Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Development of a Multi-Gas Microsensor Array for the Exploration Portable Life Support System

The Portable Life Support System (PLSS) of the Exploration Extravehicular Mobility Unit (xEMU) requires sensors capable of measuring the major constituents of the gas stream. These major constituents include oxygen, carbon dioxide, and water vapor. The sensors must operate across a wide range of flow and pressure conditions and introduce very low pressure drop in the ventilation loop. The sensors must operate with low power and occupy a small volume. This paper reports the development of a compact, low power, multi-parameter astronaut life support sensor (M-PALSS). M-PALSS consists of an array of low-power chemical microsensors for oxygen, carbon dioxide, water vapor, and pressure. M-PALSS includes custom electronics to control the sensors and is packaged in a custom housing that meets the volume and shape requirements for service in the PLSS.

James Makel↗

Validation of Two-phase Flow Modeling Techniques in Loci-Stream using Axial Jet Pressure Control and Autogenous Pressurization Experiment

Improvements to computational fluid dynamics modeling of cryogenic fluid management operations are presented with experimental validations. Modeling improvements includes utilizing improved delayed detaches eddy simulation to more effectively model turbulence compared to the Reynolds-averaged Navier Stokes modeling, modeling temperature dependent tank solid properties to capture large variation in thermodynamic properties at cryogenic conditions, modeling real gas equation of state for hydrogen instead of ideal gas behavior, and an on-going effort to improve interface turbulence transport for the volume of fluid method. Two flight-scale ground tests, five K-site tank axial jet pressure control experiments and an Engineering Design Unit tank autogenous pressurization experiment are validated and show the effectiveness of the improved modeling techniques. The successful validation establishes further trust in these models for flight project support and provides a pathway for maturation of in-development interface turbulence damping model for the volume of fluid method for more generalized applications.

CFD↗

Validation of Two-Phase Flow Modeling Techniques in Loci-Stream Using Axial Jet Pressure Control and Autogenous Pressurization Experiments

Improvements to computational fluid dynamics modeling of cryogenic fluid management operations are presented with experimental validations. Modeling improvements includes utilizing improved delayed detaches eddy simulation to more effectively model turbulence compared to the Reynolds-averaged Navier Stokes modeling, modeling temperature dependent tank solid properties to capture large variation in thermodynamic properties at cryogenic conditions, modeling real gas equation of state for hydrogen instead of ideal gas behavior, and an on-going effort to improve interface turbulence transport for the volume of fluid method. Two flight-scale ground tests, five K-site tank axial jet pressure control experiments and an Engineering Design Unit tank autogenous pressurization experiment are validated and show the effectiveness of the improved modeling techniques. The successful validation establishes further trust in these models for flight project support and provides a pathway for maturation of in-development interface turbulence damping model for the volume of fluid method for more generalized applications.

CFD↗

PILOT-SCALE TEST RESULTS OF A THIN FILM EVAPORATOR SYSTEM FOR MANAGEMENT OF LIQUID HIGH-LEVEL WASTES AT THE HANFORD SITE WASHINGTON USA -11364

A modular, transportable evaporator system, using thin film evaporative technology, is planned for deployment at the Hanford radioactive waste storage tank complex. This technology, herein referred to as a wiped film evaporator (WFE), will be located at grade level above an underground storage tank to receive pumped liquids, concentrate the liquid stream from 1.1 specific gravity to approximately 1.4 and then return the concentrated solution back into the tank. Water is removed by evaporation at an internal heated drum surface exposed to high vacuum. The condensed water stream will be shipped to the site effluent treatment facility for final disposal. This operation provides significant risk mitigation to failure of the aging 242-A Evaporator facility; the only operating evaporative system at Hanford maximizing waste storage. This technology is being implemented through a development and deployment project by the tank farm operating contractor, Washington River Protection Solutions (WRPS), for the Office of River Protection/Department of Energy (ORPIDOE), through Columbia Energy and Environmental Services, Inc. (Columbia Energy). The project will finalize technology maturity and install a system at one of the double-shell tank farms. This paper summarizes results of a pilot-scale test program conducted during calendar year 2010 as part of the ongoing technology maturation development scope for the WFE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrahigh heat flux plasma-facing components for magnetic fusion energy

