Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Multi-Dimensional Measurements of Combustion Species in Flame Tube and Sector Gas Turbine Combustors

The higher temperature and pressure cycles of future aviation gas turbine combustors challenge designers to produce combustors that minimize their environmental impact while maintaining high operation efficiency. The development of low emissions combustors includes the reduction of unburned hydrocarbons, smoke, and particulates, as well as the reduction of oxides of nitrogen (NO(x)). In order to better understand and control the mechanisms that produce emissions, tools are needed to aid the development of combustor hardware. Current methods of measuring species within gas turbine combustors use extractive sampling of combustion gases to determine major species concentrations and to infer the bulk flame temperature. These methods cannot be used to measure unstable combustion products and have poor spatial and temporal resolution. The intrusive nature of gas sampling may also disturb the flow structure within a combustor. Planar laser-induced fluorescence (PLIF) is an optical technique for the measurement of combustion species. In addition to its non-intrusive nature, PLIF offers these advantages over gas sampling: high spatial resolution, high temporal resolution, the ability to measure unstable species, and the potential to measure combustion temperature. This thesis considers PLIF for in-situ visualization of combustion species as a tool for the design and evaluation of gas turbine combustor subcomponents. This work constitutes the first application of PLIF to the severe environment found in liquid-fueled, aviation gas turbine combustors. Technical and applied challenges are discussed. PLIF of OH was used to observe the flame structure within the post flame zone of a flame tube combustor, and within the flame zone of a sector combustor, for a variety of fuel injector configurations. OH was selected for measurement because it is a major combustion intermediate, playing a key role in the chemistry of combustion, and because its presence within the flame zone can serve as a qualitative marker of flame temperature. All images were taken in the environment of actual engines during flight, using actual jet fuel. The results of the PLIF study led directly to the modification of a fuel injector.

Hicks, Yolanda Royce↗

Dielectric Constant Measurements on Lunar Soils and Terrestrial Minerals

The return to the Moon has ignited the need to characterize the lunar regolith using in situ methods. An examination of the lunar regolith samples collected by the Apollo astronauts indicates that only a few minerals (silicates and oxides) need be considered for in situ resource utilization (ISRU). This simplifies the measurement requirements and allows a detailed analysis using simple methods. Characterizing the physical properties of the rocks and soils is difficult because of many complex parameters such as soil temperature, mineral type, grain size, porosity, and soil conductivity. In this presentation, we will show that the dielectric constant measurement can provide simple detection for oxides such as TiO2, FeO, and water. Their presence is manifest by an unusually large imaginary permittivity.

Anderson, R. C.↗

ALC/50/ values for some polymeric materials

Apparent lethal concentrations for 50 per cent of the test animals within a 30-min exposure period (ALC/50/) were determined for seventeen samples of polymeric materials, using the screening test method. The materials evaluated included resin-glass composites, film composites, and miscellaneous resins. ALC(50) values, based on weight of original sample charged, ranged from 24 to 110 mg/l. Modified phenolic resins seemed to exhibit less toxicity than the baseline epoxy resins. Among the film composites evaluated, only flame modified polyvinyl fluoride appeared to exhibit less toxicity than the baseline polyvinyl fluoride film.

Hilado, C. J.↗

A stochastic-dynamic model for global atmospheric mass-field statistics

Global atmospheric mass field error correlations based on satellite observations and on numerical forecasts show strong and systematic latitude dependence. A model for the latitude dependent spatial correlation structure of mass field forecast errors is derived from dynamical considerations. Three methods of solution were tested. In the first method, the equation was solved by expansion in spherical harmonics, and the correlation function was computed analytically using the expansion coefficients. In the second method, the finite difference equivalent of the equation was solved using a fast poisson solver. The correlation function was computed using stratified sampling of the individual realizations. In the third method, a higher order equation was derived, and solved directly in finite differences by two successive applications of the fast poisson solver. The three methods were compared for accuracy and efficiency, and the third method was chosen as clearly superior.

