Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

Computational and Experimental Study of Film-Cooling Effectiveness With and Without Downstream Vortex Generators

Downstream vortex generators that involve a pair of rectangular plates arranged in an open V-shape placed just downstream of each film-cooling hole were shown to create flow and vortical structures that entrain lifted film-cooling flow back to the surface and increase its lateral spreading on the surface (GT2020–14317). In this study, computations and measurements were performed to examine the flow mechanisms this vortex generator induces to improve film-cooling effectiveness of a flat plate with the cooling flow emanating from one row of inclined holes. Parameters studied include blowing ratio (BR = 0.75 and 1.0) and temperature ratio (TR = 1.07 and 1.9). Here, the computational study is based on steady Reynolds-averaged Navier–Stokes (RANS) closed by the shear-stress transport (SST) turbulence model with and without conjugate analysis. The experimental study was conducted by using a conjugate heat transfer test rig with a plenum, where cooling flow is introduced. Measurements made include velocity and temperature profiles upstream and downstream of the film-cooling holes as well as the temperature at several locations on the hot and cold sides of the film-cooled flat plate. The computational study was validated by comparing computed results with those from measurements at BR = 0.75 and 1.0 and TR = 1.9. Computational and experimental results are presented to show the effects of BR and TR on the flow structures and how those structures improve the effectiveness of film cooling with and without the downstream vortex generators and with and without conjugate heat transfer.

42 ENGINEERING↗

Presentation of FP7 matter project: general overview

The 2010-2012 implementation plan of the European Sustainable Nuclear Industrial Initiative (ESNII), prepared in the frame of the Sustainable Nuclear Energy Technology Platform (SNETP), establishes a very tight time schedule for the start of construction of the European Gen IV prototypes; namely the construction of the LFR ETPP (European Technology Pilot Plant) MYRRHA will start in 2014 and that of the SFR Prototype ASTRID will start in 2017. The GEN IV reactors pose new challenges to the designers and scientists in terms of higher operating temperature, higher fuel burn-up, and in some cases more corrosive environment with respect to the present technologies and which impacts the materials performance. In this frame, the MATTER (Materials Testing and Rules) Project starts well targeted R and D activities to perform careful materials studies in GEN IV operational conditions and to find out criteria for the correct use of these materials in relevant reactor applications. Aim of the MATTER Project (that involved 27 partners and will end in 2015) is to complement the materials researches, in the frame of the European Energy Research Alliance (EERA) guidelines, with the implementation of pre-normative rules. The MATTER Project is divided in 3 technical Domains (called DM): DM1 - Development of test and evaluation guidelines for structural materials: to develop/establish best practice guidelines for testing and evaluation procedures, which are aimed to screen and characterize nuclear materials for innovative nuclear systems. DM2 - Pre-normative R and D for Codes and Standards: Pre-normative activities are performed, comprehensive of experiments, to revise and update the design rules (with an EU level consensus) in order to answer to some short term needs of the two projects ASTRID and MYRRHA with respect to the design and the construction of structural components. DM3 - Joint Program Scheme, implementation and Priorities: to optimise the effectiveness and efficiency of the EERA Joint Program on nuclear materials for innovative reactors and to support specific research activities related to fundamental understanding of ODS steels fabrication. ODS steels are considered candidate materials, in the medium-long term, for high fuel burn-up cladding application. After a brief presentation of DM1 and DM3, this paper mainly focuses on description of Pre-normative R and D activities for Codes and Standards (DM2). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations

Purpose: The purposes of this work were: (1) To determine if a spectral method can accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for situations where the Cerenkov light is dominant over the scintillation light and (2) to develop a procedural guideline for accurately determining the calibration factors of PSDs. Methods: The authors demonstrate, by using the equations of the spectral method, that the condition for accurately correcting the effect of Cerenkov light is that the ratio of the two calibration factors must be equal to the ratio of the Cerenkov light measured within the two different spectral regions used for analysis. Based on this proof, the authors propose two new procedures to determine the calibration factors of PSDs, which were designed to respect this condition. A PSD that consists of a cylindrical polystyrene scintillating fiber (1.6 mm{sup 3}) coupled to a plastic optical fiber was calibrated by using these new procedures and the two reference procedures described in the literature. To validate the extracted calibration factors, relative dose profiles and output factors for a 6 MV photon beam from a medical linac were measured with the PSD and an ionization chamber. Emphasis was placed on situations where the Cerenkov light is dominant over the scintillation light and on situations dissimilar to the calibration conditions. Results: The authors found that the accuracy of the spectral method depends on the procedure used to determine the calibration factors of the PSD and on the attenuation properties of the optical fiber used. The results from the relative dose profile measurements showed that the spectral method can correct the Cerenkov light effect with an accuracy level of 1%. The results obtained also indicate that PSDs measure output factors that are lower than those measured with ionization chambers for square field sizes larger than 25x25 cm{sup 2}, in general agreement with previously published Monte Carlo results. Conclusions: The authors conclude that the spectral method can be used to accurately correct the Cerenkov light effect in PSDs. The authors confirmed the importance of maximizing the difference of Cerenkov light production between calibration measurements. The authors also found that the attenuation of the optical fiber, which is assumed to be constant in the original formulation of the spectral method, may cause a variation of the calibration factors in some experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18A-06: Dual Energy CT Using One Full Scan and a Second Scan with Very Few Projections