Sandia and Ultramet partnered to design and test refractory metal plasma-facing components and heat exchangers for advanced, high-temperature power conversion systems. These devices consisted of high-temperature helium-to-helium and lithium-to-helium heat exchangers that operate with high efficiency due to the porous foam inserts used in the gas stream, which promote turbulence and provide extended surface area for enhanced convection. Single- and multi-channel helium panels and the Li-He heat exchanger were fabricated from either pure molybdenum, TZM, or tungsten. The design was carried out through an Ultramet subcontractor. The flow path was carefully tailored to minimize the pressure drop while maximizing the heat transfer. The single- and multi-channel helium panels were tested at Sandia's PMTF using an electron beam system and the closed helium flow loop. In 2006, a single-channel tungsten tube was successfully tested to an average heat flux of 14 MW/m{sup 2} with a localized peak of 22 MW/m{sup 2} along the axial centerline at the outer radius. Under this CRADA, multiple square-channel molybdenum components were successfully tested to heat flux levels approaching 8.5 MW/m{sup 2}. The three multi-channel prototypes experienced mechanical failure due to issues related to the design of the large unsupported span of the heated faceplates in combination with prototype material and braze selection. The Li-He heat exchanger was both designed and partially tested at the PMTF for helium and lithium flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resource Characterization to Estimate Potential for Electricity Co-Production at Blackburn Oil Field, Nevada

The U.S. Department of Energy estimates that an annual average of 25 billion barrels of hot water are produced from oil and gas wells within the United States. The thermal energy available in the co-produced water stream is usually discarded, as the produced waters are considered an inconvenience by the operators and are disposed of using injection wells. However, utilizing organic Rankine cycle (ORC) generators, a vast amount of thermal energy can be captured and converted into electricity (albeit at relatively low efficiency due to the low temperatures). The National Renewable Energy Laboratory (NREL), in collaboration with Transitional Energy and Grant Canyon Oil & Gas, evaluated the feasibility of geothermal co-production of electricity by utilizing existing oil wells in Blackburn oil field in Nevada. The once prolific Blackburn oil field is located in Pine Valley, approximately 45 miles east-southeast of Elko, Nevada. Currently, the wells targeting the highly fractured Devonian Nevada dolomite reservoir are operating at a water cut ratio of more than 99%, with individual fluid (oil and water) production rates reaching 7.4 L/s (4,021 BBL/day). Analysis of publicly available data showed that the combination of the suitable wells' maximum historical production rates reached 22.90 L/s. The production from these wells occurs naturally and the wells are choked (and even shut down) by the operator to mitigate excessive water production, indicating a strong reservoir recharge and future opportunity to increase the water production for geothermal electricity generation. The main goal of this study was to evaluate the productivity of the existing wells, the performance of the reservoir, the surface network, and the operational constraints in order to achieve 1 MWe of electricity production from the field's water production. Utilizing the GEOPHIRES tool, we have determined that a twofold to threefold increase in the total fluid production, compared to the historical production under artificial restraint (choke), is required to reach a 1-MWe net target output for a low-temperature ORC system with air-cooled condensers. Lower flow rates would be required when utilizing water-based condensers instead of air-cooled condensers. However, that would require a constant supply of cold water, which may be challenging given the arid environment of the project site.

Blackburn↗

APPLICATION OF A THIN FILM EVAPORATOR SYSTEM FOR MANAGEMENT OF LIQUID HIGH-LEVEL WASTES AT HANFORD

A modular, transportable evaporator system, using thin film evaporative technology, is planned for deployment at the Hanford radioactive waste storage tank complex. This technology, herein referred to as a wiped film evaporator (WFE), will be located at grade level above an underground storage tank to receive pumped liquids, concentrate the liquid stream from 1.1 specific gravity to approximately 1.4 and then return the concentrated solution back into the tank. Water is removed by evaporation at an internal heated drum surface exposed to high vacuum. The condensed water stream will be shipped to the site effluent treatment facility for final disposal. This operation provides significant risk mitigation to failure of the aging 242-A Evaporator facility; the only operating evaporative system at Hanford maximizing waste storage. This technology is being implemented through a development and deployment project by the tank farm operating contractor, Washington River Protection Solutions (WRPS), for the Office of River Protection/Department of Energy (ORP/DOE), through Columbia Energy & Environmental Services, Inc. (Columbia Energy). The project will finalize technology maturity and install a system at one of the double-shell tank farms. This paper discusses results of pre-project pilot-scale testing by Columbia Energy and ongoing technology maturation development scope through fiscal year 2012, including planned additional pilot-scale and full-scale simulant testing and operation with actual radioactive tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Marshall Space Flight Center solid waste characterization and recycling improvement study: General office and laboratory waste, scrap metal, office and flight surplus

