Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Gamma Irradiation of Novel Optical Glasses at Elevated Temperature

Advanced Small Modular Reactors (AdvSMRs) are considered important future energy sources. However, in-vessel radiation fluxes are high and demands infrared (IR) optical fiberbased chemical sensing at temperatures that often exceed 400°C. This is a challenging environment for many current IR glasses, including covalently-bonded selenides and tellurides, such as As2Se3 and GeTe2, due their glass transition temperatures (Tg) being on the order of 200-350 °C. This work focuses on ?-irradiation affects at high temperatures on refractory ionic bonding based chalcogenide glasses in the BaS-La2S3-GeS2 system. Optical and selected physical properties were characterized before and after irradiation. It was found that both GeS2 and the 20BaS + 20La2S3 + 60GeS2 composition (in mole%) have minimal property changes when irradiated at 2.5 MGy cumulative dose at 300 °C. Sample density showed the largest characteristic change where densities initially decreased at 2 kGy dose, and then recovered at the highest dose of 2.5 MGy, resulting in an overall density change between 0.3 to 2%, depending on sample and composition. This work suggests the BaS-La2S3-GeS2 system as one for continued exploration as high temperature IR fiber sensors in radiation environments.

Gamma Irradiation, Novel Optical Glasses, Elevated↗

Facility Improvements and Modifications to Extend the Operational Life of the Modular Caustic-Side Solvent Extraction Process - 16082

Savannah River Remediation, LLC (SRR) is working to remove, stabilize, and dispose of approximately 36.7 million gallons (138.9 million liters) of liquid radioactive waste currently stored in 43 underground waste tanks, and ultimately close waste tanks. In 2008, as an interim salt treatment system to remove cesium from high level waste salt solutions prior to the Salt Waste Processing Facility start up, the Modular Caustic-Side Solvent Extraction Unit (MCU) initiated the removal of cesium from liquid radioactive salt waste prior to disposal. The MCU was designed and built for an expected three-year operational life and five-year design life. The first MCU cold runs began in June 2007 and hot startup was completed in April 2008. MCU remains in hot operation to this day, aiding in multiple, high-level tank closures. In an effort to continue liquid waste disposition at the Savannah River Site (SRS), equipment upgrades and operational improvements have been made to extend the life of the MCU beyond the original three years. Several pieces of fixed equipment have been converted into removable equipment which reduces the downtime associated with equipment change-outs and thereby reduces the dose to workers and processing impacts. Multiple pumps and filters have been upgraded to more robust designs. Process monitoring and controls have been upgraded to improve process performance. Redundant centrifugal contactor vibration equipment has been installed on each contactor in order to better assess the reliability, processing performance, and lifetime of the contactors. A new Solvent Hold Tank (SHT) Sampler has been installed to minimize the organic cross-contamination within the sampler, dose to workers, and sample analysis time. To increase processing availability and aid in visually obtained data, camera port has been added to the Salt Solution Feed Tank (SSFT). In order to decrease the overall background dose to the workers, the Process Vessel Ventilation (PVV) duct work now has the capability to be flushed to remove contamination. The caustic wash addition system has been modified to be a once-through system to improve equipment reliability, decrease downtime, and decrease dose to workers. In addition, the solvent that MCU utilizes to extract Cesium out of salt waste has been upgraded to Next Generation Solvent (NGS) which is based on MaxCalix extractant instead of a BobCalix extractant. Further, these upgrades and improvements have allowed MCU to be able to process at higher flow rates (up to 8.5 GPM) and with increased throughput (as high as 1.3 million gallons in FY13 and 5.3 million gallons since hot operations initiated) that have allowed SRR to continue the disposition of nuclear salt waste. The continued operation of MCU ensures more curies are stabilized into a glass matrix at SRS's Defense Waste Processing Facility (DWPF) and less curies are retained within South Carolina at SRS's Saltstone Disposal Facility (SDF). Unique challenges associated with modifying and improving a demonstration plant that is in hot operations and was designed to be temporary with a limited plant footprint have been successfully overcome. Further, creative strategies for removing old equipment have been utilized given the limited decontamination agents available for use that will not interfere with the organic solvent. This paper presents and discusses the deployment of these upgrades and operational improvements to MCU in order to allow continued, increased salt waste processing beyond the initial design life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Component-Level Inverse Design of Transmon Qubits Using Neural Networks

