Search NASA⌕ Search

SEARCH · Search NASA

Results for “variational optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,009 records · Page 56

SU-F-J-103: Assessment of Liver Tumor Contrast for Radiation Therapy: Inter-Patient and Inter-Sequence Variability

Purpose: To determine the variation in tumor contrast between different MRI sequences and between patients for the purpose of MRI-based treatment planning. Methods: Multiple MRI scans of 11 patients with cancer(s) in the liver were included in this IRB-approved study. Imaging sequences consisted of T1W MRI, Contrast-Enhanced T1W MRI, T2W MRI, and T2*/T1W MRI. MRI images were acquired on a 1.5T GE Signa scanner with a four-channel torso coil. We calculated the tumor-to-tissue contrast to noise ratio (CNR) for each MR sequence by contouring the tumor and a region of interest (ROI) in a homogeneous region of the liver using the Eclipse treatment planning software. CNR was calculated (I-Tum-I-ROI)/SD-ROI, where I-Tum and I-ROI are the mean values of the tumor and the ROI respectively, and SD-ROI is the standard deviation of the ROI. The same tumor and ROI structures were used in all measurements for different MR sequences. Inter-patient Coefficient of variation (CV), and inter-sequence CV was determined. In addition, mean and standard deviation of CNR were calculated and compared between different MR sequences. Results: Our preliminary results showed large inter-patient CV (range: 37.7% to 88%) and inter-sequence CV (range 5.3% to 104.9%) of liver tumor CNR, indicating great variations in tumor CNR between MR sequences and between patients. Tumor CNR was found to be largest in CE-T1W (8.5±7.5), followed by T2W (4.2±2.4), T1W (3.4±2.2), and T2*/T1W (1.7±0.6) MR scans. The inter-patient CV of tumor CNR was also the largest in CE-T1W (88%), followed by T1W (64.3%), T1W (56.2%), and T2*/T1W (37.7) MR scans. Conclusion: Large inter-sequence and inter-patient variations were observed in liver tumor CNR. CE-T1W MR images on average provided the best tumor CNR. Efforts are needed to optimize tumor contrast and its consistency for MRI-based treatment planning of cancer in the liver. This project is supported by NIH grant: 1R21CA165384.

60 APPLIED LIFE SCIENCES↗

Enabling Scalable VQE Simulation on Leading HPC Systems

Large-scale simulations of quantum circuits pose significant challenges, especially in the context of quantum chemistry, due to the number of qubits, circuit depth, and the number of circuits needed per problem. High-performance computing (HPC) systems offer massive computational capabilities that could help overcome these obstacles. We developed a high-performance quantum circuit simulator, called NWQ-Sim, and demonstrate its capability to simulate large quantum chemistry problems on NERSC's Perlmutter supercomputer. Integrating NWQ-Sim with XACC, we have executed QPE and VQE algorithms for downfolded quantum chemistry systems at unprecedented scales. Our work demonstrates the potential of leveraging HPC resources to advance quantum chemistry and other applications of near-term quantum devices.

Wang, Meng↗

Space Charge Dominated Momentum Spread and Compensation Strategies in the Post-Linac Section of Proton Improvement Plan-II at Fermilab

The upcoming Proton Improvement Plan-II (PIP-II), designated for enhancements to the Fermilab accelerator complex, features a Beam Transfer Line (BTL) that channels the beam from the linac exit to the booster. In the absence of longitudinal focusing beyond the superconducting linac, the beam experiences an elevated momentum spread, primarily due to nonlinear space-charge forces, surpassing the allowable limit of 2.1e-4. This study presents a detailed examination of the space-charge-induced momentum spread and outlines mitigative strategies. The investigation includes the fine-tuning of a de-buncher cavity, analyzed in terms of operating frequency, longitudinal location, and gap voltage, under both standard and perturbed beam conditions—specifically accounting for momentum jitter and energy variation. The impact of buncher cavity misalignments on the beam's longitudinal phase space is also assessed. The paper concludes by recommending an optimized cavity configuration to effectively mitigate the observed increase in momentum spread along the BTL.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Applying Linear Optics from Closed Orbits Modulation for finding beam-based alignment of harmonic sextupoles

