Measurement of dynamic characteristics of soils with penetrometers
Soil response to dynamic loads measured by penetrometers
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Soil response to dynamic loads measured by penetrometers
Computerized simulation of Venus atmospheric entry by earth reentry, and test program on soil response to landing loads
X-15 flight heating simulation accuracy tested and inaccuracy effects on flight load strain gage responses
Communications satellite antenna structure dynamic response to random loads in launch environment
The equations of motion necessary to compute the transient response of multi-mass flexible rotors are formulated to include unbalance, rotor acceleration, and flexible damped nonlinear bearing stations. A method of calculating the unbalance response of flexible rotors from a modified Myklestad-Prohl technique is discussed in connection with the method of solution for the transient response. Several special cases of simplified rotor-bearing systems are presented and analyzed for steady-state response, stability, and transient behavior. These simplified rotor models produce extensive design information necessary to insure stable performance to elastic mounted rotor-bearing systems under varying levels and forms of excitation. The nonlinear journal bearing force expressions derived from the short bearing approximation are utilized in the study of the stability and transient response of the floating bush squeeze damper support system. Both rigid and flexible rotor models are studied, and results indicate that the stability of flexible rotors supported by journal bearings can be greatly improved by the use of squeeze damper supports. Results from linearized stability studies of flexible rotors indicate that a tuned support system can greatly improve the performance of the units from the standpoint of unbalanced response and impact loading. Extensive stability and design charts may be readily produced for given rotor specifications by the computer codes presented in this analysis.
A series of dynamic environmental tests on the Viking 1975 Orbiter/Lander model provided information regarding damping and linearity. The quality of mode isolation was made with orthogonality checks. A pretest criterion established for orthogonality provided good correlation with test results. Part of the post-test analysis was dedicated to a review of instrumentation selection for control and/or response limiting. Limited load values were also examined.
Two aspects of the post-buckling analysis of composite plates are considered in this paper. The first pertains to identifying the different types of symmetry exhibited by the pre- and post-buckling responses of rectangular and skewed composite plates. A procedure is presented for exploiting these symmetries in finite-element and finite-difference analyses. The procedure can be used with existing programs having multipoint constraint capability. The second aspect pertains to the post-buckling response of biaxially loaded composite plates. Numerical results from finite-element analysis are presented which show the range of parameters for which shear deformation and/or anisotropy are important in buckling and post-buckling analysis.
Direct characterization procedures were used to determine the relaxation modulus as a function of time, temperature, and state of strain. Using the quasi-elastic method of linearviscoelasticity, these properties were employed in a finite element computer code to analyze a thick-walled, nonlinear viscoelastic cylinder in the state of plane strain bonded to a thin (but stiff) elastic casing and subjected to slow thermal cooling. The viscoelastic solution is then expressed as a sequence of elastic finite element solutions. The strain-dependent character of the relaxation modulus is included by replacing the single relaxation curve used in the linear viscoelastic theory by a family of relaxation functions obtained at various strain levels. These functions may be regarded as a collection of stress histories or responses to specific loads (in this case, step strains) with which the cooldown solution is made to agree by iterations on the modulus and strain level.
The objective of the test was to assess fire containment and fire extinguishment in the cargo by reducing the ventilation through the cargo compartment. Parameters which were measured included ignition time, burnthrough time, and physical damage to the cargo liner, composition of selected combustible gases, temperature-time histories, heat flux, and detector response. The ignitor load was made of a typical cargo consisting of filled cardboard cartons occupying 50% of the compartment volume.
A procedure for treating creep-fatigue for low strainranges and long hold times is outlined. A semi-experimental approach, wherein several cycles of the imposed loading is actually applied to a specimen in order to determine the stable hysteresis loop, can be very useful in the analysis. Because such tests require only a small fraction of the total failure time, they are not inherently prohibitive if experimental equipment is available. The need for accurate constitutive equations is bypassed because the material itself acts to translate the imposed loading into the responsive hysteresis loops. When strainrange partitioning has been applied in such cases very good results have been obtained.
A viscoelastic stiffness model of seismicity is developed by introducing a viscoelastic element into the stiffness model for fault dynamics. The introduction of this element permits modeling of transient anelastic deformations in response to stress loading and relaxation and provides a mechanism for partial stress recovery following an earthquake. As a consequence, several phenomena not present in elastic stiffness theory emerge. These include postseismic creep, foreshocks, and aftershocks. Numerical simulations of fault motion also reveal episodes of stable sliding, tertiary creep preceeding earthquakes, and long-term aseismic creep.
