Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Accelerating Hamiltonian Monte Carlo for Bayesian inference in neural networks and neural operators

Hamiltonian Monte Carlo (HMC) is a powerful and accurate method to sample from the posterior distribution in Bayesian inference. However, HMC techniques are computationally demanding for Bayesian neural networks due to the high dimensionality of the network’s parameter space and the non-convexity of their posterior distributions. Therefore, various approximation techniques, such as variational inference (VI) or stochastic gradient MCMC, are often employed to infer the posterior distribution of the network parameters. Such approximations introduce inaccuracies in the inferred distributions, resulting in unreliable uncertainty estimates. In this work, we propose a hybrid approach that combines inexpensive VI and accurate HMC methods to efficiently and accurately quantify uncertainties in neural networks and neural operators. The proposed approach leverages an initial VI training on the full network. We examine the influence of individual parameters on the prediction uncertainty, which shows that a large proportion of the parameters do not contribute substantially to uncertainty in the network predictions. This information is then used to significantly reduce the dimension of the parameter space, and HMC is performed only for the subset of network parameters that strongly influence prediction uncertainties. This yields a framework for accelerating the full batch HMC for posterior inference in neural networks. We demonstrate the efficiency and accuracy of the proposed framework on deep neural networks and operator networks, showing that inference can be performed for large networks with tens to hundreds of thousands of parameters. Finally, we show that this method can effectively learn surrogates for complex physical systems by modeling the operator that maps from upstream conditions to wall-pressure data on a cone in hypersonic flow.

Bayesian inference↗

Fabrication of Cs{sub 2.5}H{sub 0.5}PW{sub 12}O{sub 40} three-dimensional ordered film by colloidal crystal template

A three-dimensional ordered polyoxometalate periodic film was synthesized using dodecatungstophosphoric acid (H{sub 3}PW{sub 12}O{sub 40}) and Cs{sub 2}CO{sub 3} as precursors and colloidal crystals as templates by an inverse opal method. The samples were characterized by elemental analysis, XRD, IR spectra, UV-Vis diffuse reflectance spectra (DR-UV-Vis) and SEM techniques. This arrayed film constructed by pure cesium salt of dodecatungstophosphoric acid Cs{sub 2.5}H{sub 0.5}PW{sub 12}O{sub 40} nanoparticles shows well-defined lamellar array with inverse opal structure, which exhibits a well-defined photonic band gap. - Graphical abstract: A three-dimensional ordered Cs{sub 2.5}H{sub 0.5}PW{sub 12}O{sub 40} periodic film was synthesized by an inverse opal method using H{sub 3}PW{sub 12}O{sub 40} and Cs{sub 2}CO{sub 3} as precursors via nanocasting route and colloidal crystal as template (all scale bars are 1 {mu}m).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sci-Thur AM: YIS – 01: New technologies for astatine-211 targeted alpha therapy research

Purpose: The short-range, densely ionizing α-particles emitted by {sup 211}At (t{sub 1/2}=7.2h) are well suited for the treatment of diffuse microscopic disease, using cancer targeting biomolecules. {sup 211}At availability is limited by the rarity of α-cyclotrons required for standard production. Image-based dosimetry is also limited for {sup 211}At, which emits low intensity X-rays. Our goal was to leverage state-of-the-art infrastructure at TRIUMF to produce and evaluate two related isotopes, {sup 211}Rn (t{sub 1/2}=14.6h, 73% decay to {sup 211}At) as a generator for {sup 211}At, and {sup 209}At (t{sub 1/2}=5.4h, X-ray/gamma-ray emitter) as a novel 211At surrogate for preclinical imaging studies. Methods: Produced by spallation of uranium with 480 MeV protons, mass separated ion beams of short-lived francium isotopes were implanted into NaCl targets where {sup 211}Rn or {sup 209}At were produced by radioactive decay, in situ. {sup 211}Rn was transferred to dodecane from which {sup 211}At was efficiently extracted and evaluated for clinical applicability. High energy SPECT/CT was evaluated for measuring {sup 209}At activity distributions in mice and phantoms. Results: Our small scale {sup 211}Rn/{sup 211}At generator system provided high purity {sup 211}At samples. The methods are immediately scalable to the level of radioactivity required for in vivo experiments with {sup 211}At. {sup 209}At-based high energy SPECT imaging was determined suitable for pursuing image-based dosimetry in mouse tumour models. In the future, we will utilize quantitative {sup 209}At-SPECT for image-based dose calculations. Conclusion: These early studies provided a foundation for future endeavours with {sup 211}At-based α-therapy. Canada is now significantly closer to clinical targeted α-therapy of cancer.