A fast and accurate beam-based alignment (BBA) method for harmonic sextupoles has been devel oped at NSLS-II using Linear Optics from Closed Orbit Modulation (LOCOM). The approach excites the beam with simultaneous sine-wave signals at two fast correctors, chosen with an appropriate phase advance to span the full betatron phase space. This strategy suppresses systematic errors from hysteresis, while additional errors from orbit drift and power-supply calibration are minimized by the short measurement time (a few minutes) and reliance solely on beam-based current-to-field conver sion of the sextupoles, with hysteresis explicitly included. Simulations indicate that Linear Optics from Closed Orbits (LOCO) combined with 0.5 mm local orbit bumps can resolve relative sextupole field offsets (∆k₂) with precision better than 10% of k₂, reflecting to beam-based alignment (BBA) accuracy finer than 50 µm. Moreover, employing machine-learning-optimized local orbit bumps en hances sextupole-induced quadrupole signals in a deterministic manner and maintains orbit stability under large sextupole strength variations (±40%). The proposed method is experimentally validated through proof-of-principle measurements at NSLS-II, demonstrating its potential as a fast, precise, and robust tool for harmonic sextupole alignment.

43 PARTICLE ACCELERATORS↗

Automated tuning for HMC mass ratios

We extended previous work on tuning HMC parameters using gradient information to include Hasenbusch mass ratios. The inclusion of mass ratios adds many more parameters that need to be tuned, and also allows for lots of variations in the choice of integrator pattern. We investigate the effectiveness of automatically tuning a large number of HMC parameters and compare the optimally tuned versions over a range of integrator variants.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Analytical Heat Transfer Models of Multi-layered Natural and Engineered Barriers in Potential High-Level Nuclear Waste Repositories - 12435

A combination of transient heat transfer analytical solutions for a finite line source, a series of point sources, and a series of parallel infinite line sources were combined with a quasi-steady-state multi-layered cylindrical solution to simulate the temperature response of a deep geologic radioactive waste repository with multi-layered natural and engineered barriers. This evaluation was performed to provide information to scientists and decision makers to compare candidate geologic media for a repository (crystalline rock [granite], clay, salt, and deep borehole), and to provide input for the future evaluation of the trade-off between pre-emplacement surface storage time, waste package size, and repository footprint. This approach was selected in favor of the finite element solution typically used to analyze the temperature response because it allowed rapid comparison of a large number of alternative disposal options and design configurations. More than 100 combinations of waste form, geologic environment, repository design configuration, and surface storage times were analyzed and compared. The analytical solution approach used to analyze the repository temperature response allowed rapid comparison of a large number of alternative disposal options and design configurations. More than 100 combinations of waste form, geologic environment, repository design configuration, and surface storage times were analyzed and compared. This approach allowed investigation of the sensitivity of the results to combinations of parameters that show that there is much flexibility to be gained in terms of spent fuel management options by varying a few key parameters. This initial analysis used representative design concepts and thermal constraints based on international design concepts, and it also included waste forms representing future fuel cycles with high burnup fuels. Unlike repository designs with large open tunnels and pre-closure ventilation, all of the disposal concepts analyzed in this study used enclosed emplacement modes, where the waste packages were in direct contact with encapsulating engineered or natural materials. The deep borehole repository concept limits the size of the SNF waste packages and may require rod consolidation to fit within the drill casing diameter. A single assembly waste package, assuming rod consolidation, was evaluated in the current analysis. Similar size restrictions apply for the HLW canisters. At this time no thermal constraints have been defined for the deep borehole repository concept. Representative EBS materials and properties were evaluated. However, changes in EBS design concepts and materials can also have significant effects on the maximum waste package surface temperature. Increased thermal conductivity of the buffer layer can be achieved by using an engineered buffer consisting of a mixture of graphite, sand, and bentonite [14]. One of the advantages of the analytical model is that it highlights the sensitivity of the results to the parameters that define the repository layout, including spacing between axial and lateral neighboring waste packages and drifts. It is clear that repository layout adjustments can be made to reduce the calculated peak temperatures. The results also show that significant reductions in required surface storage times can be achieved if higher thermal constraints can be justified Additional studies are planned to evaluate the trade-offs between surface storage times, repository layout parameters, and variations in EBS design concepts. Model validation and uncertainties will also be addressed. It is expected that shorter surface storage times and more optimized repository design configurations may be achieved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding interfacial crystallization dynamics on carbon fiber reinforced polypropylene composite manufacturing

