At least 1,009 records · Page 56

Global ozone long-term trends from satellite measurements and the response to solar activity variations

Analysis of global ozone variations for the period April 1970 to December 1975 was performed by using the reprocessed Nimbus 4 backscattered ultraviolet (BUV) measurements of total ozone. A correlation coefficient of 0.97 is found between the 6-month running mean of global mean total ozone (filtered for mean semiannual, annual, and quasibiennial variations) and the 10.7-cm solar activity index. Correcting ozone for a time-dependent latitudinal bias relative to Dobson ozone measurements reduces to 2-3% the global mean ozone variation over the solar cycle. The solar ultraviolet variability required in a one-dimensional time-dependent radiative photochemical model to account for the observed ozone variation appears to be consistent with recent solar UV observations.

Keating, G. M.↗

Enhancing the Representation of Subgrid Land Surface Characteristics in Land Surface Models

Land surface heterogeneity has long been recognized and increasingly incorporated in the land surface modelling. In most existing land surface models, the spatial variability of surface cover is represented as subgrid composition of multiple surface cover types. In this study, we developed a new subgrid classification method (SGC) that accounts for the topographic variability of the vegetation cover. Each model grid cell was represented with a number of elevation classes and each elevation class was further described by a number of vegetation types. The numbers of elevation classes and vegetation types were variable and optimized for each model grid so that the spatial variability of both elevation and vegetation can be reasonably explained given a pre-determined total number of classes. The subgrid structure of the Community Land Model (CLM) was used as an example to illustrate the newly developed method in this study. With similar computational burden as the current subgrid vegetation representation in CLM, the new method is able to explain at least 80% of the total subgrid PFTs and greatly reduced the variations of elevation within each subgrid class compared to the baseline method where a single elevation class is assigned to each subgrid PFT. The new method was also evaluated against two other subgrid methods (SGC1 and SGC2) that assigned fixed numbers of elevation and vegetation classes for each model grid with different perspectives of surface cover classification. Implemented at five model resolutions (0.1°, 0.25°, 0.5°, 1.0° and 2.0°) with three maximum-allowed total number of classes N_class of 24, 18 and 12 representing different computational burdens over the North America (NA) continent, the new method showed variable performances compared to the SGC1 and SGC2 methods. However, the advantage of the SGC method over the other two methods clearly emerged at coarser model resolutions and with moderate computational intensity (N_class = 18) as it explained the most PFTs and elevation variability among the three subgrid methods. Spatially, the SGC method explained more elevation variability in topography-complex areas and more vegetation variability in flat areas. Furthermore, the variability of both elevation and vegetation explained by the new method was more spatially homogeneous regardless of the model resolutions and computational burdens. The SGC method will be implemented in CLM over the NA continent to assess its impacts on simulating land surface processes.

characteristics↗

Comparative Analysis of Alternative Spectral Bands of CO2 and O2 for the Sensing of CO2 Mixing Ratios

We performed comparative studies to establish favorable spectral regions and measurement wavelength combinations in alternative bands of CO2 and O2, for the sensing of CO2 mixing ratios (XCO2) in missions such as ASCENDS. The analysis employed several simulation approaches including separate layers calculations based on pre-analyzed atmospheric data from the modern-era retrospective analysis for research and applications (MERRA), and the line-byline radiative transfer model (LBLRTM) to obtain achievable accuracy estimates as a function of altitude and for the total path over an annual span of variations in atmospheric parameters. Separate layer error estimates also allowed investigation of the uncertainties in the weighting functions at varying altitudes and atmospheric conditions. The parameters influencing the measurement accuracy were analyzed independently and included temperature sensitivity, water vapor interferences, selection of favorable weighting functions, excitations wavelength stabilities and other factors. The results were used to identify favorable spectral regions and combinations of on / off line wavelengths leading to reductions in interferences and the improved total accuracy.

Pliutau, Denis↗

Modelling of total solar irradiance variability from ground-based observations

The difficulty in correlating models of solar irradiance variations from ground-based observations with spacecraft data is examined. Methods for modeling total solar irradiance are reviewed. A photometric program is described which produces sunspot irradiance fluctuation information that is repeatable to within 10 millionths of the mean irradiance. The results from this program are compared with model irradiance fluctuations based on published sunspot and plage areas.

