were investigated under visible light illumination. Remarkably enhanced visible light photoelectrochemical response was observed for the GO decorated TiO 2 nanotube composite electrode compared with pristine TiO 2 nanotube arrays. Sensitizing effect of GO on the photoelectrochemical response of TiO 2 nanotube arrays was demonstrated and about 15 times enhanced maximum photoconversion efficiency was obtained with the presence of GO. Enhanced photocatalytic activity of TiO 2 nanotube arrays towards degradation of methyl blue was also demonstrated after modification of GO. The results presented here demonstrate GO to be efficient for the improvement of utilization of visible light for TiO 2 nanotube arrays.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Optimization of Design and Manufacturing Process of Metal Foam Filled Anti-Intrusion Bars

The role of an anti-intrusion bar for automotive use is to absorb the kinetic energy of the colliding bodies that is partially converted into internal work of the bodies involved in the crash. The aim of this paper is to investigate the performances of a new kind of anti-intrusion bars for automotive use, filled with metallic foams. The reason for using a cellular material as a filler deals with its capacity to absorb energy during plastic deformation, while being lightweight. The study is the evolution of a previous paper presented by the authors at Esaform 2010 and will present new results and findings. It is conducted by evaluating some key technical issues of the manufacturing problem and by conducting experimental and numerical analyses. The evaluation of materials and shapes of the closed sections to be filled is made in the perspective of a car manufacturer (production costs, weight reduction, space availability in a car door, etc.). Experimentally, foams are produced starting from an industrial aluminium precursor with a TiH{sub 2} blowing agent. Bars are tested in three point bending, in order to evaluate their performances in terms of force-displacement response and other specific performance parameters. In order to understand the role of interface between the inner surface of the tube and the external surface of the foam, different kinds of interface are tested.

36 MATERIALS SCIENCE↗

A simplified analytical solution for thermal response of a one-dimensional, steady state transpiration cooling system in radiative and convective environment

A simplified analytical method for calculation of thermal response within a transpiration-cooled porous heat shield material in an intense radiative-convective heating environment is presented. The essential assumptions of the radiative and convective transfer processes in the heat shield matrix are the two-temperature approximation and the specified radiative-convective heatings of the front surface. Sample calculations for porous silica with CO2 injection are presented for some typical parameters of mass injection rate, porosity, and material thickness. The effect of these parameters on the cooling system is discussed.

Kubota, H.↗

Forward-bias capacitance and current measurements for determining lifetimes and band narrowing in p-n junction solar cells

A new method is described and illustrated for determining the minority-carrier diffusion length and lifetime in the base region of p-n junction solar cells. The method requires only capacitance measurements at the device terminals and its accuracy is estimated to be + or - 5%. It is applied to a set of silicon p-n junction devices and the values of the diffusion lengths agree with those obtained using the current response to X-ray excitation but disagree with those obtained by the OCVD method. The reasons for the relative inaccuracy of OCVD applied to silicon devices are discussed. The capacitance method includes corrections for a two-dimensional fringing effects which occur in small area devices. For a device having highly-doped base region and surface (emitter) layer, the method can be extended to enable the determination of material properties of the degenerately doped surface layer. These material properties include the phenomenological emitter lifetime and a measure of the energy band-gap narrowing in the emitter. An alternate method for determining the energy band-gap narrowing from temperature dependence of emitter current is discussed and demonstrated.

Neugroschel, A.↗

IMS Rapid Response 2024 Summary Report: A Machine Learning Potential for the Periodic Table

Stockpile stewardship and nuclear waste remediation are inherently chemically complex, involving practically the full diversity of the periodic table, but existing methods are too expensive or not functional for a large diversity of atom types. Overall, the field of machine learning interatomic potentials (MLIPs) has advanced dramatically in 2024 with large high-accuracy datasets existing for bulk, surface, and organic chemical systems and new online leaderboards for diverse chemistry. To participate in, and bring LANL interests into this ecosystem, here, we have built upon existing technologies created by LANL to create a framework capable of creating machine learning interatomic potentials (MLIPs) for over 90 atom types. Our results have created a massively diverse coordination complex training dataset more than 3 times the size of existing datasets, parallelized MLIP training over multiple GPUs, enabling the training of an MLIP spanning the periodic table at 20 times the speed of prior training on 32 GPUs. These advances are substantial towards creation on foundational MLIPs for LANL-specific application areas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HyPAM: A hybrid continuum-particle model for incompressible free-surface flows

Three major issues associated with numerical simulations of complex free-surface flows, viz. interface tracking, fragmentation and large physical jumps, are addressed by a new hybrid continuum-particle model (HyPAM). The new model consists of three parts: (1) the Polygonal Area Mapping method [Q. Zhang, P.L.-F. Liu, A new interface tracking method: the polygonal area mapping method, J. Comput. Phys. 227(8) (2008) 4063-4088]; (2) a new algorithm that decomposes the interested (water) phase into a continuum zone, a buffer zone and a particle zone, based on material topology and graph theory; (3) a 'passive-response' assumption, in which the air phase is assumed to respond passively to the continuum part of the water phase. The incompressible inviscid Euler equations and the equations describing the free fall of rigid bodies are used as the governing equations for the continuum-buffer zone and the particle zone, respectively, and separately. A number of examples, including water droplet impact, solitary wave propagation, and dam-break problems, are simulated for the illustration and validation of HyPAM. It is shown that HyPAM is more accurate and versatile than a continuum-based Volume-of-Fluid model. One major contribution of this work is the single-phase decomposition algorithm, useful for many other hybrid formulations. Neglecting surface tension, viscosity and particle interactions, HyPAM is currently limited to mildly-fragmented free-surface flows with high Reynolds and Weber numbers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solvothermal synthesis of graphene-Sb{sub 2}S{sub 3} composite and the degradation activity under visible light