Three cracked geometries are studied with the aid of a new finite element model. The procedure employs a variable singularity at the crack tip that tracks changes in the material response during the loading process. Two of the problems are tension-loaded center-crack panels and the other is a three-point bend specimen. Results usually agree with other numerical and analytical analyses, except the finding that J is path dependent as a substantial plastic zone develops. Credible J values are obtained near the crack tip and J shows a significant increase as the radius of J path increases over two orders of magnitude. Incremental and deformation theories are identical provided the stresses exhibit proportionality found in the far field stresses but not near the tip.
The method of constructing fields on the basis of EEG data gives a quantitative characterization of bioelectrical activity. Fields of average rates of the change of potentials in healthy people have a well defined configuration, where the greatest rates are found in the occipital zones, lower in the frontal and parietal, and least in the temporal zones. In response to functional loads the form of the field remains the same because of a synchronous change in the average rates in both hemispheres of the cerebrum to the same extent. The configuration of the fields of background bioelectric activity of the cerebrum in people with Meniere's disease is not uniform. On the basis of this investigation, a clear correlation was found between the subjective sensations of patients during oxygen and carbogen therapy and the changes in the spatial characteristics of the field of potentials of the cerebrum. This correlation makes it possible to objectively identify the nature of the vascular disturbances in Meniere's disease, develop a pathogenetic treatment plan, and evaluate its effectiveness.
Three aspects of the test results are compared: rotor blade bending loads, rotor teeter response, and nacelle yaw moments. As a result of the tests, it is shown that while mean flatwise bending moments were unaffected by the placement of the rotor, cyclic flatwise bending tended to increase with wind speed for the downwind rotor while remaining somewhat uniform with wind speed for the upwind rotor, reflecting the effects of increased flow disturbance for a downwind rotor. Rotor teeter response was not significantly affected by the rotor location relative to the tower, but appears to reflect reduced teeter stability near rated wind speed for both configurations. Teeter stability appears to return above wind speed, however. Nacelle yaw moments are higher for the upwind rotor but do not indicate significant design problems for either configuration.
Tests were conducted on a 38m diameter horizontal axis wind turbine, which had first a rotor downwind of the supporting truss tower and then upwind of the tower. Aside from the placement of the rotor and the direction of rotation of the drive train, the wind turbine was identical for both tests. Three aspects of the test results are compared: rotor blade bending loads, rotor teeter response, and nacelle yaw moments. As a result of the tests, it is shown that while mean flatwise bending moments were unaffected by the placement of the rotor, cyclic flatwise bending tended to increase with wind speed for the downwind rotor while remaining somewhat uniform with wind speed for the upwind rotor, reflecting the effects of increased flow disturbance for downwind rotor. Rotor teeter response was not significantly affected by the rotor location relative to the tower, but appears to reflect reduced teeter stability near rated wind speed for both configurations. Teeter stability appears to return above rated wind speed, however. Nacelle yaw moments are higher for the upwind rotor but do not indicate significant design problems for either configuration.
The highlights of the many wind-tunnel tests conducted in the course of the Space Shuttle development program are presented with emphasis on instrumentation applications. The examples of tests discussed include airframe aerodynamics, aerodynamic heating, aerodynamic noise, tile dynamic response, and tile loads. Many of the tests were conducted with standard wind-tunnel instrumentation. Most of the more unusual instrumentation requirements were related to the thermal protection system, where some pressure-sensor concepts were adapted to measure airloads on tiles. These measurements provided the only quantitative data that could be used to confirm the airload analysis procedure. Limited applications of computers to experimental control, in conjunction with data taken during Shuttle tests, have resulted in substantial benefits in overall test efficiency.
The coupled base motion equations of a system composed of a launch vehicle and several payloads are derived. In previous work it was shown how the special form of these equations allow for a quick and accurate solution both for the response and the loads of the system. In this paper a short-cut version of this direct integration technique is presented and evaluated. The result is a method which, depending on the nature of the structure at hand, vasilates between a full-scale coupled base motion approach and an open loop base drive method. Although completely general, the presented technique is most effective when the number of interface degrees of freedom is relatively small compared to the overall number of degrees of freedom of the system. The S.T.S.-S.T.-O.M.S. Kit system is used as an illustrative example.
Recent advances in the art of free piston Stirling engine design make possible the production of 1-10kW free piston Stirling linear alternator engine, hermetically sealed, efficient, durable and simple in construction and operation. Power output is in the form of single or three phase 60 Hz. AC, or DC. The three phase capability is available from single machines without need of external conditioning. Engine voltage control regains set voltage within 5 cycles in response to any load change. The existing SPIKE-2 design has an engine alternator efficiency of 25% at 650 C heater wall temperature and a service life of over three years in solar service. The same system can be scaled over a range of at least 100 watts to 25kW.