Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Temperature-Dependent Optical and Structural Properties of Chiral Two-Dimensional Hybrid Lead-Iodide Perovskites

Layered hybrid halide perovskites gain chirality via the incorporation of chiral organic cations in the spacer layer. These so-called chiral two-dimensional (2D) halide perovskites have attracted considerable interest recently for chiral optoelectronic, spintronic, and ferroelectric applications. However, the effect of temperature on these materials, especially how the structure changes with temperature and its impact on the chiral optoelectronic properties, remains an open question. Here, we study the effect of temperature change on chiral optoelectronic and structural properties through temperature-dependent circularly polarized photoluminescence (CPPL) microscopy and synchrotron powder X-ray diffraction as well as pair distribution function analysis to elucidate the intrinsic chiral optoelectronic and structural variations for R-, S-, and racemic-methylbenzylamine lead iodide. Here our results show that the temperature-induced band gap changes indicate a strong electron–phonon coupling compared to the thermal-induced lattice expansion in chiral 2D perovskites. From powder diffraction measurements, a monotonic lattice expansion is observed on heating with no structural phase transitions over 90–360 K detected for the three samples studied herein. Locally, a strongly anisotropic and even negative expansion in some components of the instantaneous Pb–I pair-distance distribution is suggestive of coupling between dynamical intralayer distortions and lattice expansion. This work provides insights into the fundamental understanding of the temperature effect on chiral optoelectronic and structural properties of chiral 2D perovskites, which can lead to new chiral materials design strategies for future chiral optoelectronic applications.

36 MATERIALS SCIENCE↗

System for improving measurement accuracy of transducer by measuring transducer temperature and resistance change using thermoelectric voltages

A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.

Anderson, Karl F.↗

Heat Flow on the U.S. Beaufort Margin, Arctic Ocean: Implications for Ocean Warming, Methane Hydrate Stability, and Regional Tectonics

The Arctic Ocean represents one of the last geological frontiers on Earth. The formation of the Arctic Ocean remains unclear, and although it is well understood that the Arctic surface temperature is warming at a rate approximately twice as fast as the rest of the Earth, it is unclear how deep Arctic Ocean temperatures are changing. Understanding whether deep Arctic Ocean water is warming is important, since it can lead to the breakdown and release of huge quantities of frozen methane molecules trapped below the Arctic seafloor, which can increase ocean acidity and destabilize the seafloor. To understand both Arctic Ocean temperature change and geologic evolution, we collected temperature measurements at 103 sites. These measurements tell us how temperature increases with depth below the seafloor and can be used to understand both ocean temperature change and regional geology. Analysis of our data shows that at depths of 300–900 m below sea level, the Arctic Ocean has been warming steadily for perhaps several decades—nearly twice as deep as previous studies suggest. At ocean depths greater than 1,000 m, our analysis also reveals surprisingly high temperature increases with depth in the seafloor. The cause of these significant increases is unclear.

58 GEOSCIENCES↗

Advanced Modular Power System Fully Populated Electronics Enclosure Thermal Testing

A thermal test of an enclosure housing the AMPS electronics cards was performed. The enclosure was fully populated with 17 nonfunctioning AMPS electronics cards. Heaters were applied to the cards to simulate their operation. A cold plate was installed on the top of the case. The case was then insulated to simulate its installation within an electronics rack with the face and rear of the enclosure left open. The cold plate was connected to a chiller which provided cooling water at a fixed input temperature to the cold plate. Flow rates from the chiller of 0.0 L/min, 1.4 L/min and 1.8 L/min were tested. The test was operated at each flow rate over a range of heater power levels until the steady state temperature of the electronics cards was reached. Heater power levels from 2.5 W/card to 45 W/card were tested. The data collected was used to determine the steady state operating temperature of the cards, the temperature distribution between the cards, the time to reach steady-state temperature, the change in steady state temperature with change in heater power, the temperature distribution between the cards at the steady state condition and the heat lost to the surrounds by the enclosure. One of the main goals of the testing was to determine how much waste heat the cards could generate and still maintain a touch temperature at or below 40°C. Based on this requirement, for the 3 cooling rates tested, the maximum card waste heat that could be generated by each individual card was 3.9 W, 16.3 W and 17.6 W respectively. An analysis was also set up to provide an analytical model to estimate the card temperature under different cold plate flow rates and card heater power levels. The results off the analysis was compared to that of the experiment of the range of flow rates and power levels tested.

