Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Comprehensive, Quantitative Risk Assessment of CO 2 Geologic Sequestration (Final Technical Report)

A Quantitative Failure Modes and Effects Analysis (QFMEA) was developed to conduct comprehensive, quantitative risk assessments on CO 2 capture, transportation, and sequestration or use in deep saline aquifers, enhanced oil recovery operations, or enhanced coal bed methane operations. The model identifies and characterizes potential risks; identifies the likely failure modes, causes, effects and methods of detection; lists possible risk prevention and risk mitigation steps; estimates potential damage recovery costs, mitigation costs and costs savings resulting from mitigation; and ranks (prioritizes) risks according to the probability of failure, the severity of failure, the difficulty of early failure detection and the potential for fatalities. The QFMEA model generates the necessary information needed for effective project risk management. Diverse project information can be integrated into a concise, common format that allows comprehensive, quantitative analysis, by a cross-functional team of experts, to determine: What can possibly go wrong? How much will damage recovery cost? How can it be prevented or mitigated? What is the cost savings or benefit of prevention or mitigation? Which risks should be given highest priority for resolution? The QFMEA model can be tailored to specific projects and is applicable to new projects as well as mature projects. The model can be revised and updated as new information comes available. It accepts input from multiple sources, such as literature searches, site characterization, field data, computer simulations, analogues, process influence diagrams, probability density functions, financial analysis models, cost factors, and heuristic best practices manuals, and converts the information into a standardized format in an Excel spreadsheet. Process influence diagrams, geologic models, financial models, cost factors and an insurance schedule were developed to support the QFMEA model. Comprehensive, quantitative risk assessments were conducted on three (3) sites using the QFMEA model: (1) SACROC Northern Platform CO 2 -EOR Site in the Permian Basin, Scurry County, TX, (2) Pump Canyon CO 2 -ECBM Site in the San Juan Basin, San Juan County, NM, and (3) Farnsworth Unit CO 2 -EOR Site in the Anadarko Basin, Ochiltree County, TX. The sites were sufficiently different from each other to test the robustness of the QFMEA model.

54 ENVIRONMENTAL SCIENCES↗

Using Gravitational Lensing to Probe for Candidate Quintessential Galaxies in the Epoch of Reionization

Abstract Understanding the properties of the first generation of galaxies is an ongoing challenge in observational astrophysics. James Webb Space Telescope deep-field observations have led to the identification of large numbers of galaxies within the Epoch of Reionization (EoR); however, it remains observationally challenging to study the detailed properties of the most numerous, faint high- z galaxies without strong gravitational lensing. To this end, we present five m AB ≃ 24 galaxies, all projected behind the cores of massive clusters where high lensing magnifications significantly (≳1.5 mag) boost their observed brightness. These galaxies are each characterized by a drop-off in their spectra between the near-IR and optical wavelengths, suggesting the presence of a Lyman break at z > 6. The bright sources enable precise dropout color constraints. We combine the dropout data with follow-up imaging to constrain continuum slopes redward of their breaks. Using the open-source spectral energy distribution modeling software Prospector , we characterize two of these galaxies as probable high- z ( z ∼ 6.5–7) and three as probable low- z ( z ∼ 2) sources, demonstrating that for very bright ( m AB < 24) dropout candidates even limited photometric data have good power to distinguish between high- z galaxies and red or dusty low- z galaxies. The two candidate high- z dropouts are comparably bright to the brightest galaxies identified at such redshifts in deep fields, but due to lensing magnifications are intrinsically fainter by at least 1.5 mag. If confirmed, these galaxies represent exciting laboratories for performing detailed follow-up studies of galaxy properties within the EoR.

Roberson, Joshua [University of Cincinnati] (ORCID↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of ultrafast capabilities for X-ray free-electron lasers at the linac coherent light source

The ability to produce ultrashort, high-brightness X-ray pulses is revolutionizing the field of ultrafast X-ray spectroscopy. Free-electron laser (FEL) facilities are driving this revolution, but unique aspects of the FEL process make the required characterization and use of the pulses challenging. In this paper, we describe a number of developments in the generation of ultrashort X-ray FEL pulses, and the concomitant progress in the experimental capabilities necessary for their characterization and use at the Linac Coherent Light Source. This includes the development of sub-femtosecond hard and soft X-ray pulses, along with ultrafast characterization techniques for these pulses. We also describe improved techniques for optical cross-correlation as needed to address the persistent challenge of external optical laser synchronization with these ultrashort X-ray pulses.