The primary objectives of the study were to characterize the solid waste stream for MSFC facilities in Huntsville, Alabama, and to evaluate their present recycling program. The purpose of the study was to determine if improvements could be made in terms of increasing quantities of the present commodities collected, adding more recyclables to the program, and streamlining or improving operational efficiency. In conducting the study, various elements were implemented. These included sampling and sorting representative samples of the waste stream; visually inspecting each refuse bin, recycle bin, and roll-off; interviewing employees and recycling coordinators of other companies; touring local material recycling facilities; contacting experts in the field; and performing a literature search.

Eley, Michael H.↗

Identification of Waste Streams and Chemicals of Concern for CNL's Near Surface Disposal Facility - 18057

Canadian Nuclear Laboratories (CNL) has a 70-year history in nuclear Research and Development (R and D) and the original support to the Canada Deuterium Uranium (Candu) reactor fleet. The present laboratory and operations include multiple facilities including reactors, laboratories, and buildings at various locations in Canada. The onsite facilities produced and still produce numerous and complex waste streams which have historically been placed in waste storage areas at their sites. CNL has completed the design and is in the process of licensing a Near Surface Disposal Facility (NSDF) for CNL low level waste (LLW). The current plan, pending regulatory approvals would complete construction and commissioning in 2021. CNL has identified the waste streams that are proposed to be disposed of to determine which may or may not require treatment prior to disposal and the Chemicals of Concern (COCs) that require identification and control to protect the facility, workers, public and the environment. CNL gathered the information into a Waste Stream spreadsheet that identifies the waste. Each waste stream was then evaluated as to whether or not it should meet the NSDF Waste Acceptance Criteria (WAC), and if not, which treatment technologies would be appropriate to make it ready for disposal. Understanding the hazards and associated COCs of the waste is required to safely dispose the waste. COCs present at Chalk River Laboratories (CRL) need to be identified and subsequently evaluated to determine if they pose any type of risk due to their hazardous properties or quantities. The COC data base was modified into a tool to assist waste generators. CNL has developed waste stream and COC data bases to support safe disposal of radioactive waste. Identification of waste streams and COCs for disposal is important for any disposal facility. The lessons learned by CNL as to what information is important and how to obtain the information would be useful to many facilities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a statistical model (tool) for classifying buried object detectability

To improve warfighter safety under changing requirements, assets must be adaptable and able to detect and mark buried hazards. Current GPR systems would benefit by improvements in speed, usability, and operational versatility to enhance operational effectiveness for all platforms and missions. Our sponsor requests that LLNL research GPR methodologies and approaches to allow for specific improvements to be made in those areas. MiRadar uses a novel multi-static array architecture coupled with tomographic processing to focus returned energy from the real (physical) and synthetic (motion-derived) apertures. 3D streaming movies of the subsurface are easily interpreted, slashing training times. Real-time processing codes enable imaging and operation three times faster; automated volumetric detection algorithms warn of possible hazards. In a two-week trial, multiple vehicle-mounted arrays and a new ultralightweight architecture on a small, unmanned aircraft system executed 498 runs, collecting over 400km of data on 13 preemplaced lanes containing 384 simulated buried threats.

42 ENGINEERING↗

Designing an autonomous environment for mission critical operation of the EUVE satellite

Since the launch of NASA's Extreme Ultraviolet Explorer (EUVE) satellite in 1992, there has only been a handful of occurrences that have warranted manual intervention in the EUVE Science Operations Center (ESOC). So, in an effort to reduce costs, the current environment is being redesigned to utilize a combination of off-the-shelf packages and recently developed artificial intelligence (AI) software to automate the monitoring of the science payload and ground systems. The successful implementation of systemic automation would allow the ESOC to evolve from a seven day/week, three shift operation, to a seven day/week one shift operation. First, it was necessary to identify all areas considered mission critical. These were defined as follows: (1) The telemetry stream must be monitored autonomously and anomalies identified. (2) Duty personnel must be automatically paged and informed of the occurrence of an anomaly. (3) The 'basic' state of the ground system must be assessed. (4) Monitors should check that the systems and processes needed to continue in a 'healthy' operational mode are working at all times. (5) Network loads should be monitored to ensure that they stay within established limits. (6) Connectivity to Goddard Space Flight Center (GSFC) systems should be monitored as well, not just for connectivity of the network itself but also for the ability to transfer files. (7) All necessary peripheral devices should be monitored. This would include the disks, routers, tape drives, printers, tape carousel, and power supplies. (8) System daemons such as the archival daemon, the Sybase server, the payload monitoring software, and any other necessary processes should be monitored to ensure that they are operational. (9) The monitoring system needs to be redundant so that the failure of a single machine will not paralyze the monitors. (10) Notification should be done by means of looking though a table of the pager numbers for current 'on call' personnel. The software should be capable of dialing out to notify, sending email, and producing error logs. (11) The system should have knowledge of when real-time passes and tape recorder dumps will occur and should know that these passes and data transmissions are successful. Once the design criteria were established, the design team split into two groups: one that addressed the tracking, commanding, and health and safety of the science payload and another group that addressed the ground systems and communications aspects of the overall system.