Chapman, G. A.↗

Early-type galaxy archeology: Ages, abundance ratios, and effective temperatures from full-spectrum fitting

The stellar populations of galaxies hold vital clues to their formation histories. In this paper we present results based on modeling stacked spectra of early-type galaxies drawn from the Sloan Digital Sky Survey as a function of velocity dispersion, σ, from 90 km s{sup –1} to 300 km s{sup –1}. The spectra are of extremely high quality, with typical signal-to-noise ratio of 1000 Å{sup –1}, and a wavelength coverage of 4000 Å –8800 Å. Our population synthesis model includes variation in 16 elements from C to Ba, a two-component star formation history, the shift in effective temperature, Δ T {sub eff}, of the stars with respect to a solar metallicity isochrone, and the stellar initial mass function, among other parameters. In our approach we fit the full optical spectra rather than a select number of spectral indices and are able to, for the first time, measure the abundances of the elements V, Cr, Mn, Co, and Ni from the integrated light of distant galaxies. Our main results are as follows: (1) light-weighted stellar ages range from 6-12 Gyr from low to high σ; (2) [Fe/H] varies by less than 0.1 dex across the entire sample; (3) Mg closely tracks O, and both increase from ≈0.0 at low σ to ∼0.25 at high σ; Si and Ti show a shallower rise with σ, and Ca tracks Fe rather than O; (4) the iron peak elements V, Cr, Mn, and Ni track Fe, while Co tracks O, suggesting that Co forms primarily in massive stars; (5) C and N track O over the full sample and [C/Fe] and [N/Fe] exceed 0.2 at high σ; and (6) the variation in Δ T {sub eff} with total metallicity closely follows theoretical predictions based on stellar evolution theory. This last result is significant because it implies that we are robustly solving not only for the detailed abundance patterns but also the detailed temperature distributions (i.e., isochrones) of the stars in these galaxies. A variety of tests reveal that the systematic uncertainties in our measurements are probably 0.05 dex or less. Our derived [Mg/Fe] and [O/Fe] abundance ratios are 0.05-0.1 dex lower than most previous determinations. Under the conventional interpretation that the variation in these ratios is due to star formation timescale variations, our results suggest longer star formation timescales for massive early-type galaxies than previous studies. Detailed chemical evolution models are necessary in order to translate the abundance ratio distributions of these galaxies into constraints on their formation histories. Alternatively, these data may provide useful constraints on the nucleosynthetic pathways for elements whose production is not well understood.

79 ASTRONOMY AND ASTROPHYSICS↗

Further interpretation of satellite measurements of Antarctic total ozone

Both dynamical and chemical mechanisms have been advanced to explain the decrease in total ozone in the Antarctic spring. Further analysis of satellite measurements show that during any one year, the September decline in total ozone near the South Pole is compensated by an increase at midlatitudes. The total ozone amount from 44 deg S to the pole remains almost unchanged from August through November even though both the polar and midlatitude values reach extremes during this period. These observations suggest that the variations within the spring season in south polar total ozone are governed by dynamical redistribution rather than chemical processes.

Stolarski, Richard S.↗

Spatial variations in tropical ozone - The influence of meridional transport and planetary waves in the stratosphere

The backscatter ultraviolet instrument on the Atmosphere Explorer-E satellite has acquired a large body of stratospheric and total ozone data in the tropical region. The latitudinal variation of the ozone mixing ratio on constant pressure surfaces shows the transition from chemical domination to transport control between 5 and 10 mb. Spectral analysis of the longitudinal O3 structure reveals large wavenumber 1 and 2 patterns, although considerable activity in wavenumbers 5 through 7 sometimes appears. Longitudinal structure increases with decreasing pressure between 30 and 5 mb. The spatial variability near 5 mb must reflect similar structure in the odd nitrogen distribution which provides the major loss mechanism for ozone at this level.