Purpose: The conventional dual energy CT (DECT) requires two full CT scans at different energy levels, resulting in dose increase as well as imaging errors from patient motion between the two scans. To shorten the scan time of DECT and thus overcome these drawbacks, we propose a new DECT algorithm using one full scan and a second scan with very few projections by preserving structural information. Methods: We first reconstruct a CT image on the full scan using a standard filtered-backprojection (FBP) algorithm. We then use a compressed sensing (CS) based iterative algorithm on the second scan for reconstruction from very few projections. The edges extracted from the first scan are used as weights in the Objectives: function of the CS-based reconstruction to substantially improve the image quality of CT reconstruction. The basis material images are then obtained by an iterative image-domain decomposition method and an electron density map is finally calculated. The proposed method is evaluated on phantoms. Results: On the Catphan 600 phantom, the CT reconstruction mean error using the proposed method on 20 and 5 projections are 4.76% and 5.02%, respectively. Compared with conventional iterative reconstruction, the proposed edge weighting preserves object structures and achieves a better spatial resolution. With basis materials of Iodine and Teflon, our method on 20 projections obtains similar quality of decomposed material images compared with FBP on a full scan and the mean error of electron density in the selected regions of interest is 0.29%. Conclusion: We propose an effective method for reducing projections and therefore scan time in DECT. We show that a full scan plus a 20-projection scan are sufficient to provide DECT images and electron density with similar quality compared with two full scans. Our future work includes more phantom studies to validate the performance of our method.

60 APPLIED LIFE SCIENCES↗

WE-G-BRE-09: Targeted Radiotherapy Enhancement During Accelerated Partial Breast Irradiation (ABPI) Using Controlled Release of Gold Nanoparticles (GNPs)

Purpose: Several studies have demonstrated low rates of local recurrence with brachytherapy-based accelerated partial breast irradiation (APBI). However, long-term outcomes on toxicity (e.g. telangiectasia), and cosmesis remain a major concern. The purpose of this study is to investigate the dosimetric feasibility of using targeted non-toxic radiosensitizing gold nanoparticles (GNPs) for localized dose enhancement to the planning target volume (PTV) during APBI while reducing dose to normal tissue. Methods: Two approaches for administering the GNPs were considered. In one approach, GNPs are assumed to be incorporated in a micrometer-thick polymer film on the surface of routinely used mammosite balloon applicators, for sustained controlled in-situ release, and subsequent treatment using 50-kVp Xoft devices. In case two, GNPs are administered directly into the lumpectomy cavity e.g. via injection or using fiducials coated with the GNP-loaded polymer film. Recent studies have validated the use of fiducials for reducing the PTV margin during APBI with 6 MV beams. An experimentally determined diffusion coefficient was used to determine space-time customizable distribution of GNPs for feasible in-vivo concentrations of 43 mg/g. An analytic calculational approach from previously published work was employed to estimate the dose enhancement due to GNPs (2 and 10 nm) as a function of distance up to 1 cm from lumpectomy cavity. Results: Dose enhancement due to GNP was found to be about 130% for 50-kVp x-rays, and 110% for 6-MV external beam radiotherapy, 1 cm away from the lumpectomy cavity wall. Higher customizable dose enhancement could be achieved at other distances as a function of nanoparticle size. Conclusion: Our preliminary results suggest that significant dose enhancement can be achieved to residual tumor cells targeted with GNPs during APBI with electronic brachytherapy or external beam therapy. The findings provide a useful basis for developing nanoparticle-aided APBI, with potential to significantly reduce normal tissue/skin toxicity.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-09: Prediction of Local Control/Failure by Using Feature Histogram Selection in Follow-Up T2-Weighted MR Image in Spinal Tumors After Stereotactic Body Radiation Therapy