Reinforcing polymers with discontinuous fibers improves mechanical properties, such as strength and stiffness, and in some cases achieve isotropic properties, rendering them suitable for various engineering applications. Matrix materials are generally highly engineered thermosets (e.g. crosslinked epoxies), bonded to the fiber periphery by proprietary surface and sizing chemistries. Semicrystalline thermoplastic matrices are less utilized due to poor fiber-matrix bonding resulting in inefficient interfacial load-transfer in reinforced composites. However, flexibility with melt-processing or molding conditions can be leveraged to promote non-covalent interfacial bonding between matrix and fiber via crystallization of the matrix onto fiber surface. In the present study, we utilize a co-mingle chopped carbon and isotactic polypropylene fibers to form isotropic composites, tailoring interfacial immobilized matrix or interphase morphology to optimize performance through precise control of thermal processing/molding windows. Calorimetry and optical microscopy were employed to investigate the impact of carbon fiber at various volume fractions (10, 20, and 30 %) on isotactic polypropylene crystallization and mechanical performance. Variations in mechanical properties correspond to the structural evolution of the interfacial region and are correlated to underlying microstructural attributes using wide-angle X-ray scattering, thermal analysis, and low-field nuclear magnetic resonance spectroscopy. These results provide a practical framework for the manufacturing of thermoplastic matrix composites. In conclusion, the results presented provide a guide for the strategic optimization of interphase design, showcasing tailorable tensile strengths which outperform any isotactic polypropylene carbon fiber composites previously reported in literature.

36 MATERIALS SCIENCE↗

Reliable and Efficient Machine Learning (Final Technical Report)

Modern scientific experiments generate massive amounts of data at a pace much faster than humans can manually analyze. While machine learning has revolutionized commercial data analysis (such as recommending movies or recognizing faces), applying these tools to complex scientific discovery is challenging because scientific answers must be precise, interpretable, and adhere to physical laws. The research under this project aims to develop new mathematical tools and computer algorithms specifically designed for scientific applications. Major progress has been made in automatically cleaning and deconstructing messy experimental data, analyzing the visual information of physical phenomena, determining the underlying physical variables, and providing rig orous mathematical analysis of interesting algorithms and concepts widely used in machine learning. This project addressed the critical gap between our ability to generate massive scientific data and our ability to extract interpretable information from it. We established mathematical foundations for Scientific Machine Learning (SciML) aimed at effective data analytics and automated discovery. Our work focused on three core objectives: (1) developing reliable feature extraction methods for dynamic high-dimensional data, (2) establishing mathematical foundations for discovering dynamics via neural networks, and (3) creating rigorous optimization techniques for these models. Key outcomes come from two fronts. On the practical side, they include the development of algorithms that significantly enhance the extraction of signals from field data, as well as the capability to handle situations that exhibit smooth variations or physical stretching due to temperature changes. They also include the creation of an automated framework for discovering fundamental state variables from raw experimental data, demonstrating the ability to identify intrinsic physical dimensions without prior knowledge of the governing laws. On the theoretical front, the research results in theoretical advances in Optimal Transport, a widely used notion in SciML, specifically regarding functions with fixed-size nodal sets, provide sharp bounds relevant to uncertainty quantification. Meanwhile, the outcomes also include the establishment of convergence theories for nonlocal gradient descent methods, enabling robust optimization with noisy data in high-dimensional settings commonly encountered in scientific modeling. The project also helps creating opportunities to train the next generation of researchers, equipping them with the necessary technical skills for today’s workplace and preparing them for future advances.