Ghil, M.↗

Acquisition and Retaining Granular Samples via a Rotating Coring Bit

This device takes advantage of the centrifugal forces that are generated when a coring bit is rotated, and a granular sample is entered into the bit while it is spinning, making it adhere to the internal wall of the bit, where it compacts itself into the wall of the bit. The bit can be specially designed to increase the effectiveness of regolith capturing while turning and penetrating the subsurface. The bit teeth can be oriented such that they direct the regolith toward the bit axis during the rotation of the bit. The bit can be designed with an internal flute that directs the regolith upward inside the bit. The use of both the teeth and flute can be implemented in the same bit. The bit can also be designed with an internal spiral into which the various particles wedge. In another implementation, the bit can be designed to collect regolith primarily from a specific depth. For that implementation, the bit can be designed such that when turning one way, the teeth guide the regolith outward of the bit and when turning in the opposite direction, the teeth will guide the regolith inward into the bit internal section. This mechanism can be implemented with or without an internal flute. The device is based on the use of a spinning coring bit (hollow interior) as a means of retaining granular sample, and the acquisition is done by inserting the bit into the subsurface of a regolith, soil, or powder. To demonstrate the concept, a commercial drill and a coring bit were used. The bit was turned and inserted into the soil that was contained in a bucket. While spinning the bit (at speeds of 600 to 700 RPM), the drill was lifted and the soil was retained inside the bit. To prove this point, the drill was turned horizontally, and the acquired soil was still inside the bit. The basic theory behind the process of retaining unconsolidated mass that can be acquired by the centrifugal forces of the bit is determined by noting that in order to stay inside the interior of the bit, the frictional force must be greater than the weight of the sample. The bit can be designed with an internal sleeve to serve as a container for granular samples. This tube-shaped component can be extracted upon completion of the sampling, and the bottom can be capped by placing the bit onto a corklike component. Then, upon removal of the internal tube, the top section can be sealed. The novel features of this device are: center dot A mechanism of acquiring and retaining granular samples using a coring bit without a closed door. center dot An acquisition bit that has internal structure such as a waffle pattern for compartmentalizing or helical internal flute to propel the sample inside the bit and help in acquiring and retaining granular samples. center dot A bit with an internal spiral into which the various particles wedge. center dot A design that provides a method of testing frictional properties of the granular samples and potentially segregating particles based on size and density. A controlled acceleration or deceleration may be used to drop the least-frictional particles or to eventually shear the unconsolidated material near the bit center.

Bar-Cohen, Yoseph↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Early detection of disease: The correlation of the volatile organic profiles from patients with upper respiratory infections with subjects of normal profiles

A method is described whereby a transevaporator is used for sampling 60-100 microns of aqueous sample. Volatiles are stripped from the sample either by a stream of helium and collection on a porous polymer, Tenax, or by 0.8 ml of 2-chloropropane and collected on glass beads. The volatiles are thermally desorbed into a precolumn which is connected to a capillary gas chromatographic column for analysis. The technique is shown to be reproducible and suitable for determining chromatographic profiles for a wide variety of sample types. Using a transevaporator sampling technique, the volatile profiles from 70 microns of serum were obtained by capillary column gas chromatography. The complex chromatograms were interpreted by a combination of manual and computer techniques and a two peak ratio method devised for the classification of normal and virus infected sera. Using the K-Nearest Neighbor approach, 85.7 percent of the unknown samples were classified correctly. Some preliminary results indicate the possible use of the method for the assessment of virus susceptibility.

Zlatkis, A.↗

A Novel Ultrasonic Method for Characterizing Microstructural Gradients in Tubular Structures

Ultrasonic velocity and time-of-flight (TOF) imaging that uses back surface reflections to gage volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse echo ultrasonic velocity and TOF imaging is that the image shows the effects of thickness as well as microstructural variations, unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse echo TOF based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples which, eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material in plate like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex shaped structures- those having (hollow) tubular or curved geometry. The experimental inspection technique and results are described as applied to a polymer matrix composite "proof of concept" tube that contains machined patches of various depths and an as manufactured monolithic silicon nitride ceramic tube that might be used in "real world" applications.

