Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Satellite Snow-Cover Mapping: A Brief Review

Satellite snow mapping has been accomplished since 1966, initially using data from the reflective part of the electromagnetic spectrum, and now also employing data from the microwave part of the spectrum. Visible and near-infrared sensors can provide excellent spatial resolution from space enabling detailed snow mapping. When digital elevation models are also used, snow mapping can provide realistic measurements of snow extent even in mountainous areas. Passive-microwave satellite data permit global snow cover to be mapped on a near-daily basis and estimates of snow depth to be made, but with relatively poor spatial resolution (approximately 25 km). Dense forest cover limits both techniques and optical remote sensing is limited further by cloudcover conditions. Satellite remote sensing of snow cover with imaging radars is still in the early stages of research, but shows promise at least for mapping wet or melting snow using C-band (5.3 GHz) synthetic aperture radar (SAR) data. Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS) data beginning with the launch of the first EOS platform in 1998. Digital maps will be produced that will provide daily, and maximum weekly global snow, sea ice and lake ice cover at 1-km spatial resolution. Statistics will be generated on the extent and persistence of snow or ice cover in each pixel for each weekly map, cloudcover permitting. It will also be possible to generate snow- and ice-cover maps using MODIS data at 250- and 500-m resolution, and to study and map snow and ice characteristics such as albedo. been under development. Passive-microwave data offer the potential for determining not only snow cover, but snow water equivalent, depth and wetness under all sky conditions. A number of algorithms have been developed to utilize passive-microwave brightness temperatures to provide information on snow cover and water equivalent. The variability of vegetative Algorithms are being developed to map global snow and ice cover using Earth Algorithms to map global snow cover using passive-microwave data have also cover and of snow grain size, globally, limits the utility of a single algorithm to map global snow cover.

Hall, Dorothy K.↗

Assessing the capability of different satellite observing configurations to resolve the distribution of methane emissions at kilometer scales

Anthropogenic methane emissions originate from a large number of fine-scale and often transient point sources. Satellite observations of atmospheric methane columns are an attractive approach for monitoring these emissions but have limitations from instrument precision, pixel resolution, and measurement frequency. Dense observations will soon be available in both low-Earth and geostationary orbits, but the extent to which they can provide fine-scale information on methane sources has yet to be explored. Here we present an observation system simulation experiment (OSSE) to assess the capabilities of different satellite observing system configurations. We conduct a 1-week WRF-STILT simulation to generate methane column footprints at 1.3 × 1.3 km 2 spatial resolution and hourly temporal resolution over a 290 × 235 km 2 domain in the Barnett Shale, a major oil and gas field in Texas with a large number of point sources. We sub-sample these footprints to match the observing characteristics of the recently launched TROPOMI instrument (7 × 7 km 2 pixels, 11 ppb precision, daily frequency), the planned GeoCARB instrument (2.7 × 3.0 km 2 pixels, 4 ppb precision, nominal twice-daily frequency), and other proposed observing configurations. The information content of the various observing systems is evaluated using the Fisher information matrix and its eigenvalues. We find that a week of TROPOMI observations should provide information on temporally invariant emissions at ~30 km spatial resolution. GeoCARB should provide information available on temporally invariant emissions ~2–7 km spatial resolution depending on sampling frequency (hourly to daily). Improvements to the instrument precision yield greater increases in information content than improved sampling frequency. A precision better than 6 ppb is critical for GeoCARB to achieve fine resolution of emissions. Transient emissions would be missed with either TROPOMI or GeoCARB. An aspirational high-resolution geostationary instrument with 1.3 × 1.3 km 2 pixel resolution, hourly return time, and 1 ppb precision would effectively constrain the temporally invariant emissions in the Barnett Shale at the kilometer scale and provide some information on hourly variability of sources.

54 ENVIRONMENTAL SCIENCES↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor system play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. Nonetheless, challenges emerge as distances grow due to signal attenuation and noise interference resulting in measurement errors. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond 10’s of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. This approach proves particularly advantageous in BOTDA systems, where accurate measurement of Brillouin scattering signals is paramount for long-range sensing, while concurrently safeguarding high spatial resolutions. In summary, this research has shown a holistic exploration of extending BOTDA's distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

Calibration and optimization of proportional counter modules using Garfield

Prototypes of radiation detector arrays used for charged-particle radiography require iniliol calibration to correlate the distribution of electron arrival time to the particle track locations. This step is crucial to obtaining the spatial resolution necessary to separate particle tracks traversing the individual proportional counters in the arrays. Our past attempts to use cosmic rays alone for the initial calibration have fallen short of obtaining the desired resolution due to the insufficient cosmic ray flux to provide the necessary number of particle tracks. A theoretical relation between electron drift time and radial drift distance is obtained with Garfield, a CERN gas detector simulation program. This relation is then used as an effective starting point for the initial calibration and results in a shorter calibration period and improved spatial resolution of the detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Terra and Aqua MODIS Intercomparison Using LEO-GEO Double Difference Method

The Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Terra and Aqua satellites havesuccessfully operated since their launch in 1999 and in 2002, providing more than 18 and 16 years ofcontinuous global observations, respectively. The inter-comparison between the two MODIS instruments can bevery supportive for the instrument calibration and uncertainty assessment. Aqua and Terra MODIS have almostidentical relative spectral response, spatial resolution, and dynamic range for each band. Therefore, a sitedependent correction for a sensor spectral band pair is not necessary for their comparison. However, Terra is inthe morning orbit with an equator crossing time of 10:30 am, and Aqua is in the afternoon orbit with equatorcrossing time of 1:30 pm. Consequently, there is a dearth of simultaneous nadir overpasses (SNOs)between the two satellites. Major challenges in cross-sensor comparison of instruments on different satellitesinclude differences in observation time, solar angle, and view angle over selected pseudo-invariant sites.In this work, the inter-comparisons of thermal emissive bands are performed over a pseudo-invariant target,using the observations from a sensor onboard a geostationary satellite as a bridge. Himawari8 was launched onOctober 7, 2014. The Advanced Himawari Imager (AHI) onboard Himawari8 can be used as a reference tobridge the comparison between Terra and Aqua MODIS. AHI has 16 channels; with spatial resolutions from 0.5km to 2 km at nadir and produces a full disk observations every 10 minutes. The band spectral coveragematchup, comparable spatial resolution and near-simultaneous observation between MODIS and AHI providefeasibility to implement a double difference method. This comparison method minimizes the impact of thedifference in observation time and solar angle. The comparison results will be used as an assessment for MODISinstrument calibration and will be helpful for future enhancement of the L1B product.

Himawari8↗

Probing coherence in nanoscale energy transport with high spatial-temporal resolution. Final Technical Report for DOE Award Number DE-SC0019244

The overarching goal of this project is to understand how the phase coherence of phonons and the interaction of phonons with other microscopic degrees of freedom in nanomaterials, such as 2D materials, can affect the energy transport properties and eventually lead to control of energy transport by manipulating phonon interference and phonon scatterings. On the computational side, we are developing and applying first-principles methods to study emerging phonon properties in nanomaterials, including coherent phonons, resonant bonding and gate-tunable phonon-electron scatterings, which hold the promise of enabling significant tunability of energy transport processes with external fields for a wide range of applications. On the experimental side, we are developing ultrafast transient grating spectroscopy and scanning ultrafast electron microscopy (SUEM) to directly probe the coherent phonon transport and phonon-electron interaction processes in nanomaterials with high combined spatial-temporal resolutions. This program will not only provide new insights into the microscopic transport and interaction processes of fundamental energy carriers, but also open new venue towards energy-relevant applications such as thermal switches and coherent energy harvesters.

42 ENGINEERING↗

Development of Thin Gap GEM-µRWELL Hybrid Detectors at Jefferson Lab

Over the past few decades, Micro Pattern Gaseous Detector (MPGD) technologies have been increasingly adopted as tracking detector options in High Energy and Nuclear Physics experiments thanks to their good spatial resolution, high-rate capability, stability and more importantly their ability for large area coverage at a relatively low cost compared to the alternative. The thin gap GEM-µRWELL hybrid detector is the latest addition to the MPGD family, that was introduced to vastly improve the spatial resolution capability of gaseous trackers when deployed in the barrel region to cover large angular acceptance of the central tracker in a collider experiment. In this talk, I will re-introduce the concept and motivation for the development of thin gap GEM-µRWELL hybrid technology with an emphasis on the initial studies that establish the proof-of-concept of the technology. I will then discuss the more recent results from latest beam test campaign at Jefferson Lab in May 2025 to study detector efficiency performance with various gas mixtures. I will also briefly present the ongoing activities to develop large area thin gap GEM-µRWELL tracking detectors for the ePIC experiment of the future Electron Ion Collider as well as the exploration of the technology to provide large area tracking options to the muon system of experiments at a future Higgs Factory Collider such as the FCC-ee for example. Finally, I will conclude with some perspectives on new ideas under exploration to develop the next generation of thin gap MPGD technologies with enhanced timing and spatial resolution capabilities