Frederick, J. E.↗

Flame radiation

Total radiation and heat flux data was obtained on a combustor liner by advanced instrumentation. If the results obtained by the special instrumentation are considered to be representative of the total radiation and heat flux, then the effect of variation of engine operating parameters and of fuel type can be more easily obtained. The special instrumentation used for these investigations consisted of five total radiometers and two total heat flux gages. The radiometers were arranged axially and circumferentially through sliding air seals in the outer liner. The two heat flux gages were welded in the outer liner between two circumferential radiometers. Static pressures were obtained on both the cold and the hot side of the outer liner in the area of the heat flux gages. Liner metal temperatures were also obtained. The combustor inlet pressure was varied over a nominal range of 0.5 to 2.07 MPa, inlet air temperature from 550 to 670 K, and fuel-air ratio from about 0.015 to 0.040. The two fuels tested were ASTM Jet A and a fuel designated as ERBS V. Results of the tests are discussed.

Wear, J. D.↗

Poloidal asymmetries in edge transport barriers

Measurements of impurities in Alcator C-Mod indicate that in the pedestal region, significant poloidal asymmetries can exist in the impurity density, ion temperature, and main ion density. In light of the observation that ion temperature and electrostatic potential are not constant on a flux surface [Theiler et al. , Nucl. Fusion 54, 083017 (2014)], a technique based on total pressure conservation to align profiles measured at separate poloidal locations is presented and applied. Gyrokinetic neoclassical simulations with XGCa support the observed large poloidal variations in ion temperature and density, and that the total pressure is approximately constant on a flux surface. With the updated alignment technique, the observed in-out asymmetry in impurity density is reduced from previous publishing [Churchill et al. , Nucl. Fusion 53, 122002 (2013)], yet remains substantial (n z,H /n z,L ~6). Candidate asymmetry drivers are explored, showing that neither non-uniform impurity sources nor localized fluctuation-driven transport are able to explain satisfactorily the impurity density asymmetry. Since impurity density asymmetries are only present in plasmas with strong electron density gradients, and radial transport timescales become comparable to parallel transport timescales in the pedestal region, it is implied that global transport effects relating to the strong electron density gradients in the pedestal are the main driver for the pedestal in-out impurity density asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking carbon fluxes of the ISIMIP2a biome models

The purpose of this study is to evaluate the eight ISIMIP2a biome models against independent estimates of long-term net carbon fluxes (i.e. Net Biome Productivity, NBP) over terrestrial ecosystems for the recent four decades (1971–2010). Here, we evaluate modeled global NBP against 1) the updated global residual land sink (RLS) plus land use emissions (E LUC ) from the Global Carbon Project (GCP), presented as R + L in this study by Le Quéré et al (2015), and 2) the land CO 2 fluxes from two atmospheric inversion systems: Jena CarboScope s81_v3.8 and CAMS v15r2, referred to as F Jena and F CAMS respectively. The model ensemble-mean NBP (that includes seven models with land-use change) is higher than but within the uncertainty of R + L, while the simulated positive NBP trend over the last 30 yr is lower than that from R + L and from the two inversion systems. ISIMIP2a biome models well capture the interannual variation of global net terrestrial ecosystem carbon fluxes. Tropical NBP represents 31 ± 17% of global total NBP during the past decades, and the year-to-year variation of tropical NBP contributes most of the interannual variation of global NBP. According to the models, increasing Net Primary Productivity (NPP) was the main cause for the generally increasing NBP. Significant global NBP anomalies from the long-term mean between the two phases of El Niño Southern Oscillation (ENSO) events are simulated by all models (p < 0.05), which is consistent with the R + L estimate (p = 0.06), also mainly attributed to NPP anomalies, rather than to changes in heterotrophic respiration (Rh). The global NPP and NBP anomalies during ENSO events are dominated by their anomalies in tropical regions impacted by tropical climate variability. Multiple regressions between R + L, F Jena and F CAMS interannual variations and tropical climate variations reveal a significant negative response of global net terrestrial ecosystem carbon fluxes to tropical mean annual temperature variation, and a non-significant response to tropical annual precipitation variation. According to the models, tropical precipitation is a more important driver, suggesting that some models do not capture the roles of precipitation and temperature changes adequately.