Roth, Don J.↗

Apparatus and methods for manipulation and optimization of biological systems

The invention provides systems and methods for manipulating, e.g., optimizing and controlling, biological systems, e.g., for eliciting a more desired biological response of biological sample, such as a tissue, organ, and/or a cell. In one aspect, systems and methods of the invention operate by efficiently searching through a large parametric space of stimuli and system parameters to manipulate, control, and optimize the response of biological samples sustained in the system, e.g., a bioreactor. In alternative aspects, systems include a device for sustaining cells or tissue samples, one or more actuators for stimulating the samples via biochemical, electromagnetic, thermal, mechanical, and/or optical stimulation, one or more sensors for measuring a biological response signal of the samples resulting from the stimulation of the sample. In one aspect, the systems and methods of the invention use at least one optimization algorithm to modify the actuator's control inputs for stimulation, responsive to the sensor's output of response signals. The compositions and methods of the invention can be used, e.g., to for systems optimization of any biological manufacturing or experimental system, e.g., bioreactors for proteins, e.g., therapeutic proteins, polypeptides or peptides for vaccines, and the like, small molecules (e.g., antibiotics), polysaccharides, lipids, and the like. Another use of the apparatus and methods includes combination drug therapy, e.g. optimal drug cocktail, directed cell proliferations and differentiations, e.g. in tissue engineering, e.g. neural progenitor cells differentiation, and discovery of key parameters in complex biological systems.

Ho, Chih-Ming↗

Assessment of damage in ceramics and ceramic matrix composites using ultrasonic techniques

This paper addresses the application of ultrasonic sensing to damage assessment in ceramics and ceramic matrix composites. It focuses on damage caused by thermal shock or oxidation at elevated temperatures, which often results in elastic anisotropy. This damaged-induced anisotropy is determined by measuring the velocities of ultrasonic waves in different propagation directions. Thermal shock damage is assessed in ceramic samples of reaction bonded silicon nitride (RBSN). Thermal shock treatment from different temperatures up to 1000 C is applied to produce the microcracks. Results indicate that most microcracks produced by thermal shock are located near sample surfaces. Ultrasonic measurements using the surface wave method are found to correlate well with measurements of degradation of mechanical properties obtained independently by other authors using destructive methods. Oxidation damage is assessed in silicon carbide fiber/reaction bonded silicon nitride matrix (SCS-6/RBSN) composites. The oxidation is done by exposing the samples in a flowing oxygen environment at elevated temperatures, up to 1400 C, for 100 hr. The Youngs' modulus in the fiber direction as obtained from ultrasonic measurements decreases significantly at 600 C but retains its original value at temperatures above 1200 C. This agrees well with the results of destructive tests by other authors. On the other hand, the transverse moduli obtained from ultrasonic measurements decrease continually until 1200 C. Measurements on the shear stiffnesses show behavior similar to the transverse moduli. The results of this work show that the damage-induced anisotropy in both ceramics and ceramic matrix composites can be determined successfully by ultrasonic methods. This suggests the possibility of assessing damage severity using ultrasonic techniques.