Gnanvo, Kondo [Thomas Jefferson National Accelerat↗

Macro vs. Micro: Relating the Spectral Properties of Vesta and the HED Meteorite

We present the main results obtained comparing the visible-near infrared (VIS-NIR) spectra Vesta s surface with howardites, eucrites, diogenites (HED). HEDs are commonly associated with Vesta s composition based on spectral similarities. Because of such association, much effort is being made to merge the information from HEDs as well as Vestoids - with that from Vesta to characterize the lithologic diversity of the surface of this asteroid and to infer clues regarding its thermal history. However, while the HEDs are a class of meteorites well studied in the laboratory, the only spectral data available for Vesta until now were telescopic observations which are limited in terms of observation conditions, spatial resolution and Signal to Noise Ratio. The Dawn spacecraft, orbiting around Vesta since July 2011, is performing detailed observations of this body and thus improving our knowledge of its properties. Dawn s scientific payload includes an imaging spectrometer, VIR-MS, sensitive to the VIS-NIR spectral range. VIR-MS began acquiring spectra during the approach phase started in May 2011 and will continue its observations through July 2012 when the spacecraft will depart Vesta to travel to Ceres. The VIR-MS spatial resolution depends upon the mission phase (approach, survey, high altitude, low altitude). However, spectra acquired by VIR-MS have already exceeded the spatial resolution of ground-based telescopic observations, with resolution in the approach phase ranging from 2.5 up to 0.8 km/pixel. Moreover, the observations are uniformly distributed in latitude and longitude allowing us to have a global view of Vesta s crust spectral properties. Using the information provided by VIR spectra, we studied the distribution of the spectral heterogeneities on the surface and we used our findings to perform a comparison with HEDs spectra in the VIS-NIR spectral range searching for analogies and/or incompatibilities. In our analysis, we focused on a method to compare the results obtained at microscopic scale on HEDs samples and the one obtained at macroscopic scale on the surface of Vesta. Finally, we discuss our results in the context of vestan thermal history. The intent of this study is to improve our understanding of the connection between Vesta and the HED samples, which is one of the primary Dawn scientific objectives. This work is supported by an Italian Space Agency (ASI) grant and by NASA through the Dawn project and a Dawn at Vesta Participating Scientist grant.

Ammannito, E.↗

Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal MSI in Conjunction with Broad Coverage Spatially Resolved MS2 Increases Confidence in Both Molecular Identification and Localization

One critical aspect of mass spectrometry imaging (MSI) is the need to con?dently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit di?erent distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS2I, to con?dently annotate and One critical aspect of mass spectrometry imaging (MSI) is the need to con?dently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit di?erent distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS2I, to con?dently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria, and fungus. We found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in di?erentiating metabolite routes in complex systems.

Velickovic, Dusan↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Effects of Digitization and JPEG Compression on Land Cover Classification Using Astronaut-Acquired Orbital Photographs

Studies that utilize astronaut-acquired orbital photographs for visual or digital classification require high-quality data to ensure accuracy. The majority of images available must be digitized from film and electronically transferred to scientific users. This study examined the effect of scanning spatial resolution (1200, 2400 pixels per inch [21.2 and 10.6 microns/pixel]), scanning density range option (Auto, Full) and compression ratio (non-lossy [TIFF], and lossy JPEG 10:1, 46:1, 83:1) on digital classification results of an orbital photograph from the NASA - Johnson Space Center archive. Qualitative results suggested that 1200 ppi was acceptable for visual interpretive uses for major land cover types. Moreover, Auto scanning density range was superior to Full density range. Quantitative assessment of the processing steps indicated that, while 2400 ppi scanning spatial resolution resulted in more classified polygons as well as a substantially greater proportion of polygons < 0.2 ha, overall agreement between 1200 ppi and 2400 ppi was quite high. JPEG compression up to approximately 46:1 also did not appear to have a major impact on quantitative classification characteristics. We conclude that both 1200 and 2400 ppi scanning resolutions are acceptable options for this level of land cover classification, as well as a compression ratio at or below approximately 46:1. Auto range density should always be used during scanning because it acquires more of the information from the film. The particular combination of scanning spatial resolution and compression level will require a case-by-case decision and will depend upon memory capabilities, analytical objectives and the spatial properties of the objects in the image.