Anthony Colozza↗

Demonstration of 4H-SiC JFET Digital ICs Across 1000 °C Temperature Range Without Change to Input Voltages

Operational testing of prototype 4H-SiC JFET ICs across an unrivaled ambient temperature span in excess of 1000 °C, from -190 °C to +812 °C, has been demonstrated without any change/adjustment of input signal levels or power supply voltages. This unique ability is expected to simplify infusion of this IC technology into a broader range of beneficial applications.

Neudeck, Philip G.↗

Correlation of the Hippocampal theta rhythm to changes in hypothalamic temperature

Warming and cooling the preoptic anterior hypothalamic area in awake, loosely restrained rabbits was found to evoke theta rhythm. This is consistent with previous studies indicating that theta rhythm is a nonspecific response evoked by stimulation of several sensory modalities. Several studies have correlated theta rhythm with alertness. A neural pathway involving the hypothalamus, the hippocampus, the septal area, and the reticular formation is proposed. Thus, a role of this pathway may be to alert the animal to changes in its body temperature.

Saleh, M. A.↗

Phase Change Fabrics Control Temperature

Originally featured in Spinoff in 1997, Outlast Technologies Inc. (formerly Gateway Technologies Inc.) has built its entire product line on microencapsulated phase change materials, developed in Small Business Innovation Research (SBIR) contracts with Johnson Space Center after initial development for the U.S. Air Force. The Boulder, Colorado-based company acquired the exclusive patent rights and now integrates these materials into textiles or onto finished apparel, providing temperature regulation in bedding materials and a full line of apparel for both ordinary and extreme conditions.

Source record↗

Effect of Propranolol on Thyroxine-Induced Changes in Body Temperature and Metabolism During Exercise in Dogs

Effects of thyroxine on temperature and metabolism during exercise were studied in dogs after beta-adrenergic blockade. Dogs performed 60 min treadmill exercise of moderate intensity 5 and 72 h following thyroxine injected s. c. in a single dose of 0.1 mg/kg b.w. Thyroxine increased significantly the lipolytic response to exercise as well as blood lactate (LA) concentrations and rectal temperature (T(sub re)) during exercise as early as 5 h following the hormone administration. The changes became more pronounced 72 h after the injection. At rest T(sub re), blood FFA (free fatty acid) and LA levels in the thyroxine-treated dogs did not differ from the control values, and blood glucose was slightly, but significantly higher. Propranolol given intravenously in a dose of 0.25 mg/kg at 30 min of the exercise performed 72 h following thyroxine injection abolished the plasma FFA rise, and inhibited to a certain extent increases in T(sub re) and blood LA concentrations during the next 30 min of exercise.

Kaciuba-Uscilko, Hanna↗

Temperature Oscillations in Loop Heat Pipe Operation

Loop heat pipes (LHPs) are versatile two-phase heat transfer devices that have gained increasing acceptance for space and terrestrial applications. The operating temperature of an LHP is a function of its operating conditions. The LHP usually reaches a steady operating temperature for a given heat load and sink temperature. The operating temperature will change when the heat load and/or the sink temperature changes, but eventually reaches another steady state in most cases. Under certain conditions, however, the loop operating temperature never really reaches a true steady state, but instead becomes oscillatory. This paper discusses the temperature oscillation phenomenon using test data from a miniature LHP.

Ku, Jentung↗

Model Advancements to Enable Impact Analysis of Climate Change on Streamflow Temperature

With support from the Department of Energy’s Water Power Technologies Office, Pacific Northwest National Laboratory (PNNL) has developed new tools that incorporate cutting-edge climate and hydrological science capabilities to assess the potential long-term impacts of future climate conditions on unregulated streamflow and water temperature within watershed-river-reservoir systems. The objectives of this project were achieved by enhancing key hydrologic and hydrodynamic models and transferring them to a high-performance computing environment to provide a high-spatiotemporal resolution, multi-scale modeling framework. The new modeling framework has the potential to quantify risks related climate change impacts on runoff, unregulated streamflow, and water temperature. Initial development and demonstration of the modeling framework was conducted under historical and future climate conditions in the Columbia River Basin in the Pacific Northwest and the Connecticut River Basin in New England.