54 ENVIRONMENTAL SCIENCES↗

A test of water vapor radiometer-based troposphere calibration using VLBI observations on a 21-kilometer baseline

Simultaneous very long baseline interferometry (VLBI) and water vapor radiometer (WVR) measurements on a 21 km baseline showed that calibration by WVRs removed a significant fraction of the effect of tropospheric delay fluctuations for these experiments. From comparison of the residual delay variations within scans and between scans, the total tropospheric contribution t the delay residuals for each of the three 5 to 20 hour sessions was estimated as 1, 17, and 10%, with the first value being uncertain. The observed improvement in rms residual delay from WVR calibration during these three sessions was 4, 16, and 2%, respectively. The improvement is consistent with the estimated 2 to 3 mm path delay precision of current WVRs. The VLBI measurements, of natural radio sources, were conducted in April and May 1993 at Goldstone, California. Dual-frequency (2.3 and 8.4 GHz) observations were employed to remove the effects of charged particles from the data. Measurements with co-pointed WVRs, located within 50 m of the axis of each antenna, were performed to test the ability of the WVRs to calibrate line-of-sight path delays. Factors that made WVR performance assessment difficult included (1) the fact that the level of tropospheric fluctuations was smaller than is typical for Goldstone during these experiments and (2) VLBI delay variations on longer time scales (i.e., over multiple scans) contained uncalibrated instrumental effects (probably a result of slow temperature variations in the VLBI hardware) that were larger than the tropospheric effects.

Linfield, R. P.↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PEBBED Uncertainty and Sensitivity Analysis of the CRP-5 PBMR DLOFC Transient Benchmark with the SUSA Code

The need for a defendable and systematic uncertainty and sensitivity approach that conforms to the Code Scaling, Applicability, and Uncertainty (CSAU) process, and that could be used for a wide variety of software codes, was defined in 2008. The GRS (Gesellschaft für Anlagen und Reaktorsicherheit) company of Germany has developed one type of CSAU approach that is particularly well suited for legacy coupled core analysis codes, and a trial version of their commercial software product SUSA (Software for Uncertainty and Sensitivity Analyses) was acquired on May 12, 2010. This report summarized the results of the initial investigations performed with SUSA, utilizing a typical High Temperature Reactor benchmark (the IAEA CRP-5 PBMR 400MW Exercise 2) and the PEBBED-THERMIX suite of codes. The following steps were performed as part of the uncertainty and sensitivity analysis: 1. Eight PEBBED-THERMIX model input parameters were selected for inclusion in the uncertainty study: the total reactor power, inlet gas temperature, decay heat, and the specific heat capability and thermal conductivity of the fuel, pebble bed and reflector graphite. 2. The input parameters variations and probability density functions were specified, and a total of 800 PEBBED-THERMIX model calculations were performed, divided into 4 sets of 100 and 2 sets of 200 Steady State and Depressurized Loss of Forced Cooling (DLOFC) transient calculations each. 3. The steady state and DLOFC maximum fuel temperature, as well as the daily pebble fuel load rate data, were supplied to SUSA as model output parameters of interest. The 6 data sets were statistically analyzed to determine the 5% and 95% percentile values for each of the 3 output parameters with a 95% confidence level, and typical statistical indictors were also generated (e.g. Kendall, Pearson and Spearman coefficients). 4. A SUSA sensitivity study was performed to obtain correlation data between the input and output parameters, and to identify the primary contributors to the output data uncertainties. It was found that the uncertainties in the decay heat, pebble bed and reflector thermal conductivities were responsible for the bulk of the propagated uncertainty in the DLOFC maximum fuel temperature. It was also determined that the two standard deviation (2s) uncertainty on the maximum fuel temperature was between ±58oC (3.6%) and ±76oC (4.7%) on a mean value of 1604 oC. These values mostly depended on the selection of the distributions types, and not on the number of model calculations above the required Wilks criteria (a (95%,95%) statement would usually require 93 model runs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diurnal variation of stratospheric chlorine monoxide - A critical test of chlorine chemistry in the ozone layer

Ground-based observations of a mm-wave spectral line at 278 GHz have yielded stratospheric chlorine monoxide column density diurnal variation records which indicate that the mixing ratio and column density of this compound above 30 km are about 20 percent lower than model predictions based on 2.1 parts/billion of total stratospheric chlorine. The observed day-to-night variation is, however, in good agreement with recent model predictions, both confirming the existence of a nighttime reservoir for chlorine and verifying the predicted general rate of its storage and retrieval.