Abedini, Annadiana↗

Synthetic Calcium Carbonate Production by Carbon Dioxide (CO 2 ) Mineralization of Industrial Waste Brines

The global scale of CO 2 emission has crossed 36 B tons, and the United State represents 14% of the total emissions. In light of the high cost associated with current CO 2 capture processes ($60-to-150 per ton of CO 2 ), carbon capture and utilization (CCU), wherein CO 2 is converted to beneficial products, provides a pragmatic path to overcome the economic barrier for CO 2 emissions control. In particular, CO 2 mineralization offers an attractive route as it produces high-value mineral carbonates that sequester CO 2 in a stable form. For instance, fine precipitated calcium carbonate, a valuable product with unit price in the range of $230-280/t and a global market projected to reach 99 M tons in 2020, can be produced by capturing CO 2 within aqueous Ca 2+ solution. However, two critical challenges need to be overcome—(i) the need for costly processes such as electrolysis or addition of alkali hydroxides to maintain alkalinity during mineralization, and (ii) the geographic availability of Ca-rich solutions (or brines) which often renders efficient integration with power plants impractical. To simultaneously address these challenges, this project developed two novel routes to enable carbonate production based on efficient CO 2 mineralization. In one variation, the project developed a new alkaline carbonation process to capture CO 2 and produce calcite precipitates from coal ashes. Herein, coal ash is carbonated first in a sodium carbonate solution. The carbonation reaction produces sodium hydroxide and raises the solution pH. This high-pH hydroxide solution is then used for CO 2 capture, which converts the sodium hydroxide solution back to sodium carbonate to repeat the carbonation cycle. The carbonated ash residue is refined with a CO 2 pressure swing step to produce high-purity precipitated calcium carbonate. In another variation, Ca-rich produced water brine serves as the Ca-source to mineralize CO 2 . An H + /Na + ion-exchange cycle was designed to provision alkalinity during mineralization and regenerate the ion-exchange reagent in brines with high salinity. Ca-depleted brines can then be treated within a centralized water treatment facility. Both variations beneficially utilize reject streams—such as coal ashes and brines from oil and gas extraction or CO 2 storage operations—that are available at substantial quantities in the vicinity of coal power plants within the U.S. In addition to technology development, this project included techno-economic and life-cycle analysis to identify technically and economically appropriate solutions for power plants in different geographic locations. Taken together, the project provides a unique route to integrate CO 2 emissions control and waste handling/treatment for coal power plants, while producing a high-value product to offset the economic burden associated with waste management. The developed processes utilize post-desulfurization flue gas from coal-fired power plants as is. The CO 2 conversion reactions are performed in alkaline brines at ambient pressure from the flue gas, thereby minimizing the energy burden. By beneficiation of industrial waste streams with low energy input, the processes offers significant technical advantages in energy and CO 2 footprint over the current paradigm of precipitated calcium carbonate production, which involves calcination of limestone at processing temperatures in excess of 800 °C. Overall, this project developed viable CO 2 mineralization processes while strategically maximizing the economic benefit.