Designing a superconducting qubit to realize specific Hamiltonian parameters typically requires iterating through a time and compute-intensive forward loop in which the designer chooses a layout geometry, simulates it, extracts circuit parameters such as capacitances, and refines the geometry. We study the inverse version of this task using a neural-network workflow that maps target Hamiltonian parameters directly to component-level layout parameters, which we subsequently demonstrate on a planar transmon layout. During training, we pair the inverse model with a frozen forward surrogate model and evaluate the loss in Hamiltonian space rather than in layout-parameter space. In validation against a conventional EM solver, 97% of generated designs produce usable geometries, and the inverse-plus-surrogate pipeline reaches mean percent errors of 0.73% for qubit frequency and 1.58% for anharmonicity, comparable to or below the fabrication and simulation-to-measurement uncertainty expected for academic-process transmon devices of this type. A single pipeline query takes ~60 ms on CPU, versus ~2 min for a conventional EM capacitance extraction on the same hardware, a speedup of approximately 2,000x. Batching minimizes the AI model inference overhead, reducing the runtime to 3.1 microseconds per sample on CPU and 2.6 microseconds per sample on GPU at a batch size of 2048, resulting in speedups of 3.9 x 10^7 and 4.6 x 10^7, respectively, relative to a single conventional CPU EM extraction. Our results indicate that component-level inverse design usefully extends and complements conventional EM simulation, including for small datasets on the order of 1,000 samples.

Seidel, Olivia [Fermilab; Texas U., Arlington]↗

Ultrasound spectroscopy: application on MMC and PMC materials

Resonant Ultrasound Spectroscopy (RUS) is a simple technique for measuring the second-order elastic constants and ultrasonic attenuation of solids. The technique is based on measuring the spectrum of mechanical resonances for a sample of known shape (usually a sphere, cylinder, or parallelepiped). This spectrum cannot be deconvoluted to deduce the elastic constants. Instead, an approximate spectrum is calculated from the known sample dimensions, its mass, and a set of 'guessed' elastic constants. A multidimensional minimization of the rms difference between the measured and calculated spectra enables us to deduce all the elastic constants of the solid from a single frequency scan. Currently, the technique can be applied to crystals of orthorhombic symmetry (9 elastic constants) or higher using desktop computers and software developed for this purpose. Composite materials, especially fiber composites, can take full advantage of the RUS technique as they typically have low symmetry. In this paper we summarize the RUS technique and provide examples of its application to the elastic characterization of both fiber reinforced MMC's, and fiber reinforced PMC's.

36 MATERIALS SCIENCE↗

DATA QUALITY OBJECTIVES FOR SELECTING WASTE SAMPLES FOR BENCH-SCALE REFORMER TREATABILITY STUDIES

This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Bench-Scale Reforming testing. The type, quantity, and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluidized bed steam reformer. A determination of the adequacy of the fluidized bed steam reformer process to treat Hanford tank waste is required. The initial step in determining the adequacy of the fluidized bed steam reformer process is to select archived waste samples from the 222-S Laboratory that will be used in a bench scale tests. Analyses of the selected samples will be required to confirm the samples meet the shipping requirements and for comparison to the bench scale reformer (BSR) test sample selection requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-G-17A-03: MRIgRT: Quantification of Organ Motion