Purpose: In follow-up T2-weighted MR images of spinal tumor patients treated with stereotactic body radiation therapy (SBRT), high intensity features embedded in dark surroundings may suggest a local failure (LF). We investigated image intensity histogram in imaging features to predict LF and local control (LC). Methods: Sixty-seven spinal tumors were treated with SBRT at our institution with scheduled follow-up MR T2-weighted (TR 3200–6600ms; TE 75-132ms) imaging. The LF group included 10 tumors with 8.7 months median follow-up, while the LC group had 11 tumors with 24.1 months median follow-up. The follow-up images were fused to the planning CT. Image intensity histograms of the GTV were calculated. Voxels in greater than 90% (V90), 80% (V80), and peak (Vpeak) of the histogram were grouped into sub-ROIs to determine the best feature histogram. The intensity of each sub-ROI was evaluated using the mean T2-weighted signal ratio (intensity in sub-ROI / intensity in normal vertebrae). An ROC curve in predicting LF for each sub-ROI was calculated to determine the best feature histogram parameter for LF prediction. Results: Mean T2-weighted signal ratio in the LF group was significantly higher than that in the LC group for all sub-ROIs (1.1±0.4 vs. 0.7±0.2, 1.2±0.4 vs. 0.8±0.2, 1.4±0.5 vs. 0.8±0.2, for V90, V80, and Vpeak, p=0.02, 0.02, and 0.002, respectively). The corresponding areas-under-curve (AUC) of ROC were 0.78, 0.80, and 0.87, p=0.02, 0.03, 0.004, respectively. No correlation was found between T2-weighted signal ratio in Vpeak and follow-up time (Pearson's ρ=0.15). Conclusion: Increased T2-weighted signal can be used to identify local failure while decreased signal indicates local control after spinal SBRT. By choosing the best histogram parameter (here the Vpeak), the AUC of the ROC can be substantially improved, which implies reliable prediction of LC and LF. These results are being further studied and validated with large multi-institutional data.

60 APPLIED LIFE SCIENCES↗

Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation

Purpose: Intensity modulated proton therapy (IMPT) of head and neck (H and N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone beam CT (CBCT) scanners are currently being offered by vendors, they may offer daily or weekly updates of patient anatomy. CBCT image quality may not be sufficient for accurate proton dose calculation and it is likely necessary to perform CBCT CT number correction. In this work, the authors investigated deformable image registration (DIR) of the planning CT (pCT) to the CBCT to generate a virtual CT (vCT) to be used for proton dose recalculation. Methods: Datasets of six H and N cancer patients undergoing photon intensity modulated radiation therapy were used in this study to validate the vCT approach. Each dataset contained a CBCT acquired within 3 days of a replanning CT (rpCT), in addition to a pCT. The pCT and rpCT were delineated by a physician. A Morphons algorithm was employed in this work to perform DIR of the pCT to CBCT following a rigid registration of the two images. The contours from the pCT were deformed using the vector field resulting from DIR to yield a contoured vCT. The DIR accuracy was evaluated with a scale invariant feature transform (SIFT) algorithm comparing automatically identified matching features between vCT and CBCT. The rpCT was used as reference for evaluation of the vCT. The vCT and rpCT CT numbers were converted to stopping power ratio and the water equivalent thickness (WET) was calculated. IMPT dose distributions from treatment plans optimized on the pCT were recalculated with a Monte Carlo algorithm on the rpCT and vCT for comparison in terms of gamma index, dose volume histogram (DVH) statistics as well as proton range. The DIR generated contours on the vCT were compared to physician-drawn contours on the rpCT. Results: The DIR accuracy was better than 1.4 mm according to the SIFT evaluation. The mean WET differences between vCT (pCT) and rpCT were below 1 mm (2.6 mm). The amount of voxels passing 3%/3 mm gamma criteria were above 95% for the vCT vs rpCT. When using the rpCT contour set to derive DVH statistics from dose distributions calculated on the rpCT and vCT the differences, expressed in terms of 30 fractions of 2 Gy, were within [−4, 2 Gy] for parotid glands (D{sub mean}), spinal cord (D{sub 2%}), brainstem (D{sub 2%}), and CTV (D{sub 95%}). When using DIR generated contours for the vCT, those differences ranged within [−8, 11 Gy]. Conclusions: In this work, the authors generated CBCT based stopping power distributions using DIR of the pCT to a CBCT scan. DIR accuracy was below 1.4 mm as evaluated by the SIFT algorithm. Dose distributions calculated on the vCT agreed well to those calculated on the rpCT when using gamma index evaluation as well as DVH statistics based on the same contours. The use of DIR generated contours introduced variability in DVH statistics.