01 COAL, LIGNITE, AND PEAT↗

Impact of Fermentation-Derived Substrates on Hydrogen Production in Zero-Gap Microbial Electrolysis Cells

Zero-gap microbial electrolysis cells (MECs) represent a promising platform for hydrogen production from liquid waste streams due to reduced interelectrode spacing that lowers internal resistance and enhances mass transport. However, the performance and stability of zero-gap MECs treating chemically complex feedstocks remain insufficiently characterized. Here, we operated zero-gap MECs with real, unamended, corn stover dark fermentation effluent containing a wide range of organic substrates. The MECs fed fermentation effluent achieved a maximum current density of 24 A/m2 (15+-6 A/m2 over the cycle) and a hydrogen production rate of 75 L/L-d (42+-19 L/L-d over the cycle). The substrates were consumed at different rates, indicating substrate-selective utilization by the anodic microbial community. Acetate supported high and stable current generation, whereas ethanol, formate, lactate, and amino acids induced varying degrees of inhibition depending on their concentration. Residual sugars caused pronounced current fluctuations, consistent with ongoing fermentation and local pH changes. A diverse microbial community was crucial for efficiently utilizing complex organics and maximizing electrochemical performance. These results demonstrate how and to what extent substrate composition regulates zero-gap MEC performance and that microbial community and operational conditions can be leveraged to enhance performance. These novel findings provide practical guidance for achieving robust hydrogen recovery from chemically heterogeneous real liquid waste streams.

08 HYDROGEN↗

Pressure Dome for High-Pressure Electrolyzer

A high-strength, low-weight pressure vessel dome was designed specifically to house a high-pressure [2,000 psi (approx. = 13.8 MPa)] electrolyzer. In operation, the dome is filled with an inert gas pressurized to roughly 100 psi (approx. = 690 kPa) above the high, balanced pressure product oxygen and hydrogen gas streams. The inert gas acts to reduce the clamping load on electrolyzer stack tie bolts since the dome pressure acting axially inward helps offset the outward axial forces from the stack gas pressure. Likewise, radial and circumferential stresses on electrolyzer frames are minimized. Because the dome is operated at a higher pressure than the electrolyzer product gas, any external electrolyzer leak prevents oxygen or hydrogen from leaking into the dome. Instead the affected stack gas stream pressure rises detectably, thereby enabling a system shutdown. All electrical and fluid connections to the stack are made inside the pressure dome and require special plumbing and electrical dome interfaces for this to be accomplished. Further benefits of the dome are that it can act as a containment shield in the unlikely event of a catastrophic failure. Studies indicate that, for a given active area (and hence, cell ID), frame outside diameter must become ever larger to support stresses at higher operating pressures. This can lead to a large footprint and increased costs associated with thicker and/or larger diameter end-plates, tie-rods, and the frames themselves. One solution is to employ rings that fit snugly around the frame. This complicates stack assembly and is sometimes difficult to achieve in practice, as its success is strongly dependent on frame and ring tolerances, gas pressure, and operating temperature. A pressure dome permits an otherwise low-pressure stack to operate at higher pressures without growing the electrolyzer hardware. The pressure dome consists of two machined segments. An O-ring is placed in an O-ring groove in the flange of the bottom segment and is trapped by the flange on the top dome segment when these components are bolted together with high-strength bolts. The pressure dome has several unique features. It is made (to ASME Pressure Vessel guidelines) in a high-strength aluminum alloy with the strength of stainless steel and the weight benefits of aluminum. The flange of the upper dome portion contains specially machined flats for mounting the dome, and other flats dedicated to the special feedthroughs for electrical connections. A pressure dome can be increased in length to house larger stacks (more cells) of the same diameter with the simple addition of a cylindrical segment. To aid in dome assembly, two stainless steel rings are employed. One is used beneath the heads of the high-strength bolts in lieu of individual hardened washers, and another is used instead of individual nuts. Like electrolyzers could be operated at low or high pressures simply by operating the electrolyzer outside or inside a pressurized dome.