Solomon, P. M.↗

The Survey of Lines in M31 (SLIM): The Drivers of the [C ii]/TIR Variation

The ratio of the [C ii] 158 μm emission line over the total infrared emission (TIR) is often used as a proxy for the photoelectric (PE) heating efficiency (ϵ{sub PE}) of the far-ultraviolet (FUV) photons absorbed by dust in the interstellar medium. In the nearby galaxy M31, we measure a strong radial variation of [C ii]/TIR that we rule out as being due to an intrinsic variation in ϵ{sub PE}. [C ii]/TIR fails as a proxy for ϵ{sub PE}, because the TIR measures all dust heating, not just the contribution from FUV photons capable of ejecting electrons from dust grains. Using extensive multi-wavelength coverage from the FUV to far-infrared, we infer the attenuated FUV emission (UV{sub att}), and the total attenuated flux (TOT{sub att}). We find [C ii]/TIR to be strongly correlated with UV{sub att}/TOT{sub att}, indicating that, in M31 at least, one of the dominant drivers for [C ii]/TIR variation is the relative hardness of the absorbed stellar radiation field. We define ϵ{sub PE}{sup UV}, [C ii]/UV{sub att} which should be more closely related to the actual PE efficiency, which we find to be essentially constant (1.85±0.8%) in all explored fields in M31. This suggests that part of the observed variation of [C ii]/TIR in other galaxies is likely due to a change in the relative hardness of the absorbed stellar radiation field, caused by a combination of variations in the stellar population, dust opacity, and galaxy metallicity, though PE efficiency may also vary across a wider range of environments.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of indium contents on photocatalytic performance of ZnIn{sub 2}S{sub 4} for hydrogen evolution under visible light

A series of ZnIn{sub x}S{sub 4+y} (x=1.6, 2.0, 2.3, 2.6, 2.9, 3.1) photocatalysts were synthesized via a facile hydrothermal method and characterized by various analytical techniques, such as XRD, EDS, UV–vis DRS, SEM, TEM, BET and PL. The ZnIn{sub x}S{sub 4+y} photocatalysts had a similar crystal structure. With the increase of indium content, the absorption edges of ZnIn{sub x}S{sub 4+y} photocatalysts shifted to longer wavelength, their crystal sizes decreased firstly and then increased and the variation of the specific surface area and total pore volume was exactly opposite. Especially, when x=2.3, ZnIn{sub 2.3}S{sub 4+y} catalyst had smallest crystal size, largest specific surface area and total pore volume. Additionally, the morphology of ZnIn{sub x}S{sub 4+y} greatly depended on the contents of indium. The photocatalytic activity of ZnIn{sub x}S{sub 4+y} was evaluated by photocatalytic hydrogen production from water under visible light. The ZnIn{sub 2.3}S{sub 4+y} sample had the highest photocatalytic activity among these ZnIn{sub x}S{sub 4+y} photocatalysts and its hydrogen production rate was 363 μmol/g h. - Graphical abstract: First, a series of catalysts were synthesized. And then those were characterized by various analytical techniques (such as SEM). finally, The photocatalytic activity of catalyst was evaluated by photocatalytic hydrogen production from water under visible light. - Highlights: • The photocatalytic property was studied upon visible-light irradiation. • ZnIn{sub x}S{sub 4+y} photocatalysts show superior photocatalytic activity. • The catalyst of grain size, morphology and BET are related to indium content. • ZnIn{sub x}S{sub 4+y} photocatalysts were synthesized via a facile hydrothermal method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation and control of thoron emanated from lantern mantles

This paper describes the performance of a thoron ({sup 220}Rn) flowthrough source made of a commercially available lantern mantle. This {sup 220}Rn source is easy to construct and operate and has a negligible radon ({sup 222}Rn) gas generated when the air was passed through the source. We studied the {sup 220}Rn concentration generated from the lantern mantles in terms of the variability in concentration associated with both the total weight of the lantern mantles used in the source and the air flow rate used in the experimental chamber. We found that the concentration of {sup 220}Rn generated in air ranged from 0.9 to 150 kBq m{sup -3} and exponentially depended on the absolute humidity. The {sup 220}Rn concentration increased linearly with increasing total weight of the lantern mantles, but variations in the rate of air flow passed through the source had no influence on the observed {sup 220}Rn concentration.