13 HYDRO ENERGY↗

Phase Change Material for Temperature Control of Imager or Sounder on GOES Type Satellites in GEO

An imager or sounder on satellites, such as the Geostationary Operational Environmental Satellite (GOES), in geostationary orbit (GEO) has a scan mirror and motor in the scan cavity. The GEO orbit is 24 hours long. During part of the orbit, direct sunlight enters the scan aperture and adds heat to components in the scan cavity. Solar heating also increases the scan motor temperature. Overheating of the scan motor could reduce its reliability. For GOES-N to P, a radiator with a thermal louver rejects the solar heat absorbed to keep the scan cavity cool. A sunshield shields the radiator/louver from the Sun. This innovation uses phase change material (PCM) in the scan cavity to maintain the temperature stability of the scan mirror and motor. When sunlight enters the scan aperture, solar heating causes the PCM to melt. When sunlight stops entering the scan aperture, the PCM releases the thermal energy stored to keep the components in the scan cavity warm. It reduces the heater power required to make up the heat lost by radiation to space through the aperture. This is a major advantage when compared to a radiator/ louver. PCM is compact because it has a high solid-to-liquid enthalpy. Also, it could be spread out in the scan cavity. This is another advantage. Paraffin wax is a good PCM candidate, with high solid-to-liquid enthalpy, which is about 225 kJ/kg. For GOES-N to P, a radiator with a louver rejects the solar heat that enters the aperture to keep the scan cavity cool. For the remainder of the orbit, sunlight does not enter the scan aperture. However, the radiator/louver continues radiating heat to space because the louver effective emittance is about 0.12, even if the louver is fully closed. This requires makeup heater power to maintain the temperature within the stability range.

Choi, Michael↗

An increase in marine heatwaves without significant changes in surface ocean temperature variability

Marine heatwaves (MHWs)—extremely warm, persistent sea surface temperature (SST) anomalies causing substantial ecological and economic consequences—have increased worldwide in recent decades. Concurrent increases in global temperatures suggest that climate change impacted MHW occurrences, beyond random changes arising from natural internal variability. Moreover, the long-term SST warming trend was not constant but instead had more rapid warming in recent decades. Here we show that this nonlinear trend can—on its own—appear to increase SST variance and hence MHW frequency. Using a Linear Inverse Model to separate climate change contributions to SST means and internal variability, both in observations and CMIP6 historical simulations, we find that most MHW increases resulted from regional mean climate trends that alone increased the probability of SSTs exceeding a MHW threshold. Our results suggest the need to carefully attribute global warming-induced changes in climate extremes, which may not always reflect underlying changes in variability.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Low Noise, Precision Voltage Reference REF5025-HT Under Extreme Temperatures

The performance of Texas Instruments precision voltage reference REF5025-HT was assessed under extreme temperatures. This low noise, 2.5 V output chip is suitable for use in high temperature down-hole drilling applications, but no data existed on its performance at cryogenic temperatures. The device was characterized in terms of output voltage and supply current at different input voltage levels as a function of temperature between +210 C and -190 C. Line and load regulation characteristics were also established at six load levels and at different temperatures. Restart capability at extreme temperatures and the effects of thermal cycling, covering the test temperature range, on its operation and stability were also investigated. Under no load condition, the voltage reference chip exhibited good stability in its output over the temperature range of -50 C to +200 C. Outside that temperature range, output voltage did change as temperature was changed. For example, at the extreme temperatures of +210 C and - 190 C, the output level dropped to 2.43 V and 2.32 V, respectively as compared to the nominal value of 2.5 V. At cryogenic test temperatures of -100 C and -150 C the output voltage dropped by about 20%. The quiescent supply current of the voltage reference varied slightly with temperature but remained close to its specified value. In terms of line regulation, the device exhibited excellent stability between -50 C and +150 C over the entire input voltage range and load levels. At the other test temperatures, however, while line regulation became poor at cryogenic temperatures of -100 C and below, it suffered slight degradation at the extreme high temperature but only at the high load level of 10 mA. The voltage reference also exhibited very good load regulation with temperature down to -100 C, but its output dropped sharply at +210 C only at the heavy load of 10 mA. The semiconductor chip was able restart at the extreme temperatures of -190 C and +210 C, and the limited thermal cycling did not influence its characteristics and had no impact on its packaging as no structural or physical damage was observed.