97 MATHEMATICS AND COMPUTING↗

WE-FG-BRB-02: Spatial Mapping of the RBE of Scanned Particle Beams

The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences between particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRB-00: The Challenges of Predicting RBE Effects in Particle Therapy and Opportunities for Improving Cancer Therapy

The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences between particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRB-01: Clinical Significance of RBE Variations in Proton Therapy

The physical pattern of energy deposition and the enhanced relative biological effectiveness (RBE) of protons and carbon ions compared to photons offer unique and not fully understood or exploited opportunities to improve the efficacy of radiation therapy. Variations in RBE within a pristine or spread out Bragg peak and between particle types may be exploited to enhance cell killing in target regions without a corresponding increase in damage to normal tissue structures. In addition, the decreased sensitivity of hypoxic tumors to photon-based therapies may be partially overcome through the use of more densely ionizing radiations. These and other differences between particle and photon beams may be used to generate biologically optimized treatments that reduce normal tissue complications. In this symposium, speakers will examine the impact of the RBE of charged particles on measurable biological endpoints, treatment plan optimization, and the prediction or retrospective assessment of treatment outcomes. In particular, an AAPM task group was formed to critically examine the evidence for a spatially-variant RBE in proton therapy. Current knowledge of proton RBE variation with respect to dose, biological endpoint, and physics parameters will be reviewed. Further, the clinical relevance of these variations will be discussed. Recent work focused on improving simulations of radiation physics and biological response in proton and carbon ion therapy will also be presented. Finally, relevant biology research and areas of research needs will be highlighted, including the dependence of RBE on genetic factors including status of DNA repair pathways, the sensitivity of cancer stem-like cells to charged particles, the role of charged particles in hypoxic tumors, and the importance of fractionation effects. In addition to the physical advantages of protons and more massive ions over photons, the future application of biologically optimized treatment plans and their potential to provide higher levels of local tumor control and improved normal tissue sparing will be discussed. Learning Objectives: To assess whether the current practice of a constant RBE of 1.1 should be revised or maintained in proton therapy and to evaluate the potential clinical consequences of delivering RBE-weighted dose distributions based on variable RBE To review current research on biological models used to predict the increased biological effectiveness of proton and carbon ions to help move towards a practical understanding and implementation of biological optimization in particle therapy To discuss potential differences in biological mechanisms between photons and charged particles (light and heavy ions) that could impact clinical cancer therapy H. Paganetti, NCI U19 CA21239D. Grosshans, Our research is supported by the NCIK. Held, Funding Support: National Cancer Institute of the National Institutes of Health, USA, under Award Number R21CA182259 and Federal Share of Program Income Earned by Massachusetts General Hospital on C06CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Neural Network-Based Variational Methods for Solving Quadratic Porous Medium Equations in High Dimensions

Here, in this paper, we propose and study neural network-based methods for solutions of high-dimensional quadratic porous medium equation (QPME). Three variational formulations of this nonlinear PDE are presented: a strong formulation and two weak formulations. For the strong formulation, the solution is directly parameterized with a neural network and optimized by minimizing the PDE residual. It can be proved that the convergence of the optimization problem guarantees the convergence of the approximate solution in the $L^1$ sense. The weak formulations are derived following (Brenier in Examples of hidden convexity in nonlinear PDEs, 2020) which characterizes the very weak solutions of QPME. Specifically speaking, the solutions are represented with intermediate functions who are parameterized with neural networks and are trained to optimize the weak formulations. Extensive numerical tests are further carried out to investigate the pros and cons of each formulation in low and high dimensions. This is an initial exploration made along the line of solving high-dimensional nonlinear PDEs with neural network-based methods, which we hope can provide some useful experience for future investigations.