60 APPLIED LIFE SCIENCES↗

A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging

In mass spectrometry imaging of tissues, the size of structures that can be distinguished is determined by the spatial resolution of the imaging technique. Here, the spatial resolution of IR laser ablation is markedly improved by increasing the distance between the laser and the focusing lens. As the distance between the laser and the lens is increased from 1 to 18 m, the ablation spot size decreases from 440 to 44 μm. This way, only the collimated center of the divergent laser beam is directed on the focusing lens, which results in better focusing of the beam. Part of the laser energy is lost at longer distance, but this is compensated by focusing of the radiation to a smaller area on the sample surface. The long distance can also be achieved by a set of mirrors, between which the radiation travels before it is directed to the focusing lens and the sample. This method for improving the spatial resolution can be utilized in mass spectrometry imaging of tissues by techniques that utilize IR laser ablation, such as laser ablation electrospray ionization, laser ablation atmospheric pressure photoionization, and matrix-assisted laser desorption electrospray ionization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid determination of actinides in asphalt samples

A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organics present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High vacuum cells for classical surface techniques

Novel glass cells were designed and built to be able to perform surface potential and surface tension measurements in a contained environment. The cells can withstand pressures of approximately 1x10{sup -6} Torr, providing a reasonable level of control in terms of the amounts of volatile contaminants during experimentation. The measurements can take several hours; thus the cells help maintain the integrity of the sample in the course of the experiment. To test for the feasibility of the cell design, calibration measurements were performed. For the surface potential cell, the modified TREK 6000B-7C probe exhibited performance comparable to its unmodified counterpart. The correlation measurements between applied potential on the test surface and the measured potential showed R-values very close to 1 as well as standard deviation values of less than 1. Results also demonstrate improved measurement values for experiments performed in vacuum. The surface tension cell, on the other hand, which was used to perform the pendant drop method, was tested on common liquids and showed percentage errors of 0.5% when compared to literature values. The fabricated cells redefine measurements using classical surface techniques, providing unique and novel methods of sample preparation, premeasurement preparation, and sample analysis at highly beneficial expenditure cost.

36 MATERIALS SCIENCE↗

Langevin dynamics of generalized spins as SU( N ) coherent states

Classical models of spin systems traditionally retain only the dipole moments, but a quantum spin state will frequently have additional structure. Spins of magnitude S have N = 2⁢S + 1 levels. Alternatively, the spin state is fully characterized by a set of N 2 - 1 local physical observables, which we interpret as generalized spin components. For example, a spin with S = 1 has three dipole components and five quadrupole components. Further, these components evolve under a generalization of the classical Landau-Lifshitz dynamics, which can be extended with noise and damping terms. In this paper, we reformulate the dynamical equations of motion as a Langevin dynamics of SU(N) coherent states in the Schrödinger picture. This viewpoint is especially useful as the basis for an efficient numerical method to sample spin configurations in thermal equilibrium and to simulate the relaxation and driven motion of topological solitons. To illustrate the approach, we simulate a nonequilibrium relaxation process that creates CP 2 skyrmions, which are topological defects with both dipole and quadrupole character.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

SSAGES: Software Suite for Advanced General Ensemble Simulations

Molecular simulation has emerged as an essential tool for modern-day research, but obtaining proper results and making reliable conclusions from simulations requires adequate sampling of the system under consideration. To this end, a variety of methods exist in the literature that can enhance sampling considerably, and increasingly sophisticated, effective algorithms continue to be developed at a rapid pace. Implementation of these techniques, however, can be challenging for experts and non-experts alike. There is a clear need for software that provides rapid, reliable, and easy access to a wide range of advanced sampling methods, and that facilitates implementation of new techniques as they emerge. Here we present SSAGES, a publicly available Software Suite for Advanced General Ensemble Simulations designed to interface with multiple widely used molecular dynamics simulations packages. SSAGES allows facile application of a variety of enhanced sampling techniques—including adaptive biasing force, string methods, and forward flux sampling—that extract meaningful free energy and transition path data from all-atom and coarse grained simulations. A noteworthy feature of SSAGES is a user-friendly framework that facilitates further development and implementation of new methods and collective variables. In this study, the use of SSAGES is illustrated in the context of simple representative applications involving distinct methods and different collective variables that are available in the current release of the suite.