60 APPLIED LIFE SCIENCES↗

Development and evaluation of aperture-based complexity metrics using film and EPID measurements of static MLC openings

Purpose: Complexity metrics have been suggested as a complement to measurement-based quality assurance for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). However, these metrics have not yet been sufficiently validated. This study develops and evaluates new aperture-based complexity metrics in the context of static multileaf collimator (MLC) openings and compares them to previously published metrics. Methods: This study develops the converted aperture metric and the edge area metric. The converted aperture metric is based on small and irregular parts within the MLC opening that are quantified as measured distances between MLC leaves. The edge area metric is based on the relative size of the region around the edges defined by the MLC. Another metric suggested in this study is the circumference/area ratio. Earlier defined aperture-based complexity metrics—the modulation complexity score, the edge metric, the ratio monitor units (MU)/Gy, the aperture area, and the aperture irregularity—are compared to the newly proposed metrics. A set of small and irregular static MLC openings are created which simulate individual IMRT/VMAT control points of various complexities. These are measured with both an amorphous silicon electronic portal imaging device and EBT3 film. The differences between calculated and measured dose distributions are evaluated using a pixel-by-pixel comparison with two global dose difference criteria of 3% and 5%. The extent of the dose differences, expressed in terms of pass rate, is used as a measure of the complexity of the MLC openings and used for the evaluation of the metrics compared in this study. The different complexity scores are calculated for each created static MLC opening. The correlation between the calculated complexity scores and the extent of the dose differences (pass rate) are analyzed in scatter plots and using Pearson’s r-values. Results: The complexity scores calculated by the edge area metric, converted aperture metric, circumference/area ratio, edge metric, and MU/Gy ratio show good linear correlation to the complexity of the MLC openings, expressed as the 5% dose difference pass rate, with Pearson’s r-values of −0.94, −0.88, −0.84, −0.89, and −0.82, respectively. The overall trends for the 3% and 5% dose difference evaluations are similar. Conclusions: New complexity metrics are developed. The calculated scores correlate to the complexity of the created static MLC openings. The complexity of the MLC opening is dependent on the penumbra region relative to the area of the opening. The aperture-based complexity metrics that combined either the distances between the MLC leaves or the MLC opening circumference with the aperture area show the best correlation with the complexity of the static MLC openings.

60 APPLIED LIFE SCIENCES↗

SU-C-209-06: Improving X-Ray Imaging with Computer Vision and Augmented Reality

Purpose: To determine the feasibility of using a computer vision algorithm and augmented reality interface to reduce repeat rates and improve consistency of image quality and patient exposure in general radiography. Methods: A prototype device, designed for use with commercially available hardware (Microsoft Kinect 2.0) capable of depth sensing and high resolution/frame rate video, was mounted to the x-ray tube housing as part of a Philips DigitalDiagnost digital radiography room. Depth data and video was streamed to a Windows 10 PC. Proprietary software created an augmented reality interface where overlays displayed selectable information projected over real-time video of the patient. The information displayed prior to and during x-ray acquisition included: recognition and position of ordered body part, position of image receptor, thickness of anatomy, location of AEC cells, collimated x-ray field, degree of patient motion and suggested x-ray technique. Pre-clinical data was collected in a volunteer study to validate patient thickness measurements and x-ray images were not acquired. Results: Proprietary software correctly identified ordered body part, measured patient motion, and calculated thickness of anatomy. Pre-clinical data demonstrated accuracy and precision of body part thickness measurement when compared with other methods (e.g. laser measurement tool). Thickness measurements provided the basis for developing a database of thickness-based technique charts that can be automatically displayed to the technologist. Conclusion: The utilization of computer vision and commercial hardware to create an augmented reality view of the patient and imaging equipment has the potential to drastically improve the quality and safety of x-ray imaging by reducing repeats and optimizing technique based on patient thickness. Society of Pediatric Radiology Pilot Grant; Washington University Bear Cub Fund.