36 MATERIALS SCIENCE↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for gamma-ray-emitting active galactic nuclei in the Fermi-LAT unassociated sample using machine learning

The second Fermi-LAT source catalog (2FGL) is the deepest all-sky survey available in the gamma-ray band. It contains 1873 sources, of which 576 remain unassociated. Machine-learning algorithms can be trained on the gamma-ray properties of known active galactic nuclei (AGNs) to find objects with AGN-like properties in the unassociated sample. This analysis finds 231 high-confidence AGN candidates, with increased robustness provided by intersecting two complementary algorithms. A method to estimate the performance of the classification algorithm is also presented, that takes into account the differences between associated and unassociated gamma-ray sources. Follow-up observations targeting AGN candidates, or studies of multiwavelength archival data, will reduce the number of unassociated gamma-ray sources and contribute to a more complete characterization of the population of gamma-ray emitting AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Developing a heavy-duty vehicle activity database to estimate start and idle emissions

Heavy-duty vehicle start and idling activities were characterized from two datasets to improve emission estimates in the MOtor Vehicle Emission Simulator (MOVES): 1. Fleet DNA from the National Renewable Energy Laboratory (NREL) and 2. A dataset collected by the University of California, Riverside for the California Air Resources Board. Furthermore, the combined dataset includes 564 commercial vehicles, over 23,000 vehicle days of operation and covers seven of the nine heavy-duty source types defined by MOVES. The start and idle activities are characterized and illustrated across MOVES source types, vocations, fleets, days, and hours. This study provides the most comprehensive analysis yet made publicly available to characterize start and idle activity for heavy-duty vehicles within the United States. The results also show there is significant uncertainty in the average heavy-duty idle and start activity due to the large variation in activity across fleets and vocations, and sparsity of nation-wide vehicle population data by vocation.

33 ADVANCED PROPULSION SYSTEMS↗

A VLA SURVEY FOR FAINT COMPACT RADIO SOURCES IN THE ORION NEBULA CLUSTER

We present Karl G. Jansky Very Large Array 1.3, 3.6, and 6 cm continuum maps of compact radio sources in the Orion Nebular Cluster (ONC). We mosaicked 34 arcmin{sup 2} at 1.3 cm, 70 arcmin{sup 2} at 3.6 cm and 109 arcmin{sup 2} at 6 cm, containing 778 near-infrared detected young stellar objects and 190 Hubble Space Telescope -identified proplyds (with significant overlap between those characterizations). We detected radio emission from 175 compact radio sources in the ONC, including 26 sources that were detected for the first time at these wavelengths. For each detected source, we fitted a simple free–free and dust emission model to characterize the radio emission. We extrapolate the free–free emission spectrum model for each source to ALMA bands to illustrate how these measurements could be used to correctly measure protoplanetary disk dust masses from submillimeter flux measurements. Finally, we compare the fluxes measured in this survey with previously measured fluxes for our targets, as well as four separate epochs of 1.3 cm data, to search for and quantify the variability of our sources.

79 ASTRONOMY AND ASTROPHYSICS↗

MeV bremsstrahlung X rays from intense laser interaction with solid foils

Laser-based compact MeV X-ray sources are useful for a variety of applications such as radiography and active interrogation of nuclear materials. MeV X rays are typically generated by impinging the intense laser onto ~mm-thick high-Z foil. Here, we have characterized such a MeV X-ray source from 120 TW (80 J, 650 fs) laser interaction with a 1 mm-thick tantalum foil. Our measurements show X-ray temperature of 2.5 MeV, flux of 3 × 10 12 photons/sr/shot, beam divergence of ~0.1 sr, conversion efficiency of ~1%, that is, ~1 J of MeV X rays out of 80 J incident laser, and source size of 80 m. Our measurement also shows that MeV X-ray yield and temperature is largely insensitive to nanosecond laser contrasts up to 10 -5 . Also, preliminary measurements of similar MeV X-ray source using a double-foil scheme, where the laser-driven hot electrons from a thin foil undergoing relativistic transparency impinging onto a second high-Z converter foil separated by 50–400 m, show MeV X-ray yield more than an order of magnitude lower compared with the single-foil results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the CW starter plasma RF matching network for operating the SNS H{sup −} ion source with lower H{sub 2} flows

The Spallation Neutron Source H{sup −} ion source is operated with a pulsed 2-MHz RF (50-60 kW) to produce the 1-ms long, ∼50 mA H{sup −} beams at 60 Hz. A continuous low power (∼300 W) 13.56-MHz RF plasma, which is initially ignited with a H{sub 2} pressure bump, serves as starter plasma for the pulsed high power 2-MHz RF discharges. To reduce the risk of plasma outages at lower H{sub 2} flow rates which is desired for improved performance of the following radio frequency quadrupole, the 13.56-MHz RF matching network was characterized over a broad range of its two tuning capacitors. The H-α line intensity of the 13.56-MHz RF plasma and the reflected power of the 13.56-MHz RF were mapped against the capacitor settings. Optimal tunes for the maximum H-α intensity are consistent with the optimal tunes for minimum reflected power. Low limits of the H{sub 2} flow rate not causing plasma outages were explored within the range of the map. A tune region that allows lower H{sub 2} flow rate has been identified, which differs from the optimal tune for global minimum reflected power that was mostly used in the past.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Ultrafast Capabilities for X-ray Free-Electron Lasers at the Linac Coherent Light source

The ability to produce ultra-short, high-brightness X-ray pulses is revolutionizing the field of ultra-fast X-ray spectroscopy. Free electron laser (FEL) facilities are driving this revolution, but unique aspects of the FEL process make the required characterization and use of the pulses challenging. In this paper, we describe a number of developments in the generation of ultra-short X-ray FEL pulses, and the concomitant progress in the experimental capabilities necessary for their characterization and use at the Linac Coherent Light Source. This includes the development of sub-femtosecond hard and soft X-ray pulses, along with ultra-fast characterization techniques for these pulses. We also describe improved techniques for optical cross-correlation as needed to address the persistent challenge of external optical laser synchronization with these ultra-short X-ray pulses.