Purpose: To develop an MRI-based methodology and tools required for the quantification of organ motion on a dedicated MRI-guided radiotherapy system. A three-room facility, consisting of a TrueBeam 6X linac vault, a 1.5T MR suite and a brachytherapy interventional room, is currently under commissioning at our institution. The MR scanner can move and image in either room for diagnostic and treatment guidance purposes. Methods: A multi-imaging modality (MR, kV) phantom, featuring programmable 3D simple and complex motion trajectories, was used for the validation of several image sorting algorithms. The testing was performed on MRI (e.g. TrueFISP, TurboFLASH), 4D CT and 4D CBCT. The image sorting techniques were based on a) direct image pixel manipulation into columns or rows, b) single and aggregated pixel data tracking and c) using computer vision techniques for global pixel analysis. Subsequently, the motion phantom and sorting algorithms were utilized for commissioning of MR fast imaging techniques for 2D-cine and 4D data rendering. MR imaging protocols were optimized (e.g. readout gradient strength vs. SNR) to minimize the presence of susceptibility-induced distortions, which were reported through phantom experiments and numerical simulations. The system-related distortions were also quantified (dedicated field phantom) and treated as systematic shifts where relevant. Results: Image sorting algorithms were validated for specific MR-based applications such as quantification of organ motion, local data sampling, and 4D MRI for pre-RT delivery with accuracy better than the raw image pixel size (e.g. 1 mm). MR fast imaging sequences were commissioning and imaging strategies were developed to mitigate spatial artifacts with minimal penalty on the image spatial and temporal sampling. Workflows (e.g. liver) were optimized to include the new motion quantification tools for RT planning and daily patient setup verification. Conclusion: Comprehensive methods were developed and validated for the quantification of organ motion with applications in MRI-guided RT.

60 APPLIED LIFE SCIENCES↗

Measurement of Ionic Conductivity and Electrode Polarization at Low Temperatures on 8YSZ by a DC Technique

Measurement of ionic conductivity and electrode polarization resistance on a 8YSZ sample with platinum paste electrodes was conducted using a DC method with high input impedance meters over a temperature range from 119°C to 589°C. Over the entire temperature range, the meter resistance was much larger than the sample resistance including the polarization resistance. At lower temperatures, a faraday cage was used to minimize noise. The measured polarization resistance was also verified using electrochemical impedance spectroscopy. Ionic conductivity of 8YSZ exhibited Arrhenius behavior with an activation energy of ~1.1 eV, in good agreement with the literature. In the low current regime, electrode kinetics could be described by the linearized form of the Butler-Volmer equation. At higher current densities, electrode kinetics exhibited Tafel behavior. The polarization resistance exhibited Arrhenius behavior with the activation energy ranging between 1.05 and 1.27 eV. The present work shows that electrode polarizations can be investigated using a DC method. The approach may allow study of different electrodes in various atmospheres using one sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The U-tube: A new paradigm in borehole fluid sampling

Fluid samples from deep boreholes can provide insights into subsurface physical, chemical, and biological conditions. Recovery of intact, minimally altered aliquots of subsurface fluids is required for analysis of aqueous chemistry, isotopic composition, and dissolved gases, and for microbial community characterization. Unfortunately, for many reasons, collecting geofluids poses a number of challenges, from formation contamination by drilling to maintaining integrity during recovery from depths. Not only are there substantial engineering issues in retrieval of a representative sample, but there is often the practical reality that fluid sampling is just one of many activities planned for deep boreholes. The U-tube geochemical sampling system presents a new paradigm for deep borehole fluid sampling. Because the system is small, its ability to integrate with other measurement systems and technologies opens up numerous possibilities for multifunctional integrated wellbore completions. To date, the U-tube has been successfully deployed at four different field sites, each with a different deployment modality, at depths from 260 m to 2 km. While the U-tube has proven to be highly versatile, these installations have resulted in data that provide additional insights for improving future U-tube deployments.

54 ENVIRONMENTAL SCIENCES↗

Seasonal nitrous oxide flux from an intensively managed pasture in a humid subtropical ecosystem

Nitrous oxide (N2O) flux from vented chambers was measured over intensively and minimally managed bermuda grass hay meadows in a humid, subtropical ecosystem for several years during scheduled sampling protocol following harvest, fertilization and rainfall events while measuring diel N2O emissions once during each of 5 seasonal day growth cycles which divided each calendar year. Soil pools of nitrite NO2(-), nitrate NO3(-), and ammonia (NH3) were measured in soil samples taken at 2 and 10 cm depths during each emission collection to determine transformations of the nitrogen pools coupled with N2O emissions. The highest diel N2O emission occur midday in the Spring cycle, measuring 9.0 g N/ha/d only for several weeks, while emissions dropped to less than 1.0 g N/ha/day during hot, dry, and colder months. Intensively managed meadows (4 fertilizations and harvests per year plus pest management) induced higher seasonal N2O emissions than minimal treatment (1 fertilization and harvest) averaging 2.75 and 5.97 g N/ha/day. Nitrous oxide emission data as responses to soil parameters and environmental parameters were also measured where air temperature, soil moisture, and fertilization were the most powerful factors.