Graphical abstract: Display Omitted Highlights: ► Graphene-Sb{sub 2}S{sub 3} composites were synthesized through a facile solvothermal method. ► Hydroxyl radicals are the main species responsible for the photodegradation activity. ► Graphene-Sb{sub 2}S{sub 3} demonstrated dramatically improved visible light degradation activity. -- Abstract: Novel graphene-Sb{sub 2}S{sub 3} (G-Sb{sub 2}S{sub 3}) composites were synthesized via a facile solvothermal method with graphene oxide (GO), SbCl{sub 3} and thiourea as the reactants. GO played an important role in controlling the size and the distribution of the formed Sb{sub 2}S{sub 3} nanoparticles on the graphene sheets with different density. Due to the negative surface charge, smaller Sb{sub 2}S{sub 3} particles size and efficient electrons transfer from Sb{sub 2}S{sub 3} to graphene, the composites demonstrated improved photodegradation activity on rhodamine B (RhB). Among these composites, the product G-Sb{sub 2}S{sub 3} 0.1, which was synthesized with the GO concentration of 0.1 mg/mL, exhibited the highest photodegradation activity owing to the considerable density of Sb{sub 2}S{sub 3} nanoparticles onto graphene sheet free of aggregation. Hydroxyl radicals (·OH) derived from conduction band (CB) electrons of Sb{sub 2}S{sub 3} is suggested to be responsible for the photodegradation of RhB. The high visible light degradation activity and the satisfactory cycling stability made the as-prepared G-Sb{sub 2}S{sub 3} 0.1 an applicable photocatalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Controlled Storage Conditions on the Hydrolysis and Surface Morphology of Amorphous-UO 3

The hydration and morphological effects of amorphous (A)-UO 3 following storage under varying temperature and relative humidity have been investigated. This study provides valuable insight into U-oxide speciation following aging, the U-oxide quantitative morphological data set, and, overall, the characterization of nuclear material provenance. A-UO 3 was synthesized via the washed uranyl peroxide synthetic route and aged based on a 3-factor circumscribed central composite design of experiment. Target aging times include 2.57, 7.00, 14.0, 21.0, and 25.4 days, temperatures of 5.51, 15.0, 30.0, 45.0, and 54.5 °C, and relative humidities of 14.2, 30.0, 55.0, 80.0, and 95.8% were examined. Following aging, crystallographic changes were quantified via powder X-ray diffraction and an internal standard Rietveld refinement method was used to confirm the hydration of A-UO 3 to crystalline schoepite phases. The particle morphology from scanning electron microscopy images was quantified using both the Morphological Analysis of MAterials software and machine learning. Results from the machine learning were processed via agglomerative hierarchical clustering analysis to distinguish trends in morphological attributes from the aging study. Significantly hydrated samples were found to have a much larger, plate-like morphology in comparison to the unaged controls. Predictive modeling via a response surface methodology determined that while aging time, temperature, and relative humidity all have a quantifiable effect on A-UO 3 crystallographic and morphological changes, relative humidity has the most significant impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Development of coated heat flux gauges for fast responding measurements

Thermal systems often exhibit transient behaviors that have important implications for the operation of the system and can be difficult to predict. For these reasons, experimental testing is often required to ensure system durability requirements are achieved. One important parameter governing the survivability of components in hot, high-stress environments is the heat flux into the part that dictates the temperature distribution for the component. However, sensors required to experimentally characterize heat fluxes in extreme environments must also be resilient. Here, this study presents the development of coated heat transfer gauges capable of robust, high-frequency measurements in turbine research facilities. The addition of a protective coating increases the durability of the gauge, but inherent of that coating is the attenuation of high-frequency temperature penetrations. As a result, this study first outlines the use of analytical solutions to define a gauge design for a specific frequency range and heat transfer, ensuring that subsurface signals can be rectified to surface conditions through inverse methods. Then, the fabrication of polyimide substrate sensors with a parylene-F coating is described. Micro surface heaters added to the custom sensors were used to determine important geometric and thermal properties necessary to calculate accurate surface heat flux. Ultimately, this work shows increased sensor robustness in a turbine test bed and experimentally validates that the frequency response of the fabricated sensors meet the design intent.

47 OTHER INSTRUMENTATION↗

An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22x22 cm{sup 2}, has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10x10 cm{sup 2} field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3x3 cm{sup 2} aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3x3 cm{sup 2} aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Water Sound Synthesis using Coupled Bubbles

We introduce a practical framework for synthesizing bubble-based water sounds that captures the rich inter-bubble coupling effects responsible for low-frequency acoustic emissions from bubble clouds. We propose coupled-bubble oscillator models with regularized singularities, and techniques to reduce the computational cost of time stepping with dense, time-varying mass matrices. Airborne acoustic emissions are estimated using finite-difference time-domain (FDTD) methods. We propose a simple, analytical surface-acceleration model, and a sample-and-hold GPU wavesolver that is simple and faster than prior CPU wavesolvers. Sound synthesis results are demonstrated using bubbly flows from incompressible, two-phase simulations, as well as procedurally generated examples using single-phase FLIP fluid animations. Our results demonstrate sound simulations with hundreds of thousands of bubbles, and perceptually significant frequency transformations with fuller low-frequency content.

Computer Science↗

X-ray testing of grazing incidence optics fabricated at the University of Colorado

An account is given of the methods and results of X-ray testing for the grazing-incidence optics of the F/5.73 Wolter Type I telescope, whose mirror had flown on a NASA sounding rocket in March, 1991. Attention is given to the tests of the inplane (full aperture) and offplane (apodized aperture) imaging response at 0.25-1.50 keV energies; correlations with surface figures are discussed.

Gallagher, Dennis↗