Production of a highly charged uranium ion beam with RIKEN superconducting electron cyclotron resonance ion source

A highly charged uranium (U) ion beam is produced from the RIKEN superconducting electron cyclotron resonance ion source using 18 and 28 GHz microwaves. The sputtering method is used to produce this U ion beam. The beam intensity is strongly dependent on the rod position and sputtering voltage. We observe that the emittance of U{sup 35+} for 28 GHz microwaves is almost the same as that for 18 GHz microwaves. It seems that the beam intensity of U ions produced using 28 GHz microwaves is higher than that produced using 18 GHz microwaves at the same Radio Frequency (RF) power.

43 PARTICLE ACCELERATORS↗

Highly ionized physical vapor deposition plasma source working at very low pressure

Highly ionized discharge for physical vapor deposition at very low pressure is presented in the paper. The discharge is generated by electron cyclotron wave resonance (ECWR) which assists with ignition of high power impulse magnetron sputtering (HiPIMS) discharge. The magnetron gun (with Ti target) was built into the single-turn coil RF electrode of the ECWR facility. ECWR assistance provides pre-ionization effect which allows significant reduction of pressure during HiPIMS operation down to p = 0.05 Pa; this is nearly more than an order of magnitude lower than at typical pressure ranges of HiPIMS discharges. We can confirm that nearly all sputtered particles are ionized (only Ti{sup +} and Ti{sup ++} peaks are observed in the mass scan spectra). This corresponds well with high plasma density n{sub e} {approx} 10{sup 18} m{sup -3}, measured during the HiPIMS pulse.

43 PARTICLE ACCELERATORS↗

Sub-MeV ultra-compact linac for radioactive isotope sources replacement, non-destructive testing, security and medical applications

RadiaBeam Technologies, LLC has developed an inexpensive, hand-portable 180 keV electron accelerator to replace 57 Co radionuclide sources in Cascade Header Enrichment Monitor detectors. We used two innovative technologies in our design: a Ku-band (1 cm wavelength) magnetron, and a split accelerating structure design to reduce manufacturing costs. In this paper, we will discuss the accelerator, including X-ray convertor and accelerating structure design. The results of RF measurements of a Ku-band split structure prototype will also be reviewed. Other applications of Ku-band linacs include compact backscatter and transmission X-ray security inspection systems, as well as computed tomography (CT) systems for luggage and parcel screening. The main requirement for luggage inspection systems is that the X-ray source must be extremely compact. Further, the required energies should cover the range from 180 keV to 1 MeV. In this paper, we will discuss the linac’s energy scalability and other modifications that will enable our technology to address these applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗

Wide-frequency range, dynamic matching network and power system for the “Shoelace” radio frequency antenna on the Alcator C-Mod tokamak

A wide-frequency range (50–300 kHz) power system has been implemented for use with a new RF antenna – the “Shoelace” antenna – built to drive coherent plasma fluctuations in the edge of the Alcator C-Mod tokamak. A custom, dynamically tunable matching network allows two commercial 1 kW, 50-Ω RF amplifiers to drive the low-impedance, inductive load presented by the antenna. This is accomplished by a discretely variable L-match network, with 81 independently selected steps available for each of the series and parallel legs of the matching configuration. A compact programmable logic device provides a control system that measures the frequency with better than 1 kHz accuracy and transitions to the correct tuning state in less than 1 ms. At least 85% of source power is dissipated in the antenna across the operational frequency range, with a minimum frequency slew rate of 1 MHz/s; the best performance is achieved in the narrower band from 80 to 150 kHz which is of interest in typical experiments. The RF frequency can be run with open-loop control, following a pre-programmed analog waveform, or phase-locked to track a plasma fluctuation diagnostic signal in real time with programmable phase delay; the amplitude control is always open-loop. The control waveforms and phase delay are programmed remotely. These tools have enabled first-of-a-kind measurements of the tokamak edge plasma system response in the frequency range and at the wave number at which coherent fluctuations regulate heat and particle transport through the plasma boundary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of realistic Monte Carlo plasma gamma-ray source on JET discharges

A novel modelling methodology has been developed for the creation of a realistic plasma gamma-ray source for Monte Carlo transport simulations in the tokamak JET. The methodology couples the TRANSP code for plasma transport calculations with the MCNP Monte Carlo particle transport code, thus connecting plasma physics with gamma-ray transport. Here, we present the validation of the developed source methodology by comparing calculated gamma-ray spectra with measurements performed at JET. The validation focuses on gamma-ray spectra measured by the tangential gamma-ray spectrometer during two JET three ion RF scenario discharges, performed in the JET 2019 deuterium experimental campaign. For validation the calculated plasma gamma-ray spectrum was combined with the neutron induced prompt gamma-ray background, originating in the vacuum vessel, and scaled to absolute values calculating the total number of plasma gamma-ray and neutron emitting reactions. The comparison between calculated and measured gamma-ray spectra shows good agreement with the shape of the calculated gamma-ray spectra matching that of measurements for both studied discharges. Moreover, the calculated absolute values of the gamma-ray spectra were of the same order of magnitude at the position of the gamma-ray detector located at the end of a long line-of-sight in a biological shield. Finally, the comparison has validated the developed plasma gamma-ray source methodology for MCNP photon transport calculations at JET. The validation provides a basis for the developed plasma gamma-ray source to be used as a support for the development of future tokamaks such as DEMO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modified Penning-Malmberg Trap for Storing Antiprotons