Brams, Eugene A.↗

Subsurface Noble Gas Sampling Manual

The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

58 GEOSCIENCES↗

Impact of Synthetic Parameters on Structure and Electrochemistry of High-Entropy Layered Oxide LiNi 0.2 Co 0.2 Mn 0.2 Al 0.2 Fe 0.2 O 2

Here, this study explored a high-entropy layered oxide (HELO), LiNi 0.2 Co 0.2 Mn 0.2 Al 0.2 Fe 0.2 O 2 , prepared by coprecipitation followed by heat treatment. Coprecipitation yielded a kinetically favored product, and the subsequent heat treatment under various temperatures and times allowed tuning the material toward more thermodynamically favored structures. Refinement of X-ray powder diffraction (XRD) revealed that after 450 °C treatment, ~12% of the Ni 2+ in the structure was located within the lithium cation layer. After heat treatment at 600, 700, and 800 °C, there was a continued decrease of Ni 2+ in the lithium cation layer to 9.3, 6.3, and 3.7%, respectively. Longer heat treatment times at 800 °C decreased the level to 2.5%. Electrochemical behavior was evaluated by cyclic voltammetry, galvanostatic cycling, rate capability testing, and electrochemical impedance spectroscopy, where increased loaded voltage, functional capacity, rate capability, and decreased impedance were observed for samples treated at higher temperatures with lower cation mixing. X-ray absorption near edge spectroscopy (XANES) data indicated that the redox activity of Ni and Co was dominant in the electrochemistry, while the participation of Mn or Fe was minimal. The level of Ni oxidation state change between charge and discharge related to the heat treatment temperature where the samples with high cation mixing showed lower capacity consistent with some Ni 3+ in the transition metal layer inaccessible for electron transfer. Longer heat treatment times at 800 °C did not continue to provide a benefit in electrochemical function even with some additional reduction in cation mixing.

25 ENERGY STORAGE↗

Revisiting a minimally destructive analytic approach for determining electrochemical kinetic parameters: Measuring aluminum corrosion across a wide pH range based on the Butler-Volmer equation

Here, this study revisits the three-point sampling of the simplified Butler-Volmer equation to address the limitations of strong potentiodynamic polarization, which can introduce irreversible damage and uncertainty in corrosion analysis. The method extracts electrochemical kinetic parameters while minimizing polarization effects, evaluates noise sensitivity relative to overpotential, and accounts for errors from signal noise, OCP drift, ohmic resistance, and mass-transfer constraints. Verified against the Tafel extrapolation method for aluminum corrosion across a wide pH range, this low-polarization approach enables accurate evaluations with specific error estimates, offering a robust alternative to linear polarization resistance methods that assume constant Tafel slopes.

36 MATERIALS SCIENCE↗

System for Packaging Planetary Samples for Return to Earth

A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

Badescu, Mircea↗

Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography

Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.

47 OTHER INSTRUMENTATION↗

A Simple Transient Thermal Test Assembly for Insulation Materials

A simple transient thermal test was developed for evaluating the thermal performance of high-temperature flexible insulation materials in atmospheric pressure air. The test setup was inspired by the test assembly used for evaluating the performance of fire shelters and fire protective clothing. The heating source used was a burner supplied with propane gas that can generate relatively uniform heating over a wide area. The ratio of the in-plane width to thickness of the insulation test sample in the test assembly was selected to be greater than ten so that the heat transfer in the center of the test assembly was nearly one-dimensional. A rigid, thin Inconel plate was used as the septum plate directly exposed to the flame to provide a relatively uniform, known-temperature boundary condition for the test assembly, and to prevent convective heat transfer through the test insulation from the burner. The test sample, flexible alumina paper insulation, was placed between the Inconel plate and a thin titanium witness plate. The overall assembly was further insulated using a combination of rigid and flexible ceramic insulations to minimize heat losses from the periphery of the test assembly. Thermocouples installed on the septum and witness plates and inside the insulation test sample provided temperature measurements at various locations. For the evaluation tests, the Inconel septum plate reached temperatures between 780°C and 850°C for tests with flame exposure durations of 120 sec to 300 sec. The measured temperatures for various tests with similar flame exposure times were repeatable. A one-dimensional numerical heat transfer model of the test assembly was developed. The close agreement between measured and predicted temperatures on the titanium witness plate and inside the insulation test sample indicated that this test may provide a one-dimensional thermal testing capability for evaluation of thermal performance of similar insulations.