Chu, Y. C.↗

Enhanced Detection of Vibrio Cholerae in Oyster Homogenate Based on Centrifugal Removal of Inhibitory Agents

The disease cholera, caused by Vibrio cholerae, has been associated with consumption of contaminated seafood, including raw oysters. Detection of V. cholerae in foods typically involves blending the oysters, diluting the homogenate in alkaline peptone water (APW), overnight enrichment, and isolation on selective agar. Unfortunately, the oyster homogenate must be diluted to large volumes because lower dilutions inhibit the growth of V. cholerae. The goals of this study were to develop an alternative to large dilutions and to evaluate the basis for the inhibition observed in lower dilutions of oyster homogenates. Centrifugation of oyster homogenates at 10,000 x g for 15 min, followed by enrichment of the resulting pellet in APW, was found to eliminate the inhibition of V. cholerae growth. Inhibition appears not to be due to competing microflora but to a component(s) released when V. cholerae grows in the presence of oyster homogenate. The inhibitory component(s) kills the V. cholerae after the cell concentration reaches > 10(exp 8) cells/mL, rather than initially preventing their growth. The pH also declines from 8.0 to 5.5 during this period; however, the pH decline by itself appears not to cause V. cholerae death. Seven strains of V. cholerae (01 and non-01) and two strains of V. vulnificus were susceptible to the inhibitory agent(s). However, other Vibrio and non-Vibrio species tested were not inhibited by the oyster homogenates. Based on digestion of oyster homogenates with pronase, trypsin and lipase, the inhibitory reaction involves a protein(s). In a preliminary trial with oyster homogenate seeded with 1 cfu/g of V. cholerae, the modified centrifugation technique detected a slightly higher percentage of samples at a 1:10 dilution than the standard FDA Bacteriological Analytical Method (BAM) detected in uncentrifuged oyster homogenate at a 1:100 dilution. V. cholerae in seeded samples could also be detected more frequently by the modified centrifugation method than by PCR at a 1:10 dilution.

Alexander, Donita↗

Measurement of emissivity of industrial surfaces using a simple method

To detect emissivity, the drop in temperature of the sample undergoing radiation exchange with the wall in an evacuated space is measured over a given period. In this manner, emissivities of various synthetic resin lacquers, metals, and metallic coatings were measured. Once the emissivity is known, the same method can be used to detect specific heat and the head condition of gases.

Dallmeyer, H.↗

Quantification of Efficiency of Beneficiation of Lunar Regolith

Electrostatic beneficiation of lunar regolith is being researched at Kennedy Space Center to enhance the ilmenite concentration of the regolith for the production of oxygen in in-situ resource utilization on the lunar surface. Ilmenite enrichment of up to 200% was achieved using lunar simulants. For the most accurate quantification of the regolith particles, standard petrographic methods are typically followed, but in order to optimize the process, many hundreds of samples were generated in this study that made the standard analysis methods time prohibitive. In the current studies, X-ray photoelectron spectroscopy (XPS) and Secondary Electron microscopy/Energy Dispersive Spectroscopy (SEM/EDS) were used that could automatically, and quickly, analyze many separated fractions of lunar simulant. In order to test the accuracy of the quantification, test mixture samples of known quantities of ilmenite (2, 5, 10, and 20 wt%) in silica (pure quartz powder), were analyzed by XPS and EDS. The results showed that quantification for low concentrations of ilmenite in silica could be accurately achieved by both XPS and EDS, knowing the limitations of the techniques. 1

Trigwell, Steve↗

Space Station CMIF extended duration metabolic control test

The Space Station Extended Duration Metabolic Control Test (EMCT) was conducted at the MSFC Core Module Integration Facility. The primary objective of the EMCT was to gather performance data from a partially-closed regenerative Environmental Control and Life Support (ECLS) system functioning under steady-state conditions. Included is a description of the EMCT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements of water and gas samples taken during the test. A comparison of the physical, chemical, and microbiological methods used in the post test laboratory analyses of the water samples is included. The preprototype ECLS hardware used in the test, providing an overall process description and theory of operation for each hardware item. Analytical results pertaining to a system level mass balance and selected system power estimates are also included.