60 APPLIED LIFE SCIENCES↗

SU-F-J-06: Optimized Patient Inclusion for NaF PET Response-Based Biopsies

Purpose: A method to guide mid-treatment biopsies using quantitative [F-18]NaF PET/CT response is being investigated in a clinical trial. This study aims to develop methodology to identify patients amenable to mid-treatment biopsy based on pre-treatment imaging characteristics. Methods: 35 metastatic prostate cancer patients had NaF PET/CT scans taken prior to the start of treatment and 9–12 weeks into treatment. For mid-treatment biopsy targeting, lesions must be at least 1.5 cm{sup 3} and located in a clinically feasible region (lumbar/sacral spine, pelvis, humerus, or femur). Three methods were developed based on number of lesions present prior to treatment: a feasibility-restricted method, a location-restricted method, and an unrestricted method. The feasibility restricted method only utilizes information from lesions meeting biopsy requirements in the pre-treatment scan. The unrestricted method accounts for all lesions present in the pre-treatment scan. For each method, optimized classification cutoffs for candidate patients were determined. Results: 13 of the 35 patients had enough lesions at the mid-treatment for biopsy candidacy. Of 1749 lesions identified in all 35 patients at mid-treatment, only 9.8% were amenable to biopsy. Optimizing the feasibility-restricted method required 4 lesions at pre-treatment meeting volume and region requirements for biopsy, resulting patient identification sensitivity of 0.8 and specificity of 0.7. Of 6 false positive patients, only one patient lacked lesions for biopsy. Restricting for location alone showed poor results (sensitivity 0.2 and specificity 0.3). The optimized unrestricted method required patients have at least 37 lesions in pretreatment scan, resulting in a sensitivity of 0.8 and specificity of 0.8. There were 5 false positives, only one lacked lesions for biopsy. Conclusion: Incorporating the overall pre-treatment number of NaF PET/CT identified lesions provided best prediction for identifying candidate patients for mid-treatment biopsy. This study provides validity for prediction-based inclusion criteria that can be extended to various clinical trial scenarios. Funded by Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology to Compare Twitter Reaction Trends between Disinformation Communities, to COVID related Campaign Events at Different Geospatial Granularities

With still ongoing COVID pandemic, there is an immediate need for a deeper understanding of how Twitter discussions (or chatters) in disinformation spreading communities get triggered. More specifically, the value is in monitoring how such trigger events in Twitter discussion do align with the timelines of relevant influencing events in the society (indicated in this work as campaign events). For campaign events in regards to COVID pandemic, we consider both NPI (Nonpharmaceutical Interventions) campaigns and disinformation spreading campaigns together. In this short paper we have presented a novel methodology to quantify, compare and relate two Twitter disinformation communities, in terms of their reaction patterns to the timelines of major campaign events. We have also analyzed these campaigns at their three geospatial granularity contexts: local county, state, and country/ federal. We have conducted a novel dataset collection on campaigns (NPI + Disinformation) at these different geospatial granularities. Then, with collected dataset on Twitter disinformation communities, we have performed a case study to validate our proposed methodology.

De, Debraj↗

Polarized Deep-Inelastic Scattering with Spin Correlations in Herwig 7

This repository is the research software and reproducibility companion for the HerwigPol polarized deep-inelastic scattering implementation developed for Herwig 7. It brings together the modified Herwig and ThePEG source snapshots, the curated POLDIS fixed-order reference code, the custom Rivet analyses, the DIS validation workflow, and the paper source in a single formal repository layout. The repository is intended to preserve the source-level ingredients needed to rebuild and re-run the validated DIS studies. It therefore tracks code, input cards, workflow drivers, and technical notes, while intentionally excluding generated artifacts such as build products, campaign outputs, merged YODA files, plots, and rendered paper outputs.

Papaefstathioou, Andreas [Kennesaw State Universit↗

Efforts to enhance reproducibility in a human performance research project

Background: Ensuring the validity of results from funded programs is a critical concern for agencies that sponsor biological research. In recent years, the open science movement has sought to promote reproducibility by encouraging sharing not only of finished manuscripts but also of data and code supporting their findings. While these innovations have lent support to third-party efforts to replicate calculations underlying key results in the scientific literature, fields of inquiry where privacy considerations or other sensitivities preclude the broad distribution of raw data or analysis may require a more targeted approach to promote the quality of research output. Methods: We describe efforts oriented toward this goal that were implemented in one human performance research program, Measuring Biological Aptitude, organized by the Defense Advanced Research Project Agency's Biological Technologies Office. Our team implemented a four-pronged independent verification and validation (IV&V) strategy including 1) a centralized data storage and exchange platform, 2) quality assurance and quality control (QA/QC) of data collection, 3) test and evaluation of performer models, and 4) an archival software and data repository. Results: Our IV&V plan was carried out with assistance from both the funding agency and participating teams of researchers. QA/QC of data acquisition aided in process improvement and the flagging of experimental errors. Holdout validation set tests provided an independent gauge of model performance. Conclusions: In circumstances that do not support a fully open approach to scientific criticism, standing up independent teams to cross-check and validate the results generated by primary investigators can be an important tool to promote reproducibility of results.

59 BASIC BIOLOGICAL SCIENCES↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