97 MATHEMATICS AND COMPUTING↗

Optimal control with accelerated convergence: Combining the Krotov and quasi-Newton methods

One of the most popular methods for solving numerical optimal control problems is the Krotov method, adapted for quantum control by Tannor and coworkers. The Krotov method has the following three appealing properties: (1) monotonic increase of the objective with iteration number, (2) no requirement for a line search, leading to a significant savings over gradient (first-order) methods, and (3) macrosteps at each iteration, resulting in significantly faster growth of the objective at early iterations than in gradient methods where small steps are required. The principal drawback of the Krotov method is slow convergence at later iterations, which is particularly problematic when high fidelity is desired. We show here that, near convergence, the Krotov method degenerates to a first-order gradient method. We then present a variation on the Krotov method that has all the advantages of the original Krotov method but with significantly enhanced convergence (second-order or quasi-Newton) as the optimal solution is approached. We illustrate the method by controlling the three-dimensional dynamics of the valence electron in the Na atom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-J-63: Abdominal Diameter Changes in Children During Volumetric Modulated Arc Therapy (VMAT): Is Re-Planning Needed?

Purpose: To investigate the dosimetric impact of daily changes in patient’s diameter, due to weight gain/loss and air in the bowel, based on CBCT information during radiotherapy treatment of pediatric abdominal tumors. Methods: 10 pediatric patients with neuroblastoma (n=6) and Wilms’ (n=4) tumors were included. Available CBCTs were affinely registered to the planning CT for daily set-up variations corrections. A density override approach assigning air-density to the random air pockets and water-density to the remaining anatomy was used to determine the CBCT and CT dose. Clinical VMAT plans, with a PTV prescribed dose ranging between (14.4- 36) Gy, were re-optimized on the density override CT and re-calculated on each CBCT. Dose-volume statistics of the PTV and kidneys, delineated on each CBCT, were used to compare the daily and cumulative CBCT dose with the reference CT dose. Results: The average patient diameter variation was (0.5 ± 0.7) cm (maximum daily difference of 2.3 cm). The average PTV mean dose difference (MDD) between the CT and the cumulative CBCT plans was (0.1 ± 1.1) % (maximum daily MDD of 2%). A reduction in target coverage up to 3% and 7% was observed for the cumulative and daily CBCT plans, respectively. The average kidneys’ cumulative MDD was (−2.7 ± 3.6) % (maximum daily MDD of −12%), corresponding to an overdosage. Conclusion: Due to patient’s diameter changes, a target underdosage was assessed. Given the high local tumor control of neuroblastoma and Wilms’ diseases, the need of re-planning might be discarded. However, the assessed kidneys overdosage could represent a problem when the normal tissue tolerance is reached. The necessity of re-planning should then be considered to reduce the risk of long-term renal complications. Due to the poor softtissue contrast on CBCT, MRI-guidance is required to obtain a better assessment of the accumulated dose on the remaining OARs.