97 MATHEMATICS AND COMPUTING↗

Structural and Mechanical Analysis of Individual Mineralized Collagen Fibrils Using In Situ Transmission Electron Microscopy

Bone serves as an example of nature’s architectured material with its characteristic blend of strength and toughness, all at a lightweight design. Given the hierarchical nature of these materials, it is essential to understand the governing mechanisms and organization of their constituents across length scales for bioinspired structural design. Despite recent advances in transmission electron microscopy (TEM) that have allowed us to witness the hierarchical arrangement of bone at micro-down to the nanoscale, we are still missing the details about the structural organization and mechanical properties of the main building blocks of bone─mineralized collagen fibrils (MCFs). Here, we present a method to extract individual MCFs from nature’s model material, mineralized turkey leg tendon, using a dropcasting procedure. By isolating the MCFs onto TEM supporting grids, we visualized the arrangement of organic and mineral phases within individual MCFs at the nanoscale. Using a four-dimensional scanning transmission electron microscopy (4D-STEM) approach, the orientation of individual mineral crystals within the MCFs was examined. Furthermore, we conducted in situ tensile experiments, revealing exceptional tensile strains of at least 8%, demonstrating the intricate relationship between structural organization and the mechanical behavior of MCFs. These insights into the ultrastructure of mineralized tissue building blocks, as well as the proposed sample-extraction method compatible with in situ mechanical testing, provide a strong basis for research into nature-inspired material design.

4D-STEM↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

ANI-1: an extensible neural network potential with DFT accuracy at force field computational cost

Deep learning is revolutionizing many areas of science and technology, especially image, text, and speech recognition. In this paper, we demonstrate how a deep neural network (NN) trained on quantum mechanical (QM) DFT calculations can learn an accurate and transferable potential for organic molecules. We introduce ANAKIN-ME (Accurate NeurAl networK engINe for Molecular Energies) or ANI for short. ANI is a new method designed with the intent of developing transferable neural network potentials that utilize a highly-modified version of the Behler and Parrinello symmetry functions to build single-atom atomic environment vectors (AEV) as a molecular representation. AEVs provide the ability to train neural networks to data that spans both configurational and conformational space, a feat not previously accomplished on this scale. We utilized ANI to build a potential called ANI-1, which was trained on a subset of the GDB databases with up to 8 heavy atoms in order to predict total energies for organic molecules containing four atom types: H, C, N, and O. To obtain an accelerated but physically relevant sampling of molecular potential surfaces, we also proposed a Normal Mode Sampling (NMS) method for generating molecular conformations. Through a series of case studies, we show that ANI-1 is chemically accurate compared to reference DFT calculations on much larger molecular systems (up to 54 atoms) than those included in the training data set.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solution Combustion Synthesis of Fe{sub 3}O{sub 4} Powders Using Mixture of CTAB and Citric Acid Fuels

Magnetite (Fe{sub 3}O{sub 4}) powders were synthesized by solution combustion method using a mixture of cetyltrimethylammonium bromide (CTAB) and citric acid fuels at various fuel to oxidant ratios (ϕ = 0.5, 1, 1.5, and 2). Phase evolution investigated by x-ray diffraction method showed single-phase Fe{sub 3}O{sub 4} powders were only formed at ϕ = 1 using mixture of fuels, while impurity α-Fe{sub 2}O{sub 3} phase together with magnetite phase was completely disappeared at ϕ = 2 for CTAB fuel alone. The specific surface area and porous structures of the as-combusted Fe{sub 3}O{sub 4} powders were characterized by N{sub 2} adsorption-desorption isotherms and scanning electron microscopy techniques, respectively. The specific surface area using the mixture of fuels (37 m{sup 2}/g) was higher than that of CTAB fuel alone (32 m{sup 2}/g). Magnetic properties of the as-combusted powders were studied by vibration sample magnetometry method. The highest saturation magnetization of 83 emu/g was achieved by mixture of fuels at ϕ = 1, due to the high purity and large particle size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Underground Test Area Activity Sampling Technologies Evaluation Report, Nevada National Security Site, Nye County, Nevada, Revision 0

This report presents the results of the next stage of sampling technology evaluations as described in Underground Test Area Activity Sampling Technologies Methods Plan (N-I, 2014b). Testing of the BESST Blatypus system was originally planned; however, communications with the vendor indicated it is premature for the UGTA Activity to field test this technology. The system currently uses latex tubing and nitrogen gas to push the water to the surface. The large amount of nitrogen gas needed due to the depths of the UGTA wells makes this unfeasible. Also, the latex tubing will likely not hold up in steel tubing. Instead, three technologies were evaluated: depth-discrete bailer, jack pump, and submersible pump. Each of these is a proven technology for certain conditions. The evaluation includes logistical and operational data collected during the purging of the well or completion interval and groundwater sampling at three wells.