Schunk, Richard G.↗

Infrared spectra of crystalline and glassy silicates and application to interstellar dust

The infrared spectra of crystalline minerals predicted in theoretical condensation sequences do not match the astronomical observations. Since the astronomical spectra are a closer match to glassy silicates, the authors undertook a study to measure the infrared spectra of glassy silicates that have compositions similar to silicate minerals predicted in theoretical condensation sequences. The data should support observations aimed at elucidating condensation chemistry in dust forming regions. The authors measured the mass absorption coefficients, from 2.5 to 25 microns, of ground samples of olivine, diopside, and serpentine and also smoke samples that were prepared from these minerals. The smoke samples prepared in this way are predominantly glassy with nearly the same composition as the parent minerals. The crystalline samples consisted of pure olivine ((Fe(0.1)Mg(0.9))(2)SiO(4)), serpentine, diopside. Sample purity was confirmed by x ray diffraction. Each mineral was ground for 10 hours and a measured mass of the powder was mixed with KBr powder for absorption measurements using the method of Borghesi et a. (1985). The smoke samples were prepared from the same samples used for grinding by vaporizing the minerals using pulsed laser radiation in air. The smoke samples formed by condensation of the resulting vapor. The smoke settled onto infrared transparent KRS-5 substrates and onto a quartz crystal microbalance used to obtain mass measurements. A description of the preparation method is given in Stephens (1980). The glassy diopside showed only diffuse electron diffraction peaks and hence was nearly amorphous, while the serpentine smoke showed a weak diffraction pattern corresponding to MgO. The smoke from olivine showed a weak diffraction pattern corresponding to Fe2O3 and/or Fe3O4. The mass absorption coefficients, from 2.5 to 25 microns, of crystalline diopside, olivine, and serpentine and their corresponding smoke samples are shown in figures.

Stephens, John R.↗

Characterization of Candidate Materials for Remote Recession Measurements of Ablative Heat Shield Materials

A method of remotely measuring surface recession of a material sample in a plasma flow through emission spectroscopy of the post shock layer was characterized through experiments in the NASA Langley HYMETS arc jet facility. Different methods for delivering the seed products into the Phenolic Impregnated Carbon Ablator (PICA) material samples were investigated. Three samples were produced by seeding the PICA material with combinations of Al, Si, HfO2, VB2, Al2O3, SiO2, TiC, HfC, NaCl, and MgCl2 through infusing seed materials into a core of PICA, or through encapsulating seed material in an epoxy disk, mechanically bonding the disk to a PICA sample. The PICA samples seeded with the candidate tracers were then tested at surface temperatures near 2400 K under low pressure air plasma. The emission of Al, Ti, V, Na, and Mg in the post-shock layer was observed in the UV with a high resolution imaging spectrometer viewing the whole stagnation line from the side, and from UV to NIR with a fiber-coupled miniaturized spectrometer observing the sample surface in the wavelength range from 200 nm to 1,100 nm from the front through a collimator. Al, Na, and Mg were found to be emitting in the post-shock spectra even before the recession reached the seeding depth - therefore possibly characterizing the pyrolysis process rather than the recession itself. The appearance of Ti and V emission in the spectra was well correlated with the actual recession which was monitored through a video of the front surface of the sample. The applicability of a seed material as an indicator for recession appears to be related to the melting temperature of the seed material. Future parametric studies will be carried out in low power plasma facilities at the University of Kentucky.

Butler, Bradley D.↗

Progress in multirate digital control system design

A new methodology for multirate sampled-data control design based on a new generalized control law structure, two new parameter-optimization-based control law synthesis methods, and a new singular-value-based robustness analysis method are described. The control law structure can represent multirate sampled-data control laws of arbitrary structure and dynamic order, with arbitrarily prescribed sampling rates for all sensors and update rates for all processor states and actuators. The two control law synthesis methods employ numerical optimization to determine values for the control law parameters. The robustness analysis method is based on the multivariable Nyquist criterion applied to the loop transfer function for the sampling period equal to the period of repetition of the system's complete sampling/update schedule. The complete methodology is demonstrated by application to the design of a combination yaw damper and modal suppression system for a commercial aircraft.

Berg, Martin C.↗