60 APPLIED LIFE SCIENCES↗

Anatomy structure creation and editing using 3D implicit surfaces

Purpose: To accurately reconstruct, and interactively reshape 3D anatomy structures' surfaces using small numbers of 2D contours drawn in the most visually informative views of 3D imagery. The innovation of this program is that the number of 2D contours can be very much smaller than the number of transverse sections, even for anatomy structures spanning many sections. This program can edit 3D structures from prior segmentations, including those from autosegmentation programs. The reconstruction and surface editing works with any image modality. Methods: Structures are represented by variational implicit surfaces defined by weighted sums of radial basis functions (RBFs). Such surfaces are smooth, continuous, and closed and can be reconstructed with RBFs optimally located to efficiently capture shape in any combination of transverse (T), sagittal (S), and coronal (C) views. The accuracy of implicit surface reconstructions was measured by comparisons with the corresponding expert-contoured surfaces in 103 prostate cancer radiotherapy plans. Editing a pre-existing surface is done by overdrawing its profiles in image views spanning the affected part of the structure, deleting an appropriate set of prior RBFs, and merging the remainder with the new edit contour RBFs. Two methods were devised to identify RBFs to be deleted based only on the geometry of the initial surface and the locations of the new RBFs. Results: Expert-contoured surfaces were compared with implicit surfaces reconstructed from them over varying numbers and combinations of T/S/C planes. Studies revealed that surface-surface agreement increases monotonically with increasing RBF-sample density, and that the rate of increase declines over the same range. These trends were observed for all surface agreement metrics and for all the organs studied--prostate, bladder, and rectum. In addition, S and C contours may convey more shape information than T views for CT studies in which the axial slice thickness is greater than the pixel size. Surface editing accuracy likewise improves with larger sampling densities, and the rate of improvement similarly declines over the same conditions. Conclusions: Implicit surfaces based on RBFs are accurate representations of anatomic structures and can be interactively generated or modified to correct segmentation errors. The number of input contours is typically smaller than the number of T contours spanned by the structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stan : A Probabilistic Programming Language

Stan is a probabilistic programming language for specifying statistical models. A Stan program imperatively defines a log probability function over parameters conditioned on specified data and constants. As of version 2.14.0, Stan provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods such as the No-U-Turn sampler, an adaptive form of Hamiltonian Monte Carlo sampling. Penalized maximum likelihood estimates are calculated using optimization methods such as the limited memory Broyden-Fletcher-Goldfarb-Shanno algorithm. Stan is also a platform for computing log densities and their gradients and Hessians, which can be used in alternative algorithms such as variational Bayes, expectation propagation, and marginal inference using approximate integration. To this end, Stan is set up so that the densities, gradients, and Hessians, along with intermediate quantities of the algorithm such as acceptance probabilities, are easily accessible. Stan can also be called from the command line using the cmdstan package, through R using the rstan package, and through Python using the pystan package. All three interfaces support sampling and optimization-based inference with diagnostics and posterior analysis. rstan and pystan also provide access to log probabilities, gradients, Hessians, parameter transforms, and specialized plotting.

97 MATHEMATICS AND COMPUTING↗

Feedforward Control of Fuel Distribution on Advanced Dual-Fuel Engines with Varying Intake Valve Closing Timings

This study examines the dynamics and control of an engine operated with late intake valve closure (LIVC) timings in a dual-fuel combustion mode. The engine features a fuel delivery system in which diesel is direct-injected and natural gas is port-injected. Despite the benefits of LIVC and dual-fuel strategy, combining these two techniques resulted in efficiency losses due to the variability of the combustion process across cylinders. The difference in power production across cylinders ranges from 9% at an IVC of 570°ATDC* to 38% at an IVC of 620 °ATDC and indicates an increasingly uneven fuel distribution as the intake valve remains open longer in the compression stroke. This paper describes an approach for controlling the amount of fuel injected into each cylinders’ port of an inline six- cylinder heavy-duty dual-fuel engine to minimize the variations in fuel distribution across cylinder. Since measuring the actual fuel reaching each cylinder is not a practical option on stock engines, this study aimed to produce a feedforward control technique. Using a model developed on an engine simulation software, the optimal fuel injection amounts at each cylinder port across 125 operating conditions (consisting of sweeps of five engine speeds, five engine loads, and five IVC timings) were determined by using PI controllers that adjust the amount of fuel injected at each port based on the amount of fuel reaching the cylinders. The results from the PI controller were expressed as a function of the operating condition (engine speed, engine load, and IVC timing); and consequently, could be reproduced without relying on a measurement of the amount of fuel reaching each cylinder. The feedforward control strategy, unlike the PI controller, is easily implementable on a stock engine and significantly reduces the variations in fuel distribution across cylinders.

Kassa, Mateos↗