54 ENVIRONMENTAL SCIENCES↗

THE SPARSEST CLUSTERS WITH O STARS

There is much debate on how high-mass star formation varies with environment, and whether the sparsest star-forming environments are capable of forming massive stars. To address this issue, we have observed eight apparently isolated OB stars in the Small Magellanic Cloud (SMC) using Hubble Space Telescope's Advanced Camera for Surveys. Five of these objects appear as isolated stars, two of which are confirmed to be runaways. The remaining three objects are found to exist in sparse clusters, with {approx}<10 companion stars revealed, having masses of 1-4 M{sub sun}. Stochastic effects dominate in these sparse clusters, so we perform Monte Carlo simulations to explore how our observations fit within the framework of empirical, galactic cluster properties. We generate clusters using a simplistic -2 power-law distribution for either the number of stars per cluster (N{sub *}) or cluster mass (M{sub cl}). These clusters are then populated with stars randomly chosen from a Kroupa initial mass function (IMF). We find that simulations with cluster lower-mass limits of M{sub cl,lo} {>=} 20 M{sub sun} and N{sub *,lo} {>=} 40 match best with observations of SMC and Galactic OB star populations. We examine the mass ratio of the second most massive and most massive stars m{sub max,2}/m{sub max}, finding that our observations all exist below the 20th percentile of our simulated clusters. However, all of our observed clusters lie within the parameter space spanned by the simulated clusters, although some are in the lowest 5th percentile frequency. These results suggest that clusters are built stochastically by randomly sampling stars from a universal IMF with a fixed stellar upper-mass limit. In particular, we see no evidence to suggest an m{sub max}-M{sub cl} relation. Our results may be more consistent with core accretion models of star formation than with competitive accretion models, and they are inconsistent with the proposed steepening of the integrated galactic stellar initial mass function (IGIMF).

79 ASTRONOMY AND ASTROPHYSICS↗

Diversity of Antibiotic Resistance genes and Transfer Elements-Quantitative Monitoring (DARTE-QM): a method for detection of antimicrobial resistance in environmental samples

Effective monitoring of antibiotic resistance genes and their dissemination in environmental ecosystems has been hindered by the cost and efficiency of methods available for the task. We developed the Diversity of Antibiotic Resistance genes and Transfer Elements-Quantitative Monitoring (DARTE-QM), a method implementing TruSeq high-throughput sequencing to simultaneously sequence thousands of antibiotic resistant gene targets representing a full-spectrum of antibiotic resistance classes common to environmental systems. In this study, we demonstrated DARTE-QM by screening 662 antibiotic resistance genes within complex environmental samples originated from manure, soil, and livestock feces, in addition to a mock-community reference to assess sensitivity and specificity. DARTE-QM offers a new approach to studying antibiotic resistance in environmental microbiomes, showing advantages in efficiency and the ability to scale for many samples. This method provides a means of data acquisition that will alleviate some of the obstacles that many researchers in this area currently face.

59 BASIC BIOLOGICAL SCIENCES↗

A D-term Modeling Code (DMC) for Simultaneous Calibration and Full-Stokes Imaging of Very Long Baseline Interferometric Data

In this paper we present DMC, a model and associated tool for polarimetric imaging of very long baseline interferometry data sets that simultaneously reconstructs the full-Stokes emission structure along with the station-based gain and leakage calibration terms. DMC formulates the imaging problem in terms of posterior exploration, which is achieved using Hamiltonian Monte Carlo sampling. The resulting posterior distribution provides a natural quantification of uncertainty in both the image structure and the data calibration. We run DMC on both synthetic and real data sets, the results of which demonstrate its ability to accurately recover both the image structure and calibration quantities, as well as to assess their corresponding uncertainties. The framework underpinning DMC is flexible, and its specific implementation is under continued development.

47 OTHER INSTRUMENTATION↗

Detecting differential protein expression in large-scale population proteomics

Mass spectrometry-based high-throughput quantitative proteomics shows great potential in clinical biomarker studies, identifying and quantifying thousands of proteins in biological samples. However, methods are needed to appropriately handle issues/challenges unique to mass spectrometry data in order to detect as many biomarker proteins as possible. One issue is that different mass spectrometry experiments generate quite different total numbers of quantified peptides, which can result in more missing peptide abundances in an experiment with a smaller total number of quantified peptides. Another issue is that the quantification of peptides is sometimes absent, especially for less abundant peptides and such missing values contain the information about the peptide abundance. Here, we propose a Significance Analysis for Large-scale Proteomics Studies (SALPS) that handles missing peptide intensity values caused by the two mechanisms mentioned above. Our model has a robust performance in both simulated data and proteomics data from a large clinical study. Because varying patients’ sample qualities and deviating instrument performances are not avoidable for clinical studies performed over the course of several years, we believe that our approach will be useful to analyze large-scale clinical proteomics data.

Environmental Molecular Sciences Laboratory↗