Robinson, Julie A.↗

Single-Molecule Interfacial Electron Transfer

Interfacial electron transfer (ET) plays an important role in many chemical and biological processes. Specifically, interfacial ET in TiO 2 -based systems is important to solar energy technology, catalysis, and environmental remediation technology. However, the microscopic mechanism of interfacial ET is not well understood with regard to atomic surface structure, molecular structure, bonding, orientation, and motion. In this project, we used two complementary methodologies; single-molecule fluorescence spectroscopy, and scanning-tunneling microscopy and spectroscopy (STM and STS) to address this scientific need. The goal of this project was to integrate these techniques and measure the molecular dependence of ET between adsorbed molecules and TiO 2 semiconductor surfaces and the ET induced reactions such as the splitting of water. The scanning probe techniques, STM and STS, are capable of providing the highest spatial resolution but not easily time-resolved data. Single-molecule fluorescence spectroscopy is capable of good time resolution but requires further development to match the spatial resolution of the STM. The integrated approach involving Peter Lu at Bowling Green State University (BGSU) and Wilson Ho at the University of California, Irvine (UC Irvine) produced methods for time and spatially resolved chemical imaging of interfacial electron transfer dynamics and photocatalytic reactions. An integral aspect of the joint research was a significant exchange of graduate students to work at the two institutions. This project bridged complementary approaches to investigate a set of common problems by working with the same molecules on a variety of solid surfaces, but using appropriate techniques to probe under ambient (BGSU) and ultrahigh vacuum (UCI) conditions. The molecular level understanding of the fundamental interfacial electron transfer processes obtained in this joint project will be important for developing efficient light harvesting, solar energy conversion, and broadly applicable to problems in interface chemistry and surface physics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Two-dimensional maps of the infrared-to-radio ratio in spiral galaxies

We have produced two-dimensional maps of the intensity ratio Q(sub 60) of 60 micron infrared to 20 cm radio continuum emission, for a set of 25 nearby galaxies, mostly spirals. The ratio maps were obtained from infrared images made using Infrared Astronomical Satellite (IRAS) data with the Maximum Correlation Method, and radio images made using VLA data. Before taking the ratio, the radio images were processed so as to have the same resolution properties as the infrared images; the final spatial resolution in all cases is approximately 1 min, corresponding to 1-2 kpc for most galaxies. These images allow us to study the variations for the Q(sub 60) ratio with unprecedented spatial resolution, and thus represents a major improvement over earlier work. Our new high-resolution maps confirm the slow decrease of Q(sub 60) with increasing radial distance from the nucleus, but show additional structure which is probably associated with separate sites of active star formation in the spiral arms. The maps show Q(sub 60) to be more closely related to infrared surface brightness than to the radial distance in the galaxy disk. We expect that the results will provide improved constraints on the evolution (diffusion, decay and escape) of cosmic-ray electrons in the magnetic field of the disks.

Marsh, Kenneth A.↗

Advances in Performance of Microchannel Plate Detectors for HEDP Diagnostics

In recent years, a team from NSTec and SNL has built a unique capability to develop microchannel plate (MCP)?based framing x-ray cameras for HEDP diagnostics. At the SNL Z facility, multistrip MCP detectors to record up to eight channels are employed in 2-D, sub-nanosecond time-resolved imaging and time- and space-resolved spectroscopy diagnostics. Progressively more stringent technical temporal resolution and response uniformity requirements have necessitated a systematic design approach based on iterative modeling of the MCP using inputs from electrical circuit characterization. An inherently large exponential dependence in MCP gain, V{sup 11.5}, has mandated a firm understanding of the applied voltage pulse shape propagating across the strip. We pioneered direct measurements of the propagating waveform using a Picoprobe{reg_sign} and developed a Monte Carlo code to simulate MCP response to compare against test measurements. This scheme is shown in Figure 1. The simulation detailed a physical model of the cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Using this design approach, we began to characterize the newly developed second-generation detector (H-CA-65) by using a Manson x-ray source to evaluate the following DC characteristics: MCP sensitivity as a function of bias voltage, flat-field uniformity and spatial resolution, and variation of spatial resolution and sensitivity as a function of phosphor bias voltage. Dynamic performance and temporal response were obtained by using an NSTec short-pulse laser to measure optical gate profiles, saturation, and dynamic range. These data were processed and combined to obtain the gain variation and gate profiles for any position along an MCP strip. Typical position-sensitive gate profiles of the detector are shown in Figure 2. The measured gate profiles for the latest design have shown excellent agreement with Monte Carlo simulations. This modeling success provides us with a powerful tool for designing and optimizing MCP detectors that will meet specified requirements. For example, the pulse-forming network (PFN) pulse width can be chosen based on Monte Carlo simulation to achieve the shortest gate profiles without loss of significant gain. In Figure 2, a 150-ps FWHM gate profile was determined to be the inherent response time of our detector, This is close to the transit time of the electrons inside the MCP. The difference between design and measured performance of the H-CA-65 is within experimental errors. The most exciting outcome from the characterize/model process is that MCP gain uniformity can be achieved by adjusting output circuit impedance and judiciously selecting an appropriately wide voltage pulse waveform to drive the MCP strip. The combination of impedance, reflection ratio, and pulse shape/width can be optimized to provide a uniform pulse to propagate across a strip. Figure 3 shows the sensitivity measured across an MCP strip for an old-style SNL detector and the H-CA-65. The H-CA-65's uniformity is 30% or better for a strip driven by a 300-ps FWHM PFN (yielding a 150-ps FWHM optical gate profile), compared to a factor of five or less for the old detector. For the time-resolved spectroscopy diagnostic at Z, gain uniformity across the strip is a much more critical criterion than a narrow optical gate. A gain uniformity of 10% along the MCP strip was achieved when driven by a 700-ps FWHM PFN (yielding a 250-ps FWHM optical gate), a two order of magnitude improvement. The developments that produced the H-CA-65, which are now part of our MCP design process, have reduced product cost and the time it takes to develop and characterize the new MCP detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the accuracy of simulations of turbulence