Coffee, Ryan N↗

Microwave plasma source operating with atmospheric pressure air-water mixtures

The overall performance of a surface wave driven air-water plasma source operating at atmospheric pressure and 2.45 GHz has been analyzed. A 1D model previously developed has been improved in order to describe in detail the creation and loss processes of active species of interest. This model provides a complete characterization of the axial structure of the source, including the discharge and the afterglow zones. The main electron creation channel was found to be the associative ionization process N + O {yields} NO{sup +}+ e. The NO(X) relative density in the afterglow plasma jet ranges from 1.2% to 1.6% depending on power and water percentage, according to the model predictions and the measurements. Other types of species such as NO{sub 2} and nitrous acid HNO{sub 2} have also been detected by mass and Fourier Transform Infrared spectroscopy. The relative population density of O({sup 3}P) ground state atoms increases from 8% to 10% in the discharge zone when the input microwave power increases from 200 to 400 W and the water percentage from 1% to 10%. Furthermore, high densities of O{sub 2}(a{sup 1}{Delta}{sub g}) singlet delta oxygen molecules and OH radicals (1% and 5%, respectively) can be achieved in the discharge zone. In the late afterglow the O{sub 2}(a{sup 1}{Delta}{sub g}) density is about 0.1% of the total density. This plasma source has a flexible operation and potential for channeling the energy in ways that maximize the density of active species of interest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cardinal: Seismic and Geoacoustic Array Processing

Data collected via seismic and infrasound array deployments are leveraged in the geosciences to detect and characterize a myriad of natural and anthropogenic sources. These deployments consist of numerous sensors placed in a predetermined configuration to amplify signal strength and improve the efficacy of array processing techniques used to measure signal directionality and waveform coherence. High‐fidelity feature extraction is often predicated on interstation distance as well as the frequency content and wavelength of an incident signal. Numerous array processing softwares analyze data in sequential frequency bands to obtain a more detailed characterization of a signal. However, current algorithms are limited in their ability to determine optimal array configuration for each band. We introduce an open‐source Python code, called Cardinal, to process seismic and infrasound array data in discretized time–frequency space with the option of applying an adaptive array design to determine optimal subarray configuration for each frequency band. To reduce computational time, the array processing step can be run in parallel using multithreading. Furthermore, the software has the capability to aggregate array processing results from different time–frequency pixels to produce separate sets of detections, or families, with added utility via the application of an adaptive semblance threshold, which aids in isolating signals‐of‐interest from coherent background noise. Upon appropriate configuration, Cardinal exhibits the potential to combine distinct seismic and infrasound phases into separate families.

Adaptive Array↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Periodic trends in gas–phase oxidation and hydrogenation reactions of lanthanides and 5d transition metal cations

Of the many publications coming from the laboratory of Diethard K. Bohme, among the most valuable were the surveys of reactivity throughout the periodic table as studied using selected ion flow tube (SIFT) mass spectrometry. In all cases, quantitative rate constants at 295 K and 0.35 Torr of He were obtained for metal cations generated by an inductively coupled plasma (ICP). This source creates ions at a temperature characterized as 5500 K. Here, it was believed that radiative relaxation and interactions with the flow gases would rapidly deplete most excited electronic states of the metal cations, although this is unknown

transition metals↗

A Tracer Study on sCO2 Corrosion with Multiple Oxygen-Bearing Impurities

Abstract Several modern power production systems utilize supercritical CO 2 (sCO 2 ), which can contain O 2 and H 2 O as impurities. These impurities may degrade the compatibility of structural alloys through accelerated oxidation. However, it remains unclear which of these impurities plays a bigger role in high-temperature reactions taking place in sCO 2 . In this study, various model and commercial Fe‐ and Ni‐based alloys were exposed in 300 bar sCO 2 at 750 °C to low levels (50 ppm) of O 2 and H 2 O for 1,000 h. 18 O-enriched water was used to enable the identification of the oxygen source in the post-exposure characterization of the samples. However, oxygen from the water did not accumulate in the scale, which consisted of Cr 2 O 3 in the cases where a protective oxide formed. A 2wt.% Ti addition to a Ni-22%Cr model alloy resulted in the formation of thicker oxides in sCO 2 , while a 1wt.% Al addition reduced the scale thickness. A synergistic effect of both Al and Ti additions resulted in an even thicker oxide than what was formed solely by Ti, similar to observations for Ni-based alloy 282.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