Daryabeigi, Kamran↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Novel Applications of Focused Ion Beam Technique for Planetary Sample Analyses

We are using innovative FIB techniques to prepare samples of planetary materials for different types of coordinated analyses using ion microprobes, synchrotron beamlines, and specialized transmission electron microscopy (TEM) techniques. In these cases, the FIB sample preparation is the critical step in enabling these specialized analyses. We discuss several examples below utilizing the FEI Quanta3D instrument at the NASA Johnson Space Center. Trace element analyses utilizing synchrotron x-ray fluorescence. The trace element content of mineral grains in comet dust provides important clues on their formation and processing in the early solar system. We preformed coordinated analyses of a comet dust particle that had been prepared using ultramicrotomy for TEM analysis. Following the TEM analyses, we extracted a 70 nm thick section from a region of the carbon (C) film of the TEM grid, for additional analyses. A carbon ring ~2-3 μm thick was deposited on top of the C film using the FIB. The C film on the outer rim of the ring was milled away using various patterns to uniformly release the stresses on the film, preventing rupture and collapse, and was attached to the micromanipulator needle. We then isolated the ring completely and transferred the section to a silicon sample holder for analysis using the HXN (hard X-ray nanoprobe) beamline at NSLSII at Brookhaven National Lab. Coordinated Analyses of Presolar Grains. Rare sub-m presolar grains that originate in evolved stars and supernovae, occur in primitive astromaterials and are identified by their exotic isotopic compositions. Coordinated analyses of these grains using NanoSIMS, TEM, and other techniques on the same grain is enabled by innovative FIB sample preparation. In order to obtain subsequent isotopic analyses of Mg and Fe, contributions from surrounding grains were minimized. We precisely deposited a protective cap of Pt on top of the grain to preserve the grain of interest and then milled away about 5 μm diameter of the surrounding material. Following the isotopic analyses, the spindle was extracted and thinned to electron transparency for TEM microstructural analyses. In situ heating TEM experiments on lunar samples. We extracted a FIB thin section from Apollo 17 lunar rock 76015. To avoid ion-beam damage, e-beam deposition was used to deposit the first 500 nm of the C strap, followed by ion beam-assisted deposition of ~3 μm carbon. We performed an ex situ lift-out of the section and placed the section on one of the elements of a microelectromechanical systems (MEMS) - specialized heating substrate and attached the section to the substrate by depositing small C straps with the FIB. The heating chips utilize silicon nitride windows to support the samples and provide uniform heating while enabling TEM imaging. The heating chip was loaded into a Hitachi “Blaze” heating holder and analyzed using a Hitachi HF5000 at the University of Arizona.

Rahman, Z.↗

The Effect of Homogenization Heat Treatment on the Texture Evolution in U-10Mo Alloy

Uranium alloyed with 10 wt% Mo (U-10Mo) undergoes discontinuous precipitation (DP) when subjected to sub-eutectoid heat-treatment. It is hypothesized that the crystallographic texture of the U-10Mo can be modified to minimize the degree of DP, however the evolution of texture throughout the manufacturing process is not well understood. Crystallographic textures of two U-10Mo samples homogenized at 900°C and 1000°C were studied after uniaxial rolling and annealing. A total of 6 samples were analyzed upon rolling using a combination of hot and cold rolling conditions to strains of 83%, 90% and 97% and subsequently annealed at 700°C for one hour. Microstructures and textures were analyzed via electron backscatter diffraction (EBSD) for each homogenization, strain and post-annealed states. Results show that the U-10Mo exhibits typical rolling textures seen in body-centered cubic materials with increasing intensities of both a- and ?-fibers with increasing strain. After recrystallization, the texture appeared to be effectively randomized in all samples. Homogenization temperature showed no effect on the rolling and recrystallization behavior. Potential factors leading to the randomization of texture are discussed along with the implications of textures on the minimization of DP.

nuclear fuel, texture, rolling↗