A modified Penning-Malmberg trap that could store a small cloud of antiprotons for a relatively long time (weeks) has been developed. This trap is intended for use in research on the feasibility of contemplated future matter/antimatter-annihilation systems as propulsion sources for spacecraft on long missions. This trap is also of interest in its own right as a means of storing and manipulating antiprotons for terrestrial scientific experimentation. The use of Penning-Malmberg traps to store antiprotons is not new. What is new here is the modified trap design, which utilizes state-of-the-art radiofrequency (RF) techniques, including ones that, heretofore, have been used in radio-communication applications but not in iontrap applications. A basic Penning-Malmberg trap includes an evacuated round tube that contains or is surrounded by three or more collinear tube electrodes. A steady axial magnetic field that reaches a maximum at the geometric center of the tube is applied by an external source, and DC bias voltages that give rise to an electrostatic potential that reaches a minimum at the center are applied to the electrodes. The combination of electric and magnetic fields confines the charged particles (ions or electrons) for which it was designed to a prolate spheroidal central region. However, geometric misalignments and the diffusive cooling process prevent the steady fields of a basic Penning- Malmberg trap from confining the particles indefinitely. In the modified Penning-Malmberg trap, the loss of antiprotons is reduced or eliminated by use of a "rotating-wall" RF stabilization scheme that also heats the antiproton cloud to minimize loss by matter/antimatter annihilation. The scheme involves the superposition of a quadrupole electric field that rotates about the cylindrical axis at a suitably chosen radio frequency. The modified Penning-Malmberg trap (see Figure 1) includes several collinear sets of electrodes inside a tubular vacuum chamber. Each set comprises either a single metal tube or else a tube that is segmented into four electrodes that subtend equal angles about the cylindrical axis. The output of an RF signal generator is fed through a 90 hybrid coupler and then through two baluns to generate four replicas of the signal at relative phase shifts of 0 , 90 , 180 , and 270 (see Figure 2). These signal replicas are fed through 6-dB directional couplers, then via coaxial cables to the vacuum chamber. The signal is then routed to a phase cancellation network, which filters out the drive signal with the difference representing the plasma interaction. Inside the vacuum chamber, twisted-pair wires feed the signals from the coaxial cables to the four electrodes of each segmented electrode tube.

Sims, William H.↗

The 30-GHz monolithic receive module

Key requirements for a 30 GHz GaAs monolithic receive module for spaceborne communication antenna feed array applications include an overall receive module noise figure of 5 dB, a 30 dB RF to IF gain with six levels of intermediate gain control, a five-bit phase shifter, and a maximum power consumption of 250 mW. The RF designs for each of the four submodules (low noise amplifier, some gain control, phase shifter, and RF to IF sub-module) are presented. Except for the phase shifter, high frequency, low noise FETs with sub-half micron gate lengths are employed in the submodules. For the gain control, a two stage dual gate FET amplifier is used. The phase shifter is of the passive switched line type and consists of 5-bits. It uses relatively large gate width FETs (with zero drain to source bias) as the switching elements. A 20 GHz local oscillator buffer amplifier, a FET compatible balanced mixer, and a 5-8 GHz IF amplifier constitute the RF/IF sub-module. Phase shifter fabrication using ion implantation and a self-aligned gate technique is described. Preliminary RF results obtained on such phase shifters are included.

Sokolov, V.↗

IDR Muon Capture Front End and Variations

The (International Design Report) IDR neutrino factory scenario for capture, bunching, phase-energy rotation and initial cooling of {mu}'s produced from a proton source target is explored. It requires a drift section from the target, a bunching section and a {phi}-{delta}E rotation section leading into the cooling channel. The rf frequency changes along the bunching and rotation transport in order to form the 's into a train of equal-energy bunches suitable for cooling and acceleration. Optimization and variations are discussed. An important concern is rf limitations within the focusing magnetic fields; mitigation procedures are described. The method can be extended to provide muons for a {mu}{sup +}-{mu}{sup -} Collider; variations toward optimizing that extension are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiment study of an electron cyclotron resonant ion source based on a tapered resonance cavity