Patterson, Richard↗

Search for temperature-related albedo changes in nightside and posteclipse images of Io

Using an image-summing process that increases the visibility of Jupiterlit surface features in Voyager images, we have produced the best-ever violet-filter image of the nightside of Io and the best-ever nightside/dayside brightness ratio map of this jovian moon. The ratio map shows no convincing evidence, on either global or local scales, of diurnal temperature-dependent albedo variations. We have also taken an image-ratioing technique developed by O'Shaughnessy et al. (1989), which those authors applied to Voyager violet-filter observations of one Io eclipse reappearance, and extended it to two other, higher-resolution Voyager posteclipse imaging sequences. In none of three imaging sequences do we find any isolated surface regions that convincingly exhibit posteclipse temperature-related albedo variations. These negative results suggest that on Io, pure cyclo-octasulfur (S8), and transient nighttime or in-eclipse deposits of SO2 frost, are at best limited to isolated areas smaller than the resolution of the images in use (i.e., smaller than a few tens of kilometers in size). Such limits are consistent with (1) the negative results reported by the majority of telescopic observers who have searched for posteclipse brightening of Io, (2) indications that physical processes in the ionian surface environment will change any S8 into other allotropes of sulfur, and (3) suggestions that Io's atmosphere is too thin to allow the deposition of transient, optically thick SO2 frost layers at nighttime or during eclipse.

Simonelli, Damon P.↗

Relaxed tarantula skeletal muscle has two ATP energy-saving mechanisms

Myosin molecules in the relaxed thick filaments of striated muscle have a helical arrangement in which the heads of each molecule interact with each other, forming the interacting-heads motif (IHM). In relaxed mammalian skeletal muscle, this helical ordering occurs only at temperatures >20°C and is disrupted when temperature is decreased. Recent x-ray diffraction studies of live tarantula skeletal muscle have suggested that the two myosin heads of the IHM (blocked heads [BHs] and free heads [FHs]) have very different roles and dynamics during contraction. Here, we explore temperature-induced changes in the BHs and FHs in relaxed tarantula skeletal muscle. We find a change with decreasing temperature that is similar to that in mammals, while increasing temperature induces a different behavior in the heads. At 22.5°C, the BHs and FHs containing ADP.Pi are fully helically organized, but they become progressively disordered as temperature is lowered or raised. Our interpretation suggests that at low temperature, while the BHs remain ordered the FHs become disordered due to transition of the heads to a straight conformation containing Mg.ATP. Above 27.5°C, the nucleotide remains as ADP.Pi, but while BHs remain ordered, half of the FHs become progressively disordered, released semipermanently at a midway distance to the thin filaments while the remaining FHs are docked as swaying heads. We propose a thermosensing mechanism for tarantula skeletal muscle to explain these changes. Our results suggest that tarantula skeletal muscle thick filaments, in addition to having a superrelaxation–based ATP energy-saving mechanism in the range of 8.5–40°C, also exhibit energy saving at lower temperatures (<22.5°C), similar to the proposed refractory state in mammals.

59 BASIC BIOLOGICAL SCIENCES↗

Impacts of projected changes in sea surface temperature on ozone pollution in China toward carbon neutrality

The global sea surface temperatures (SSTs) are expected to change diversely in the future under different climate scenarios, which will affect the near-surface ozone (O 3 ) distribution and concentration by influencing meteorological states and large-scale atmospheric circulation. Many countries have planned to reach carbon neutrality by the mid-21st century. Here in this study, the impacts of global and regional SST changes on near-surface O 3 concentrations in China in the middle of the 21st century under the carbon-neutral scenario (Shared Socioeconomic Pathway 1-1.9), compared with the high-emission scenario (Shared Socioeconomic Pathway 5-8.5), and possible physical and chemical mechanisms are investigated using the Community Earth System Model version 1 (CESM1). Under future climate change, the changes in SSTs in the carbon-neutral scenario relative to the high-emission scenario lead to a dipole change in near-surface O 3 concentrations in eastern and western China, with a significant decrease of 0.79 ppbv in the eastern China and a significant increase of 1.05 ppbv in the western China. The cooling of North Pacific Ocean under the carbon-neutral scenario causes a decrease in near-surface O 3 concentrations by 0.48 ppbv in eastern China due to the weakened chemical production and an increase by 0.74 ppbv in western China attributed to the enhanced O 3 transport from Eurasia. Cooling of Southern Hemisphere oceans leads to anomalous upward air motions over eastern China, which weaken the vertical transport of high-altitude O 3 to the surface. Our results suggest that future changes in SSTs in the carbon-neutral scenario will positively benefit O 3 air quality improvement in the polluted eastern China, with the North Pacific and Southern Hemisphere oceans playing important roles.

54 ENVIRONMENTAL SCIENCES↗