Norman, Timothy↗

FY24 Task 5: Leachate Disposition

Directly feeding sludge solids to the high-level waste (HLW) Waste Treatment Plant represents an alternative flowsheet seeking to initiate sludge processing as soon as possible. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration. These operations should be considered in the potential direct feed flowsheets to maximize waste feed loading, minimize HLW volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. Additionally, single-shell tank (SST) retrievals and waste transfers to double-shell tanks (DSTs) in a direct feed flowsheet would likely also benefit from some level of leaching, washing, and solids concentration in order to reduce DST space and mission duration. These operations could occur in a new facility or potentially in available DSTs. If washing and leaching are utilized, an effective disposition pathway for the wash water and leachate solutions are needed. Three target species that benefit significantly from leaching and washing are phosphate, fluoride and aluminum. Phosphate (PO 4 3- ) and fluoride (F - ) can contribute substantially to the amount of carrier fluid needed for dissolution, and the resulting volume of liquid generated. Disposition of this retrieval solution should be evaluated in order to prevent crystallization of these anions throughout system processing. Since there is a high probability that any retrieval solutions will be at or near their PO 4 3- and F - solubility limits, evaporation or blending with a high Na supernate (>3.5 M) is not recommended for the wash water streams without a method to remove precipitants prior to solution disposal. Additionally, aluminum present in the southeast quadrant of the Hanford site represents roughly 60% of the waste solids in the initial processing tanks. These aluminum solids are in the form of gibbsite (Al(OH) 3 ) and can pose significant challenges for processing due to the fast-settling times and high solids loading associated with these materials. Easily remediated by caustic addition to the solids, these wash solutions could be processed through crystalline silicotitanate (CST) ion exchange columns to prepare the supernate solutions for disposition. The current target for feed conditions to the Low Activity Waste (LAW) melter are waste streams that contain nominally 5-6 M Na. Fractions within the tanks contain upwards of 0.2 M phosphate and fluoride in solution at 3.5 M Na. Concentrating these solutions above 5 M Na would result in an exceedance of the solubility limits, and potential for uncontrolled precipitation of the phosphate and fluoride crystal material. The resulting crystalline salt material is typically sodium fluoride phosphate, also referred to as natrophosphate (Na 7 FPO 4 ·19H 2 O). Salt phases are of importance in tank waste due to their chemical reactivity, which can result in precipitation, dissolution, or transformation, impacting any downstream processes (Bolling et al. 2020, Russell, Snow, and Peterson 2010). Salt generation and precipitation could pose challenges by causing system plugging and melter corrosion if left in the supernate stream, or limit sodium molarity of the supernate that would be accepted without incident in waste operations. To understand the impact of this salt generation, the crystallization of natrophosphate in multiple simulant feed matrices was studied to understand the implications of various tank waste supernate chemistries. Three matrices were examined: high PO 4 3- /low F - , low PO 4 3- /high F - , and an average matrix. Subsequent testing was performed with the average matrix with the inclusion of CsNO 3 , and a final run with the average matrix including CsNO 3 and a 137 Cs spike for tracer purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selection of glasses in support of the Sludge Batch 9 variability study for coupled operation with the Salt Waste Processing Facility

Prior to the processing of Sludge Batch 9 (SB9) with Frit 803 at the Defense Waste Processing Facility (DWPF), assessments and experimental glass work were completed to support the qualification of SB9 coupled processing with streams from the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU). This previous work did not address coupled processing with streams from the Salt Waste Processing Facility (SWPF) because the Product Composition Control System (PCCS) models limited the TiO 2 concentration in glass to 2 weight percent (wt.%). These high activity streams from SWPF include monosodium titanate (MST) and sludge solids from the Sludge Solids Receipt Tank as well as Cs-containing strip effluent. The incorporation of these SWPF streams is expected to reach TiO2 concentrations in glass greater than 2 wt.% based on an MST addition of 0.4 g MST/L of salt solution. If double strike operation is required, then the MST addition is increased to 0.8 g MST/L of salt solution. Therefore, revisions to the models contained in PCCS were completed to allow the evaluation of glasses containing greater than 2 wt.% TiO 2 , but less than 6 wt.%. To support the implementation of the revised PCCS for SB9 – Frit 803 processing at DWPF prior to SWPF startup, the applicability of the new durability models for the SB9 variability study glasses was verified. Since the initial SB9 qualification for ARP-MCU coupled operation, additional Tank 40 analyses have been completed, which served as the basis for an updated projection of the SB9 blend composition in Tank 40. To identify a frit optimized for SB9 coupled operation with SWPF, the Savannah River National Laboratory (SRNL) performed a paper-study by utilizing Measurement Acceptance Region (MAR) assessments with DWPF PCCS. Based on these MAR assessment results, Frit 625 was recommended for processing both single and double MST strike scenarios. Savannah River Remediation (SRR) requested that SRNL perform a variability study with both Frit 803 and Frit 625 for SB9 coupled operation with SWPF. The objective of the variability study is to demonstrate that the Product Consistency Test (PCT) responses of the glasses are acceptable relative to the chemical durability of the Environmental Assessment (EA) reference glass and predictable by the current DWPF PCCS models for durability. This report documents the development of a test matrix that will support the variability study. To provide operational flexibility prior to SWPF startup, the predictability of glasses within the glass region for Frit 625-SB9 coupled operation with ARP-MCU was also confirmed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