Electron cyclotron resonant plasma is one type of magnetised plasma generated by continuous microwave energy. It has the property of high degree of ionization and large volume at low gas pressure, which makes it useful for space propulsion and material processing. This article presents the experiment study of the plasma properties and ion beam extraction from an electron cyclotron resonant ion source based on a tapered resonance cavity. Optical emission spectroscopy based on a simple collisional radiation model was used for plasma diagnosis. Experiment results show that, at microwave power setting ranging from 7.06 to 17.40 W and mass flow rate ranging from 1 to 10 sccm, argon gas can be ionized. Ion beam of 109.1 mA from the ion source can be extracted at microwave power of 30 W, mass flow rate of 10 sccm, and accel voltage of 800 V. The diagnosed plasma temperature and density are 2.4–5.2 eV and 2 × 10{sup 16}–4.8 × 10{sup 17} m{sup −3}, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Muon Beam Emittance Evolution in the Helical Ionization Cooling Channel for Bright Muon Sources

The six-dimensional ionization cooling is essential to design a bright muon source. A geometry constraint is a challenge issue in a compact helical cooling channel (HCC). Especially, the HCC requires a large bore helical magnet and a compact helical RF system to incorporate the RF into the magnet chamber. A new emittance evolution has been designed to mitigate the geometry constraint. The HCC was functionally separated into three parts sections. The lattice at the initial section provides a large transverse acceptance by using a strong helical focus magnet. Once the transverse beam size is small enough to get into the compact RF the HCC lattice in the middle section generates a large longitudinal beta tune to dominate the longitudinal cooling. Consequently, the longitudinal emittance becomes smaller than the transverse one at the end of middle section. In the final section, the magnetic field strength is gradually reduced to match out the helical channel to the straight solenoid. As a result, the emittance exchange takes place and the final transverse emittance becomes smaller than the longitudinal one. The new emittance evolution scenario will be discussed in this presentation.

Derbenev, Yaroslav↗

Integrable Optics Design Principles for Beam Halo Suppression in Accelerator Rings at the Intensity Frontier

The project was dedicated to quantifying the possibilities and limitations of the integrable optics, a fundamentally new approach to high-intensity accelerator ring design, using the parallel Synergia framework for simulations. The following topics were studied: a) the effects of space charge forces, field errors, magnet misalignments, and other sources of parametric resonance; b) the effect of controlled nonlinearities, such as sextupoles for chromaticity control; c) the effect of longitudinal dynamics driven by finite bunch length and rf cavities; and d) reexamination of relevant lattices in present accelerators to explore potential benefits of these new design principles.

43 PARTICLE ACCELERATORS↗

Multipath induced errors in meteorological Doppler/interferometer location systems

One application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters is in tracking high-altitude balloons for meteorological studies. A source of error in this application is reflection of the signal from the sea surface. Through propagating and signal analysis, the magnitude of the reflection-induced error in both Doppler frequency measurements and interferometer phase measurements was estimated. The theory of diffuse scattering from random surfaces was applied to obtain the power spectral density of the reflected signal. The processing of the combined direct and reflected signals was then analyzed to find the statistics of the measurement error. It was found that the error varies greatly during the satellite overpass and attains its maximum value at closest approach. The maximum values of interferometer phase error and Doppler frequency error found for the system configuration considered were comparable to thermal noise-induced error.

Wallace, R. G.↗

RF Manipulation and Detection of Protons in the High Performance Antiproton Trap (HiPAT)

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter-derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility.

Martin, James J.↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

Low-Pressure Small-Radius Hydrogen Discharge as a Volume-Production Based Source of Negative Ions

The two-dimensional model of low-pressure discharges presented in the study provides description of hydrogen discharge maintenance in a free-fall regime with account for the volume produced negative ions in the discharge. The factors determining the spatial distribution of the plasma parameters, including that of the negative ions, in discharges with a localized rf power deposition and, respectively, with regions with remote plasma maintenance, are discussed. In agreement with previous one-dimensional models of hydrogen discharges maintained in a free-fall regime, the results show that small radius discharges sustain high density of volume-produced negative ions in the discharge center. This accumulation of the negative ions in the central part of the discharge where the rf power deposition is localized results from substantial influx of negative ions produced all over the discharge volume, i.e. from a nonlocal behavior of the discharge strongly predominating over the local balance of the ions associated with the elementary processes (collisions).

07 ISOTOPE AND RADIATION SOURCES↗

CW Room Temperature Re-Buncher for the Project X Front End

At Fermilab there is a plan to construct the Project X Injector Experiment (PXIE) facility - a prototype of the front end of the Project X, a multi-MW proton source based on superconducting linac. The construction and successful operations of this facility will validate the concept for the Project X front end, thereby minimizing the primary technical risk element within the Project. The room temperature front end of the linac contains an ion source, an RFQ accelerator and a Medium Energy Beam Transport (MEBT) section comprising a high bandwidth bunch selective chopper. The MEBT length is about 10 m, so three re-bunching CW cavities are used to support the beam longitudinal dynamics. The paper reports a RF design of the re-bunchers along with preliminary beam dynamic and thermal analysis of the cavities.

43 PARTICLE ACCELERATORS↗