The widely recognized issue of adequate spatial resolution in numerical simulations of turbulence is studied in the context of two-dimensional magnetohydrodynamics. The familiar criterion that the dissipation scale should be resolved enables accurate computation of the spectrum, but fails for precise determination of higher-order statistical quantities. Examination of two straightforward diagnostics, the maximum of the kurtosis and the scale-dependent kurtosis, enables the development of simple tests for assessing adequacy of spatial resolution. The efficacy of the tests is confirmed by examining a sample problem, the distribution of magnetic reconnection rates in turbulence. Oversampling the Kolmogorov dissipation scale by a factor of 3 allows accurate computation of the kurtosis, the scale-dependent kurtosis, and the reconnection rates. These tests may provide useful guidance for resolution requirements in many plasma computations involving turbulence and reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kelvin Probe Force Microscopy for High-Resolution Imaging of Hydrogen in Steel and Aluminum Alloys

SRNL is working with Sandia NL, Pacific Northwest NL and Oak Ridge NL in the H-Mat consortium with the objective of developing materials with a higher resistance to hydrogen attack. Understanding the mechanism of hydrogen interactions in metal alloys is continually a topic of interest for applications which involve the long-term storage of hydrogen. Atomic hydrogen segregates to regions of extended defects, such as grain and phase boundaries, and can cause stress and premature cracking through a process known as hydrogen embrittlement. Advanced microstructural imaging techniques, with minimal sample preparation needs, that are capable of resolving hydrogen segregation at the nanometer scale is needed. Current imaging technologies to aid in understanding the effects of hydrogen in metals involve primarily fractography after mechanical testing. Hydrogen segregated at the surface and particularly at surface defect sites changes the local work function of the material. This can be measured by Kelvin Probe Force Microscopy, KPFM, a variant of atomic force microscopy (AFM). KPFM produces surface potential images and is capable of measuring the local change in work function of surfaces with very high spatial resolution. The spatial resolution of KPFM is optimally ~5 nm, yielding very high hydrogen concentration/microstructure coloration capabilities. By locating the presence of hydrogen and its relationship with extended defects, it may be possible to develop microstructures less susceptible to hydrogen embrittlement. The objective of this effort is to assess the utility of KPFM to determine the H 2 concentration profiles surrounding complex microstructural features in high strength steel and aluminum alloys subjected to high pressure hydrogen exposure.

08 HYDROGEN↗

Remote Sensing Requirements Development: A Simulation-Based Approach

Earth science research and application requirements for multispectral data have often been driven by currently available remote sensing technology. Few parametric studies exist that specify data required for certain applications. Consequently, data requirements are often defined based on the best data available or on what has worked successfully in the past. Since properties such as spatial resolution, swath width, spectral bands, signal-to-noise ratio (SNR), data quantization and band-to-band registration drive sensor platform and spacecraft system architecture and cost, analysis of these criteria is important to optimize system design objectively. Remote sensing data requirements are also linked to calibration and characterization methods. Parameters such as spatial resolution, radiometric accuracy and geopositional accuracy affect the complexity and cost of calibration methods. However, few studies have quantified the true accuracies required for specific problems. As calibration methods and standards are proposed, it is important that they be tied to well-known data requirements. The Application Research Toolbox (ART) developed at the John C. Stennis Space Center provides a simulation-based method for multispectral data requirements development. The ART produces simulated datasets from hyperspectral data through band synthesis. Parameters such as spectral band shape and width, SNR, data quantization, spatial resolution and band-to-band registration can be varied to create many different simulated data products. Simulated data utility can then be assessed for different applications so that requirements can be better understood.

Zanoni, Vicki↗